Hayward Pro Logic® Model: PL-P-4 Operation

Hayward Pro Logic® Manual

Hayward Pro Logic® manual content summary:

  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 1
    Pro Logic® Automation and Chlorination Operation Manual for model PL-P-4 www.haywardnet.com
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 2
    FOLLOW ALL INSTRUCTIONS • ! WARNING: Disconnect all AC power during installation. • connect the local common bonding grid in the area of the swimming pool, spa, or hot tub to these terminals with an insulated or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada. • All field installed
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 3
    Aux Outputs 4 Pool/Spa Valves 4 Service 4 Automatic System Operation (Programming) Using the Programming Buttons 5 Programming Menu Flow Chart 6 Settings Menu 7 Timers Menu 10 Configuration Menu 13 Maintenance Menu 23 Quick "How To" Guide Operate the Spa - Manually 24 Operate the Spa
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 4
    Chlorinator Cell 240 VAC Power Circuit Breaker Subpanel NOTE: This manual assumes that the Pro Logic has been wired and configured according to the Installation Manual. Aspects of the Pro Logic that pertain to system setup are not covered in this manual. Automation The Pro Logic can control up
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 5
    , temperature, and the pool's cleanliness. For pools larger than 40,000 gallons, the Pro Logic can control one or more Hayward Aqua Rite chlorinators to supplement chlorine production. NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 6
    Manual System Operation While the main objective of the Pro Logic is to automate the operation of your pool/spa system, there may be certain times when you want to override the automatic operation and control the equipment manually. To operate the pool equipment manually while keeping the automation
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 7
    over Freeze Protection for Valve outputs Service The main unit keypad has a SERVICE key. This button is used primarily during servicing of the pool equipment. If you want to completely disable the automatic operation and operate the system manually, you can put the system into Service or Service
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 8
    Automatic System Operation The Pro Logic controls most of your pool equipment automatically in order to minimize the time spent working on your pool. Most of the pool equipment can be programmed to operate on a timeclock basis. In addition, the desired pool and spa temperatures and pool and spa
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 9
    timers menu diagnostic menu configuration menu day and time water temperature air temperature chlorinator setting salt level reason pump is running (not scheduled) inspect cell reason hi-speed is running (not scheduled) countdown time remaining heater control status system manual off check system
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 10
    you will be using most often to adjust the operation of your pool. The Configuration Menu is used when the system is installed and defines what equipment is connected to each output and the operational logic that will control the equipment. This menu is normally "locked" and should only be used by
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 11
    running due to the freeze protection feature, then the chlorinator will not operate during this time. Pool Chlorinator 60% Adjust the desired chlorinator output for pool (0,1,2,3...9,10,15,20...95,100%) Move to previous/next menu item This setting will appear only if the system has been setup for
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 12
    timeclock functions of the Pro Logic and are also displayed as part of the default menu. The Pro Logic is designed to keep the clock running during power outages lasting less than 7 days. If power has been off for longer than 7 days, then the time may have to be reset. Display Light On for 60 sec
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 13
    station is connected to the Pro Logic. Timers Menu The Timers Menu allows you to set all timeclock and countdown timers which control the automatic operation of your pool/spa system. Each timeclock has a single on/off program per day. All of the timeclocks are setup (Configuration Menu) either as
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 14
    menu item For one speed pumps, this is the first filter timeclock and will determine the normal hours of filtration for the pool. For pool/spa combination systems . These include super-chlorination, spa operation, manual operation, heater cooldown, freeze protection, heater-extend and solar-extend.
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 15
    turn on the lights until the Pro Logic automatically turns off the lights. You can also manually turn off the lights at an earlier time by pressing the LIGHTS button. If the Lights relay is on during the programmed off time, it may be because of freeze protection. Aux1 and Aux2 configurations are
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 16
    enabled, the Pro Logic will automatically detect and control any Aqua Rite(s) that is installed in the system. Display Allows for the display of salt (default) or mineral values. Cell Type Selection The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu. The
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 17
    be connected to the Pro Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa operation. Spa CountDn This menu will appear only if Pool/Spa Setup is set to "Pool and Spa". This setting is the time, after you manually switch the Pool/Spa
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 18
    the pool and spa every 30 minutes and the filter pump will turn off while the valves are turning. The chlorinator will not operate if freeze protection is the only reason the pump is running. Freeze Protection Speed This menu only appears if freeze protection is enabled and the pump is configured
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 19
    forced off when the external input is active. Note that freeze protection will have precedence over this feature. Heater1 Config. + to view/change Push to access heater options Move to previous/next configuration menu Heater1 Toggle between Enabled and Disabled (default) Heater 1 Disable Move
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 20
