Hayward Pro Logic® Model: AQL-CHEM-3 Installation and Operation
Hayward Pro Logic® Manual
View all Hayward Pro Logic® manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward Pro Logic® manual content summary:
- Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 1
Total Pool Chemistry TM for Aqua Rite® Pro and Pro Logic ® Installation and Operation Manual AQL-CHEM-3-120 AQL-CHEM-3-240 www.haywardnet.com - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 2
water each day! Check the pool chemistry and pool controller alarm status prior to entering the pool or spa. Resolve any issues prior to entering the water. • Keep equipment maintained! The pump tube must be replaced annually to avoid wear out and leaks. The system should be inspected annually - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 3
AQL-CHEM-3-120 (120VAC) and AQL-CHEM-3-240 (240VAC) are compatible with all Hayward Aqua Rite Pro and Pro Logic pool controls using an AQL-CHEM Sense & Dispense system. The AQL-CHEM-3 is not compatible with Aqua Rite or Aqua Logic controls. Description The AQL-CHEM-3 is an automatic acid dispensing - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 4
water chemistry, which at worst, could harm people or equipment. • Check the Aqua Rite Pro or Pro Logic's display each day before entering the water. If there is any Check System alarm, follow the troubleshooting guide in this manual to understand and rectify the condition. If the display is blank - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 5
of the AQL-CHEM-3 requires: • Setup and installation of the Stenner pump/tank • Installation of the Feed Tube and Injector assembly to the return plumbing • Connection of the AQL-CHEM-3 to the pool control • Programming the pool control for use with the AQL-CHEM-3 • Filling the Stenner pump - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 6
-CHEM-3. Discard the shorter injector as it does not included a flow-check system and must not be used. The correct injector has a flow direction indicator as shown in the diagram below. Cut a 2" piece of 1/4" tubing to connect the injector to the flow indicator. With the fittings loose, insert the - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 7
. If the pigtail isn't already installed, refer to the AQL-CHEM product manual for installation instructions. Program the Aqua Rite Pro or Pro Logic The pool control must now be programmed to operate the AQL-CHEM-3. Refer to the Aqua Rite Pro or Pro Logic operation manual for specific programming - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 8
• The homeowner has been instructed on the use and safety of the system Operation Enable the Stenner pump by putting the toggle switch in the ON position according to the diagram below. Remove Roof Switch must be in "ON" position Reinstall the protective roof for normal operation. Purge air out of - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 9
on the pump. Refer to Stenner pump manual for additional instructions relating directly to the pump operation and service. Troubleshooting If the tank is full but the pool's pH is not adjusting or if the pool control continues to show a "pH timeout" indication: • Check flow indicator for proper flow - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 10
9 - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 11
WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three - Hayward Pro Logic® | Model: AQL-CHEM-3 Installation and Operation - Page 12
Work less, play moreTM with chemistry automation. 620 Division St. Elizabeth, NJ 07207 092438A RevB Copyright © 2010 Hayward
Tot
ot
ot
ot
otal
al
al
al
al P
P
P
P
Poo
oo
oo
oo
ool C
C
C
C
Chemi
hemi
hemi
hemi
hemistry
Aqua Rite Pro
Aqua Rite Pro
Aqua Rite Pro
Aqua Rite Pro
Aqua Rite Pro
Pro Logic
Pro Logic
Pro Logic
Pro Logic
Pro Logic
Installation and Operation
Manual
AQL-CHEM-3-120
AQL-CHEM-3-240
and
for
TM
®
www.haywardnet.com
®