Hayward E-Command 4 Model: ALL MODELS Operation - Page 25
Quick How To Guide
View all Hayward E-Command 4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Quick "How To" Guide Operate the Spa-Manually 1. Press the "Pool/Spa" button to go to "spa-only" operation (right LED illuminated). In some cases, this may take more than one press of the button. 2. If the filter pump is not already on, press the "FILTER" button to turn it on. 3. If the spa is below the desired temperature, the heater will turn on automatically when the filter pump is on and the valves are in the spa-only position. If you have not already set the desired temperature for the spa, see "Set Heater Temperature" below. 4. If the spa has a separate jet pump and or blower, determine if the jet pump/blower is controlled by Aux1 or Aux2 (it should be marked on the label inside the door). Then press the appropriate button to turn on the jets/blower. Operate the Spa-Automatically 1. Press the "MENU" button repeatedly until "Timers Menu" is displayed. 2. Press the ">" button repeatedly until the "Spa-all" or "Spa-wkend" is displayed. 3. Use the "+" and "-" buttons to set the desired start time, then press ">" to switch to the off time. Use the "+" and "-" buttons to adjust the off time. If you are setting the "weekend" timeclock, press ">" to go to the "weekday" settings. Note: During the programmed spa time, the valves will automatically switch to the "spa-only" position, the filter pump will turn on, and, if the spa is not up to the desired temperature, the heater will start. This operation is the highest priority and will take precedence over other automatically programmed operations. At the end of the spa period, the ECOMMAND 4 will return to its normally programmed operation state. Set the Heater Temperature (or turn heater permanently off) 1. Press the "MENU" button repeatedly until "Settings Menu" is displayed. 2. Press the ">" button repeatedly until the "Spa Heater1" or "Pool Heater1" is displayed. 3. Press the "+" or "-" buttons repeatedly to adjust the temperature. If you adjust the tempera- ture below 65ºF or above 104°F the display will indicate "off" and the heater will not operate regardless of temperature. Note: Separate temperatures for the pool and spa must be set. If the valves are in the pool-only or spa spillover positions, then the heater will use the pool setting. If the valves are in the spa-only position then the heater will operate according to the spa setting. Set the Chlorinator Output (for external chlorinator) 1. Press the "MENU" button repeatedly until "Settings Menu" is displayed. 2. Press the ">" button repeatedly until the "Spa Chlorinator" or "Pool Chlorinator" is displayed. 3. Press the "+" or "-" buttons repeatedly to adjust the setting. If you adjust the setting to 0% the chlorinator will be off all the time. Note: Separate chlorinator output levels for the pool and spa must be set. If the valves are in the pool-only or spa spillover positions, then the chlorinator will operate according the pool setting. If the valves are in the spa-only position then the chlorinator will operate according to the spa setting. The actual amount of chlorine introduced into the pool/spa is determined by: this output setting, the amount of time the filter pump is running, the water temperature, and the amount of salt in the water. Also see Start/Stop Superchlorination below. 22