    GLX-CELL-15-W NEW MENU SETTING MAY BE REQUIRED! The T-CELL-15 and GLX-CELL-15-W are designed for pools up to 40,000 gallons. When replacing an existing T-CELL-15 or GLX-CELL-15, no re-configuration is neccessary. Configuration of your controller may be required before using the T-CELL-15 or GLX-CELL
  • Hayward Turbo Cell | Model: T-CELL-15 - Page 2
    cycles, and Low Flow Rate conditions THE AMOUNT OF CHLORINE PRODUCED BY YOUR HAYWARD/GOLDLINE SALT CHLORINE GENERATING CELL IS RECEIVING ADEQUATE FLOW. Low flow conditions can result in insufficient water in the cell causing inefficient chlorine production. As a precaution, the cell can be installed
  • 1
  • 2

T-CELL-15
GLX-CELL-15-W
NEW MENU SETTING
MA
Y BE REQUIRED!
The T-CELL-15 and GLX-CELL-15-W are designed for pools up to 40,000 gallons. When
replacing an existing T-CELL-15 or GLX-CELL-15, no re-configuration is neccessary.
Configuration of your controller may be required before using the T-CELL-15 or GLX-CELL-15-W
chlorinator cell.
Refer to the information below. Incorrect configuration will cause inaccurate salt
readings, improper operation, and possible system shutdown.
CONFIGURATION is necessary with the following models:
AQR (Aqua Rite - all 2009 or later) - firmware version 1.5 or later
AQR-PRO (Aqua Rite Pro)
PL-P-4 (Pro Logic P4)
PL-PS-x (Pro Logic PS)
AQ-LOGIC-P-4 (Pro Logic P4)
AQ-LOGIC-PS-x (Pro Logic PS)
NO CONFIGURATION is neccessary with the following models:
AQ-RITE (Aqua Rite - 2008 and earlier) - firmware earlier than version 1.5
AQ-RITE-XL (Aqua Rite XL)
Connecting to an AQR:
1.
Slide the Main Switch to the "Auto" position.
2.
Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory
default). If “t-15” is displayed, skip to step 4.
3.
To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto".
Repeat this process until the “t-15” is displayed.
4.
Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1.
Access the Settings Menu by pushing the “Settings” button.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
Push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Info” button.
Connecting to an AQ-LOGIC-P-4, AQ-LOGIC-PS-x, PL-P-4 or PL-PS-x:
1.
Enter the Configuration Menu.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Menu” button.