Hayward TurboCell Salt Chlorination Cell TCELL940 Manual 092625 Rev A
Hayward TurboCell Salt Chlorination Cell Manual
View all Hayward TurboCell Salt Chlorination Cell manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward TurboCell Salt Chlorination Cell manual content summary:
- Hayward TurboCell Salt Chlorination Cell | TCELL940 Manual 092625 Rev A - Page 1
existing T-CELL-15, GLX-CELL-15, TCELL940 or TCELL940-W, no re-configuration is necessary. Configuration of your controller may be required before using the TCELL940 or TCELL940-W chlorinator cell. Refer to the information below. Incorrect configuration will cause inaccurate salt readings, improper - Hayward TurboCell Salt Chlorination Cell | TCELL940 Manual 092625 Rev A - Page 2
OR VARIABLE SPEED PUMPS ON LOW SPEED, CHECK TO BE SURE YOUR SALT CELL IS RECEIVING ADEQUATE FLOW. Low flow conditions can result in insufficient water in the cell causing inefficient chlorine production. As a precaution, the cell can be installed vertically or in an inverted manner (see illustration
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
092625 RevA
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
TCELL940
TCELL940-W
MENU SETTING MAY BE REQUIRED!
The TCELL940 and TCELL940-W are extended life cells designed for pools up to 40,000 gallons. When replacing an existing T-CELL-15,
GLX-CELL-15, TCELL940 or TCELL940-W, no re-configuration is necessary.
Configuration of your controller may be required before using the TCELL940 or TCELL940-W chlorinator cell. Refer to the information below.
Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown.
CONFIGURATION is necessary with the following models:
•
AQR (Aqua Rite - all 2009 or later) - firmware version 1.5 or later
•
AQR-PRO (Aqua Rite Pro)
•
PL-P-4 (Pro Logic P4)
•
PL-PS-x (Pro Logic PS)
•
AQ-LOGIC-P-4 (Pro Logic P4)
•
AQ-LOGIC-PS-x (Pro Logic PS)
•
AQR900 series - all
NO CONFIGURATION is necessary with the following models:
•
AQ-RITE (Aqua Rite - 2008 and earlier) - firmware earlier than version 1.5
•
AQ-RITE-XL (Aqua Rite XL)
Connecting to an AQR or AQR900:
1.
Slide the Main Switch to the “Auto” position.
2.
Push the Diagnostic button repeatedly until “t-xx” appears on the display (“t-15” is the factory default). If “t-15” is displayed, skip to
step 4.
3.
To change cell type, slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”.
Repeat this process until the “t-15” is
displayed.
4.
Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1.
Access the Settings Menu by pushing the “Settings” button.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
Push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Info” button.
Connecting to an AQ-LOGIC-P-4, AQ-LOGIC-PS-x, PL-P-4 or PL-PS-x:
1.
Enter the Configuration Menu.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Menu” button.