    Total Pool ChemistryTM for Aqua RiteTM Pro and Pro Logic® Installation and Operation Manual for AQL-CHEM June 2010 Download and use the latest manual at: www.hayward-pool.com
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 2
    The AQL-CHEM is an ORP and pH sensing kit that is offered as an accessory for all Hayward Aqua Rite Pro chlorine generators and Pro Logic pool controls. With the AQL-CHEM, the Aqua Rite Pro or Pro Logic can provide a fully integrated chemistry solution for your pool. The AQL-CHEM continuously
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 3
    is not compatible with Aqua Rite or Aqua Logic controls. Installation Overview Installing the AQL-CHEM requires the following steps: • Mounting the Probe Cell • Plumbing the Probe Cell • Installing ORP and pH probes • Wiring probes to Probe Cell communication box • Wiring the Probe Cell to the Aqua
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 4
    the Aqua Rite Pro enclosure. Refer to the diagram below. metal washer rubber washer Aqua Rite Pro enclosure wall Side Mounting AQL-CHEM to Aqua Rite Pro AQL-CHEM bracket wall Route probe cell cable through access hole BEFORE mounting. Zip Tie and store extra cable length here Pro Logic Side
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 5
    Remote surface mounting the AQL-CHEM: The Probe Cell can be mounted up to 15' away from the Aqua Rite Pro or the Pro Logic (limited by length of cable). Use
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 6
    polyethylene tubing (PEX). Installing ORP and pH probes to the Probe Cell The ORP and pH probes are shipped "wet" in plastic storage caps. It's very important that the probes remain wet at all times. If the probes are allowed to dry out, they will fail and the AQL-CHEM will be ineffective. After
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 7
    Wiring the probes to the Probe Cell Both probes must be wired to the communication box within the Probe Cell. The probe cables use typical BNC connectors that attach to the designated connectors on the communication box. Refer to the label on the communication box for the appropriate connections.
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 8
    (120VAC and 240VAC) are included with the AQL-CHEM sensing kit to be used with pH dispensing devices (peristaltic pumps, solenoid valves, etc.) that require a plug-in receptacle, including the Hayward AQL-CHEM2 and AQL-CHEM2240. If your pH dispensing device will be direct wired (hardwired), the
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 9
    PS-4 models: The factory installed relays can not be used. The relay included with the AQL-CHEM kit must be installed and used to control the pH dispensing device on these models. Installation instructions for this relay can be found packaged with the relay. Once installed, wire the pigtail directly
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 10
    Line on GFCB Pigtail 120 VAC GFCB use watertight strain relief here 120VAC pH dispense Pigtail (included with AQL-CHEM) to AQL-CHEM2 Pro Logic operating with software version 4.00 or later Pro Logics operating with software version 4.00 or later have built-in support for the AQL-CHEM2 or other
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 11
    AQL-CHEM. pH Reduction Control Select the desired option related to pH control. Disabled pH control is turned off. Select this mode if no pH pH reducer pH level from rising. (CO2 or acid) when necessary to prevent the Forced On pH reducer is added for 15 minutes regardless of pH
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 12
    to maintain a desired level. Timed (%) The chlorine output is based on the manual setting only. ORP level is not used to control the chlorinator output. Maintain pH Level The Wizard prompts you to enter the desired pH level (7.5 default). The Aqua Rite Pro or Pro level. Logic will dispense
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 13
    the pH probe per the instructions found in the Probe Maintenance section of this manual. Configuring the pH Dispense Relay (Pro Logics operating with software ver- sion less than 4.00) IMPORTANT: The relay used to control the AQL-CHEM2(-240) or other pH dispens- ing device needs acid into
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 14
    for the pH Dispensing device. The device SHOULD NOT TURN ON. If it does, go back through the configuration to determine the problem. Operation Before operating the AQL-CHEM, test and adjust the pool water chemistry to the recommended levels in the Aqua Rite Pro or Pro Logic Operation manuals. This
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 15
    equipment. • Check the Aqua Rite Pro or Pro Logic's display each day before entering the water. If there is any Check System alarm, following the troubleshooting guide in this manual to understand and rectify the condition. If the display is blank, or reporting a communications error
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 16
    also be found within the Diagnostic Menu. The desired ORP and pH levels can be changed by restarting the Chemistry Config. Wizard. Maintenance Water Chemistry Always test water chemistry with a quality manual test kit. The AQL-CHEM provides instrument grade accuracy which exceeds that of most liquid
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 17
    Winterizing The AQL-CHEM probes must be protected from freezing conditions. If the pool is winterized, plan to remove and store the caps, BNC covers, and other necessary winterizing accessories is available to replace any missing items. Contact your local Hayward dealer for more information. 16
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 18
    17
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 19
    Hayward/Goldline authorized warranty service center. For more information on authorized service centers please contact the Hayward/ Goldline Technical Service Support in accordance with the recommendations in the owners manual(s). 5. Problems resulting from tampering, accident, abuse, negligence,
  • Hayward Sense and Dispense | Model: AQL-CHEM - Page 20
    Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. Work less, play moreTM North Kingstown, RI 02852 USA 092332E RevG Copyright © 2010 Hayward
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

June 2010
Download and use
the latest manual at:
www.hayward-pool.com
Total Pool Chemistry
Aqua Rite Pro
Pro Logic
Installation and Operation Manual
for
AQL-CHEM
and
for
TM
TM
®