    between Enabled and Disabled (default) Move to next menu item or previous/next configuration menu Solar If the solar control logic is "Enabled", several additional steps must be taken to ensure proper operation of the solar system. If the solar is operated by a valve, then the Valve3 output must be
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 21
    turn off automatically after a programmed time (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output off. Low Speed of a 2-speed Filter Pump - the Pro Logic will turn on the lights relay whenever the low speed operation of the filter pump is required. It is
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 22
    falls below the selected freeze temperature threshold, the Pro Logic will energize the lights relay. IMPORTANT: this only enables operation of the lights relay during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Lights Pump Speed This is
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 23
    the selected freeze protection temperature, the Pro Logic will turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the AUX output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Freeze Protection is
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 24
    the selected freeze temperature threshold, the Pro Logic will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of the valve3 output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Valve3 Pump
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 25
    -SS-6B is detected at power up. Select which of the available remote controls (A, B or C) is to be configured. 6B A, Button 1 This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 26
    to the AQL-CHEM ORP and pH sensing kit. pH Calibration Wizard, + to enter Push to access pH Calibration Wizard Move to previous/next menu item Use this Wizard to calibrate the AQL-CHEM's pH probe. This requires a manual pH test of the pool water using a dependable red phenol test kit. Clean Probe
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 27
    period, the Pro Logic will return to its normally programmed operation state. Set the Heater Temperature (or turn heater permanently off) 1. Press the "MENU" button repeatedly until "Settings Menu" is displayed 2. Press the ">" button repeatedly until the "Spa Heater1" or "Pool Heater1" is displayed
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 28
    operations that prevent the relay/valve from operating-see a more detailed discussion under Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diagnostic Information. Enter/Exit Service (or Service-Timed) Mode 1. Go to Pro Logic main unit (normally mounted near the pool
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 29
    using the chlorinator features on the Pro Logic Control. If you are NOT using the chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to the description of the Pro Logic configuration menu for information on enabling/disabling the chlorinator
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 30
    not have new water, add metal remover and non-copper based algaecide to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer to the Pro Logic system. Salt (When using optional chlorinator function) Salt Level Use the chart on the following page to determine how much
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 31
    POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM Current salt Gallons and (Liters) of Pool/Spa water level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 32
    POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR 80 PPM Gallons and (Liters) of Pool/Spa water Current Stabilizer Level (ppm) 8,000 (30000) 10,000 (37500) 12,000 (45000) 14,000 (52500) 16,000 (60000) 18,000 (67500) 20,000 (
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 33
    500 hours of operation. The Pro Logic electrolytic cell has a self cleaning feature incorporated into the electronic control's logic. In most cases this self cleaning action will keep the cell working at optimum efficiency. In areas where water is hard (high mineral content) or in pools where the
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 34
    and Diagnostic Information The Pro Logic provides 2 different tools to aid in troubleshooting any problems that may occur in your pool and/ or spa system. The Service mode will allow you to disable automatic operation and manually control most of the equipment (the heater and general purpose
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 35
    is too low. • No Cell Power -- If no chlorinator cell power is detected on the printed circuit board. • Check Flow Switch -- If the flow switch input is invalid. • Cell Power Error -- If a chlorinator cell power error is detected on the printed circuit board. • Cell Missing -- If the chlorinator is
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 36
    heater is operating, it is likely that the temperature of the water at the cell is higher than the pool/spa water temperature displayed on the Pro Logic default display. Instant Salt 3200 PPM (+=save) Press to load the "Instant Salt" into the averaged salt display Move to previous/next menu item
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 37
    Circuit" then check the wiring to the sensor and also make sure that the wires are secure in the terminal block in the Pro Logic main unit. if EcoStar VSPs are detected VSP Speed/Power ± to view Filter Push to view the actual speed and power reported by the VSP Move to previous/next menu item No
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 38
    Move to previous/next menu item Available displays depend on configuration. If you call the Hayward Technical Service Dept. for assistance, they may ask for the software revisions of both the main unit and each of the display/ keypads or other devices that are attached to the system. Note that it
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 39
    WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three
  • Hayward Pro Logic® | Model: PL-P-4 Operation - Page 40
    2700 - 3400 ppm Add salt as required to increase. Stabilizer 60 - 80 ppm Add cyanuric acid to increase. Calcium 200 - 400 ppm Add calcium to increase. Drain and add water to decrease. Electrolytic Cell inspect & clean Refer to section in manual. Quarterly 620 Division St. Elizabeth, NJ 07207
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Automation and Chlorination
Operation Manual
for model
PL-P-4
Pro Logic
®
www.haywardnet.com