    ISPF SERIES Rev. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series are specifically engineered for the demanding requirements of today's above-ground swimming pools. The advanced design reduces
  • Hayward Power-Flo | Model: ALL - Page 2
    Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment,
  • Hayward Power-Flo | Model: ALL - Page 3
    Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use of a cord with a maximum 3 ft. (1 m) length. If your pump is equipped with a cord complying with or test the filtration system at more than 30 PSI. SAVE THESE INSTRUCTIONS
  • Hayward Power-Flo | Model: ALL - Page 4
    Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to right). Self-priming Power-Flo II™ pumps may be installed up to four (4) feet above the pool water line. Install pump servicing pump
  • Hayward Power-Flo | Model: ALL - Page 5
    Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions power to motor before working on electrical connections. WARNING - Ground Fault Circuit Interrupter (GFCI) tripping indicates electrical problem Connect motor ground terminal to electrical service ground. Bond motor to pool
  • Hayward Power-Flo | Model: ALL - Page 6
    Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical (cont.) Wiring (cont.) In case of a power outage, check GFCI for tripping, which will prevent normal pump operation. Reset if necessary. NOTE: If you do not use conduit when wiring motor, be sure to seal wire
  • Hayward Power-Flo | Model: ALL - Page 7
    -Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING - Explosion Hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump
  • Hayward Power-Flo | Model: ALL - Page 8
    Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme care in handling pump. Troubleshooting Motor Will NOT Start - Check For: 1. Improper or loose wiring connections; open switches or relays; tripped circuit breakers, GFCI's, or blown fuses. 2. Manually
  • Hayward Power-Flo | Model: ALL - Page 9
    Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - Check For: 1. Centrifugal switch stuck in OPEN position. 2. Binding of motor shaft. Pump Won't Prime 1. Make sure pump/strainer housing is filled with water and the cover O-ring is clean, also be
  • Hayward Power-Flo | Model: ALL - Page 10
    Power-Flo LX™ / Power-Flo II™ Pump Series Replacement Parts Parts Diagram Parts Listing Ref. No. Description Model No , change "1" in suffix of model number to a "2" (i.e. SPX1510Z2E) Model No. SP1750, 1775, 1780 SPX1500N2 (6 Req'd.) SPX1705B SPX1580Z1 SPX1500H SPX1500KA Refer to Part No. on
  • Hayward Power-Flo | Model: ALL - Page 11
    Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from our plant. To original purchasers of this pump, Hayward authorized Hayward service center. For further Hayward dealer or service center information, contact Hayward customer service
  • Hayward Power-Flo | Model: ALL - Page 12
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

ISPF SERIES
Rev. C
_____________________________________________________________________________________
OWNER’S MANUAL
INSTALLATION, OPERATION, & PARTS
Power-Flo LX™
/
Power-Flo II™
Pump Series
The Hayward
®
Power-Flo LX™ and Power-Flo II™ Pump Series are specifically engineered for the demanding requirements
of today’s above-ground swimming pools.
The advanced design reduces maintenance requirements while providing superior
performance.
To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.
CAUTION
We highly recommend a qualified professional install and service this product.
WARNING
This manual contains important safety information that must be furnished to the end
user of this product.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT
IN SERIOUS INJURY.
*Only units equipped with 3' twist-lock cords
or furnished without a cord for permanent
wiring are UL-Listed.
SAVE THIS INSTRUCTION MANUAL
HAYWARD POOL PRODUCTS, INC.
Corporate Headquarters:
U.S.A:
620 Division Street
1 Hayward Industrial Drive
2935 Sidco Drive
2875 Pomona Blvd.
Elizabeth, NJ 07207
Clemmons, NC 27012
Nashville, TN 37204
Pomona, CA 91768
Canada:
Europe:
2880 Plymouth Drive
Parc Industriel de la plaine de l'ain
Oakville, Ontario L6H 5R4
Allêe des chênes
01150 St Vulbas
France