Hayward E-Command 4 Model: ALL MODELS Operation - Page 14

filter pump low speed operation - turn spa jets off

Page 14 highlights

For two speed or variable speed pumps, this timeclock will set the normal time period for filter pump low speed operation (the word "Filter T2" in the display will be replaced with "Filter Lo"). If the filter pump was off prior to the start of this time period, the filter pump will first turn on at high speed for 3 minutes to prime and establish water flow. Afterwards, it will drop down to low speed for the remainder of the programmed low speed time period. While this time clock will override the high speed timeclock (see above), there are several reasons why the pump will automatically switch to high speed operation during this programmed time period. These include manual operation, spa operation, or heating operation. Refer to page 10 for general notes regarding timeclock programming. Set DSapyaa-nadll Time W6ed:0n0esPdtaoy 91:00:03P7P or Spa-wkend 6:00P to 9:00P Spa-wkday 6:00P to 9:00P Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item This menu is only available if the system has been setup for "pool and spa". During the programmed spa time, the ECOMMAND 4 will turn on the filter pump and move the pool/spa valves into the "spa-only" position. The heater will automatically heat the spa up to the programmed spa temperature (page 6). This programmed spa operation will take precedence over all other automatic functions, only manual operation of the filter button or pool/spa valve button will override this function. If your pool has a separate jet pump or blower controlled by Aux1 and/or Aux2 , you will have to program those separately (see page 12). Set LDigahytasn-dallTime W8e:d0n0ePsdtoay1110:0:307PP or Lights-wkend 8:00P to 11:00P Lights-wkday 8:00P to 11:00P Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item This menu will appear only if the Lights are configured for timeclock. The lights will turn on or and off at the designated times. The only override on this function is manual on/off control by the "Lights" button. Lights-CountDn 0:20 Adjust time setting (Manual On/Off, 0:05, 0:10, 0:015...) Move to previous/next menu item This menu will appear only if the Lights are configured for countdown timer. This setting is the time after you manually turn on the lights until the ECOMMAND 4 automatically turns off the lights. You can also manually turn off the lights at an earlier time by pressing the LIGHTS button. If the Lights relay is on during the programmed off time, it may be because of freeze protection. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

11
For two speed or variable speed pumps, this timeclock will set the normal time period for
filter pump low speed operation
(the word “Filter T2” in the display will be replaced with
“Filter Lo”).
If the filter pump was off prior to the start of this time period, the filter pump will
first turn on at high speed for 3 minutes to prime and establish water flow.
Afterwards, it will
drop down to low speed for the remainder of the programmed low speed time period.
While
this time clock will override the high speed timeclock (see above), there are several reasons
why the pump will automatically switch to high speed operation during this programmed
time period.
These include manual operation, spa operation, or heating operation. Refer to
page 10 for general notes regarding timeclock programming.
This menu is only available if the system has been setup for “pool and spa”.
During the
programmed spa time, the ECOMMAND 4 will turn on the filter pump and move the pool/spa
valves into the “spa-only” position.
The heater will automatically heat the spa up to the
programmed spa temperature (page 6).
This programmed spa operation will take precedence
over all other automatic functions, only manual operation of the filter button or pool/spa
valve button will override this function.
If your pool has a separate jet pump or blower controlled by Aux1 and/or Aux2 , you will have
to program those separately (see page 12).
This menu will appear only if the Lights are configured for timeclock.
The lights will turn on
and off at the designated times.
The only override on this function is manual on/off control
by the “Lights” button.
This menu will appear only if the Lights are configured for countdown timer. This setting is
the time after you manually turn on the lights until the ECOMMAND 4 automatically turns
off the lights.
You can also manually turn off the lights at an earlier time by pressing the
LIGHTS button.
If the Lights relay is on during the programmed off time, it may be because
of freeze protection.
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Spa-all
6:00P to 9:00P
Spa-wkend
6:00P to 9:00P
Spa-wkday
6:00P to 9:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Lights-all
8:00P to 11:00P
Lights-wkend
8:00P to 11:00P
Lights-wkday
8:00P to 11:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
or
Lights-CountDn
0:20
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:015...)
Move to previous/next menu item