A Specifications Table A-1 Specifications Desktop Dimensions Height 14.85 in 37.72 cm Width 6.95 in 17.65 cm Depth 16.85 in 42.80 cm Approximate Weight 23.5 lb 10.66 kg Temperature Range Operating 50° to 95°F 10° to 35°C Nonoperating -22° to 140°F -30° to 60°C Relative Humidity (noncondensing) Operating 10-90% 10-90% Nonoperating (38.7°C max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3048 m Nonoperating 30,000 ft 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Heat Dissipation Max STD PS 1410 BTU/hr 356 kg-cal/hr Typical STD PS idle 272 BTU/hr 68 kg-cal/hr Max EPA 87/89/85% @ 20/50/100% load PS 1255 BTU/hr 316 kg-cal/hr Typical EPA 87/89/85% @ 20/50/100% load PS idle 238 BTU/hr 59 kg-cal/hr Power Supply 115V 230V Operating Voltage Range (STD PS)1 90-264 VAC 90-264 VAC Operating Voltage Range (EPA 87/89/85% @ 20/50/100% load PS) 90-264 VAC 90-264 VAC Rated Voltage Range (STD PS) 100-240 VAC 100-240 VAC Rated Voltage Range (EPA 87/89/85% @ 20/50/100% load PS) 100-240 VAC 100-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz 42 Appendix A Specifications ENWW