Hayward HeatPro Heat Pro Installation

Hayward HeatPro Manual

Hayward HeatPro manual content summary:

  • Hayward HeatPro | Heat Pro Installation - Page 1
    HP20854T, HP20854BT and HP21104T INSTALLATION GUIDE Important Information to keep for Service Model Serial Install Date SAVE THIS INSTALLATION GUIDE The Hayward HeatPro Heat Pump this manual, instructions that are important but not related to hazards. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
  • Hayward HeatPro | Heat Pro Installation - Page 2
    HEATPRO HEAT PUMP IMPORTANT SAFETY INSTRUCTIONS HP13023770 Rev: E READ AND FOLLOW ALL INSTRUCTIONS IN THIS INSTALLATION GUIDE AND ON EQUIPMENT. Before installing or servicing copper bonding wire to the grounding lug provided on the heat pump and to all metal parts of swimming pool or spa, and to
  • Hayward HeatPro | Heat Pro Installation - Page 3
    instructions could result in violent separation of pump components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, filter manual or hot tubs. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC
  • Hayward HeatPro | Heat Pro Installation - Page 4
    is not needed at the heat pump; connections are made inside the heat pump electrical compartment. 4. Electric disconnect switch that will interrupt all power to the unit. This switch MUST be within line of sight of the heat pump. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC
  • Hayward HeatPro | Heat Pro Installation - Page 5
    Page 5 of 20 HEATPRO HEAT PUMP HP13023770 Rev: E Hayward HeatPro Heat Pump Dimensions MODELS: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T Hayward HeatPro Heat Pump Specifications Operating Specification Volts Hertz Phase Compressor Maximum Operating Current Compressor LRA Fan Motor
  • Hayward HeatPro | Heat Pro Installation - Page 6
    • Accessibility of service panels NOTICE - DO NOT install the heat pump unit in a fully enclosed space (i.e. garage, shed etc). Failure to follow this instruction may result in poor performance, property damage, and voided warranty. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons
  • Hayward HeatPro | Heat Pro Installation - Page 7
    through the unit (see above diagram). Failure to follow the instructions may result in property damage and a voided warranty. NOTE: A gutter or down spout may need to be installed to protect the heat pump. Equipment Pad Place the heat pump on a level surface such as concrete or a fabricated slab
  • Hayward HeatPro | Heat Pro Installation - Page 8
    and Condensation HEATPRO HEAT PUMP HP13023770 Rev heads near the heat pump that will spray on or into the unit. Sprinkler damage is not covered under the warranty agreement. Make or salt spray is not covered by the warranty. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC
  • Hayward HeatPro | Heat Pro Installation - Page 9
    anchoring is required to secure the heat pump to concrete pad, use the specified hardware shown in the diagrams below. Use this diagram to tie-down Heat Pump Models: HP20654T, H20654BT, HP20854T, HP20854BT & HP21104T USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN
  • Hayward HeatPro | Heat Pro Installation - Page 10
    instructions for pressure switch adjustment in the heat pump start up section of this manual. If the heat pump is installed outside of this range, an external pressure switch may need to be installed in the plumbing upstream of the heat pump. For more information call Hayward Technical Service at
  • Hayward HeatPro | Heat Pro Installation - Page 11
    piping installation is complete, operate the pool filter pump with the heat pump off. Check the entire piping system for leaks. Observe the filter water pressure gauge for abnormalities or obstructions in the filtering system. Failure to follow the instructions may result in property damage. Flow
  • Hayward HeatPro | Heat Pro Installation - Page 12
    , whose function is to tell the heat pump that the filter pump is running. This pressure switch setting should be adjusted so that the heat pump is running only while the pool filter pump is operating. Adjustment knob USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN
  • Hayward HeatPro | Heat Pro Installation - Page 13
    7 & 8 for more information. 2. Install bypass loops for each unit. 3. Install union style fittings from the heat pump KIT adjacent to the unit to facilitate easy service procedures. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com
  • Hayward HeatPro | Heat Pro Installation - Page 14
    with Solar or Gas Heaters If you are installing a heat pump in combination with any other type of heating device, please call the HAYWARD service department at (908) 355-7995. We will advise you of installation practices that will help keep your warranty valid. Other pool heaters, such as gas-fired
  • Hayward HeatPro | Heat Pro Installation - Page 15
    standards detailed within the NEC. Hayward does not recommend the use of ground fault protective devices in conjunction with heat pumps. Service calls, found to be due to "nuisance" tripping of ground fault devices, are not covered under the factory warranty. CAUTION - An outdoor waterproof
  • Hayward HeatPro | Heat Pro Installation - Page 16
    20 HEATPRO HEAT PUMP HP13023770 Rev: E Wiring Diagrams Refer to the following wiring diagrams for electrical connections. This wiring diagram is for use with all units that have dual digital thermostats without Time Clock Override. Models: HP20654T, HP20654BT, HP20854T, HP20854BT & HP21104T USE
  • Hayward HeatPro | Heat Pro Installation - Page 17
    Page 17 of 20 HEATPRO HEAT PUMP HP13023770 Rev: E Connecting to Remote Systems HAYWARD heat pumps are compatible, in the heating mode only, with one or more of the remote systems in the pool and spa industry today. Thoroughly read all installation instructions of the remote system before
  • Hayward HeatPro | Heat Pro Installation - Page 18
    Page 18 of 20 HEATPRO HEAT PUMP HP13023770 Rev: E Start-Up Procedures 1. Apply power to the pool heater by plugging in the non-fused disconnect block or moving the circuit breaker to the "ON" position. 2. Place the pool heater thermostat in the "Standby" mode by ensuring the light above the "
  • Hayward HeatPro | Heat Pro Installation - Page 19
    Page 19 of 20 HEATPRO HEAT PUMP HP13023770 Rev: E General Troubleshooting Guide for Hayward HeatPro Heat Pump Problem Possible Cause Possible Solution(s) to operate. (refer to Operating section) Call for service. Heat pump is running but is not heating, "Run" light does not come on. Check
  • Hayward HeatPro | Heat Pro Installation - Page 20
    Diagnostic Codes -Troubleshooting Guide for Hayward HeatPro Heat Pump Display (blank) Problem No power to heat pump Faulty electrical component Possible Cause Tripped circuit breaker/ no power supply Solution Check breaker and ensure that the unit is properly installed. Call for service. Unit
  • Hayward HeatPro | Heat Pro Installation - Page 21
    Page 21 of 20 HEATPRO HEAT PUMP HP13023770 Rev: E USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona, CA Clemmons, NC Nashville, TN Tel: 908.351.5400 www.haywardpool.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

HP13023770 Rev: E
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA
Clemmons, NC
Nashville, TN
Tel: 908.351.5400
www.haywardpool.com
Models: HP20654T, HP20654BT, HP20854T,
HP20854BT and HP21104T
INSTALLATION GUIDE
SAVE THIS INSTALLATION GUIDE
Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe
injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following
signal words and be alert to the potential for personal injury.
WARNING
warns about hazards that
could
cause serious personal injury, death or major property damage and if
ignored presents a potential hazard.
CAUTION
warns about hazards that
will
or
can
cause minor or moderate personal injury and/or property damage
and if ignored presents a potential hazard.
It can also make consumers aware of actions that are unpredictable and unsafe.
The
NOTICE
label indicates special instructions that are important but not related to hazards.
The Hayward HeatPro Heat Pump is listed by ETL as complying with the latest edition of the “UL Standard for Safety for
Heating and Cooling Equipment”, UL1995 and CSA C22.2 No. 236.
All Hayward HeatPro Heat Pumps must be installed in accordance with all applicable National and Local codes. In the absence
of local codes, refer to the latest edition of the National Electric Code (NEC) in the United States and the Canadian Electric
Code (CEC) in Canada
Important Information to
keep for Service
Model # ________________
Serial # ____________________
Install Date _________________