Hayward E-Command 4 Model: ALL MODELS Operation - Page 15
Adjust Superchlorination period 1 - 96 hours, Move to previous/next menu item
View all Hayward E-Command 4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Aux1 and Aux2 configurations are identical. Set DAauyx1a-nadllTime Adjust time setting W8e:d3n0eAsdtaoy 41:00:03P7P or Aux1-wkend Move between start and stop times & to previous/next menu item Adjust time setting 8:30A to 4:00P Move between start and stop times & to previous/next menu item Aux1-wkday 8:30A to 4:00P Adjust time setting Move between start and stop times & to previous/next menu item or This menu will appear only if the Aux1 is configured for timeclock. The Aux output will turn on and off at the designated times. If the Aux relay is off during the programmed on time- note that some pool equipment (example pressure side pool cleaner) can only be operated when the filter pump is running and the pool/spa valves are in the pool-only position-the ECOMMAND 4 will keep the relay off until these other conditions are suitable for operation. If the Aux relay is on during the programmed off time, it may be because of freeze protection. Also, manual operation overrides the timeclock. Aux1-CountDn 0:20 Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15...) Move to previous/next menu item This menu will appear only if the Aux1 is configured for countdown timer. This setting is the time after you manually turn on the Aux relay until the ECOMMAND 4 automatically turns off the relay. You can also manually turn off the relay at an earlier time by pressing the AUX1 button. Set VDaalvyea3n-dallTime W8e:d3n0eAsdtaoy 41:00:03P7P or Valve3-wkend 8:30A to 4:00P Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item Valve3-wkday 8:30A to 4:00P Adjust time setting Move between start and stop times & to previous/next menu item This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and off at the designated times. There is no manual override. If the Valve3 relay is on during the programmed off time, it may be because of freeze protection. Super Chlorinate 24 hours Adjust Superchlorination period (1 - 96 hours) Move to previous/next menu item If external chlorination is enabled. For larger pools or when you have an unusually high bather load, a large amount of rain, a cloudy water condition, or any other condition that requires a large amount of chlorine to be introduced to the pool, adjust the Superchlorination period to provide adequate chlorination. Smaller pools require less hours of Superchlorination. 12