Hayward Perflex Extended-Cycle Instruction Manual

Hayward Perflex Extended-Cycle Manual

Hayward Perflex Extended-Cycle manual content summary:

  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 1
    ISEC40C90 Rev. A OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Perflex Extended Cycle Filtration System EC40C90 Series The Hayward® Perflex™ Filtration System is specifically designed for the demanding requirements of today's above-ground swimming pools. The advanced design reduces maintenance
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 2
    Perflex™ Extended Cycle Filtration System__________ PRODUCT REGISTRATION (Retain For Your Records) ________ DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When installing and using this
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 3
    Perflex™ Extended Cycle Filtration System__________ NOTE: The National Electrical Code (NEC) permits use of a cord with Hazardous Pressure. Pumps, filters, and other equipment/components of a swimming pool filtration system operate under pressure. Incorrectly installed and/or improperly tested
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 4
    Perflex™ Extended Cycle Filtration System General Information Introduction This manual contains information for the proper installation and operation of the Hayward® Perflex™ Filtration System. All Perflex™ Filtration models are high performance, above-ground swimming pool filters. Instructions
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 5
    Perflex™ Extended Cycle Filtration System Installation Instructions System Location For best pump performance, the system MUST be located below the pool water line (See Figure to the right). Install the system on a firm, level base or pad to meet all local and national codes. The field
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 6
    Perflex™ Extended Cycle Filtration System Prior to Start-Up Before Starting the Filter System 1. Obtain a supply of operating chemicals, D.E., and a pool test kit. Use only the swimming pool grades of D.E., such as: CELATOM (Eagle-Picher Industries, Inc.) AQUA-CEL (Johns-Manville Products
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 7
    Perflex™ Extended Cycle Filtration System Start-Up & Operation Starting the Filter Close the filter drain and the vent valve. CAUTION - All suction and outlet valves MUST be OPEN before operating the filter system of the filter. (Note: If the filter is installed below the pool water line,
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 8
    Perflex™ Extended Cycle Filtration System Perflex filters are basically resistant to the difficulties often encountered as a result of chemical build-up in swimming pools cycle the filter as described under "Cleaning". Service & Repairs Consult your local authorized Hayward-Perflex dealer or service
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 9
    Perflex™ Extended Cycle Filtration System Troubleshooting Problem Running at high pressures. Drop off of return flow. Short cycles. Probable Cause D.E. coated with normal accumulation of pool . Consult pump and motor troubleshooting guide. Note: Most motor problems are due to: 1. Undersized
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 10
    Perflex™ Extended Cycle Filtration System Troubleshooting (cont.) Problem Short cycles - even after proper Bump-Drain-Recharge (or filter cleaner-type preparations) to chemically dissolve contaminates. Consult your pool dealer for chemical cleaning instructions. D.E. leaking to pool via the
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 11
    Perflex™ Extended Cycle Filtration System Replacement Parts Parts Diagram Parts Listing Ref. No. Part No. 1 ECX10066 2 ECX5000BP 3 ECX4034 4 ECX4000C 5 ECX4000CHK 6 ECX1014A 7 ECX1037B 8 ECX4236A 9 ECX5000F 10 ECX1004 11 ECX5000G 12 ECX1031
  • Hayward Perflex Extended-Cycle | Instruction Manual - Page 12
    Perflex™ Extended Cycle Filtration System HAYWARD® LIMITED WARRANTY This filter system was inspected before shipment from our plant. To original purchasers of this filter system, Hayward Pool Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its products free from defects in
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

ISEC40C90
Rev. A
____________________________________________________________________________________
OWNER’S MANUAL
INSTALLATION, OPERATION, & PARTS
Perflex
Extended Cycle
Filtration System
EC40C90 Series
The Hayward
®
Perflex™ Filtration System is specifically designed for the demanding requirements of today’s above-ground
swimming pools.
The advanced design reduces maintenance requirements while providing superior performance.
To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.
CAUTION
We highly recommend a qualified professional install and service this product.
WARNING
This manual contains important safety information that must be furnished to the end
user of this product.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN
SERIOUS INJURY.
SAVE THIS INSTRUCTION MANUAL
HAYWARD POOL PRODUCTS, INC.
Corporate Headquarters:
U.S.A:
620 Division Street
1 Hayward Industrial Drive
2935 Sidco Drive
2875 Pomona Blvd.
Elizabeth, NJ 07207
Clemmons, NC 27012
Nashville, TN 37204
Pomona, CA 91768
Canada:
Europe:
2880 Plymouth Drive
Parc Industriel de la plaine de l'Ain
Oakville, Ontario L6H 5R4
Allêe des Chênes
01150 Saint Vulbas
France