Hayward E-Command 4 Model: ALL MODELS Operation - Page 18

Lowest Speed, Highest Speed, Freeze Protection, Freeze Protection Speed, Freeze Protection

Page 18 highlights

For the Hayward Tristar variable speed pump: The Filter relay is used to supply input power to the VSC pump control. The relay will be on when the filter pump output is on. When the filter pump output is off, the relay will be off. On , off and speed is controlled by commands sent to the pump. Lowest Speed This is the lowest speed that the variable speed pump is allowed to run at. It is used as the lower limit in the Low Speed Settings Menu. Set lowest speed from 10% (default) to 50%. Highest Speed This is the highest speed that the variable speed pump is allowed to run at. It is used as the upper limit in the High Speed Settings Menu. Also, this is the speed that the pump will run at during the first 3 minutes of operation anytime the pump has been off for more than 30 seconds. Set highest speed from 20% to 100% (default). Freeze Protection Freeze protection is used to protect the pool and plumbed equipment against freeze damage. If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold (see below), the ECOMMAND 4 will turn on the filter pump to circulate the water. If "Pool and Spa" is selected in the Pool/Spa sub-menu, the valves will also alternate between the pool and spa every 30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only reason the pump is running. Freeze Protection Speed This menu only appears if freeze protection is enabled and the pump is configured for 2speed or variable speed pump operation. This is the speed that the pump will run at during freeze protection operation. Select high (default) or low speed operation. Freeze Protection Temperature Select the temperature to be used for freeze protection. Temperature is adjustable from 33ºF - 42ºF (1ºC - 6ºC). 38ºF (3ºC) is default. This threshold will be used for all outputs that have freeze protection enabled. Heater1 Config. + to view/change Push to access heater options Move to previous/next configuration menu Heater1 Toggle between Enabled and Disabled (default) Heater 1 Disable Move to next menu item or previous/next configuration menu if "Heater1" is enabled Heater1 Cooldown Disabled Toggle between Enabled and Disabled (default) Heater 1 Cooldown Move to next menu item if "Heater1" is enabled Heater1 Extend Toggle between Enabled and Disabled (default) Heater 1 Extend Disabled Move to previous/next configuration menu if "Heater1" is enabled and 1-speed filter pump is not selected Allow Low Speed Toggle between Enabled and Disabled (default) Disabled Move to next menu item or previous/next configuration menu Heater1 If the heater is "Enabled", the heater relay will turn on when the water temperature is less than the desired temperature setting and the filter pump is running. The desired temperature is in the "Settings Menu". If applicable, the homeowner will be prompted to enter separate "pool" and "spa" settings. Depending on the position of the pool/spa suction valve, the proper temperature setting will be used. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

15
For the Hayward Tristar variable speed pump:
The Filter relay is used to supply input power
to the VSC pump control.
The relay will be on when the filter pump output is on.
When the
filter pump output is off, the relay will be off.
On , off and speed is controlled by commands
sent to the pump.
Lowest Speed
This is the lowest speed that the variable speed pump is allowed to run at. It is used as the
lower limit in the Low Speed Settings Menu. Set lowest speed from 10% (default) to 50%.
Highest Speed
This is the highest speed that the variable speed pump is allowed to run at. It is used as the
upper limit in the High Speed Settings Menu.
Also, this is the speed that the pump will run
at during the first 3 minutes of operation anytime the pump has been off for more than 30
seconds. Set highest speed from 20% to 100% (default).
Freeze Protection
Freeze protection is used to protect the pool and plumbed equipment against freeze damage.
If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold
(see below), the ECOMMAND 4 will turn on the filter pump to circulate the water. If “Pool
and Spa” is selected in the Pool/Spa sub-menu, the valves will also alternate between the
pool and spa every 30 minutes and the filter pump will turn off while the valves are turning.
The chlorinator will not operate if freeze protection is the only reason the pump is running.
Freeze Protection Speed
This menu only appears if freeze protection is enabled and the pump is configured for 2-
speed or variable speed pump operation. This is the speed that the pump will run at during
freeze protection operation. Select high (default) or low speed operation.
Freeze Protection Temperature
Select the temperature to be used for freeze protection.
Temperature is adjustable from 33ºF
-
42ºF (1ºC - 6ºC).
38ºF (3ºC) is default. This threshold will be used for all outputs that have
freeze protection enabled.
Heater1 Config.
+ to view/change
Heater1
Disable
Heater1 Cooldown
Disabled
Heater1 Extend
Disabled
Push to access heater options
Toggle between Enabled and Disabled (default) Heater 1
Toggle between Enabled and Disabled (default) Heater 1 Cooldown
Toggle between Enabled and Disabled (default) Heater 1 Extend
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Heater1” is enabled
if “Heater1” is enabled
Allow Low Speed
Disabled
Toggle between Enabled and Disabled (default)
Move to next menu item or previous/next configuration menu
if “Heater1” is enabled and
1-speed filter pump is not selected
Heater1
If the heater is “Enabled”, the heater relay will turn on when the water temperature is less
than the desired temperature setting and the filter pump is running.
The desired temperature
is in the “Settings Menu”.
If applicable, the homeowner will be prompted to enter separate
“pool” and “spa” settings.
Depending on the position of the pool/spa suction valve, the
proper temperature setting will be used.