Page 92 highlights
Service Tests and Utilities 2 The test will start and the following message will appear on the front panel: SCAN AXIS Running Scan Axis Test... (takes 2mn...) 3 Once the test is completed, the following message will appear on the front panel: SCAN AXIS FORWARD Avg PWM: XXX Max PWM: XXX Stabilizat Dist: XXXX Avg speed offset: XXX STD speed offset: XXX 4 Press Enter and the following message will appear on the front panel: SCAN AXIS BACKWARDS Avg PWM: XXX Max PWM: XXX Stabilizat Dist: XXXX Avg speed offset: XXX STD speed offset: XXX To check if the values displayed after the test are within the limits, refer to the following table: Scan-Axis Forward Scan-Axis Backwards Normal Maximum Normal Maximum Avg. PWM 165 185 -165 -185 Max. PWM 220 240 220 240 Stabilize Dist. 1800 2400 1800 2400 Avg. Speed offset 2.4 10 2.4 10 STD Speed offset 4.4 10 4.4 10 4-18 HP DesignJets 1050C and 1055CM Printers Service Manual