HP 8/8 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
HP 8/8 Manual
View all HP 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 8/8 manual content summary:
- HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 1
53-1001767-01 ® 30 March 2010 Fabric OS Message Reference Supporting Fabric OS v6.4.0 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 2
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 3
Publication Summary of changes Date number Diagnostic and System Error Message Reference v4.2.0 53-0000515-08 Update software and hardware support March 2004 Fabric OS System Error Message 53-0000515-09 Updated for v4.4.0, Reference Manual First RASLog release August 2004 Fabric OS System - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 4
FCR, FICON, FICU, FLOD, FSPF, FSSM, FW, HAM, ,HAMK, HIL, IPS, ISNS, L2SYS, MFIC, PDM, PLAT, PORT, RCS, RPCD, RTWR, SEC, SNMP, SWCH, TRCE, TRCK, WEBD, ZONE. FSPF, FSS, FW, HAM, HSL, KAC, KSWD, LANCE, LFM, MS, NS, NSM, PMGR, PORT, PSWP, RKD, SEC, SPC, SPM, SS, SULB, SWCH, TAPE, UCST, UPTH, XTUN, ZONE - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 5
In this chapter lxix How this document is organized lxix Supported hardware and software lxix What's new in this document Overview of System Messages 1 System Error Message Logging 1 Event Auditing 2 System Logging Daemon (syslogd 3 System Console 3 Port Logs 3 Viewing and Configuring System - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 6
Responding to a System Message 11 Looking Up a System Message 12 Gathering Information About the Problem 12 Support 13 Panic Dump and Core Dump Files 13 Trace Dumps 13 supportSave Command 13 System Module Descriptions 13 Section I RASLog Messages Chapter 2 AG System Messages - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 7
Chapter 3 Chapter 4 AG-1026 32 AG-1027 32 AG-1028 32 AG-1029 32 AG-1030 33 AG-1031 33 AG-1032 33 AG-1033 33 AG-1034 34 AG-1035 34 AG-1036 34 AG-1037 34 AG-1038 35 AG-1039 35 AN System Messages AN-1001 37 AN-1002 37 AN-1003 37 AN-1004 38 AN-1005 38 AN-1010 38 AUTH System Messages - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 8
Chapter 5 AUTH-1016 42 AUTH-1017 43 AUTH-1018 43 AUTH-1020 43 AUTH-1022 44 AUTH-1023 44 AUTH-1025 45 AUTH-1026 45 AUTH-1027 45 AUTH-1028 46 AUTH-1029 46 AUTH-1030 46 AUTH-1031 47 AUTH-1032 47 AUTH-1033 47 AUTH-1034 48 AUTH-1035 48 AUTH-1036 48 AUTH-1037 49 AUTH-1038 49 AUTH-1039 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 9
Chapter 6 Chapter 7 ANV-1007 54 BKSW System Messages BKSW-1003 57 BL System Messages BL-1000 59 BL-1001 59 BL-1002 59 BL-1003 60 BL-1004 60 BL-1006 60 BL-1007 61 BL-1008 61 BL-1009 61 BL-1010 62 BL-1011 62 BL-1012 62 BL-1013 63 BL-1014 63 BL-1015 64 BL-1016 64 BL-1017 65 BL-1018 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 10
-1003 77 BM-1004 78 BM-1005 78 BM-1006 78 BM-1007 79 BM-1008 79 BM-1009 79 BM-1010 79 BM-1053 80 BM-1054 80 BM-1055 80 BM-1056 80 x Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 11
85 C2-1010 85 C2-1011 85 Chapter 12 CDR System Messages CDR-1001 87 CDR-1002 87 CDR-1003 87 CDR-1004 88 CDR-1005 88 CDR-1006 88 Chapter 13 CEE CONFIG System Messages CCFG-1001 89 CCFG-1002 89 CCFG-1003 89 CCFG-1004 89 CCFG-1005 90 CCFG-1006 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 12
-1010 99 CNM-1011 99 CNM-1012 99 CNM-1013 100 CNM-1014 100 CNM-1015 100 CNM-1016 100 CNM-1017 101 CNM-1018 101 CNM-1019 101 CNM-1020 101 CNM-1021 102 CNM-1022 102 CNM-1023 102 CNM-1024 102 CNM-1025 103 CNM-1026 103 CNM-1027 103 CNM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 13
Fabric OS Message Reference 53-1001767-01 CNM-1031 104 CNM-1032 104 CNM-1033 105 CNM-1034 105 CNM-1035 105 CNM-1036 105 CNM-1037 106 CNM-1038 106 CNM-1039 106 CNM-1040 106 CNM-1041 107 CNM-1042 107 CNM-1043 107 CNM-1044 107 CNM-1045 108 CNM-1046 108 CNM-1047 108 CNM-1048 108 CNM- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 14
CNM-3006 113 CNM-3007 114 CNM-3008 114 CNM-3009 114 CNM-3010 114 CNM-3011 115 CNM-3012 115 Chapter 17 CONF System Messages CONF-1000 117 CONF-1001 117 CONF-1020 117 CONF-1021 118 CONF-1022 118 CONF-1023 118 CONF-1024 118 CONF-1030 119 CONF-1031 119 CONF-1032 119 CONF-1040 119 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 15
CVLC-1011 126 CVLC-1012 126 CVLC-1013 126 CVLC-1014 126 CVLC-1015 127 CVLC-1016 127 CVLC-1017 127 CVLC-1018 127 CVLC-1019 128 CVLC-1020 128 CVLC-1021 128 CVLC-1022 129 CVLC-1023 129 CVLC-1024 129 CVLC-1025 129 CVLC-1026 130 CVLC-1027 130 CVLC-1028 130 CVLC-1029 130 CVLC-1030 131 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 16
CVLM-1011 135 CVLM-1012 135 CVLM-3001 136 CVLM-3002 136 CVLM-3003 136 CVLM-3004 136 CVLM-3005 137 CVLM-3006 137 CVLM-3007 137 CVLM-3008 137 CVLM-3009 138 CVLM-3010 138 CVLM-3011 138 CVLM-3012 138 CVLM-3013 139 CVLM-3014 139 CVLM-3015 139 CVLM-3016 140 CVLM-3017 140 CVLM-3018 140 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 17
DOT1-1006 146 DOT1-1007 146 DOT1-1008 146 DOT1-1009 147 DOT1-1010 147 Chapter 22 EM System Messages EM-1001 149 EM-1002 149 EM-1003 149 EM-1004 150 EM-1005 150 EM-1006 151 EM-1007 151 EM-1008 151 EM-1009 152 EM-1010 152 EM-1011 152 EM-1012 152 EM-1013 153 EM-1014 153 EM-1015 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 18
166 EM-2003 166 Chapter 23 ESS System Messages ESS-1001 167 ESS-1002 167 ESS-1003 167 ESS-1004 168 ESS-1005 168 Chapter 24 ESWCH System Messages ESW-1001 169 ESW-1002 169 ESW-1003 169 ESW-1004 170 ESW-1005 170 xviii Fabric OS Message Reference 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 19
ESW-1006 170 ESW-1007 170 ESW-1008 171 Chapter 25 EVMD System Messages EVMD-1001 173 Chapter 26 FABR System Messages FABR-1001 175 FABR-1002 175 FABR-1003 175 FABR-1004 176 FABR-1005 176 FABR-1006 176 FABR-1007 177 FABR-1008 177 FABR-1009 177 FABR-1010 178 FABR-1011 178 FABR-1012 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 20
FABR-1035 184 FABR-1036 184 FABR-1037 184 FABR-1038 185 FABR-1039 185 FABR-1040 185 FABR-1041 186 FABR-1043 186 FABR-1044 186 FABR-1045 186 FABR-1046 187 FABR-1047 187 FABR-1048 187 FABR-1049 188 Chapter 27 FABS System Messages FABS-1001 189 FABS-1002 189 FABS-1004 189 FABS-1005 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 21
Chapter 30 FCIP System Messages FCIP-1000 199 FCIP-1001 199 FCIP-1002 199 FCIP-1003 199 FCIP-1004 200 Chapter 31 FCOE System Messages FCOE-1001 201 FCOE-1002 201 FCOE-1003 201 FCOE-1004 201 FCOE-1005 202 FCOE-1006 202 FCOE-1007 202 FCOE-1008 202 FCOE-1009 203 FCOE-1010 203 FCOE- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 22
FCOE-1031 208 FCOE-1032 208 FCOE-1033 208 FCOE-1034 209 FCOE-1035 209 FCOE-1036 209 Chapter 32 FCPD System Messages FCPD-1001 211 FCPD-1002 211 FCPD-1003 211 Chapter 33 FCPH System Messages FCPH-1001 213 FCPH-1002 213 Chapter 34 FCR System Messages FCR-1001 215 FCR-1002 215 FCR- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 23
Fabric OS Message Reference 53-1001767-01 FCR-1024 221 FCR-1025 221 FCR-1026 221 FCR-1027 221 FCR-1028 222 FCR-1029 222 FCR-1030 223 FCR-1031 223 FCR-1032 223 FCR-1033 223 FCR-1034 224 FCR-1035 224 FCR-1036 224 FCR-1037 224 FCR-1038 225 FCR-1039 225 FCR-1040 225 FCR-1041 225 FCR- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 24
FCR-1068 231 FCR-1069 231 FCR-1070 232 FCR-1071 232 FCR-1072 232 FCR-1073 233 FCR-1074 233 FCR-1075 233 FCR-1076 234 FCR-1077 234 FCR-1078 234 FCR-1079 234 FCR-1080 235 FCR-1081 235 FCR-1082 235 FCR-1083 236 FCR-1084 236 FCR-1085 236 FCR-1086 236 FCR-1087 237 FCR-1088 237 FCR- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 25
Fabric OS Message Reference 53-1001767-01 FICN-1014 243 FICN-1015 243 FICN-1016 243 FICN-1017 243 FICN-1018 244 FICN-1019 244 FICN-1020 244 FICN-1021 245 FICN-1022 245 FICN-1023 245 FICN-1024 246 FICN-1025 246 FICN-1026 246 FICN-1027 246 FICN-1028 247 FICN-1029 247 FICN-1030 247 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 26
FICN-1051 253 FICN-1052 254 FICN-1053 254 FICN-1054 254 FICN-1055 254 FICN-1056 255 FICN-1057 255 FICN-1058 255 FICN-1059 256 FICN-1060 256 FICN-1061 256 FICN-1062 256 FICN-1063 257 FICN-1064 257 FICN-1065 257 FICN-1066 258 FICN-1067 258 FICN-1068 258 FICN-1069 258 FICN-1070 259 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 27
Chapter 36 FICU System Messages FICU-1001 265 FICU-1002 265 FICU-1003 265 FICU-1004 266 FICU-1005 266 FICU-1006 266 FICU-1007 267 FICU-1008 267 FICU-1009 267 FICU-1010 268 FICU-1011 268 FICU-1012 268 FICU-1013 268 FICU-1014 269 FICU-1015 269 FICU-1016 269 FICU-1017 269 FICU-1018 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 28
FSPF-1005 278 FSPF-1006 278 FSPF-1007 278 FSPF-1008 278 Chapter 40 FSS System Messages FSS-1001 281 FSS-1002 281 FSS-1003 281 FSS-1004 282 FSS-1005 282 FSS-1006 282 FSS-1007 282 FSS-1008 283 FSS-1009 283 FSS-1010 283 FSS-1011 284 Chapter 41 FSSM System Messages FSSM-1002 285 FSSM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 29
Fabric OS Message Reference 53-1001767-01 FW-1039 291 FW-1040 291 FW-1041 291 FW-1042 292 FW-1043 292 FW-1044 292 FW-1045 293 FW-1046 293 FW-1047 293 FW-1048 294 FW-1049 294 FW-1050 294 FW-1051 294 FW-1052 295 FW-1113 295 FW-1114 295 FW-1115 296 FW-1116 296 FW-1117 296 FW-1118 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 30
FW-1136 303 FW-1137 303 FW-1138 303 FW-1139 303 FW-1140 304 FW-1160 304 FW-1161 304 FW-1162 305 FW-1163 305 FW-1164 306 FW-1165 306 FW-1166 306 FW-1167 307 FW-1168 307 FW-1169 307 FW-1170 307 FW-1171 308 FW-1172 308 FW-1173 308 FW-1174 309 FW-1175 309 FW-1176 309 FW-1177 310 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 31
Fabric OS Message Reference 53-1001767-01 FW-1192 314 FW-1193 314 FW-1194 315 FW-1195 315 FW-1196 315 FW-1197 316 FW-1198 316 FW-1199 316 FW-1200 316 FW-1201 317 FW-1202 317 FW-1203 317 FW-1204 318 FW-1205 318 FW-1206 318 FW-1207 318 FW-1244 319 FW-1245 319 FW-1246 319 FW-1247 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 32
FW-1332 325 FW-1333 326 FW-1335 326 FW-1336 326 FW-1337 327 FW-1338 327 FW-1339 327 FW-1340 328 FW-1341 328 FW-1342 328 FW-1343 329 FW-1349 329 FW-1350 329 FW-1352 330 FW-1353 330 FW-1354 331 FW-1355 331 FW-1356 331 FW-1357 332 FW-1358 332 FW-1359 332 FW-1364 333 FW-1365 333 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 33
Fabric OS Message Reference 53-1001767-01 FW-1400 338 FW-1401 338 FW-1402 339 FW-1403 339 FW-1404 339 FW-1405 339 FW-1406 340 FW-1407 340 FW-1408 340 FW-1424 340 FW-1425 341 FW-1426 341 FW-1427 341 FW-1428 342 FW-1429 342 FW-1430 342 FW-1431 342 FW-1432 343 FW-1433 343 FW-1434 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 34
FW-1512 348 FW-1513 349 FW-1514 349 FW-1515 349 FW-1516 350 FW-1517 350 FW-1518 350 FW-1519 351 FW-1520 351 FW-1521 351 FW-1522 352 FW-1523 352 FW-1524 352 FW-1525 353 FW-1526 353 FW-1527 353 FW-1528 353 FW-1529 354 FW-1530 354 FW-1531 354 FW-1532 355 FW-1533 355 FW-1534 355 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 35
Chapter 43 HAM System Messages HAM-1001 361 HAM-1002 361 HAM-1004 361 HAM-1005 362 HAM-1006 362 HAM-1007 363 HAM-1008 363 HAM-1009 363 HAM-1010 364 HAM-1011 364 HAM-1012 364 HAM-1013 364 HAM-1014 365 Chapter 44 HAMK System Messages HAMK-1001 367 HAMK-1002 367 HAMK-1003 367 HAMK- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 36
HIL-1301 374 HIL-1302 374 HIL-1303 374 HIL-1304 374 HIL-1305 375 HIL-1306 375 HIL-1307 375 HIL-1308 375 HIL-1309 376 HIL-1310 376 HIL-1311 376 HIL-1401 376 HIL-1402 377 HIL-1403 377 HIL-1404 377 HIL-1501 377 HIL-1502 378 HIL-1503 378 HIL-1504 378 HIL-1505 379 HIL-1506 379 HIL- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 37
Chapter 47 HMON System Messages HMON-1001 385 Chapter 48 HSL System Messages HSL-1000 387 HSL-1001 387 HSL-1002 387 HSL-1003 387 HSL-1004 388 HSL-1004 388 HSL-1005 388 HSL-1006 388 HSL-1007 389 Chapter 49 HTTP System Messages HTTP-1001 391 HTTP-1002 391 HTTP-1003 391 Chapter 50 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 38
Chapter 53 IPAD System Messages IPAD-1000 401 IPAD-1001 401 Chapter 54 IPS System Messages IPS-1001 403 IPS-1002 403 IPS-1003 403 IPS-1004 403 IPS-1005 404 IPS-1006 404 Chapter 55 ISCS System Messages ISCS-1000 405 Chapter 56 ISNS System Messages ISNS-1001 407 ISNS-1002 407 ISNS- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 39
Chapter 58 KSWD System Messages KSWD-1001 413 KSWD-1002 413 Chapter 59 KTRC System Messages KTRC-1001 415 KTRC-1002 415 KTRC-1003 415 KTRC-1004 415 KTRC-1005 416 Chapter 60 L2SYS System Messages L2SS-1001 417 L2SS-1002 417 L2SS-1003 417 L2SS-1004 417 L2SS-1005 418 L2SS-1006 418 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 40
LOG-1003 426 Chapter 65 LSDB System Messages LSDB-1001 427 LSDB-1002 427 LSDB-1003 427 LSDB-1004 428 Chapter 66 MFIC System Messages MFIC-1001 429 MFIC-1002 429 MFIC-1003 429 Chapter 67 MPTH System Messages MPTH-1001 431 MPTH-1002 431 MPTH-1003 431 Chapter 68 MQ System Messages MQ - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 41
Chapter 70 MSTP System Messages MSTP-1001 441 MSTP-1002 441 MSTP-1003 441 MSTP-2001 441 MSTP-2002 442 MSTP-2003 442 MSTP-2004 442 MSTP-2005 442 MSTP-2006 443 Chapter 71 NBFS System Messages NBFS-1001 445 NBFS-1002 445 NBFS-1003 446 Chapter 72 NS System Messages NS-1001 447 NS-1002 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 42
NSM-1009 453 NSM-1010 453 NSM-1011 453 NSM-1012 453 NSM-1013 454 NSM-1014 454 NSM-1015 454 NSM-1016 454 NSM-1017 455 NSM-1018 455 NSM-1019 455 NSM-1020 455 NSM-1021 456 NSM-1022 456 Chapter 74 ONM System Messages ONMD-1000 457 ONMD-1001 457 ONMD-1002 457 ONMD-1003 457 ONMD-1004 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 43
-1004 469 PMGR-1005 470 PMGR-1006 470 PMGR-1007 470 PMGR-1008 470 PMGR-1009 471 PMGR-1010 471 PMGR-1011 471 Chapter 79 PORT System Messages PORT-1003 473 PORT-1004 473 PORT-1005 473 PORT-1006 474 PORT-1007 474 PORT-1008 474 Fabric OS Message Reference xliii 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 44
PORT-1009 474 PORT-1010 475 Chapter 80 PS System Messages PS-1000 477 PS-1001 477 PS-1002 477 PS-1003 477 PS-1004 478 PS-1005 478 PS-1006 478 PS- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 45
496 RPCD-1005 496 RPCD-1006 496 RPCD-1007 496 Chapter 87 RTWR System Messages RTWR-1001 497 RTWR-1002 497 RTWR-1003 498 Chapter 88 SAS System Messages SAS-1001 499 Chapter 89 SCN System Messages SCN-1001 501 Fabric OS Message Reference xlv 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 46
Chapter 90 SEC System Messages SEC-1001 503 SEC-1002 503 SEC-1003 504 SEC-1005 504 SEC-1006 504 SEC-1007 505 SEC-1008 505 SEC-1009 505 SEC-1010 505 SEC-1016 506 SEC-1022 506 SEC-1024 506 SEC-1025 507 SEC-1026 507 SEC-1028 507 SEC-1029 508 SEC-1030 508 SEC-1031 508 SEC-1032 508 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 47
Fabric OS Message Reference 53-1001767-01 SEC-1053 514 SEC-1054 514 SEC-1055 514 SEC-1056 515 SEC-1057 515 SEC-1059 515 SEC-1062 515 SEC-1063 516 SEC-1064 516 SEC-1065 516 SEC-1069 516 SEC-1071 517 SEC-1072 517 SEC-1073 517 SEC-1074 517 SEC-1075 518 SEC-1076 518 SEC-1077 518 SEC- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 48
SEC-1097 524 SEC-1098 524 SEC-1099 525 SEC-1100 525 SEC-1101 525 SEC-1102 525 SEC-1104 526 SEC-1105 526 SEC-1106 526 SEC-1107 527 SEC-1108 527 SEC-1110 527 SEC-1111 527 SEC-1112 528 SEC-1113 528 SEC-1114 528 SEC-1115 529 SEC-1116 529 SEC-1117 529 SEC-1118 529 SEC-1119 530 SEC- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 49
Fabric OS Message Reference 53-1001767-01 SEC-1155 535 SEC-1156 535 SEC-1157 535 SEC-1158 536 SEC-1159 536 SEC-1160 536 SEC-1163 536 SEC-1164 537 SEC-1165 537 SEC-1166 537 SEC-1167 538 SEC-1168 538 SEC-1170 538 SEC-1171 539 SEC-1172 539 SEC-1173 539 SEC-1174 539 SEC-1175 540 SEC- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 50
SEC-1198 545 SEC-1199 546 SEC-1200 546 SEC-1201 546 SEC-1202 547 SEC-1203 547 SEC-1250 547 SEC-1251 547 SEC-1253 548 SEC-1300 548 SEC-1301 548 SEC-1302 549 SEC-1303 549 SEC-1304 549 SEC-1305 549 SEC-1306 550 SEC-1307 550 SEC-1308 550 SEC-1309 551 SEC-1310 551 SEC-1311 551 SEC- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 51
SEC-1328 556 SEC-1329 556 SEC-1330 556 SEC-1331 557 SEC-1332 557 SEC-1333 557 SEC-3005 557 SEC-3035 558 SEC-3036 558 SEC-3037 558 SEC-3038 559 SEC-3039 559 SEC-3050 559 SEC-3051 559 SEC-3061 560 SEC-3062 560 SEC-3063 560 SEC-3064 560 SEC-3065 561 SEC-3066 561 SEC-4001 561 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 52
SNMP-1005 568 SNMP-1006 568 SNMP-1007 568 SNMP-1008 569 Chapter 93 SPC System Messages SPC-1001 571 SPC-1002 571 SPC-1003 571 SPC-2001 572 SPC-2002 572 SPC-2003 572 SPC-2004 572 SPC-2005 573 SPC-2006 573 SPC-2007 573 SPC-2008 573 SPC-2009 574 SPC-2010 574 SPC-2011 574 SPC-2012 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 53
Chapter 94 SPM System Messages SPM-1001 581 SPM-1002 581 SPM-1003 581 SPM-1004 581 SPM-1005 582 SPM-1006 582 SPM-1007 582 SPM-1008 582 SPM-1009 583 SPM-1010 583 SPM-1011 583 SPM-1012 583 SPM-1013 584 SPM-1014 584 SPM-1015 584 SPM-3001 584 SPM-3002 585 SPM-3003 585 SPM-3004 585 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 54
SPM-3022 590 SPM-3023 590 SPM-3024 590 SPM-3025 590 SPM-3026 591 SPM-3027 591 SPM-3028 591 SPM-3029 591 Chapter 95 SS System Messages SS-1000 593 SS-1001 593 SS-1002 593 SS-1003 594 SS-1004 594 SS-1005 594 SS-1006 594 SS-1007 595 SS-1008 595 Chapter 96 SSM System Messages SSMD- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 55
SSMD-1211 601 SSMD-1212 601 SSMD-1213 601 SSMD-1214 602 SSMD-1215 602 SSMD-1216 602 SSMD-1217 603 SSMD-1300 603 SSMD-1301 603 SSMD-1302 603 SSMD-1303 604 SSMD-1304 604 SSMD-1305 604 SSMD-1306 604 SSMD-1307 605 SSMD-1308 605 SSMD-1309 605 SSMD-1310 605 SSMD-1311 606 SSMD-1312 606 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 56
SULB-1020 616 SULB-1021 616 SULB-1022 617 SULB-1023 617 SULB-1024 617 SULB-1025 618 SULB-1026 618 SULB-1030 618 SULB-1031 618 SULB-1032 619 SULB-1033 619 SULB-1034 619 SULB-1035 619 SULB-1036 620 SULB-1037 620 SULB-1038 620 SULB-1039 621 SULB-1040 621 Chapter 98 SWCH System - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 57
SYSM System Messages SYSM-1001 631 SYSM-1002 631 SYSM-1003 631 SYSM-1004 632 SYSM-1005 632 SYSM-1006 632 SYSM-1007 632 Chapter 101 TAPE System Messages TAPE-1001 633 Chapter 102 TRCE System Messages TRCE-1001 635 TRCE-1002 635 TRCE-1003 635 TRCE-1004 636 TRCE-1005 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 58
Chapter 103 TRCK System Messages TRCK-1001 639 TRCK-1002 639 TRCK-1003 639 TRCK-1004 639 TRCK-1005 640 TRCK-1006 640 Chapter 104 TS System Messages TS-1001 641 TS-1002 641 TS-1006 642 TS-1007 642 TS-1008 642 Chapter 105 UCST System Messages UCST-1003 643 UCST-1007 643 UCST-1020 643 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 59
XTUN-1001 649 XTUN-1002 649 XTUN-1003 649 XTUN-1004 650 XTUN-1998 650 XTUN-1999 650 XTUN-2000 650 XTUN-2001 651 XTUN-2002 651 XTUN-2003 651 XTUN-2004 651 XTUN-2005 652 Chapter 109 ZEUS System Messages ZEUS-1001 653 Chapter 110 ZOLB System Messages ZOLB-1001 655 Chapter 111 ZONE System - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 60
ZONE-1026 662 ZONE-1027 663 ZONE-1028 663 ZONE-1029 663 ZONE-1030 664 ZONE-1031 664 ZONE-1032 664 ZONE-1033 664 ZONE-1034 665 ZONE-1035 665 ZONE-1036 665 ZONE-1037 666 ZONE-1038 666 ZONE-1039 666 ZONE-1040 666 ZONE-1041 667 ZONE-1042 667 ZONE-1043 667 ZONE-1044 667 ZONE-1045 668 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 61
AG-1034 675 AG-1035 675 AG-1036 675 AG-1037 676 Chapter 113 AUDIT AN System Messages AN-1003 677 AN-1004 677 AN-1005 677 AN-1006 678 AN-1010 678 Chapter 114 AUDIT AUTH System Messages AUTH-1045 679 AUTH-1046 679 AUTH-1047 679 AUTH-3001 680 AUTH-3002 680 AUTH-3003 680 AUTH-3004 680 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 62
CNM-3009 687 CNM-3010 687 CNM-3011 687 CNM-3012 688 Chapter 117 AUDIT CONF System Messages CONF-1000 689 CONF-1001 689 CONF-1020 689 CONF-1022 690 CONF-1042 690 CONF-1043 690 Chapter 118 AUDIT CVLM System Messages CVLM-3001 691 CVLM-3002 691 CVLM-3003 691 CVLM-3004 692 CVLM-3005 692 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 63
HTTP System Messages HTTP-1002 705 HTTP-1003 705 Chapter 123 AUDIT IPAD System Messages IPAD-1002 707 Chapter 124 AUDIT PORT System Messages PORT-1006 709 PORT-1007 709 PORT-1008 709 PORT-1009 709 Chapter 125 AUDIT SEC System Messages SEC-1113 711 SEC-1114 711 SEC-3001 711 SEC-3002 712 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 64
SEC-3004 712 SEC-3005 713 SEC-3006 713 SEC-3007 713 SEC-3008 714 SEC-3009 714 SEC-3010 714 SEC-3011 714 SEC-3012 715 SEC-3013 715 SEC-3014 715 SEC-3015 716 SEC-3016 716 SEC-3017 716 SEC-3018 717 SEC-3019 717 SEC-3020 717 SEC-3021 717 SEC-3022 718 SEC-3023 718 SEC-3024 718 SEC- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 65
SEC-3045 723 SEC-3046 723 SEC-3047 724 SEC-3048 724 SEC-3049 724 SEC-3050 724 SEC-3051 725 SEC-3061 725 SEC-3062 725 SEC-3063 725 SEC-3064 726 SEC-3065 726 SEC-3066 726 SEC-4001 726 Chapter 126 AUDIT SNMP System Messages SNMP-1004 729 SNMP-1005 729 SNMP-1006 729 Chapter 127 AUDIT - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 66
SPM-3017 735 SPM-3018 735 SPM-3019 735 SPM-3020 736 SPM-3021 736 SPM-3022 736 SPM-3023 736 SPM-3024 737 SPM-3025 737 SPM-3026 737 SPM-3027 737 SPM-3028 738 SPM-3029 738 Chapter 128 AUDIT SULB System Messages SULB-1001 739 SULB-1002 739 SULB-1003 739 SULB-1004 740 SULB-1009 740 SULB - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 67
SULB-1040 751 Chapter 129 AUDIT SWCH System Messages SWCH-1012 753 SWCH-1013 753 SWCH-1014 753 Chapter 130 AUDIT UCST System Messages UCST-1021 755 UCST-1022 755 UCST-1023 755 UCST-1024 756 UCST-1025 756 UCST-1026 756 UCST-1027 756 Chapter 131 AUDIT ZONE System Messages ZONE-3001 759 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 68
ZONE-3022 765 ZONE-3023 765 ZONE-3024 765 ZONE-3025 765 lxviii Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 69
procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for 6.4.0, documenting all - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 70
• Brocade 5100 • Brocade 5300 • Brocade 5410 • Brocade 5424 • Brocade 5450 • Brocade 5460 • Brocade 5470 • Brocade 5480 • Brocade 7500 • Brocade 7500E • Brocade 7600 • Brocade 7800 • Brocade 8000 • Brocade 48000 • Brocade Encryption Switch • Brocade DCX Backbone • Brocade DCX-4S Backbone • Brocade - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 71
- "CNM System Messages" - "AUDIT CNM System Messages" - "CONF System Messages" - "AUDIT CONF System Messages" - "CVLC System Messages" - "CVLM System Messages" - "AUDIT CVLM System Messages" - "FABR System Messages" - "FICU System Messages" - "AUDIT FICU System Messages" - "FW System Messages" - " - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 72
command names Identifies the names of user-manipulated GUI elements Identifies keywords and in the narrative portions of this guide are presented in mixed lettercase: for warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 73
damage to hardware, firmware, software, or Brocade and Fibre Channel, see the Brocade Glossary. For definitions of SAN brocade.com and register at no cost for a user ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website at: http://www.brocade - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 74
name and software version, if applicable • Error numbers and messages received • supportSave command output • Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 75
on the bottom of the port side of the switch • Brocade 7600-On the bottom of the chassis • Brocade 48000-Inside the chassis next to the power supply bays • Brocade DCX-On the bottom right on the port side of the chassis • Brocade DCX-4S-On the bottom right on the port side of the chassis, directly - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 76
lxxvi Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 77
13 Overview of System Messages This guide supports Fabric OS v6.4.0 and documents system messages that can help you diagnose and fix problems with a switch or fabric. The messages are organized first by event type, reliability, availability, and serviceability log (RASLog) or AUDIT, and then - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 78
Event auditing is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Fabric OS versions earlier than v5.2.0 generated - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 79
other operating system that supports the standard syslogd functionality. Configuring for syslogd involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the facility level. For the Brocade DCX, 24000 and 48000, each CP has a unique error log, depending on which - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 80
Guide for information on interpreting results of the portLogDump command. Port log functionality is completely separate from the system message log. Port logs are typically used to troubleshoot Configuring Event Auditing The procedures are valid for the Brocade DCX, 200E, 3016, 3250, 3850, 3900, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 81
Logs Command Description agtCfgDefault Resets the SNMP recipients to default values. agtCfgSet Modifies port error summary. portLogClear Clears the port log. If the port log is disabled, this command enables it. portLogDisable Disables the port log facility. portLogDump Displays the port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 82
error display commands. This output is used by your switch service provider to diagnose and correct problems with the switch. The output from this command is very long. syslogDIpAdd Adds an IP is a reference to the blade within the switch platform, e.g.,Brocade 7500 and AP7600 contain FR4-18i and - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 83
and Configuring System Message Logs 1 2004/07/28-17:04:51, [EM-1055], 3,, WARNING, switch, Media 27: Port media incompatible. Reason: Configured port speed. 2004/07/28-17:04:54, [FABR-1001], 4,, WARNING, switch, port 4, ELP rejected by the other switch 2004/07/28-17:05:06, [FW-1050], 5,, WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 84
Number>, ,,, The following example shows a sample message from the error log: 2009/02/10-14:18:04, [SS-1000], 88, SLOT 6 | FFDC | CHASSIS, INFO, ESNSVT_DCX, supportSave has uploaded support information to the host with IP address 168.159 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 85
manual. Note that not all message numbers are used; there can be gaps in the numeric message sequence. Sequence Number The error reset to 1 using the errClear command. The sequence number is persistent across power cycles and switch was generated by the default switch instance. CHASSIS is the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 86
Severity Level Event Class User ID Role IP Address Interface Application Name Admin Domain Identifies the message as an Audit message. The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized timestamp format base on the "LOCAL - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 87
operating in redundant mode unless the failed power supply is replaced or fixed. Info-level messages report the current non-error status of the system components: for example, detecting online and offline status of a fabric port. Responding to a System Message This section provides procedures on - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 88
the error • Message text • Probable cause • Recommended action • Message severity Gathering Information About the Problem Common steps and questions to ask yourself when troubleshooting a system message are as follows: 1. What is the current Fabric OS level? 2. What is the switch hardware version - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 89
help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access and/or save the information for support personnel. to slot 0 is a reference to the blade within the switch platform, for example: Brocade DCC contains FC8-48, FC9-32, and FC8-16 blades. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 90
hardware platforms. Fibre Channel over IP port configuration message over Spike and Striker Blade. Blade management error messages are a result of autoleveling firmware upgrades performed by the control processor (CP). Condor2 error messages indicate problems with the Condor2 ASIC driver module - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 91
lists to all switches in the fabric. Fabric OS system driver module. Firmware blade compatibility errors with control processor (CP). Fibre Channel over IP port configuration messages over Sprint and Marathon Blade. Fibre Channel miscellaneous messages relate to problems with the physical layer - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 92
the identity of the neighbor switch, and to exchange FSPF parameters and capabilities. Health monitor. HSL error messages indicate problems with the Hardware Subsystem Layer of the Fabric OS. HTTP error messages. This raslog generates messages related to port restart failure. IBPD stands for - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 93
Monitor (emd) • EVM daemon (evmd) • Exchange Service Support daemon (essd) • FA-API rpc daemon (rpcd) error messages indicate problems with the LANCE module of the Fabric OS. LFM error messages indicate problems with the logical fabric manager module that is responsible for making a logical switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 94
message queue. The Management Service enables the user to obtain information about problems. A group of messages relating to logical switch creation, deletion and configuration. PORT error messages refer to the front-end user ports on the switch. Front-end user ports are directly accessible by users - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 95
SSM error messages indicate problems with the System Services Module of the Fabric OS. The software upgrade library provides the firmwareDownload command capability, which enables firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to all 4.x switches. These - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 96
feature, refer to the Fabric OS Command Reference or the Fabric OS Administrator's Guide. Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the clock time on the principal switch. UCST is a part of the fabric shortest path first (FSPF) protocol that - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 97
RASLog Messages Section I This section provides the RASLog messages, including: •AG System Messages 25 •AN System Messages 37 •AUTH System Messages 39 •ANV System Messages 53 •BKSW System Messages 57 •BL System Messages 59 •BLL System Messages 73 •BLS System Messages 75 •BM System Messages - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 98
387 •HTTP System Messages 391 •IBD System Messages 393 •IBPD System Messages 395 •ICPD System Messages 397 •IPAD System Messages 401 •IPS System Messages 403 •ISCS System Messages 405 •ISNS System Messages 407 •KAC System Messages 411 •KSWD System Messages 413 •KTRC System Messages - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 99
•PDM System Messages 459 •PDTR System Messages 465 •PLAT System Messages 467 •PMGR System Messages 469 •PORT System Messages 473 •PS System Messages 477 •PSWP System Messages 481 •RAS System Messages 483 •RCS System Messages 487 •RMOND System Messages 493 •RKD System - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 100
24 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 101
. • Some blades and ports in a switch may not support NPIV. NPIV functionality can not be enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway Administrator Guide, Appendix B, for specific AG-compatibility requirements. • On non-Brocade switches, refer to the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 102
ERROR, , Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port. Recommended Action Check the configuration of the fabric switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 103
switch port. Action Severity WARNING AG-1008 Message , [AG-1008], ,, WARNING, , Invalid port login (PLOGI) response from the fabric on the N_Port . Probable Cause Indicates the fabric switch and contact your switch service provider. Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 104
system-name>, Sending FDISC failed on N_Port . Probable Cause Indicates there was a failure sending discover F_Port service parameter request from the Access Gateway to the fabric switch. Recommended Action Check the configuration of the fabric switch connected to the Access Gateway. If the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 105
up automatic FTP transfers; then run the supportsave command and contact your switch service provider. Severity WARNING AG-1016 Message , [AG-1016], < [AG-1018], ,, ERROR, , Host port should not be connected to port , which is configured as N_Port. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 106
an F_port. Severity ERROR AG-1019 Message , [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported. Recommended Check whether - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 107
the same. Recommended Action Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is assigned to all ports in the system and run the porttrunkarea --enable command to reconfigure the Trunk Area. Severity ERROR Fabric OS Message Reference 31 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 108
command and contact your switch service provider. Severity WARNING AG-1027 Message , [AG-1027], ,, WARNING, , Unable to handle this login request on port because NPIV capability is not enabled on this port. Probable Cause Indicates NPIV - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 109
action is required. Action Severity WARNING AG-1031 Message , [AG-1031], ,, WARNING, , Loop Detected for device with Port WWN connected to port Probable Cause Indicates that the routing Loop is detected for the device connected to the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 110
], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is required - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 111
connected fabric switch port displays 'Persistently disabled: Area has been acquired', then check the cabling on the AG. All trunked ports in a single trunk should belong to the same ASIC Port Group. Severity INFO AG-1038 Message , [AG-1038], ,, ERROR, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 112
2 AG-1039 36 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 113
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR is slow in responding to frames going out of this port. This latency may be inherent in the device or due to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 114
WARNING, , Severe latency bottleneck detected at Slot port . Probable Cause Indicates a credit loss. Recommended Contact your vendor's customer support for assistance. Action Severity WARNING 38 Fabric OS Message Reference 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 115
. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1003 Message , [AUTH-1003], ,, INFO, , type has been successfully set to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 116
run the supportSave command and contact your switch service provider. Severity WARNING AUTH-1007 Message Probable Cause , [AUTH-1007], ,, ERROR, , The proposed authentication protocols are not supported: port . Indicates that the proposed - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 117
and contact your switch service provider. Severity ERROR AUTH-1011 Message , [AUTH-1011], ,, WARNING, , Failed to register for failover operation: switch error . Probable Cause Indicates an internal problem with the Secure - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 118
supportSave command and contact your switch service provider. Severity WARNING AUTH-1014 Message , [AUTH-1014], , FFDC, ERROR, , Invalid port value to : port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 119
the supportSave command and contact your switch service provider. Severity ERROR AUTH-1018 Message , [AUTH-1018], ,, ERROR, , Invalid value to check protocol type: port . Probable Cause Indicates an internal problem with the Secure Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 120
run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1023 Message , [AUTH-1023], ,, ERROR, , Failed to during : port . Probable Cause Indicates an authentication - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 121
; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1026 Message , [AUTH-1026], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 122
phase failed. Recommended Action Usually this problem is transient. The authentication might switch service provider. Severity ERROR AUTH-1030 Message Probable Cause , [AUTH-1030], ,, ERROR, , Invalid message code for message: port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 123
attacks. Recommended Action Usually this problem is transient. The authentication might switch service provider. Severity ERROR AUTH-1033 Message Probable Cause , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 124
; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port . Probable Cause Indicates that the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 125
run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1039 Message , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port disabled. Probable Cause Indicates that the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 126
transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1042 Message Probable Cause Recommended Action , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 127
and the cable. Then try to enable the port using the portEnable command. Action Severity ERROR AUTH-1045 Message , [AUTH-1045], ,, ERROR, , Certificate not present in this switch in port . Probable Cause Indicates that - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 128
Severity INFO AUTH-1047 Message , [AUTH-1047], ,, ERROR, , has failed. Probable Cause Indicates that the the supportSave command and contact your switch service provider. Severity ERROR 52 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 129
faulty. Replace the SFPs or the cable if necessary. Severity ERROR ANV-1002 Message , [ANV-1002], ,Ffdc, ERROR, , Port chip faulted due to internal error. Probable Cause Indicates an internal error. All the ports on the blade or switch will - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 130
maintenance window. If the problem persists, replace the CP blade. Action Severity ERROR ANV-1006 Message , [ANV-1006], ,, CRITICAL, , ,: HW ASIC Chip fault. Type = 0x, Error = . Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 131
Severity CRITICAL ANV-1007 5 Fabric OS Message Reference 55 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 132
5 ANV-1007 56 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 133
if any core files were created. If a core file is found, run supportFtp to send all the core files to a secure server location. Copy the error message and any core file information, and contact your switch service provider. Severity WARNING Fabric OS Message Reference 57 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 134
6 BKSW-1003 58 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 135
Manual for more information on this command. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Additional blade fault messages precede and follow this error, providing more information. See other error messages for recommended action. If the message persists, replace - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 136
does not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 137
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace circuit (ASIC) chips. Recommended Action Make - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 138
the switch. If the message persists, replace the blade or the (nonbladed) switch. Severity CRITICAL BL-1012 Message , [BL-1012], ,, ERROR, , bport port int. is disabled. status=0x Port will be re-enabled in - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 139
. If the message persists, replace the blade or the (nonbladed) switch. Severity ERROR BL-1013 Message , [BL-1013], ,, ERROR, , bport port is faulted. status=0x Port will be re-enabled in 1 minute. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 140
Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500, AP7600, and 5000, replace the switch. Severity ERROR BL-1016 Message , [BL-1016], , FFDC, CRITICAL, , Blade port in slot failed to enable. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 141
problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace completed initializing the ports. Recommended No - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 142
not have hardware problems. To run this command root access is required. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the switch. Severity CRITICAL BL - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 143
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all GbE or Fibre Channel over IP (FCIP) or Virtualization data elements or FC Fastwrite ports were reset. Recommended No action is required - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 144
(POST) is enabled. If the problem persists, replace the switch. Severity CRITICAL switch. If the message persists, replace the switch. Severity CRITICAL BL-1029 Message , [BL-1029], ,, INFO, , All ports on the switch will be reset as part of the firmware - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 145
/FC Fastwrite ports on the switch will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all the GbE or Fibre Channel over IP - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 146
the user ports after disabling the ports. Recommended Action Restart or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If the message persists, replace - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 147
incompatible with the software version. Recommended Power cycle the blade. If the message persists, replace the blade. Action Severity CRITICAL BL-1041 Message , [BL-1041], ,, CRITICAL, , Dynamic area mode is enabled on default switch, Faulting the blade - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 148
of blade that has the SFP> error on SFP in Slot /Port (). Try reseating or replacing it. Probable Cause Indicates the checksum - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 149
port as faulty (reason: ) Probable Cause Indicates a blade regulation problem was reported on problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 150
8 BLL-1000 Severity CRITICAL 74 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 151
Message , [BLS-1000], ,, ERROR, , of GE failed. Please retry the command. Data: a FIPS failure has occurred and requires faulting the blade or switch. Recommended Retry the command. Action Severity CRITICAL BLS-1002 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 152
that the FOS version on the remote end of the tunnel does not support the Tape Read Pipelining feature. Recommended No action is required. Action Severity INFO BLS-1005 Message , [BLS-1005], ,, ERROR, , S,P - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 153
on the application processor (AP) blade. You can modify the firmware version on the CP blade by using the firmwareDownload command. Refer to the release notes to determine whether a non-disruptive firmware download is supported between the revisions. Because the AP and CP blades cannot communicate - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 154
firmware due to a firmware upgrade. • The blade was just inserted and had a different version of the firmware loaded. Recommended No action is required. The blade will automatically download the updated firmware blade. On the Brocade Action 7500 or 7600, switch off and switch on all primary power - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 155
blade. On the Brocade Action 7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit. Severity WARNING BM-1010 Message , [BM-1010], ,, INFO, , Resetting port configuration and linkcost for all ports for blade in slot - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 156
version of the firmware loaded. Recommended No action is required. The blade will automatically download the updated firmware. Action Severity INFO BM-1055 Message , [BM-1055], ,, WARNING, , Firmwaredownload timed-out for AP. Faulting switch. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 157
under a different mode. Recommended Configure the switch to persistently enable all ports. Action Severity INFO BM-1058 Message , [BM-1058], ,, WARNING, , Download of AP firmware failed for the switch. Reissue firmwaredownload to recover. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 158
10 BM-1058 82 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 159
is not faulty. Replace SFPs or cable if necessary. Severity ERROR C2-1002 Message , [C2-1002], ,, ERROR, , Port chip faulted due to an internal error. Probable Cause Internal error. All the ports on the blade or switch will be disrupted - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 160
>, ,: Internal link errors reported, no hardware monitoring of internal hardware reported errors. There is no action required by the user at this time. If any port number>(): best effort QOS will be turned off at next port state change as it is not supported - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 161
the faulted blade. If the problem persists, Action replace the blade. Severity CRITICAL C2-1011 Message Message , [C2-1011], ,, WARNING, , S , P : Primitive received with Encoding errors, do AL_RESET. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 162
11 C2-1011 86 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 163
Channel cable is faulty. Replace the SFPs or cable, if necessary. Severity ERROR CDR-1002 Message , [CDR-1002], , FFDC, ERROR, , Port chip faulted due to internal error. Probable Cause Indicates an internal error. Recommended Action For - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 164
system at the next maintenance window. If the problem Action persists, replace the blade. Severity ERROR CDR-1005 Message , [CDR-1005], ,, WARNING, , , : at next port state change, best effort QOS will be turned - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 165
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR , , System is ready to accept CEE user commands. Probable Cause Indicates that the Converged Enhanced Ethernet - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 166
startup configuration from any backup Action retrieved on the server. Severity ERROR CCFG-1005 Message , [CCFG-1005], ,, Cause Indicates that the startup configuration has been updated by the user. Recommended No action is required. Action Severity INFO CCFG-1006 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 167
initialization has failed. Recommended No action is required. Action Severity ERROR CCFG-1009 Message , [CCFG-1009], ,, WARNING CCFG-1012 Message , [CCFG-1012], ,, ERROR, , Blade in slot failed to reach ONLINE - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 168
after system ready event. Recommended Run the slotpoweroff command followed by the slotpoweron command on the slot to retry bringing Action the slot online. Severity ERROR 92 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 169
CP does not support the Advanced Performance Tuning module when the fibre connectivity (FICON) Management Server is enabled. Recommended Action Run the firmwareDownload command to upgrade the firmware on the standby CP. You can also disable FMS on the active CP. Severity ERROR Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 170
14 CER-1001 94 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 171
sequence-number>,, ERROR, , Slot ENABLED but Not Ready during recovery, disabling slot = rval = . Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery. Recommended On a Brocade 24000 or 48000 switch, run - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 172
24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR 96 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 173
of a module within the CNM has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CNM-1003 Message , [CNM-1003], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 174
16 CNM-1005 Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [ - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 175
16 CNM-1009 Recommended No action is required. Action Severity INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode. Recommended No action is required. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 176
16 CNM-1013 Recommended No action is required. Action Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, ,Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the encryption group (EG) is split. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 177
Message , [CNM-1020], ,, INFO, , Node Admission Control failed, due to mismatch in certificates, rejecting node []. Fabric OS Message Reference 101 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 178
16 CNM-1021 Probable Cause Indicates that the Node Admission Control has failed. Recommended No action is required. Action Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 179
-number>,, INFO, , Received HBT Message with version mismatch, Received Hdr version Expected Hdr version Node . Probable Cause Indicates that a version mismatch has occurred. Recommended Upgrade the firmware or delete the Node from the encryption group (EG - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 180
16 CNM-1029 Probable Cause Indicates that the certificate file for the node already exists. Recommended No action is required. Action Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the cert sent by GL. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 181
16 CNM-1033 Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended No action is required. Action Severity WARNING CNM-1033 Message , [CNM-1033], ,, WARNING, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 182
16 CNM-1037 Probable Cause Indicates an event is being posted to indicate that the cluster is in a converged state. Recommended No action is required. Action Severity INFO CNM-1037 Message , [CNM-1037], ,, INFO, , Split-Brain Arbitration lost!, minority - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 183
name>, Updating persistent Cluster DB, please avoid powering off the switch. Probable Cause Indicates the system is updating the persistent database ,, ERROR, , Received HBT from undefined node IpAddress [], WWN []. Possible configuration error. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 184
16 CNM-1045 Recommended No action is required. Action Severity ERROR CNM-1045 Message , [CNM-1045], ,, ERROR, , Member node is having dual IP stack.Registering member node with dual IP in an EG with only IPV6 is not allowed. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 185
node . Probable Cause Indicates mode mismatch between the switches like the Access Gateway mode mismatch. Recommended No action is required. Action Severity ERROR CNM-1051 Message , [CNM-1051], ,, ERROR, , Join Rejected by GL Node due to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 186
another encryption group (EG). Recommended No action is required. Action Severity ERROR CNM-1054 Message , [CNM-1054], ,, INFO, , Encryption Group database state with node ip , wwn . Probable Cause Indicates the status of the cluster - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 187
Severity INFO CNM-1057 Message , [CNM-1057], ,, INFO, , Posting event CNM_EVT_ONLINE Slot , Wwn , IP , flags . Probable Cause Indicates that the encryption engine (EE) is online in the encryption group (EG). Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 188
. Action Severity INFO CNM-1061 Message , [CNM-1061], ,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed. Recommended No action is required. Action Severity INFO CNM-1062 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 189
16 CNM-3003 Recommended No action is required. Action Severity INFO CNM-3003 Message , [CNM-3003],,, INFO, , Event: cryptocfg Status: success, Info: Membernode \\ added to encryption group. Probable Cause Indicates a member node was added - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 190
16 CNM-3007 Recommended No action is required. Action Severity INFO CNM-3007 Message , [CNM-3007],,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat timeout set to . Probable Cause Indicates that the heartbeat timeout value was set. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 191
16 CNM-3011 Recommended No action is required. Action Severity INFO CNM-3011 Message , [CNM-3011], ,, INFO, , Event: cryptocfg Status: success, Info: Encryption group synchronized. Probable Cause Indicates an encryption group was synchronized. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 192
16 CNM-3012 116 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 193
of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description . There are many possible causes. Recommended Check the error log, correct the error and rerun the configdownload command. Action Severity INFO Fabric - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 194
causes. Recommended Check the error log, correct the error and rerun the configupload command. Action Severity INFO CONF-1022 Message , [CONF-1022], ,, WARNING, , Downloading configuration without disabling the switch was unsuccessful. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 195
INFO CONF-1040 Message , [CONF-1040], ,, INFO, , configDefault failed. Probable Cause Indicates a configDefault error has occurred. Recommended Correct the error and try again. Action Severity INFO Fabric OS Message Reference 119 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 196
Message , [CONF-1041], ,, INFO, , configRemove failed. Probable Cause Indicates a configRemove error has occurred. Recommended Correct the error and try again. Action Severity INFO CONF-1042 Message , [CONF-1042], ,, INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 197
Chapter CTAP System Messages 18 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 198
18 CTAP-1001 122 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 199
, Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed. The operation has been started, completed or cancelled. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 200
. Action Severity WARNING CVLC-1007 Message Probable Cause , [CVLC-1007], ,, ERROR, , Removal of encryption LUN is not allowed when decrypt of existing data is enabled.\nContainer: , Initiator: , LUN ID: - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 201
is required for tape container: . Probable Cause Indicates that the tape container is configured with non-Brocade mode but there is no valid license. Recommended Obtain license for non-Brocade mode. Action Severity ERROR Fabric OS Message Reference 125 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 202
to retrieve the key record base on the key ID found in the metadata. Recommended No action is required. Action Severity ERROR CVLC-1014 Message Probable Cause , [CVLC-1014], ,, ERROR, , Missing Key ID from user input.\nContainer: - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 203
event>.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates a warning or an error event. Recommended No action is required. Action Severity INFO CVLC-1018 Message , [CVLC-1018], ,, INFO, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 204
on the LUN that is clear text. Recommended Use cryptocfg command to confirm the configuration. Action Severity ERROR CVLC-1021 Message , [CVLC-1021], ,, INFO, , User provided key ID is ignored while metadata - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 205
Message , [CVLC-1022], ,, INFO, , User provided key ID is ignored while data state INFO CVLC-1025 Message , [CVLC-1025], ,, ERROR, , Secondary Metadata exists for encrypted LUN not configured - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 206
metadata was corrupted. Recommended No action is required. Action Severity ERROR CVLC-1028 Message , [CVLC-1028], ,, ID>. Probable Cause Indicates a warning event. Recommended Perform a manual rekey on this LUN. Action Severity WARNING CVLC-1029 Message Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 207
. Probable Cause Indicates the manual rekey was completed on primary LUN. Recommended Action 1. Make the target ports of the mirror LUN offline to hosts Add it to its container with -newLUN option. 3. Using host based migration application, copy data from old to new primary LUN. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 208
reason>. Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation failed. Recommended No action is required. Action Severity INFO CVLC-1035 Message , [CVLC-1035], ,, ERROR, , A decommissioned LUN has been added back as - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 209
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR -name>, Crypto device configuration between local switch and peer is out of sync. New - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 210
the Fabric OS Command Reference Manual for more information on this command. Severity WARNING CVLM-1005 Message , [CVLM-1005], ,, INFO, , Crypto service is on the switch. Probable Cause Indicates that Crypto service is enabled or disabled on the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 211
20 CVLM-1009 Recommended Check the ISL port connected to the fabric. Action Severity WARNING CVLM-1009 Message < CVLM-1010 Message , [CVLM-1010], ,, WARNING, , The IP address of EE IO link is not configured. Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 212
20 CVLM-3001 Recommended No action is required. Action Severity INFO CVLM-3001 Message , [CVLM-3001], ,, INFO, , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates the failback mode was set. Recommended - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 213
Severity INFO CVLM-3006 Message , [CVLM-3006], ,, INFO, , Event: cryptocfg Status: success, Info: Current node WWN/slot / replaced with new node WWN/slot: / . Probable Cause Indicates an HA cluster member was - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 214
[CVLM-3009], ,, INFO, , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is required - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 215
20 CVLM-3013 Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended No action is required. Action Severity INFO CVLM-3013 Message , [CVLM-3013], ,, INFO, , Event: cryptocfg Status: success, Info: LUN , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 216
, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended No action is required. Action Severity INFO CVLM-3017 Message , [CVLM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 217
Message , [CVLM-3021], ,, INFO, , Event: cryptocfg Status: success, Info: Manual rekey all performed. Probable Cause Indicates a complete manual rekey was performed. Recommended No action is required. Action Severity INFO CVLM-3022 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 218
20 CVLM-3024 CVLM-3024 Message , [CVLM-3024], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction aborted. Probable Cause Indicates a transaction abort operation was performed. Recommended No action is required. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 219
20 CVLM-3028 CVLM-3028 Message , [CVLM-3028], ,, INFO, , Event: cryptocfg Status: success, Info: SRDF mode set to . Probable Cause Indicates that the SRDF mode was set. Recommended No action is required. Action Severity INFO Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 220
20 CVLM-3028 144 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 221
INFO DOT1-1003 Message , [DOT1-1003], ,, INFO, 802.1X is enabled for port . Probable Cause Indicates that the 802.1X is enabled for a particular port. Recommended No action is required. Action Severity INFO DOT1-1004 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 222
timestamp>, [DOT1-1006], ,, WARNING, 802.1X Authentication has failed on port . Probable Cause Indicates that the authentication has failed on a particular port. Recommended Check the credentials configured with Supplicant and the RADIUS server. Action Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 223
No action is required. Action Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode. Recommended No action is required. Action Severity INFO Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 224
21 DOT1-1010 148 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 225
FRU faulted. Probable Cause Indicates that a field-replaceable unit (FRU) header could not be read or is not valid. The FRU is faulted. Recommended Action On Brocade 24000 and 48000, try reseating the specified FRU. Restart or power cycle the switch. Fabric OS Message Reference 149 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 226
to verify that the switch does not have hardware problems. To run this command root access is required. Refer to the Fabric OS Command Reference for more information on this command. On the Brocade 24000 and 48000, replace the specified FRU. For the Brocade 3900, replace the motherboard FRU. For - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 227
A reset is sent to the faulty slot or the switch for nonbladed switches. Recommended Action There is most likely a voltage hardware problem on the blade or motherboard of the switch. For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU). For the Brocade 3900 replace - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 228
, replace the FRU. Refer to the Brocade 48000 Hardware Reference Manual for more information about chassisConfig modes and supported blades . Recommended Try reseating the blade. If this fails to correct the error, replace the blade. Action Severity CRITICAL EM-1012 Message , [EM-1012 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 229
failed target state is displayed in the message. There are serious internal Fabric OS configuration or hardware problems on the switch. Recommended Action On Brocade DCX, 24000 and 48000, try reseating the indicated field-replaceable unit (FRU). If the message persists, restart or power cycle the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 230
problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch run the supportSave command and contact your switch service provider. Severity WARNING EM-1017 Message is not compatible with standby firmware version (Pre 4.4), cannot allow HA Sync - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 231
supported by the firmware firmware on the standby to the version replace the WWN card, or the switch (for nonbladed switches). Severity WARNING EM-1029 Message , [EM-1029], ,, WARNING, , , a problem occurred accessing a device on the I2C bus ( - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 232
, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate hardware manual for instructions on inserting the switch blades. Severity ERROR EM-1033 Message , [EM-1033], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 233
22 EM-1035 EM-1035 Message , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the AC main switch/circuit to see if it has power. Fabric OS Message Reference 157 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 234
Id> is not accessible. Probable Cause Indicates that the specified field-replaceable unit (FRU) does not seem to be present on the switch. If the FRU is a world wide name (WWN) card, then default WWN and IP addresses are used for the switch. Recommended Action Reseat the FRU card. If the message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 235
significant sensors for the field-replaceable unit (FRU) are displayed; each contains a header. This message can display: • voltages in volts • temperature in Celsius • fan speeds in RPM Recommended If the message is isolated, monitor the error messages on the switch. If the message is associated - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 236
CP256) is not supported on that chassis (backplane revision D2), remove the blade from the chassis. If the reason is switch configuration, the blade's logical switch configuration is not correct. Run the lscfg command to correct the switch or port configuration for the ports on that blade. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 237
Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 238
and should be replaced. Severity WARNING EM-1058 Message , [EM-1058], ,, WARNING, , Switch gets reset: Probable Cause Indicates the switch is being automatically reset because of a known resetable transient problem such as an application - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 239
replacement is compatible with your switch type. Action Severity ERROR EM-1060 Message , [EM-1060], ,, WARNING, , Stopping synchronization of the system due to blade incompatibility with software version in the system is not supported by the release on the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 240
off because a hardware (HW) application specific integrated circuit (ASIC) ERROR was detected, and you have selected to power off the problem blade when such a condition occurred. Recommended Contact the switch provider for support. Action Severity CRITICAL EM-1065 Message , [EM-1065 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 241
internal Fabric OS configuration or hardware problems on the switch. Recommended Reboot or power cycle the switch. If the message persists, collect switch information using the Action supportsave command, and contact your switch service provider. Severity ERROR EM-1069 Message , [EM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 242
to verify that the switch does not have hardware problems. To run this command root access is required. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 166 Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 243
Action Discontinue the firmware download, identify the downlevel switch or switches that do not support the Coordinated HotCode protocol, and upgrade the downlevel switches. Then, restart the firmware download on this switch. Note that upgrading a downlevel Brocade switch in a mixed interop - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 244
domain id>. Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 245
ESWCH System Messages 24 ESW-1001 Message , [ESW-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates that the switch enable has failed - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 246
into the fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDOwnload Action command. Severity WARNING ESW-1007 Message , [ESW-1007], ,, WARNING, ,Switch port disabled due to \" - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 247
. Probable Cause Indicates that the blade has area swapped ports on ports that do not support this feature. Recommended Replace the blade with ports that support port swap. Refer to the Fabric OS Administrator's Guide Action for more information. Severity WARNING Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 248
24 ESW-1008 172 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 249
EVMD System Messages 25 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 250
25 EVMD-1001 174 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 251
for problems. Run the errShow command on the neighbor switch to view the error log for additional messages. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or SFP if necessary. Run the portLogDumpPort command on both the receiving and transmitting ports - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 252
set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1004 Message , [FABR-1004], ,, WARNING, , port: , req iu: 0x, state: 0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 253
; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1009 Message Probable Cause , [FABR-1009], ,, WARNING, , . Indicates that errors were reported during the exchange fabric parameter state - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 254
FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR FABR-1012 Message , [FABR-1012], ,, WARNING, , : no such type, . Probable Cause Indicates that the fabric - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 255
not enough memory in the switch for the fabric module to allocate. This message is rare and usually indicates a problem with the Fabric OS. switch service provider. Severity CRITICAL FABR-1014 Message , [FABR-1014], , FFDC, ERROR, , Port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 256
system-name>, ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended No name>, Critical fabric size () exceeds supported configuration (). 180 Fabric OS Message Reference 53- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 257
> days hours and minutes. Probable Cause Indicates that this switch has a value-line license and has a limited number of domains. If more system-name>, Fabric size () exceeds supported configuration (). Fabric limit timer () started from - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 258
system-name>, Fabric size is within supported configuration (). Fabric limit timer the limit set by your value-line switches. Value-line switches have a limited fabric size, i.e., a ,, INFO, , Port negotiated - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 259
, the buffer credits are fixed, based on the port configuration information. In this mode, version v2.x has joined the fabric. Probable Cause Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Remove the switch with the unsupported Fabric OS version - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 260
You must manually enable the port or the port remains disabled forever. Refer to the Admin Guide for more enabled port. Persistently disabling port . Probable Cause Indicates the specified port is being disabled because when the port on a Switch is Trunk Area enabled - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 261
is being disabled because when the port attempts to go online, the Switch finds that Trunk Area enabled is incompatible with port configuration such as long distance, port mirror, fast write or EX_port. Recommended Check the port configuration to disable long distance, port mirror, fast write or - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 262
firmware to a VF-capable firmware. Severity ERROR FABR-1045 Message Probable Cause , [FABR-1045], , ERROR, , Detected Base Switch conflict with remote (not neighbor) switch (domain ), BS . No local E-ports - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 263
fabric have the same Base Switch attribute or upgrade the Action switch firmware to a VF-capable firmware. Severity ERROR FABR-1047 Message , [FABR-1047], , INFO, , Area unavailable to assign to the port. Persistently disabling port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 264
inherited FID of the local switch. All E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to Action a VF-capable firmware. Severity ERROR 188 Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 265
by the software. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1004 Message , [FABS-1004], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 266
OS data problem on the switch. The possible values for function name and description of problem are: • error messages on the switch. If the error is repetitive or if the fabric failed, fail over or reboot the switch. If the message persists, run the firmwareDownload command to update the firmware - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 267
unknown event type. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch. If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1011 Message Probable Cause , [FABS-1011 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 268
not be supported by this platform or Fabric OS version. Recommended Action Verify that the blade is valid for use in this system and this version of Fabric OS. Try reseating the blade. If this is a valid blade and reseating does not fix the problem, then replace the blade. Severity ERROR FABS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 269
FRU could not be enabled. This is usually an internal Fabric OS problem. Recommended Action Try removing and reinserting the FRU. Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. Severity ERROR Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 270
27 FABS-1015 194 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 271
. Recommended Action The problem can be corrected by changing the version of firmware on the CP or AP blades. The firmware version on the CP blade firmwareDownload is supported between the versions. As the AP and CP blades cannot communicate, it is not possible to load new firmware on the AP - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 272
28 FBC-1001 196 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 273
is low on memory and failed to allocate new memory for an information unit (IU). Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 274
29 FCMC-1001 198 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 275
timestamp>, [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data that an FIPS failure has occured and requires faulting the blade or switch. Recommended Retry the command. Action Severity CRITICAL FCIP-1002 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 276
Tape Read Pipelining is being disabled slot () port () tunnel (). Probable Cause Indicates that the FOS version on the remote end of the tunnel does not support Tape Read Pipelining. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 277
, , calloc failed for . Probable Cause Indicates a memory failure. Recommended Check the switch memory status. Action Severity ERROR FCOE-1002 Message , [FCOE-1002], ,, WARNING, , Max login Group limit reached at . Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 278
. Probable Cause Indicates that the IfIndex Limit has reached the maximum. Recommended Check the IfIndex Limit. Action Severity ERROR FCOE-1008 Message Probable Cause , [FCOE-1008], ,, INFO, , Free RASLOG fill this later. Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 279
N_port mapping. Action Severity INFO FCOE-1010 Message , [FCOE-1010], ,, ERROR, , Cleanup of login failed for port:. Probable Cause Indicates an invalid port number. Recommended Use the supportsave command and restart the system. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 280
has failed. Recommended Rerequest to add VLAN. Action Severity ERROR FCOE-1014 Message , [FCOE-1014], ,, ERROR, , Request to add ports to VLAN failed. Probable Cause Indicates an add port request to a VLAN has failed. Recommended Rerequest to add - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 281
. Recommended Rerequest to add MACs from L2 for slot/port. Action Severity ERROR FCOE-1019 Message , [FCOE-1019], ,, WARNING, , FLOGI ignored as FC-MAP not configured on FCOE VLAN. Probable Cause Indicates FC-MAP has not been configured on FCOE vlan - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 282
device limit. Recommended Do not add any more FCoE devices to the switch. Action Severity WARNING FCOE-1023 Message , [FCOE-1023], < ,, WARNING, , FCOE logout received on FIP VN port. Indicates a pre-FIP logout for a device that has logged in using - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 283
Change the FCoE login group policy on the switch for the device to login. Action Severity ERROR FCOE-1029 Message , [FCOE-1029], ,, WARNING, , Version mismatch between FIP FDISC and root VN port. Fabric OS Message Reference 207 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 284
FCOE-1030 Message , [FCOE-1030], ,, WARNING, , Version mismatch between FIP LOGO and root VN port. Probable Cause Indicates a version mismatch between the FIP logout and base FLOGI. Recommended No action is required. Action Severity WARNING FCOE-1031 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 285
-1035 Message , [FCOE-1035], ,, INFO, , Virtual FCoE port () enabled. Probable Cause Indicates an administrative action on FCoE port. Recommended No action is required. Action Severity INFO FCOE-1036 Message , [FCOE - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 286
31 FCOE-1036 210 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 287
, , Probing failed on which is possibly a private device which is not supported in this port type Probable Cause Indicates that private devices will not respond to the switch port login (PLOGI) during probing. Recommended Action The Brocade DCX, 4100, 4900, 5000, 7500 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 288
32 FCPD-1003 212 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 289
policy is set to ON. Probable Cause Indicates a device which does not support authentication has tried to log in to the switch when the device authentication policy is in ON status on the switch. Recommended Action Enable the authentication on the device or set the device authentication status to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 290
33 FCPH-1002 214 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 291
action is required. Action Severity INFO FCR-1003 Message , [FCR-1003], ,, INFO, ,FC router physical devices newly exported at port . Probable Cause Indicates that one or more physical devices have been newly exported through the specified - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 292
faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary. Severity INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port . Probable Cause Indicates that a device is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 293
edge fabric. Recommended No action is required. Action Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : . Probable Cause Indicates that a logical storage area network (LSAN) zone was - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 294
, [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended No action is required. Action Severity INFO FCR-1013 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 295
ERROR, , FC router proxy device entries exhausted on port . Probable Cause Indicates that the number of proxy devices is greater than allowed by the port devices are created in the fabric with the port resource problem. LSAN zones are removed using standard zoning commands - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 296
logical storage area network (LSAN) zone entries. Severity ERROR FCR-1023 Message , [FCR-1023], ,, WARNING, , Local phantom port WWN entries exhausted. Probable Cause Indicates that the number of port world wide names (WWNs) in use exceeds the local - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 297
that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical re-enabled. Severity INFO FCR-1027 Message , [FCR-1027], ,, INFO, , In slot port WWN - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 298
be disabled then re-enabled. Severity INFO FCR-1028 Port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected not in use are reused as needed. Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 299
No action is required. Action Severity INFO FCR-1032 Message , [FCR-1032], ,, INFO, , Edge fabric enabled security on port in fabric . Probable Cause Indicates that Secure mode was turned on in the edge fabric. Recommended No - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 300
in the backbone fabric. Probable Cause Indicates that the specified logical storage area network (LSAN) zone was enabled in the backbone fabric. The enabled LSAN zone configuration is listed. Recommended No action is required. Action Severity INFO FCR-1037 Message , [FCR-1037 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 301
: . Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the local switch&apos zone database limitations. Recommended Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN) Action zones - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 302
the supportShow command, and contact your switch service provider. Severity ERROR FCR-1049 Message Probable Cause , [FCR-1049], ,, ERROR, , EX port () received an ELP command that is not supported. Indicates an incoming exchange link protocol - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 303
enable and disable the port. If the problem persists contact your switch service provider. Severity ERROR FCR-1053 Message , [FCR-1053], ,, WARNING, , Port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 304
-to-edge routing is not needed. Otherwise replace the switch with Action one that supports backbone to edge routing. Severity INFO FCR-1057 Message , [FCR-1057], ,, ERROR, , EX_Port() incompatible long distance parameters on link. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 305
, [FCR-1060], ,, WARNING, , EX_Port() has an incompatible configuration setting. Probable Cause Indicates that virtual channel (VC) Link Init is enabled on the local switch and the remote switch is negotiating in R_RDY mode. The fabric might not - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 306
supported EX_ports or VEX_ports was exceeded. To enable the specified port, disable any other operational port then re-enable the port the fabric ID of the switch does not match the local switch. Recommended Run the switchShow number>,, ERROR, , Fabric ID of backbone FC-Routers mismatch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 307
manually re-enable the port. If there is another fabric with the same ID, change the fabric ID for the port using the portCfgExport or portCfgVExport commands. Severity ERROR the fcrState set to 2 (disabled). Note that the FC Routing service is disabled by the factory. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 308
is set to default by user. This removes all prior FC Routing configurations. Recommended No action is required. Action Severity INFO FCR-1071 Message , [FCR-1071], ,, INFO, , Port is changed from non FCR port to FCR port. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 309
that an earlier version of the switch in the backbone or edge that supports a different limit of logical storage area network (LSAN) zones was detected. Recommended Action Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find the lowest supported LSAN zone limits - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 310
re-enable the port. Recommended Make sure to remain within the maximum of supported front domains. Action Severity ERROR FCR-1077 Message , [FCR-1077], ,, WARNING, , Port rejected fabric binding request/check from the M-Model switch; - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 311
Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message. Recommended - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 312
Probable Cause , [FCR-1086], ,, ERROR, , HA sync lost as remote CP does not support Condor2 based EX_ports. Indicates that the remote control processor (CP) has older firmware, which does not support Condor-based EX_ port. This is causing the loss of the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 313
Condor2-based EX_ports or upgrade the remote CP. Action Severity ERROR FCR-1087 Message , [FCR-1087], ,, ERROR, tag added. Probable Cause Indicates that the user has added a LSAN tag. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 314
34 FCR-1092 Recommended No action is required. Action Severity INFO FCR-1092 Message , [FCR-1089], ,, ERROR, , FCR ELS trap entries exhausted. Probable Cause Indicates that the FCR ELS trap entries are exhausted. Recommended Collect supportsave data and - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 315
: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to. HP - Host Port number: This is a 1 byte hexidecimal value that represents the switch port of the switch that the FICON Channel is directly connected to. DD - Device Domain - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 316
Block ID Emulation Enabled or Disabled>. Probable Cause Indicates the configuration was changed manually. Recommended No action is required. Action Severity INFO FICN-1006 Message , [FICN-1006], ,, WARNING, , FICON GEPort < 0 or 1 - GE port number> TID - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 317
Indicates a Selective Reset from the channel was received as either a normal part of path recovery or starting sequence in an error case. Recommended If there was a job failure associated with this event, please contact your vendor's customer support. Action Severity ERROR FICN-1008 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 318
Recommended If there was a job or IO failure associated with this event, please contact your vendor's customer Action support for assistance. Severity ERROR FICN-1013 Message Probable Cause Recommended Action , [FICN-1013], ,, INFO, , DevDiskIng:Status=0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 319
LRC. This indicates data corruption between the emulation processing components. Recommended Please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received Logical Path - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 320
that cannot be associated with a FICON Control Unit CUADDR. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1019 Message , [FICN-1019], ,, ERROR, , DevTapeEgr:AS Link Level Reject (LRJ) from Chan on Path=0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 321
with this event, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1022 Message , [FICN-1022], ,, ERROR, , DevTapeEgr:FICON Selective Reset:Path= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 322
the FICON tape write pipeline is completing an emulated Selective Reset sequence. Recommended If there was an unexpected job failure or IO Error associated with this event, contact your vendor's Action customer support for assistance. Severity INFO FICN-1027 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 323
with this event, contact your vendor's Action customer support for assistance. Severity ERROR FICN-1029 Message , [FICN-1029], ,, ERROR, , HostDiskIng:FICON Selective Reset:Path= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 324
DevicePort LPAR>. Probable Cause Indicates the FICON channel sent a System Reset to the disk control unit. Recommended No action is required. The MVS system was either set to IPL or performing error recovery. Action Severity WARNING FICN-1032 Message , [FICN-1032], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 325
side processing. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1035 Message , [FICN-1035], ,, WARNING, , HostIng:FICON System Reset received on Path= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 326
that could not be associated with a FICON device. Recommended Contact your vendor's customer support for assistance. Action Severity ERROR FICN-1039 Message , [FICN-1039], ,, ERROR, , HostIng:FCUB Lookup failed for Path= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 327
this device>. Probable Cause Indicates that protocol errors in emulation in the CU or network errors can cause a Selective Reset. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1044 Message , [FICN-1044 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 328
status values presented to the channel for this device> treating as system reset event. Probable Cause Indicates an LRJ from a FICON channel indicates that the event, please contact your vendor's customer support for assistance. Action Severity ERROR FICN-1048 Message , [FICN-1048 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 329
it no longer has an established path to its peer. Recommended This is an unexpected event; contact your vendor's customer support for assistance. Action Severity WARNING FICN-1050 Message , [FICN-1050], ,, WARNING, , ProcessEgrTirData:Lost Logical Path - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 330
to break an XRC session with the extended DASD device. Recommended If this was an unexpected event, contact your vendor's customer support for assistance. Action Severity INFO FICN-1053 Message , [FICN-1053], ,, INFO, , XRC Withdraw From Session: SessID - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 331
Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1058 Message , [FICN-1058], ,, ERROR, , Error return from frame generation processing for a FICON control unit: Path= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 332
fast path hash table entry. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR FICN-1062 Message , [FICN-1062], ,, ERROR, , Ingress Abort:Oxid=0x:Path - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 333
> to DID=0x. Probable Cause Indicates an abort operation has been received from a local FC interface for an exchange. Recommended If there were associated IO errors at the same time as this event, contact your vendor's customer Action support for - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 334
abort operation has been received from a local FC interface for an emulaton CU exchange. Recommended If there were associated IO errors at the same time as this event, please contact your vendor's Action customer support for assistance. Severity ERROR FICN-1069 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 335
35 FICN-1070 Recommended If resolution of the configuration issue cannot be completed, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path=< - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 336
35 FICN-1073 FICN-1073 Message , [FICN-1073], ,, INFO, , HostTapeIngr:Unloaded:Path= :states=0x:cmds=0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 337
35 FICN-1076 Severity INFO FICN-1076 Message , [FICN-1076], ,, INFO, , HostTapeIngr:ReadCpReport:Path= :Emuls=0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 338
Last 4 commands received from the channel for this device> lastStatus=0x treating as system reset event. Indicates an LRJ from a FICON channel indicates that the channel does not have a path established to the CU. 262 Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 339
an attached port with the established FICON emulated path has logged out from the switch. Recommended This may be an unexpected event, contact your vendor's customer support for assistance. Action Severity WARNING FICN-1084 Message , [FICN-1084], ,, ERROR, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 340
>,tunnel Id=. Probable Cause Indicates a FICON FCIP tunnel to the peer switch has been terminated. Recommended This is an unexpected event, contact your vendor's customer support for assistance. Action Severity ERROR 264 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 341
the haFailover command. If the problem persists, or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on these commands. Severity ERROR FICU-1003 Message , [FICU - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 342
within the fibre connectivity control unit port (FICON-CUP) daemon failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR FICU-1006 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 343
the supportSave command and contact your switch service provider. Severity WARNING FICU-1008 Message , [FICU-1008], ,, WARNING, , FMS mode has been enabled. Ports: have been disabled due to port address conflict. Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 344
enable failed due to address conflict with port . Probable Cause Indicates that the Fibre Connectivity (FICON) Management Server mode (fmsMode) was not enabled because the specified port , Host data file cannot be resetted to proper size. Probable Cause Indicates that the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 345
received. Recommended No Action is required. Action Severity INFO FICU-1017 Message , [FICU-1017], ,, WARNING, , FMSMODE enable failed because reserved area is bound to a device. Probable Cause Indicates one or both of the reserved areas 0xFE and 0xFF - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 346
are swapped at the time of FMS Mode enable. Recommended Verify expected FICON Port Address / Port Number relationship. Action Severity WARNING FICU-1019 Message , [FICU-1019], ,, INFO, , Switch has been set offline by LP(%s). Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 347
FC8-48 and/or FC8-64 that are not manageable when FMS mode is enabled. Probable Cause Indicates presence of unmanageable ports such as 48 port blade ports in Virtual Fabric disabled chassis. Recommended No action is required. Action Severity ERROR Fabric OS Message Reference 271 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 348
36 FICU-1022 272 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 349
-number>,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 350
37 FKLB-1001 274 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 351
, FFDC, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link support. Recommended Reduce the number of switches in the fabric or reduce the number of redundant ISLs between two Action switches. Severity ERROR - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 352
38 FLOD-1006 Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended No action is required because the LSR is discarded. Action Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 353
number> out of range Probable Cause Indicates that the specified input port number is out of range; it does not exist on the switch. Recommended No action is required. Action Severity ERROR FSPF-1002 Message , [FSPF-1002], ,, INFO, , Wrong neighbor ID - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 354
-number>,, ERROR, , FSPF Version not supported, input port = Probable Cause Indicates that the FSPF version is not supported on the specified input port. Recommended Update the FSPF version by running the firmwareDownload command to update the firmware to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 355
Recommended No action is required. Action Severity INFO 39 FSPF-1008 Fabric OS Message Reference 279 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 356
39 FSPF-1008 280 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 357
persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FSS-1002 Message , [FSS-1002], , SLOT cp-slot-number | CHASSIS, WARNING, , Component - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 358
, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], , SLOT cp-slot-number | CHASSIS, WARNING, , FSS read failure - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 359
by issuing the haSyncStart command. If the problem persists, contact your switch service provider. Severity CRITICAL FSS-1008 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 360
40 FSS-1011 FSS-1011 Message , [FSS-1011], , SLOT cp-slot-number | CHASSIS, INFO, , FSS Info: . Probable Cause Indicates an informational message only. Recommended No action is required. Action Severity INFO 284 Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 361
the Fabric OS Command Reference Manual. Recommended No action is was logged as a result of a user-initiated action (such as running the problem. If the problem persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 362
fails, the failover will be disruptive. In a switch system, this message is logged when a firmware upgrade or downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade or downgrade. Recommended For a dual CP system - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 363
Action end-user installation. To switch. Refer to the hardware reference manual for the environmental temperature range of your switch switch. Recommended This message generally appears when a fan fails. If so, a fan failure message accompanies this Action message. Replace the fan field-replaceable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 364
Cause Indicates that the internal temperature of the switch has changed from a value outside of the particular policy of the Action end-user installation. Severity INFO FW-1009 Message < . If the power supply continues to be a problem, replace the faulty power supply. Severity INFO FW-1010 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 365
acceptable range. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1033 Message , [FW-1033], ,, INFO, , , value has changed(High= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 366
threshold, the SFP is deteriorating. Recommended Incoming laser fluctuations usually indicate a deteriorating SFP. If this message occurs repeatedly, Action replace the SFP. Severity INFO FW-1038 Message , [FW-1038], ,, WARNING, , , is below low - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 367
deteriorating. Recommended Verify that your optical components are clean and function properly. Replace deteriorating cables Action or SFPs. Check for damage as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1041 Message , [FW-1041], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 368
or not. If the counter often exceeds the threshold, the SFP is deteriorating. Recommended Verify that your optical components are clean and function properly. Replace deteriorating cables Action or SFPs. Check for damage from heat or age. Severity WARNING FW-1043 Message , [FW-1043 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 369
message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1045 Message , [FW-1045], boundary. Recommended Verify that your optical components are clean and function properly. Replace deteriorating cables Action or SFPs. Check for damage - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 370
as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1049 Message , [FW-1049], to 0 Action (Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates. Severity WARNING FW-1051 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 371
indication that the SFP is deteriorating. Replace the SFP. Action Severity WARNING FW- to the particular policy of the Action end-user installation. Severity INFO FW-1113 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 372
appropriate to the particular policy of the end-user installation. Check both ends of the physical following actions can cause a fabric reconfiguration: • two switches with the same domain ID have connected to one another transient error and might not require troubleshooting. Severity INFO 296 Fabric - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 373
can cause a fabric reconfiguration: • Two switches with the same domain ID have connected to the particular policy of the Action end-user installation. Severity INFO FW-1119 Message reconfiguration might be a transient error and might not require troubleshooting. Severity INFO FW-1120 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 374
has to assign another domain ID to the switch. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1122 Message , [FW-1122], ,, INFO, , , is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 375
this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1124 Message , [FW-1124], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 376
. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors means that the fabric is functioning normally - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 377
zone configuration. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1130 Message , [FW-1130], ,, INFO, , , is below low boundary(High= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 378
message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1134 Message , [FW-1134], fabric logins has fallen below the low boundary. Fabric logins occur when a port or device initializes with the fabric. The event is called a fabric login - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 379
the acceptable range. Fabric logins occur when a port or device initializes with the fabric. The event the particular policy of the Action end-user installation. Severity INFO FW-1137 Message < of SFP state changes means that the switch is functioning normally. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 380
loss of signal and fails. Both physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Recommended Action Check both ends of your cable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 381
physical and hardware problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization. Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number of link loss errors means that the switch is functioning normally - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 382
errors, troubleshoot your host bus adaptor (HBA) and contact your switch service provider. Severity INFO FW-1165 Message , [FW-1165], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 383
the number of synchronization losses that the port experiences has changed from a value problem. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. A low number of signal loss errors means that the switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 384
that the number of protocol errors that the port experiences has fallen below the low boundary. Occasional protocol errors occur due to software glitches. Persistent protocol errors occur due to hardware problems. A low number of protocol errors means that the switch is functioning normally. 308 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 385
protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1176 Message , [FW-1176], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 386
invalid words that the port experiences has fallen below the low boundary. Invalid words usually indicate a hardware problem with an small form switch is functioning normally. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 387
port experiences has changed. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. Frequent fluctuations in CRC errors Action end-user installation. A low number of invalid CRCs means that the switch is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 388
in CRC errors generally indicate an aging fabric. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware is clean. Severity INFO FW-1184 Message , [FW-1184], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 389
Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1189 Message , [FW-1189], ,, INFO, , , , is below low boundary(High=, Low=). Current value is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 390
Action end-user installation. Severity INFO FW-1193 Message , [FW-1193], ,, INFO, , , < has segmented, or has become a trunk port. A low number of port state changes means that the switch is functioning normally. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 391
Action end-user installation. Severity WARNING FW-1195 Message , [FW-1195], ,, INFO, , , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 392
Cause Indicates that the number of link resets that the port experiences has risen above the high boundary. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended Check both ends of - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 393
Message , [FW-1201], ,, INFO, , , , is below low boundaries (High=, Low= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 394
by adding more links to the trunk. Action Severity WARNING FW-1207 Message , [FW-1207], ,, INFO, , , , is between high and low boundaries (High=, Low=). Current value is . Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 395
that the number of end-to-end (EE) word frames that the switch receives has changed. Receive performance messages appear due to the number of word message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1246 Message , [FW-1246], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 396
message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1248 Message , [FW-1248], < that the number of end-to-end (EE) word frames that the switch transmits has changed. Transmit performance messages appear due to the number of word - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 397
that the switch transmits has changed port has received small computer system interface (SCSI) Read, SCSI Write, SCSI Read and Write, SCSI Traffic, or IP commands in a frame. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 398
number of frame types or commands that the port receives has changed from a value outside of the acceptable range to a value switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 399
that are authorized to establish Telnet connections to switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 400
are authorized to establish browser connections to the switches in the fabric. Recommended Action Run the errShow command to determine the IP address that sent the request. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 401
indicate that a browser connection request has been received from an unauthorized IP address. The HTTP_POLICY contains a list of internet protocol (IP) addresses that are authorized to establish browser connections to the switches in the fabric. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 402
done through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity INFO 326 Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 403
through the name server. Recommended Action Run the errShow command to determine the device WWN, switch WWN, and switch port. Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. Severity WARNING FW-1339 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 404
for the specification of rules for binding device ports (typically host bus adaptor (HBA) ports) to specific switch ports. DCC policies ensure that whenever a device command to determine the IP location of the login attempt. Responses to security-class messages depend on user policies. Consult your - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 405
to determine the IP location of the login attempt. Responses to security-class messages depend on user policies. Consult your FCS). When the FCS downloads a new configuration to the other switches in the fabric, the packet is signed using the private key of the primary FCS. The receiving switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 406
server (FCS). When the primary FCS downloads a new configuration to the other switches in the FCS switch. If verification fails, it rejects the packet. This counter keeps track of the number of packets received with invalid signatures. Recommended Responses to security-class messages depend on user - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 407
failures has changed. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly, or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 408
the low boundary. Authentication failures can occur for many reasons. The switch on the other side might not support the protocol, have an invalid certificate, not be signed properly or send unexpected packets. The port where authentication fails is segmented. This counter keeps track of the number - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 409
value is . Probable Cause Indicates that the number of time service (TS) out-of-sync violations has changed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies. Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 410
fabric, but it still has the WWN of the last primary FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response strategies and policies - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 411
FCS switch, it increments this counter and resets the WWN of the primary FCS to all zeroes. Recommended Responses to security-class messages depend on user of secure switches with different version stamps have been detected. When a switch is in secure mode, it connects only to another switch that is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 412
only to another switch that is in secure mode and has a compatible security database. A compatible security database means that the version stamp and fabric configuration server (FCS) policy matches exactly. Recommended Responses to security-class messages depend on user policies. Consult your - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 413
command that can be executed only on a backup FCS switch. The counter increments every time someone issues one of these commands on a switch where it is not allowed. Recommended Responses to security-class messages depend on user policies. Consult your security administrator Action for response - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 414
server (FCS) switch have been executed on a non-primary FCS switch. There are many commands that can be executed only on the primary FCS switch as well future problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 415
slightly with normal operation of the switch. Excessive permanent increases can lead to future problems. Recommended You might have to remove message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1404 Message , [FW-1404], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 416
Severity INFO FW-1424 Message Probable Cause , [FW-1424], ,, WARNING, , Switch status changed from to . Indicates that the switch status is not in a healthy state. This occurred because of a policy violation. 340 Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 417
end-user installation. Severity INFO FW-1426 Message , [FW-1426], ,, WARNING, , Switch status Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 418
or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 419
same level of firmware to both CPs. Replace any faulty CPs. If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to clear the problem. Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 420
(CRC) error, Port state change or Buffer Limited Port is above the high boundary. Recommended Replace any faulty or deteriorating small form-factor pluggables (SFPs). Action Severity WARNING FW-1437 Message , [FW-1437], ,, WARNING, , Switch status change - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 421
ports. Severity WARNING FW-1439 Message , [FW-1439], ,, WARNING, , Switch status change contributing factor Switch offline. Probable Cause Indicates that the switch that the state of the specified field-replaceable unit (FRU) has changed to "inserted - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 422
(FRU) has changed to "faulty". Recommended Replace the FRU. Action Severity WARNING FW-1445 Message Probable Cause , [FW-1445], ,, INFO, , Four power supplies are now required for 2X redundancy, Switch Status Policy values changed. Indicates that the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 423
for full (2X) redundancy, but the user has previously overridden the Switch Status Policy values pertaining to number of power supplies. So those values will not be automatically changed. The default values with no AP blades are: 3 out of service indicates switch status is DOWN, 0 indicates no - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 424
errors and, if applicable, troubleshoot them. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1512 Message , [FW-1512], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 425
errors and, if applicable, troubleshoot them. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1513 Message , [FW-1513], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 426
protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1518 Message , [FW-1518], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 427
protocol errors occur due to hardware problems. Recommended No action is required. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1519 Message , [FW-1519], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 428
in CRC errors generally indicate an aging fabric. Check your small form-factor pluggables (SFPs), cables, and connections for faulty hardware. Verify that all optical hardware is clean. Severity INFO FW-1522 Message , [FW-1522], ,, INFO, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 429
. Respond to this message as is appropriate to the particular policy of the Action end-user installation. Severity INFO FW-1526 Message , [FW-1526], ,, INFO, , , , has dropped below upper threshold boundary to in between(High= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 430
of link resets that the port experiences has changed and crossed lower threshold boundary to a value within the acceptable range. Link resets occur due to link timeout errors that indicate no frame activity at all. Both physical and hardware problems can cause link resets to increase. Recommended - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 431
Message , [FW-1532], ,, INFO, , , , has dropped below upper threshold boundary to in between(High , [FW-1534], ,, INFO, , , , has dropped below threshold boundary to in between(High - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 432
String> loss area in class since FOS6.3. Disabling port fencing feature for this. Probable Cause Indicates that in previous versions portfencing is configured for Link/Sync loss, but after upgrading to new version, in which portfencing is not suppoted, resets the above bit. Recommended - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 433
Respond to this message as it is appropriate to the particular policy of the end-user installation. Action Severity INFO FW-3015 Message , [FW-3015], ,, INFO, , , is below low boundary(High=, Low=). Current value - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 434
, [FW-3017], ,, INFO, , , is between high and low boundary(High=, Low=< the end-user installation. Action Severity INFO FW-3019 Message , [FW-3019], ,, INFO, , , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 435
testing. Recommended No action is required. Action Severity WARNING FW-3021 Message , [FW-3021], ,, WARNING, , , is below low boundary(High=, Low=). Current value is Probable Cause Indicates the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 436
42 FW-3021 360 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 437
problem persists, replace Action the standby CP. Run the supportSave command and contact your switch service errors that might initiate this message are hardware errors, software errors, compact flash errors, or memory errors. The reboot reasons can be any of the following: • Hafailover • Reset - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 438
• Reboot:API • Reboot:HAM • EMFault:EM Recommended Check the error log on both CPs for additional messages that might indicate the reason diagnostic test on the EMAC controller and will wait for the standby CP to reset it if it is down. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 439
auto-reboot is enabled, the system will automatically reboot itself. Otherwise you need to manually reboot it. Recommended For a reliable recovery, reboot the system manually if auto-reboot recovery is disabled. Run the Action supportSave command and contact your switch service provider. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 440
is detected when system is not ready for warm recovery. Recommended Manually trigger reboot for cold recovery if needed, or wait until system CHASSIS, CRITICAL, ,Password database conversion failed. Probable Cause Indicates the password database conversion failed. Recommended No - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 441
-number | CHASSIS, CRITICAL, . Probable Cause Indicates a software watchdog detected termination of a restartable daemon and needed to reboot/failover. Recommended If needed manually initiate a reboot/failover. Action Severity CRITICAL Fabric OS Message Reference 365 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 442
43 HAM-1014 366 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 443
transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL HAMK-1002 Message , such as the firmwareDownload command, the standby CP blade being reset or removed, of an error in the standby CP blade. Recommended Action Monitor the standby - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 444
of heartbeat. This message is typically seen when the standby CP has been rebooted. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 445
Cause Indicates that the blade voltage is above threshold. Recommended Replace the faulty blade or switch (for nonbladed switches). Action Severity ERROR HIL-1102 Message , [HIL-1102], ,, ERROR, , Slot faulted, ( - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 446
not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100 , 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. Severity ERROR HIL-1106 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 447
not have field-replaceable units (FRUs). For the Brocade 3900, replace the motherboard FRU. For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both power supplies; if any other voltage is faulty, replace the entire switch. Severity ERROR HIL-1108 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 448
is not applicable to the Brocade 24000 or 48000. Recommended Action For the Brocade 3900 replace the fan FRU. For the Brocade 3016, 3250 and 3850, the entire switch must be replaced because these switches do not have field-replaceable units (FRUs). Severity ERROR 372 Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 449
. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000. Recommended For the Brocade 4100, 4900, 7500, and AP7600, replace the fan field-replaceable unit (FRU). Action Severity ERROR HIL-1207 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 450
unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Replace the affected fan FRU immediately. Action Severity WARNING HIL-1302 Message , [HIL-1302], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 451
often preceded by a low fan speed message. Recommended Replace the faulty fan FRUs immediately. Action Severity ERROR HIL-1306 Message , [HIL-1306], ,, ERROR, , Three fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that three - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 452
fan speed message. Recommended Replace the faulty fan field-replaceable unit (FRU)s immediately. Action Severity ERROR HIL-1310 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 453
number>,, WARNING, , fan FRUs missing. Install fan FRUs immediately. Probable Cause Indicates that one or more fan field-replaceable units (FRUs) have been removed. Recommended Install the missing fan FRUs immediately. Action Severity WARNING HIL-1501 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 454
well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the faulty blade. Severity CRITICAL HIL-1504 Message Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 455
fans are working properly. Replace any deteriorating fan field-replaceable units (FRUs). Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 456
. To help prevent future problems, make sure that all the fans are working properly. Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 457
that all fans are operating correctly. Replace any deteriorating fan field-replaceable units (FRUs). Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch. Try rebooting or power cycling the switch. Severity ERROR HIL-1602 Message , [HIL - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 458
unit is faulty. Applicable only to Brocade 5100. Recommended Ensure that the power cord is connected to the unit with a valid power source and then switch on Action the unit. If the problem persists, try reseating the unit. If the problem still persists replace the FRU. Severity WARNING HIL-1650 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 459
>, [HLO-1003], , FFDC, ERROR, , Invalid Hello received from port , Domain = , Remote Port =. Indicates that the HLO message received was invalid and the frame was dropped. The Brocade switch will not accept FSPF frames from the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 460
an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended The HLO message of the remote switch must be compatible with the value specified in - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 461
Action Run the firmwareDownload command to reinstall the firmware to your switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 385 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 462
47 HMON-1001 386 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 463
Chapter HSL System Messages 48 HSL-1000 Message , [HSL-1000], ,, CRITICAL, , HSL initialization failed. Probable Cause Indicates an HSL initialization failure. Recommended No action is required. Action Severity CRITICAL HSL-1001 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 464
Indicates an incompatible SFP for the interface has been inserted. Recommended Use the correct SFP for this interface. Action Severity ERROR HSL-1005 Message , [HSL-1005], ,, CRITICAL, , Failed to initialize with FSS. Probable Cause Indicates a failure - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 465
48 HSL-1007 Recommended Install more memory on board. Action Severity CRITICAL HSL-1007 Message , [HSL-1007], ,, ERROR, , Failed to read SFP for interface . Probable Cause Indicates a failure to read an SFP. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 466
48 HSL-1007 390 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 467
>, [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that initiated by User: , Role: could not be completed successfully - . Probable Cause Indicates an error in completing - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 468
49 HTTP-1003 392 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 469
50 IBD-1001 Message , [IBD-1001], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 470
50 IBD-1001 394 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 471
name>, iSCSI login sessions exceed the maximum limit at slot port ge Probable Cause Indicates that the iSCSI login sessions exceed the supported limit per port. Recommended Use another port to log in. Action Severity WARNING Fabric OS Message Reference 395 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 472
51 IBPD-1003 396 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 473
the switch. Severity ERROR ICPD-1002 Message , [ICPD-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the ICPD failed. Recommended Download a new firmware version using - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 474
ICPD-1006 Message , [ICPD-1006], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates the iSCSI service is enabled or disabled on the switch. Recommended No action is required. Action Severity INFO ICPD-1007 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 475
Recommended No action is required. Action Severity INFO 52 ICPD-1008 Fabric OS Message Reference 399 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 476
52 ICPD-1008 400 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 477
of address change> . Probable Cause Indicates that a change in the local IP address has occurred. If the source of the address change is manual, this means that the address change was initiated by a user. If the source of the address change is the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 478
53 IPAD-1001 402 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 479
switch. Severity WARNING IPS-1002 Message , [IPS-1002], ,, ERROR, , Failed to initialize rc = Probable Cause Indicates that an initialization of a module within the IPS daemon failed. Recommended Download a new firmware version using - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 480
the remote side to set up Action the tunnel. Severity WARNING IPS-1006 Message , [IPS-1006], ,, WARNING, , Tunnel Configuration Mismatch for slot () port() tunnel ID() reason () Probable Cause Indicates that tunnel - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 481
[ISCS-1000], ,, ERROR, , Slot Port GE crashed unexpectedly. Probable Cause Indicates the specified port has crashed. Recommended No action is required; the port will restart automatically. Action Severity ERROR Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 482
55 ISCS-1000 406 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 483
INFO, , Peering with external iSNS server is disabled. Probable Cause Indicates the IP address of the internet storage name service (iSNS) server is zero. Hence peering is disabled. Recommended If you wish to enable the iSNS server, use the isnscCfg command to show or set the server - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 484
request re-register with external iSNS server slot/port /ge. Probable Cause Indicates a user has requested a re-register with the specified external internet storage name service (iSNS) server. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 485
. Refer to the appropriate hardware reference manual for valid slot and Action port ranges. Severity WARNING ISNS-1011 Message , [ISNS-1011], ,, INFO, , iSNS Client Service is . Probable Cause Indicates the current - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 486
-name>, Start peering with external iSNS server on management port. Probable Cause Indicates that peering has started with the specified external internet storage name service (iSNS) on the management port. Recommended No action is required. Action Severity INFO 410 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 487
is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1006 Message , [KAC-1006], ,, ERROR, , Switch to key vault trustee link was not established. Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 488
configured key value is operational, and if it is not, change the switch key Action vault settings or resolve the operational problem at the vault. Severity ERROR KAC-1008 Message , [KAC-1008], ,, ERROR, , Putting TEP failed check if there is already an - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 489
. An abort signal is sent. Recommended Copy the warning message along with any core file information, and contact your switch service Action provider. Severity WARNING KSWD-1002 Message , [KSWD-1002], , FFDC, WARNING, , Detected termination of - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 490
58 KSWD-1002 414 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 491
dump has not completed. Recommended No action is required. Action Severity INFO KTRC-1003 Message , [KTRC-1003], ,, ERROR, , Cannot open ATA dump device Probable Cause Indicates the ATA dump driver is not initialized properly. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 492
59 KTRC-1005 Recommended No action is required. Action Severity ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 493
that the l2sys encountered with System Service Manager (SSM) message queue errors. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1004 Message Probable Cause , [L2SS-1004], ,, ERROR, , FDB error: Error in creating AVL tree. Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 494
Probable Cause Indicates a mac-address-table hash failure happened even after two hash changes on the chip. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1006 Message , [L2SS-1006], ,, INFO, , Mac-address-table table on slot - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 495
initialization of a module within the LACP daemon has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR Fabric OS Message Reference 419 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 496
61 LACP-1001 420 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 497
62 LANCE-1000 Message , [LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the port is disabled. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 498
62 LANCE-1000 422 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 499
Manager service is enabled by the factory setting and it is not user configurable. Recommended No action is required. Action Severity INFO LFM-1003 Message , [LFM-1003], ,, INFO, , The Logical Fabric Manager configuration is set to default. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 500
the reason for the port disable using the Action switchshow command. Rectify the disable based on the reason. Severity WARNING LFM-1006 Message , [LFM-1006], ,, WARNING, , The switch with domain with firmware version has joined the FID - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 501
and contact your switch service provider. Severity WARNING error logging system. A trace dump file is created. The message might still be visible through SNMP or other management tools. Recommended Action Run the reboot command for nonbladed switches or the haFailover command on bladed switches - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 502
64 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended No action is required. Action Severity INFO 426 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 503
through 239. The switch will discard the record because it is not supported. Recommended No action is required. Action Severity ERROR LSDB-1002 Message version of the LSR (link state record). The switch generates its local link state record when first enabled. By disabling and enabling the switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 504
for domain Probable Cause Indicates there is no link state record for the specified local domain. Recommended No action is required. The other switch will pass the LSD once the fabric is stable. Action Severity WARNING 428 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 505
; then run the supportSave command and contact your switch service provider. Severity ERROR MFIC-1002 Message , [MFIC-1002], ,, INFO, , Chassis FRU header not programmed for switch NID, using defaults (applies only to FICON environments). Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 506
66 MFIC-1003 Recommended Action IDID mode is a fabric-wide mode; make sure that any switches added to the fabric are configured with the same IDID mode as the fabric. If you are enabling or disabling IDID mode, this message is for information purposes only, and no action is required. IDID mode can - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 507
lsrP, lsId = Probable Cause Indicates a link state record is null. Recommended No action is required. Action Severity ERROR MPTH-1003 Message , [MPTH-1003], ,, WARNING, , No minimum cost path in candidate list Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 508
67 MPTH-1003 432 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 509
• 12 - MSG_US • 13 - MSG_EXT_RSCN • 14 - MSG_RDTS_START • 15 - MSG_RDTS_SENDEFP • 16 - MSG_RDTS_RESET Recommended No action is required. Action Severity ERROR MQ-1005 Message , [MQ-1005], ,, WARNING, , queue : queue full (miss= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 510
68 MQ-1006 MQ-1006 Message , [MQ-1006], ,, WARNING, , queue : msg too long (:) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended No action is required. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 511
Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Restart or power cycle the switch. Action Severity WARNING MS-1002 Message , [MS-1002 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 512
command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS number is the target domain that caused error. Recommended Action The fabric might be reconfiguring supportSave command and contact your switch service provider. Severity INFO MS-1004 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 513
) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR MS-1008 Message , [MS-1008], ,, ERROR, , MS Failure while initializing Probable Cause Indicates the management server - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 514
sequence-number>,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . < SAN hardware problems such as bad cables or small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages persist. Severity ERROR - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 515
Cause Indicates the management server (MS) has disabled E-port port number connected to domain domain because implicit enable operation of platform service is blocked. Recommended Enable Platform service on the switch and renable the port to join the fabric. Action Severity WARNING Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 516
69 MS-1026 440 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 517
, execute the haFailover command. If the problem persists or if this is a nonbladed switch, download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR MSTP-2001 Message , [MSTP - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 518
70 MSTP-2002 Recommended No action is required Action Severity INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: New Root: Probable Cause Indicates that the MSTP - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 519
70 MSTP-2006 Recommended No action is required. Action Severity INFO MSTP-2006 Message , [MSTP-2006], ,, INFO, , MSTP instance brigde priority is changed from to . Probable Cause Indicates that the MSTP instance - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 520
70 MSTP-2006 444 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 521
Database Acknowledge Wait • 4 - Database Wait • 5 - Full If this error occurs repeatedly, then there is a problem in the protocol implementation between two switches. Recommended Action Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 522
ERROR NBFS-1003 Message , [NBFS-1003], ,, WARNING, , DB_XMIT_SET flag not set in state , input , port . The Fabric OS automatically recovers from this problem. Action Severity WARNING 446 Fabric OS Message Reference 53 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 523
the remote switch with firmware v4.3 or higher, or v3.2 or higher, as appropriate for the switch type, so that it can support GMI to the name server on the standby CP has lower supported capability than the active CP because of different firmware versions running on the active and standby CPs. This - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 524
of the lowest version of firmware. Severity INFO NS-1005 Message , [NS-1005], ,, WARNING, , Zone size of has over the supporting limit of for the remote switch domain ID . Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 525
the Open FR license or relocate Open FR devices to a licensed switch. Action Severity WARNING NS-1009 Message , [NS-1009], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 526
in fabric id . Probable Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not Action be setup correctly. Severity WARNING 450 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 527
link is up. Action Severity INFO NSM-1004 Message Probable Cause , [NSM-1004], ,, INFO, , Creating a Port-Channel interface . Indicates that the new Portchannel interface has been created. Fabric OS Message Reference 451 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 528
Vlan name> is in use. First remove all the FCoE sessions of its member ports and then try again to disable it. Probable Cause Indicates that the FCoE VLAN is . Probable Cause Indicates the chassis is disabled or enabled. Recommended No action is required. Action Severity INFO NSM-1008 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 529
73 NSM-1009 Recommended No action is required. Action Severity INFO NSM-1009 Message , [NSM-1009], ,, INFO, , Interface is deleted. Probable Cause Indicates that the logical interface has been deleted. Recommended No action is required. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 530
73 NSM-1013 Recommended No action is required. Action Severity INFO NSM-1013 Message , [NSM-1013], ,, INFO, , Vlan classifier group is deleted. Probable Cause Indicates that Vlan classifier group has been deleted. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 531
73 NSM-1017 Recommended No action is required. Action Severity INFO NSM-1017 Message , [NSM-1017], ,, INFO, , Interface is on interface . Probable Cause Indicates that logical interface member list has been - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 532
Enable the DCE ports after bringing up the core blades. Action Severity INFO NSM-1022 Message , [NSM-1022], ,, WARNING, , . Probable Cause Indicates internal error information. Recommended To be transmitted to engineering for problem - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 533
Messages 74 ONMD-1000 Message , [ONMD-1000], ,, INFO, , LLDP is enabled. Probable Cause Indicates that LLDP is globally enabled. Recommended No action is required. Action Severity INFO ONMD-1001 Message , [ONMD-1001], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 534
74 ONMD-1004 Recommended No action is required. Action Severity INFO ONMD-1004 Message , [ONMD-1004], ,, INFO, , LLDP is disabled on interface . Probable Cause Indicates that LLDP is disabled on interface. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 535
Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1002 Message , [PDM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 536
Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1006 Message , [PDM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 537
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1009 Message , [PDM-1009], ,, WARNING, , Can't update Port Config Data. Probable Cause Indicates the parity data manager (PDM) system - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 538
Action Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING PDM-1012 Message , [PDM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 539
firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service ,, WARNING, , Failed to download area port map. Fabric OS Message Reference 463 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 540
service provider. Severity WARNING PDM-1022 Message , [PDM-1022], ,, WARNING, , The switch is configured only with IPv6. Probable Cause Indicates that the parity data manager (PDM) cannot synchronize with its peer because the firmware does not support - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 541
The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved. Recommended Run the pdShow command to view the panic dump and core dump files - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 542
76 PDTR-1002 466 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 543
your switch service provider. experience a double reset and reboot twice error condtion or being fenced or isolated from the I2C bus. Recommended Reboot the CP if it does not reboot itself. Reseat the CP if rebooting does not solve the problem. If Action the problem still persists, then replace - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 544
Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected. Recommended The FRU must be replaced. Action Severity CRITICAL 468 Fabric OS Message Reference 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 545
INFO PMGR-1004 Message Probable Cause , [PMGR-1004], , WARNING, ,Attempt to create switch failed. Error message: . Indicates that the switch with the specified FID was not deleted. Fabric OS Message Reference 469 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 546
, WARNING, , Attempt to move port(s) on slot to switch failed. Error message: . Probable Cause Indicates the unsuccessful attempt to move the ports to the specified switch. Recommended No action is required. Action Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 547
to switch failed. Error message: . Probable Cause Indicates the failed attempt to change the base switch. Recommended No action is required. Action Severity WARNING PMGR-1011 Message , [PMGR-1011], , INFO, , Attempt to move ports to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 548
78 PMGR-1011 472 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 549
had multiple failures that exceeded an internally set threshold on the port. This problem is typically related to hardware. Recommended Action Check and replace (if necessary) the hardware attached to both ends of the specified port number, including: • the media (SFPs) • the cable (fiber optic or - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 550
Recommended No action is required. Action Severity INFO PORT-1008 Message , [PORT-1008], ,, INFO, , GigE Port (ID: ) has been enabled. Probable Cause Indicates a GbE port has been enabled. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 551
Recommended No action is required. Action Severity INFO PORT-1010 Message , [PORT-1010], ,, WARNING, , Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 552
79 PORT-1010 476 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 553
error has occurred in Advanced Performance Monitoring (APM). The performance monitor has failed to initialize. Recommended The control processor (CP) should restart (or fail over) automatically If this does not happen, restart Action or power cycle the switch to re-initiate the firmware 's Guide for - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 554
80 PS-1004 Probable Cause Indicates that the restoring configuration has failed to set the end-to-end monitoring mask on at least one ISL port. Recommended No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is Action enabled. ISL monitoring can only be - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 555
particular fabric. Recommended Action No action required. Top Talker cannot be installed on fabric with FC router or McData mode enabled. In case if the top talker has to be installed on fabric, FC router and McData mode has to be disabled. Severity WARNING Fabric OS Message Reference 479 53 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 556
80 PS-1007 480 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 557
INFO PSWP-1002 Message , [PSWP-1002], ,, INFO, , Port Swap feature enabled. Probable Cause Indicates that the portSwap feature has been enabled in the switch. Recommended No action is required. Action Severity INFO PSWP-1003 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 558
failed on fabosInit with error code in switch number . Probable Cause Indicates that the bladeSwap command has failed to access the switch context. Recommended Retry the command. If the failure persists, contact your support representative. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 559
[RAS-1004], , FFDC, WARNING, , Software 'verify' error detected. Probable Cause Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1005 Message , [RAS-1005 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 560
error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1006 Message , [RAS-1006], , INFO, , Support user> '. Probable Cause Indicates that the support data file is transferred from the switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 561
INFO RAS-3002 Message , [RAS-3002], , INFO, , USB storage device enabled. Probable Cause Indicates that the USB storage device is enabled. Recommended No action is required. Action Severity INFO RAS-3003 Message , [RAS-3003], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 562
82 RAS-3004 Recommended No action is required. Action Severity INFO 486 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 563
, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity INFO RCS-1002 Message , [RCS-1002], ,, INFO, , RCS has been enabled. Probable Cause Indicates that the RCS feature has been - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 564
in Fabric OS v2.6, v3.1 and later, and v4.1 and later. Run the firmwareDownload command to upgrade the firmware for any switches that do not support RCS. Severity ERROR RCS-1005 Message , [RCS-1005], ,, INFO, , Phase , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 565
83 RCS-1007 Severity INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 566
83 RCS-1008 490 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 567
Indicates that a First time encryption/re-key/Write Metadata was not started. Recommended Correct the Cluster Ethernet link error and retry. Action Severity ERROR RKD-1003 Message , [RKD-1003], ,, CRITICAL, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 568
84 RKD-1004 RKD-1004 Message , [RKD-1004], ,, INFO, , Message: . Probable Cause Indicates the generic rekey message. Recommended No action is required. Action Severity INFO RKD-1005 Message , [RKD-1005], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 569
Chapter RMOND System Messages 85 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Probable Cause Indicates that the threshold level has exceeded for the sample type of RMON alarm. Recommended Check the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 570
85 RMON-1002 494 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 571
Error: client \"\" has bad credentials: Probable Cause Indicates an authentication error was reported. The specified client IP missing. Recommended To enable RPCD in secure mode, install a valid SSL certificate on the switch. Action Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 572
Secure RPCd is disabled. Probable Cause Indicates the SSL certificate file has been corrupted. Recommended To enable RPCD in Secure mode, install a valid SSL certificate in the switch. Action Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 573
see if the specified domain ID is online. Enable the switch with the specified domain ID. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity WARNING Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 574
ID is reachable. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers and run the supportSave command then contact your switch service provider. Severity INFO 498 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 575
Chapter SAS System Messages 88 SAS-1001 Message , [SAS-1001], ,, ERROR, , string description of command which failed> of GE failed. Please retry the command. Data inst= st= rsn= - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 576
88 SAS-1001 500 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 577
valid values for daemon name are listed below. For a complete listing, see the Introduction to this manual. • fabricd • asd • evmd • fcpd • webd • msd • nsd • psd • snmpd supportSave command and contact your switch service provider. Severity CRITICAL Fabric OS Message Reference 501 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 578
89 SCN-1001 502 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 579
on all switches in the fabric to be enabled. If all switches are capable, RCS is automatically enabled. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 580
the specified number of attempts, and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries. Recommended Action Reset the version stamp on the switch to '0' using the secVersionReset command and then rejoin the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 581
reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the the switch through the Telnet connection. Action Severity INFO SEC-1010 Message Probable Cause , [SEC-1010], ,, ERROR, < - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 582
error by executing the command only from Primary FCS. Action Severity ERROR SEC-1016 Message , [SEC-1016], ,, INFO, , Security violation: Unauthorized host with IP address - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 583
>,, ERROR, , Invalid IP address () detected. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 584
server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the switch. Severity ERROR SEC-1031 Message , [SEC-1031], ,, WARNING, , Current security policy DB cannot be supported - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 585
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 586
. If it is not, then re-run the command using the correct domain Action ID. Severity ERROR SEC-1040 Message , [SEC-1040], ,, ERROR, , Invalid portlist (). Cannot combine * with port member in the same portlist. Probable Cause Indicates the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 587
is not within the minimum and maximum range. Recommended Use valid syntax when entering port ranges. Action Severity ERROR SEC-1044 Message , [SEC-1044], ,, ERROR, , Duplicate member in (). Fabric OS Message Reference 511 53-1001767 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 588
-number>,, ERROR, , Too many port members. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 589
ERROR, , Missing brace for port list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 590
should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1055 Message , [SEC-1055], ,, ERROR, , Invalid FCS list Probable Cause Indicates there - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 591
the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 592
domains or domains more than the maximum number supported are specified. Recommended Enter the correct number of domains. Action Severity ERROR SEC-1063 Message , [SEC-1063], ,, ERROR, , Failed to reset statistics. Probable Cause Indicates that either the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 593
) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR SEC-1071 Message , [SEC-1071], ,, ERROR, , No new security policy data to apply. Probable Cause Indicates that no changes - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 594
the operation in non-secure mode. In secure mode, run the command from a switch that has required privilege, that is, either a backup FCS or primary FCS. Severity ERROR SEC-1075 Message , [SEC-1075], ,, ERROR, , Fail to new policy set on all - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 595
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 596
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 597
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 598
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 599
should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1093 Message , [SEC-1093], ,, ERROR, , New FCS list must have at least one member in common with - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 600
FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR SEC-1098 Message , [SEC-1098], ,, ERROR, , No FCS list. Probable Cause Indicates the specified policy could not be found - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 601
1099], ,, ERROR, , Please enable your switch before running secModeEnable. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 602
switch failed to download a certificate, security database, or policies. This can happen when the switch Guide. Severity ERROR SEC-1105 Message , [SEC-1105], ,, ERROR, , Fail to disable secure mode on all switches. Probable Cause Indicates the switch - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 603
. Severity INFO SEC-1108 Message , [SEC-1108], ,, ERROR, , Fail to reset stamp on all switches. Probable Cause Indicates that a version reset operation failed either because the switch could not get all the required resources to perform the operation or - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 604
, [SEC-1112], ,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Indicates that either a security policy download is attempted with an active policy that - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 605
save the data received by the primary fabric configuration server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or multiple user authentication data. Recommended Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 606
in fabric are in the ready state. When Action all switches are in the ready state, retry the operation. Severity INFO SEC-1123 Message , [SEC-1123], ,, INFO, , Security database downloaded by Primary FCS. 530 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 607
Cause Indicates the security database was successfully downloaded from the primary fabric configuration server (FCS). Recommended No action is required. , The Primary FCS has failed over to a new switch. Probable Cause Indicates an FCS failover operation was completed successfully. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 608
SEC-1136], ,, ERROR, , Failed to verify signature . Probable Cause Indicates the receiving switch fails to validate the security database sent from the primary fabric configuration server (FCS) switch. This message usually indicates that - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 609
download received from Primary FCS. Probable Cause Indicates that a non-primary fabric configuration server (FCS) switch received a security database download the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that switch. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 610
on the fabric. RCS must be capable on all switches in the fabric to be enabled. If all switches are capable, it is automatically enabled. For any switch that does not support RCS, obtain the latest firmware version from your switch supplier, and run the firmwareDownload command to upgrade the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 611
database exceeds the maximum size. This message can also be caused when the switch is short of memory. The status values can be either defined, active, or resources for a security policy failed due to low memory or internal error. The status values can be either defined, active, or both. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 612
the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 613
on a non-FCS switch. Probable Cause Indicates the attempt to enable security is made on a switch that is not present in the fabric configuration server (FCS) list. Recommended Add the switch to the FCS policy list when using the lockdown option to enable security. Action Severity ERROR SEC-1165 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 614
not be correctly updated for that specific switch. Severity ERROR SEC-1170 Message , [SEC-1170], ,, INFO, , This command must be executed on the Primary FCS switch, the first reachable switch in the FCS list. Probable Cause Indicates there has been - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 615
is required; if not, check the primary FCS. Action Severity ERROR SEC-1174 Message Probable Cause , [SEC-1174], ,, ERROR, , Failed to set password. Indicates the FCS or non-FCS password could not be set. Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 616
ERROR, , Failed to generate new version stamp. Probable Cause Indicates the primary fabric configuration server (FCS) failed to generate a new version stamp due to the fabric not being stable. Recommended Verify all switches -name>, Deleted account Indicates the specified - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 617
[SEC-1183], ,, ERROR, , Policy to binary conversion error: Port is out range. Probable FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SEC-1184 Message , [SEC-1184], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 618
switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service node name> tries to FLOGI to index/area of switch . Indicates a device connection control (DCC) security - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 619
Severity INFO SEC-1190 Message , [SEC-1190], ,, INFO, , Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause Indicates an SNMP security violation was reported. The specified unauthorized host - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 620
error message lists the violating IP address. Verify that this IP address is being used by a valid Action switch admin. Use the correct password server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 621
>,, WARNING, , Switch does not have all default account names. Probable Cause Indicates the default switch accounts admin and user do not exist on the switch when enabling security. Recommended Reset the default admin and user account names on the switch that reported the warning and - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 622
. If so, add the host IP address to the API policy of the Unauthorized access to serial port of switch . Probable Cause Indicates FCS) switch. Recommended Action Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 623
port name - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 624
run the supportSave command and contact your switch service provider. Severity ERROR SEC-1300 Message , [SEC-1300], ,, INFO, , This switch is in VcEncode mode. Security is not supported. Probable Cause Indicates the switch is set up with VC-encoded mode - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 625
configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the the firmware to the latest version for your specific Action switch. Verify the firmware you are installing supports the Brocade Secure Fabric - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 626
switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch Administrator's Guide. If PKI objects are valid, verify that an unauthorized switch is not -in user service (RADIUS/LDAP) server responded to a switch request. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 627
1311], ,, ERROR, , Security mode cannot be enabled because one or more of the password policies is not set to default value. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric have password policies that are not - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 628
parameters were set to default values. Probable Cause Indicates the passwdCfg parameters were set to default values. Recommended Action Verify IP address failed. Recommended Restart the system to fix this error. If the problem persists contact your switch service provider. Action Severity ERROR - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 629
to the fabric, as specified by Domain Number, have a conflicting policy with the local switch. Recommended Check the conflicting policy and make the new swithces and the local switch policies the same. Action Severity WARNING SEC-1317 Message , [SEC-1317], ,, INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 630
WARNING SEC-1321 Message , [SEC-1321], ,, ERROR, , Failed secure mode enable command. Reason: . Probable Cause Indicates the security enable failed on the fabric because the switch has a conflicting configuration such as fabric wide consistency - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 631
system-name>, Fabric transaction failure. RCS error: Probable Cause Indicates the reliable commit service (RCS) transaction failed with the -1325], ,, ERROR, , Security enforcement: Switch connecting to port is not authorized to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 632
Policy is enabled on the switch. Recommended Verify IP filter policy enforcement failed due to internal system failure. Recommended Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command Action and contact your switch service provider. Severity ERROR - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 633
, [SEC-1331], ,, ERROR, , Attempt to enable secure mode failed. Reason: . Probable Cause Indicates the secModeEnable command failed on the fabric because default IP Filter policies are not active on the switch, or an active transaction exists on - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 634
-number>, AUDIT, INFO, , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policies. Probable Cause Indicates that that the specified IP filter policy has not been saved. Recommended Action Verify that the security event was planned. If the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 635
Connection Type>. Probable Cause Indicates that a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Action Severity INFO SEC-3050 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 636
90 SEC-3061 Recommended No action is required. Action Severity INFO SEC-3061 Message , [SEC-3061], , AUDIT, INFO, , Role is created. Probable Cause Indicates a role name was created. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 637
Cause Indicates the configuration of user-defined roles are downloaded. Recommended No action is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in . Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 638
90 SEC-4001 562 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 639
Message , [SFLO-1002], ,, INFO, , sFlow is for port . Probable Cause Indicates that the sFlow is enabled or disabled for a particular port. Recommended No action is required. Action Severity INFO SFLO-1003 Message , [SFLO-1003 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 640
is changed to . Probable Cause Indicates that the polling interval has changed on the port. Recommended No action is required. Action Severity INFO SFLO-1007 Message , [SFLO-1007], ,, INFO, , is as as sFlow - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 641
Recommended No action is required. Action Severity INFO 91 SFLO-1008 Fabric OS Message Reference 565 53-1001338-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 642
91 SFLO-1008 566 Fabric OS Message Reference 53-1001338-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 643
-number>,, ERROR, , SNMP service is not available . Probable Cause Indicates the simple network management protocol (SNMP) service could not be started because of the specified Reason. You will not be able to query the switch through SNMP. Recommended Verify the IP address for - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 644
the SNMP service will not work correctly. Recommended Change the SNMP configuration back to the default. Action Severity ERROR SNMP-1005 Message was reset to default Probable Cause Indicates the simple network management protocol (SNMP) configuration group was reset to the factory default. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 645
92 SNMP-1008 Severity INFO SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Execute the nsshow command to view the current device status. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 646
92 SNMP-1008 570 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 647
containing Encryption Engine>, Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended , perform a fastboot command on the switch to recover the system. Severity ERROR Fabric OS Message Reference 571 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 648
the Crypto subsystem cover is tampered. Recommended EE is zeroized. User needs to run initEE and regEE. Action Severity CRITICAL SPC- ERROR, , , : FPGA firmware download failed: 0x%x. Probable Cause Indicates the FPGA download - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 649
Encryption Engine>, : FPGA firmware download success: 0x%x. Probable Cause Indicates the FPGA download was successful. Recommended No action >, : Vader/OB1 recovered from error. Probable Cause Indicates the Crypto error from FPGA de-asserted. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 650
,, CRITICAL, , , : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. Recommended EE is zeroized. Run the initEE and regEE commands. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 651
key vaults such as RKM, recover the missing Master Key to current or alternate Action position. Severity ERROR SPC-3003 Message , [SPC-3003], ,, ERROR, , , : No output KEK for DEK rewrap, DEK: - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 652
• 32 - DEK could not be unwrapped • 33 - FGPA error upon inject • 73 - Invalid KEK format Recommended Contact technical support. Action Severity ERROR SPC-3006 Message , [SPC-3006], ,, ERROR, , , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 653
other - Internal error Recommended For status code 14, complete primary KEK generation; otherwise, contact technical support. Action Severity ERROR SPC-3008 Message mismatch, certificate: . Probable Cause Indicates the FIPS certificate within the Crypto - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 654
regEE commands, then recover or restore the needed primary and secondary KEKs. Action Severity ERROR SPC-3013 Message Probable Cause , [SPC-3013], ,, ERROR, , , : SEK generation failure: - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 655
Indicates the Crypto Module internal random number generator has failed. Recommended Contact technical support. Action Severity ERROR SPC-3015 Message , [SPC-3015], ,, ERROR, , , : RSA pairwise key - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 656
93 SPC-3015 580 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 657
and restart the switch. Action Severity ERROR SPM-1002 Message based on the reason displayed. Recommended Run the supportsave command to gather information. Action Severity WARNING SPM-1003 Message , [SPM-1003], ,, INFO, , Set New Group Cfg SC Enable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 658
94 SPM-1005 Recommended No action is required. Action Severity INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended No action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 659
is missing. Probable Cause Indicates that a key vault certificate is missing. Recommended Deregister and register this key vault. Action Severity ERROR SPM-1011 Message , [SPM-1011], ,, INFO, , Group Cfg Changed Quorum Size . Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 660
to manually sync security db. Action Severity ERROR SPM-1014 Message , [SPM-1014], ,, WARNING, , Warning: Configdownload results in EE going to Operational; Need valid KEK state. Probable Cause Indicates the Master Keys downloaded - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 661
>, [SPM-3004], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot enabled. Probable Cause Indicates an encryption engine was enabled. Recommended No action is required. Action Severity INFO SPM-3005 Message Probable Cause , [SPM-3005 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 662
Message , [SPM-3008], ,, INFO, ,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM-3009 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 663
-name>,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended No action is required. Action Severity INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 664
94 SPM-3014 Recommended No action is required. Action Severity INFO SPM-3014 Message , [SPM-3014], ,, INFO, ,Event: cryptocfg Status: success, Info: Key archive client registered with certificate file \"\". Probable Cause Indicates a KAC - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 665
94 SPM-3018 Recommended No action is required. Action Severity INFO SPM-3018 Message , [SPM-3018], ,, INFO, ,Event: cryptocfg Status: success, Info: master key recovered. Probable Cause Indicates a master key was recovered. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 666
>,, INFO, ,Event: cryptocfg Status: success, Info: System card . Probable Cause Indicates use of the system card was enabled or disabled. Recommended No action is required. Action Severity INFO SPM-3024 Message , [SPM-3024], ,, INFO - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 667
94 SPM-3026 Recommended No action is required. Action Severity INFO SPM-3026 Message , [SPM-3026], ,, INFO, ,Event: cryptocfg Status: success, Info: File exported via usb: Source: Destination: . Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 668
94 SPM-3029 Recommended No action is required. Action Severity INFO 592 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 669
support information to a remote location. Recommended No action is required. Action Severity INFO SS-1001 Message , [SS-1001], ,, WARNING, , supportSave's upload operation to host IP address aborted. Probable Cause Indicates a file copy error - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 670
errors in subcommands being executed by the supportSave command. Recommended Run the usbstorage command to check the USB storage device settings. After the USB problem >. Reason: No IP connection. Probable Cause Indicates the IP connection between Active switch and then run the supportsave - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 671
request. Probable Cause Indicates no reponse from the blade in the corresponding slot for the given supportsave request. Recommended Reboot the switch and then run the supportsave command. Action Severity WARNING SS-1008 Message , [SS-1008], ,, WARNING, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 672
95 SS-1008 596 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 673
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR cycle the switch. Action Severity ERROR SSMD-1004 Message , [SSMD-1004], ,, ERROR, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 674
Recommended Action Restart or power cycle the switch .If the condition persists then download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for more information on this command. Severity ERROR SSMD-1200 Message , [SSMD-1200 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 675
ASIC / . Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in initializing the dataplane ASIC QoS infrastructure. Recommended Restart or power cycle the switch. Action Severity WARNING SSMD-1205 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 676
Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Default CoS feature. Recommended Delete and reapply the QoS interface Default CoS policy. Restart or power cycle the switch. Action Severity WARNING SSMD - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 677
the QoS interface CoS Mutation policy. Restart or power cycle the switch. Action Severity WARNING SSMD-1210 Message , [SSMD-1210], Scheduler Control. Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 678
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Pause feature. Recommended Delete and reapply the QoS Pause policy. Restart or power cycle the switch. Action Severity WARNING 602 Fabric - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 679
,QoS CEE could not comply with FCoE scheduler policy for CEE Map . Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE configuration into an ETS scheduler policy implementable by the dataplane ASIC. Recommended Redefine - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 680
96 SSMD-1303 SSMD-1303 Message , [SSMD-1303], ,, INFO, , CEEMap priority group with weight is created with pfc . Probable Cause Indicates that priority Group has been created. Recommended No action is required. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 681
96 SSMD-1307 SSMD-1307 Message , [SSMD-1307], ,, INFO, , access list is created. Probable Cause Indicates that Access List has been created. Recommended No action is required. Action Severity INFO SSMD-1308 Message , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 682
timestamp>, [SSMD-1313], ,, INFO, , removed from interface . Probable Cause Indicates that user profile Map is removed from interface. Recommended No action is required. Action Severity INFO SSMD-1314 Message , [SSMD - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 683
Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is command for more information. Run the firmwareShow command to verify the firmware versions. Severity INFO SULB-1003 Message , [SULB-1003], < - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 684
. Probable Cause Indicates the previous standby CP has now become the active CP and is running the new firmware version. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Run the firmwareDownloadStatus command for more information. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 685
failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby CP failed to reboot due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 686
TABLE 6 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "Unable to restore the original firmware due to Standby CP timeout." "Standby CP failed to reboot and was not responding - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 687
started to restore the secondary partition." 0x93 "firmwareCommit failed." 0x94 "The secondary partition has been restored successfully." 0x95 "Firmware is being downloaded to the blade. This step may take up to 10 minutes." 0xa0 "firmwareDownload timed out." 0xa1 "Reboot occurred during - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 688
The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware version file." 0x16 "Unexpected system error." 0x17 "Error in getting lock device for firmwareDownload." 0x18 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 689
of some common error messages: 0x15 - Failed to download Red Hat package manager (RPM) package. If this error occurs immediately after firmwareDownload is started, the firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 690
cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server. It may also be caused by - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 691
to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message , [SULB-1010], , AUDIT, INFO, , Firmwarecommit failed (status=0x - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 692
the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message , [SULB-1021],, AUDIT, WARNING, , Firmware is being downloaded to the blade in slot . Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 693
there may be an error caused by an unexpected firmware version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 694
progress. If the problem persists, contact your switch service provider. Severity WARNING SULB-1031 Message Probable Cause , [SULB-1031], , AUDIT, WARNING, , The switch is relocating an internal firmware image. Indicates the switch has rebooted with the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 695
. Recommended Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure the switch is enabled. Severity WARNING SULB-1034 Message , [SULB-1034], , AUDIT, ERROR, , Relocation of internal image timed out - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 696
relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1036 Message , [SULB-1036], ,, INFO, , . Probable Cause Indicates the firmware version is running in the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 697
Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 698
97 SULB-1040 622 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 699
>. Probable Cause Indicates the switch is enabled before it is ready. Recommended If the message persists, run the supportFtp command (as needed) to set up automatic FTP Action transfers; then run the supportSave command and contact your switch service provider. Severity ERROR SWCH-1002 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 700
fabric. Recommended Load a firmware version on standby that supports NPIV functionality, using the firmwareDownload Action command. Severity WARNING SWCH-1007 Message Probable Cause , [SWCH-1007], ,, WARNING, , Switch port disabled due to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 701
blade is enabled with the port configuration that does not support port swap. Recommended Action Replace the blade with ports that support port swap. Then swap the ports back to the ports default area. Refer to the Fabric OS Administrator's Guide for more information on port swapping. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 702
Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 703
problem or due to file corruption. Recommended Action Restart or power cycle the switch If the message persists, run the firmwareDownload command to update the firmware on it. This is not a supported configuration. Remove the WWN-PID binding and re-enable the port and then run the wwnaddress -- - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 704
be assigned because it is user bound to a different port. Remove the WWN-PID binding or remove portAddress binding and re-enable the port and then run the not support dynamic area on default switch. Recommended Load a firmware version on the standby CP that supports dynamic area on default switch, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 705
string)>:. services or to fail over to active status. Recommended Action The switch is in an inconsistent state and can be corrected only by a restart or power cycle. Before restarting the chassis, record the firmware version on the switch is not supported by - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 706
WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action As indicated in firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware Use the supportSave command to gather troubleshooting data. Issue a reboot or haFailover - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 707
SYSM-1002], ,, INFO, , , Switch: Probable Cause Indicates a user has executed either the switchShutdown or switchReboot command. All services are brought down for a logical switch. Recommended Action No action is required if the switchShutdown - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 708
name (WWN) card is present and operational and that the affected Action control processor (CP) is properly seated in its slot. Severity ERROR SYSM-1005 Message , [SYSM-1005], , FFDC, CRITICAL, , CP blade in slot failed to retrieve current - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 709
TAPE System Messages Chapter 101 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 710
101 TAPE-1001 634 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 711
MANUAL, TRIGGER)>) Probable Cause Indicates that trace dump files have been generated on the switch contact your switch service provider. Severity switch automatically. Recommended No action is required. Action Severity INFO TRCE-1003 Message , [TRCE-1003], ,, ERROR - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 712
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave Action command and contact your switch service provider. Severity ERROR TRCE-1006 Message , [TRCE-1006], ,, INFO, , FTP Connectivity Test succeeded to FTP site ' - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 713
and contact your switch service provider. Severity ERROR TRCE-1008 Message ERROR, , Unable to alert active CP that a dump has occurred. Probable Cause Indicates that the standby CP is unable to communicate trace information to active CP. This message is only applicable to the Brocade - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 714
your switch service provider. Severity ERROR TRCE-1011 Message , [TRCE-1011], ,, INFO, , Trace dump manually is enabled and retry the command. If the blade is already enabled, run the Action supportSave command and contact your switch service provider. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 715
occurs if the user name or password is incorrect. Recommended Action This message indicates a typing error by the user. If this message occurs repeatedly, it might indicate an unauthorized user trying to gain access to a switch. When Secure mode is enabled on the fabric, the IP address of a failed - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 716
the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration Track-changes on. Probable Cause Indicates the track change feature has been enabled. Recommended No action is required. Run the trackChangesSet 0 command to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 717
that the principal or primary FCS switch has the clock server IP configured correctly. Verify this clock server is accessible to the switch and functional. If the principal or primary FCS does not support the feature, either choose a different switch for the role or reset the clock server to LOCL - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 718
one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits. • Synchronizing time of day . For example, during fabric reconfiguration or role change of the primary FCS switch. If the message does not recur, it should be ignored. Recommended - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 719
name>, Inconsistent route detected: Port = , should be Probable Cause Indicates the switch detected an inconsistency in the port number displayed is what the protocol is using. Recommended Run the switchDisable command and then the switchEnable command to reset the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 720
>, [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 721
because the enabled TI zone is not compatible with the fabric configuration. Probable Cause Indicates the specified switch is unreachable because of the TI zone and the fabric configuration incompatibility. Recommended Clear all TI zones and refer to the TI zone user manual for instructions on how - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 722
106 UPTH-1002 646 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 723
WEBD System Messages Chapter 107 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL certificate file is either invalid or absent. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 724
will be restarted due to change of IP Address. Probable Cause Indicates the IP address of the switch changed and the HTTP server is restarted. Cause Indicates a rare error condition, where the built-in recovery process has failed to restore HTTP services. The problem often results from invalid - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 725
a memory allocation failure. Recommended Contact your customer support for assistance. Action Severity ERROR XTUN-1002 Message , [XTUN-1002], ,, ERROR, , Exchange timeout:I/T/L: . Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 726
job failure associated with this event, contact your customer support for Action assistance. Severity ERROR XTUN-1004 Message , [XTUN-1004], ,, ERROR, , Exchange aborted:I/T/L: . Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 727
or Action disruption has occurred. Severity ERROR XTUN-2004 Message Probable Cause , [XTUN-2004], ,, INFO, , FCIP Tunnel Pri QoS UP. Indicates that the specified quality of service for this tunnel is up. This applies to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 728
Class> Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class goes disabled or deleted, a possible network error or Action disruption has occurred. Severity INFO 652 Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 729
, or a faulty cable between peer ports. Recommended Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have Action deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable if necessary. Severity ERROR Fabric OS Message Reference 653 53 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 730
109 ZEUS-1001 654 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 731
ZOLB-1001 Message , [ZOLB-1001], ,, ERROR, , ZONELIB Probable Cause Indicates there was an internal timeout on the these core files and contact your switch service provider. Severity ERROR Fabric OS Message Reference 655 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 732
110 ZOLB-1001 656 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 733
number>) which does not exist. Probable Cause Indicates the port zone member that is targeted for the local switch contains a non-existent port. The effective zoning configuration (displayed in the error message) contains a port number that is out of range. Recommended Edit the zone database and - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 734
using one method or the other to define all objects in the zoning database. If the devices on the port are defined by a mixture of port IDs and WWNs, the zone enforcement is session based. If the S_ID list of the hardware-enforced zoning overflows (over the S_ID limit), the hardware zone enforcement - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 735
of the error message. This is usually a programming error when adding problem. • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch message occurs only when enabling a zone configuration. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 736
zoning configuration is enabled on the switch, it will not be supported. Recommended Edit the zone database to remove the QuickLoop zoning definition in the effective configuration. Action Severity WARNING ZONE-1014 Message , [ZONE-1014], ,, ERROR, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 737
= 5) QuickLoop zones are not supported in Fabric OS v4.x and above. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity ERROR ZONE-1019 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 738
operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 739
: An error was received for an unknown reason. • User Command: A user aborted the current zoning transaction. • Switch Shutting Down: The switch is currently switches in your fabric. Refer to the Fabric OS Administrator's Guide for information on the zone database sizes supported for each switch. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 740
automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING ZONE-1030 Message , [ZONE-1030], number>,, ERROR, , Switch is in interop mode. (switch, port) members not supported. Probable Cause Indicates the switch is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 741
the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1036 Message , [ZONE-1036], ,, ERROR, , Unable to create - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 742
file. Typically the zone configuration is too large for the memory available on the switch. Recommended Reduce the size of the zone database and retry the operation. Action Severity ERROR ZONE-1040 Message , [ZONE-1040], ,, INFO, , Merged zone database - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 743
Check the SFP and cable at the specified port and verify that they are not faulty. Replace the SFP Action and cable as necessary. Severity -number>,, INFO, , The Default Zone access mode is set to No Access. Probable Cause Indicates the Default Zone access mode is set to No - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 744
-name>, The Default Zone access mode is already set to All Access. Probable Cause Indicates the Default Zone access mode Switch domain () does not support defined database. Probable Cause Indicates a remote Brocade switch is running a downlevel version of Fabric OS that does not support - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 745
AD-DefZone conflict. Recommended Check and resolve the default zone mismatch issue. Action Severity ERROR ZONE-1050 Message , [ZONE-1050], ,, INFO, , The Interop Safe Zoning mode is set to Enabled. Probable Cause Indicates that the Interop Safe Zoning - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 746
zones or disable McDATA default zoning. Action Severity WARNING ZONE-1056 Message , [ZONE-1056], ,, WARNING, , Non-ETIZ-Capable Switch (dom ) in fabric w/ETIZ Configured. Probable Cause Indicates the config Save/Enable/Disable operations will - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 747
TI Zone has domain running pre FOS6.4.0 firmware. TI member (Domain , Index ) is not supported. Probable Cause Indicates that an unsupported port index(> 511) is present in the TI zone path - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 748
111 ZONE-1057 672 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 749
699 •AUDIT FICU System Messages 701 •AUDIT FW System Messages 703 •AUDIT HTTP System Messages 705 •AUDIT IPAD System Messages 707 •AUDIT PORT System Messages 709 •AUDIT SEC System Messages 711 •AUDIT SNMP System Messages 729 •AUDIT SPM System Messages 731 •AUDIT SULB System Messages 739 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 750
674 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 751
. Action Severity INFO AG-1036 Message AUDIT, , [AG-1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Fabric OS Message Reference 675 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 752
the ports is connected to a Non-Brocade Fabric. Recommended No action is required. Action Severity WARNING AG-1037 Message AUDIT, , [AG-1037], ,, INFO, ,Trunked N_Port () going offline, if switchshow CLI for the connected fabric switch port displays - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 753
affected by this condition. Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this port. This latency may be inherent in the device or due to heavy workload on the device. For an E_Port, it indicates a downstream primary bottleneck - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 754
Indicates that the bottleneck detection configuration was changed by a user. Recommended No action is required. Action Severity INFO AN- slot number> port . Probable Cause Indicates a credit loss. Recommended Contact your vendor's customer support for assistance - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 755
,, ERROR, , Certificate not present in this switch in port . Probable Cause transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1046 Message AUDIT, , [AUTH-1046], - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 756
AUTH-3004 Message AUDIT, , [AUTH-3004], INFO, SECURITY, , , , Event: , Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port disabled. 680 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 757
port is off, correct the switch policy configuration on either of the switches using the authUtil command, and then enable the port on the neighboring switch transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3007 Message AUDIT, , - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 758
switch/device. The error might indicate that an invalid entity attempted to connect to the switch. Recommended Action Check the connection port FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO AUTH-3008 Message AUDIT, , [AUTH - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 759
AUDIT BLS System Messages Chapter 115 BLS-1002 Message , [BLS-1002], ,, INFO, , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec or IKE policy was added and the configuration file was updated. Recommended No action is required. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 760
115 BLS-1003 684 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 761
AUDIT CNM System Messages Chapter 116 CNM-3001 Message AUDIT, , [CNM-3001], INFO, , , , , Event: cryptocfg Status: success, Info: encryption group \\ created. Probable Cause Indicates an encryption group was created. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 762
116 CNM-3004 CNM-3004 Message AUDIT, , [CNM-3004], INFO, , , , , Event: cryptocfg Status: success, Info: Membernode \\ ejected from encryption group. Probable Cause Indicates a membernode was ejected from an encryption group. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 763
CNM-3008 116 Severity INFO CNM-3008 Message AUDIT, , [CNM-3008], INFO, , , , , Event: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Probable Cause Indicates that the encryption engine (EE) routing - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 764
116 CNM-3012 Recommended No action is required. Action Severity INFO CNM-3012 Message AUDIT, , [CNM-3012], ,, INFO, , Deleteing an EG with luns setup for encryption can lead to luns being disabled if Encryption Group name is not preserved (). - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 765
of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description . There are several possible causes. Recommended Check the error log, correct the error and rerun the configDownload command. Action Fabric OS Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 766
was unsuccessful because there are one or more parameters that require the switch to be disabled. Recommended Disable the switch using the switchDisable command and download the configuration. Action Severity WARNING CONF-1042 Message , [CONF-1042], ,, INFO, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 767
AUDIT CVLM System Messages Chapter 118 CVLM-3001 Message AUDIT, , [CVLM-3001], INFO, , , , , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates that the failback mode was set. Recommended No - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 768
-3006 Message AUDIT, , [CVLM-3006], INFO, , , , , Event: cryptocfg Status: success, Info: Current node WWN/slot / replaced with new node WWN/slot: / . Probable Cause Indicates a HA cluster member was - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 769
-3009], INFO, , , , , Event: cryptocfg Status: success, Info: Manual failback from EE / to EE /. Probable Cause Indicates a manual failback was performed to an encryption engine. Recommended No action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 770
118 CVLM-3012 Recommended No action is required. Action Severity INFO CVLM-3012 Message AUDIT, , [CVLM-3012], INFO, , , , , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \< - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 771
, Info: Lun , attached through Initiator \\, in crypto target container \\ enabled. Probable Cause Indicates a LUN in a cryptotarget container was enabled. Recommended No action is required. Action Severity INFO CVLM-3017 Message AUDIT, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 772
CVLM-3020 Message AUDIT, , [CVLM-3020], INFO, , , , , Event: cryptocfg Status: success, Info: Manual rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 773
118 CVLM-3022 CVLM-3022 Message AUDIT, , [CVLM-3022], INFO, , , , , Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 774
118 CVLM-3026 Severity INFO CVLM-3026 Message AUDIT, , [CVLM-3026], ,, INFO, , Event: cryptocfg Status: failed, Info: Decommission of device (container initiator , LUN ). Probable Cause Indicates that the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 775
AUDIT FCIP System Messages Chapter 119 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended No action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 776
119 FCIP-1003 700 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 777
mode has been enabled. Probable Cause Indicates that the FICON Management server mode has been enabled. Recommended No switch. Recommended No action is required. Action Severity INFO FICU-1020 Message Probable Cause AUDIT, , [FICU-1020], ,, INFO, , Port - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 778
120 FICU-1021 Recommended No action is required. Action Severity INFO FICU-1021 Message AUDIT, , [FICU-1021], ,, INFO, , Port Addrs (%s) have been UnBlocked by %s. Probable Cause Indicates the Fibre Connectivity (FICON) Management server has unblocked - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 779
, , , , Event: , Status: success, Info: Probable Cause Indicates that Port Fencing was enabled/disabled successfully. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 703 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 780
121 FW-3001 704 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 781
, ZONE, , , , Zoning transaction initiated by User: , Role: could not be completed successfully - . Probable Cause Indicates an error occurred while completing the zoning transaction. Recommended Verify that the event - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 782
122 HTTP-1003 706 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 783
[IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 707 53 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 784
123 IPAD-1002 708 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 785
action is required. Action Severity INFO PORT-1008 Message AUDIT, , [PORT-1008], INFO, CFG, , , , GigE Port (ID: ) has been enabled. Probable Cause Indicates a GigE port has been enabled. Recommended No action is required. Action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 786
124 PORT-1009 Probable Cause Indicates a GigE port has been disabled. Recommended No action is required. Action Severity INFO 710 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 787
WARNING SEC-3001 Message AUDIT, , [SEC-3001], INFO, SECURITY, , , , Event: , Status: success, Info: Security mode on the fabric. Probable Cause Indicates the security mode of the fabric was either - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 788
) failover. • A security policy has been activated. • A security policy has been saved. • A security policy has been aborted. • A non-FCS password has changed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 789
-details>, , , Event: , Status: success, Info: Removed members from policy . Probable Cause Indicates a user has removed the specific members from the specified security policy. Note: If you use a wildcard (for example, an asterisk) in - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 790
, Info: FCS member moved from position to . Probable Cause Indicates the fabric configuration server (FCS) list has >, Status: success, Info: Reset [] statistics on domains []. Indicates that a user has reset a security statistic on the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 791
name>]. Probable Cause Indicates a user has reset the password for the specified user accounts. Recommended Action Verify the password was intentionally reset. If the password was intentionally reset, no action is required. If the password was not intentionally reset, take appropriate action as - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 792
: success, Info: Moved RADIUS server to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS) server. Recommended Action Verify the RADIUS server position was intentionally changed. If the RADIUS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 793
: Passwdcfg parameters set to default values. Probable Cause Indicates the passwdCfg parameters are set to default values. Recommended Action Verify the attempt via . Probable Cause Indicates a successful login occurred. An IP address is displayed when the login - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 794
may manually unlock the account. Severity INFO SEC-3024 Message AUDIT, , [SEC-3024], INFO, SECURITY, , , , Event: , Status: success, Info: User account [], password changed. Probable Cause Indicates the user's password - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 795
>, [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added. Role: [], Password [], Home AD [], AD list []. Probable Cause Indicates a new - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 796
, SECURITY, , , , Event: , Status: success, Info: Backup user account \"\" recovered. Probable Cause Indicates that back user accounts were recovered. Recommended Action Verify the security event was planned. If the security - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 797
Event: , Status: success, Info: Switch is configured to - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 798
3038], INFO, SECURITY, , , , Event: ipfilter, Status: failed, Info: Failed to activate . Probable Cause Indicates the specified IP filter policy failed to activate. Recommended Action Verify the security event was planned. If the security - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 799
. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Check for unauthorized access to the switch through the specified protocol connection. Take Action appropriate action as defined - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 800
execute this command. Recommended Verify the user has the required permission to execute this command. Action Severity INFO SEC-3048 Message AUDIT, , [SEC-3048], INFO, SECURITY, , , FIPS mode has been enabled in the system using force option - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 801
SEC-3051 125 Probable Cause Indicates the specified sshutil operation was performed.. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 802
Cause Indicates the configuration of user-defined roles are downloaded. Recommended No action is required. