    Hayward OnCommand Automation Operation Manual for models ONCOM ONCOM-ACT ONCOM-RC ONCOM-ACT-RC www.haywardnet.com
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 2
    they are closely supervised at all times. • A green colored terminal marked "Earth Ground" is located inside the wiring compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 3
    1 Automation 1 Manual System Operation Filter Pump 2 Lights and Aux Outputs 3 Pool/Spa Valves 3 Service 3 Automatic System Operation (Programming) Using the Programming Buttons 4 Programming Menu Flow Chart 5 Settings Menu 6 Timers Menu 9 Configuration Menu 13 Quick "How To" Guide
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 4
    wired and configured according to the Installation Manual. Aspects of the OnCommand that pertain to system setup are not covered in this manual. Automation The OnCommand can control up to 4 high voltage (120/240V) pieces of equipment, up to 3 automatic valve actuators, and a conventional and solar
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 5
    the main objective of the OnCommand is to automate the operation of your pool/spa system, there may be certain times when you want to override the automatic operation and control the equipment manually. To operate the pool equipment manually while keeping the automation active, perform the following
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 6
    after 3 hours. During service timed operation, the "Service" LED will flash and the time remaining will be displayed on the remote display/keypad(s). Pressing the SERVICE button again, will return the OnCommand to normal (automatic) operation. See Troubleshooting/Diagnostic Information (page 25) for
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 7
    Automatic System Operation The OnCommand controls most of your pool equipment automatically in order to minimize the time spent working on your pool. Most of the pool equipment can be programmed to operate on a timeclock basis. In addition, the desired pool and spa temperatures can be programmed.
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 8
    software revision display software revision filter bridge/vsc software revision RF base software revision configuration menu chlorinator pool/spa filter heater solar lights aux1 aux2 valve3 remote menus 7-day or weekend/weekday timeclock 12 hour or 24 hour time format ºF or ºC reset to default
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 9
    the Configuration menu are included in both the Operation and the Installation Manual. The "Diagnostic Menu" is primarily intended for the service technician and contains information and details about the system operation that are helpful in troubleshooting, if problems occur. Settings Menu The
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 10
    for the balance of the programmed number of hours. Spa Chlorinator 3% Adjust the desired chlorinator output for spa (0,1,2,3...9,10,15,20...95,100%) Move to previous/next menu item This setting will appear only if the system has been setup for external chlorinator and "spa only" or "pool and spa
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 11
    Use this function to set the current day of the week and time. These values are used for all the automatic timeclock functions of the OnCommand and are also displayed as part of the default menu. The OnCommand is designed to keep the clock running during power outages lasting less than 7 days. If
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 12
    pool/spa system. The OnCommand has 4 timeclocks available for each function. Each timeclock has a single on/off program per day. All of the timeclocks are programmed in the Configuration Menu either as "all days" or "weekends/weekdays". If "weekends/weekdays" are selected, the start and stop times
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 13
    6:00P to 9:00P Adjust time setting Move between start and stop times & to previous/next menu item This menu is only available if the system has been setup for "pool and spa". Only one timeclock is available for Spa operation. During the programmed spa time, the OnCommand will turn on the filter
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 14
    setting Move between start and stop times & to previous/next menu item This menu will appear only if the Aux1 is configured for timeclock. The Aux output will turn on and off or at the designated times. If the Aux relay is off during the programmed on time- note that some pool equipment (example
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 15
    of commands that are programmed in the Configuration Menu. For example, instead of the Lights button turning on and off the pool light only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, and turn on the music all at the same time. This
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 16
    a Hayward Swimpure or Goldline Aqua Rite chlorinator is used, the OnCommand can be programmed to Super Chlorinate the pool or spa while running a group command. When the group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the preset time expires (see Timers Menu
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 17
    and sanitized. If "Pool Only" is selected, then the OnCommand will switch the pool/spa valves to the "pool only" position at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on. This may be desirable on some systems with in-floor cleaners
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 18
    is configured, one of the AUX relays must also be configured to control the low speed motor winding on the pump. Refer to the appropriate sections in the Installation manual for specific information regarding the control logic for 2-speed and variable speed pump operation. For the Hayward Tristar
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 19
    Move to next menu item or previous/next configuration menu Heater If the heater is "Enabled", the heater relay will turn on when logic keeps the filter pump running beyond the normal turn-off time until the pool (or spa) is heated up to the desired temperature setting (see Settings Menu). Heater
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 20
    the turn off time when solar is operating. Solar Priority If both "Solar Control" and "Heater Control" are enabled, the Solar Priority feature will keep the conventional heater off whenever solar heat is available. This provides the most cost effective way of heating the pool. When solar heat is not
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 21
    the times set for the lights timeclock in the Timers Menu (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output on and off. Solar - the lights relay can operate a solar booster pump which will turn on when the filter pump is running and solar heat is available
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 22
    ) and the desired pump speed Move to previous/next configuration menu ! WARNING: Do not use the OnCommand to control an automatic pool cover. Swim- mers may become entrapped underneath the cover. Aux1 Function Manual On/Off (default)-the aux relay will alternate between turning on and off when the
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 23
    filter pump is running and solar heat is available and the water is less than the desired temperature setting. It is important to note that "Solar Control" must be enabled in the "Solar Config." menu for proper operation to occur. Group - the aux relay operates when the Group function is initiated
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 24
    pump speed Move to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running and solar heat is available and the water
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 25
    to previous/next configuration menu Use this function to erase all previous system configuration and reset all configuration parameters back to the factory default values. This function is NOT reversible--be careful. Quick "How To" Guide Operate the Spa-Manually 1. Press the "Pool/Spa" button to
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 26
    . Note: During the programmed time, there may be other automatic or manual operations that prevent the relay/valve from operating-see a more detailed discussion under Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diagnostic Information. Program a Countdown Timer 1. Press
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 27
    the end of the 3 hour time period. Troubleshooting and Diagnostic Information The OnCommand provides 2 different tools to aid in troubleshooting any problems that may occur in your pool and/or spa system. The Service mode will allow you to disable automatic operation and manually control most of the
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 28
    the Pool Filter and the Hayward VSC is indicating and error. x is the same decimal error displayed by the VSC itself. For helpful troubleshooting information on any of these issues, go to the Diagnostic Menu and then scroll through the various items until you see the cause for the "CHECK SYSTEM" LED
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 29
    to previous/next menu item Available displays depend on configuration. If you call the Hayward/Goldline Technical Service Dept. for assistance, they may ask for the software revisions of both the main unit and each of the display/keypads or other devices that are attached to the system. Note that it
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 30
    27
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 31
    date of installation of the product. To obtain warranty service or repair, please contact the place of purchase or the nearest Hayward/Goldline authorized warranty service center. For more information on authorized service centers please contact the Hayward/Goldline Technical Service Support Center
  • Hayward OnCommand | Model: ALL MODELS Operation - Page 32
    620 Division St. Elizabeth, NJ 07207 092442A Copyright © 2009 Hayward
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Hayward
OnCommand
Automation
Operation Manual
ONCOM
ONCOM-ACT
ONCOM-RC
ONCOM-ACT-RC
www.haywardnet.com
for models