Hayward E-Command 4 Model: ALL MODELS Installation - Page 6
Optional Base Station, Optional Valve Actuators - installation manual
View all Hayward E-Command 4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Optional Base Station (included with HPC-4-RC, HPC-4-ACT-RC) The AQL2-BASE-RF optional base station must be installed if the AQL2-SS-RF is used. To install the base station, remove the knockout on the upper left side of the ECOMMAND 4 main control unit, insert the base station, and then tighten the nut from the inside. Also refer to the Base Station manual and the diagram on page 13. Optional Valve Actuators (included with HPC-4-ACT, HPC-4-ACT-RC) For optional actuators used with the ECOMMAND 4-note that the internal cams in the actuator may also have to be adjusted depending on the way the actuator is mounted on the valve and the desired valve action. RETURN SUCTION OUT OUT IN IN (ComINmon) OUT (Common) 3
3
Optional Base Station
(included with HPC-4-RC, HPC-4-ACT-RC)
The AQL2-BASE-RF optional base station must be installed if the AQL2-SS-RF is used. To install the
base station, remove the knockout on the upper left side of the ECOMMAND 4 main control unit, insert
the base station, and then tighten the nut from the inside.
Also refer to the Base Station manual and the
diagram on page 13.
Optional Valve Actuators
(included with HPC-4-ACT, HPC-4-ACT-RC)
For optional actuators used with the ECOMMAND 4—note that the internal cams in the actuator may
also have to be adjusted depending on the way the actuator is mounted on the valve and the desired valve
action.
RETURN
SUCTION
OUT
(Common)
IN
(Common)
OUT
IN
OUT
IN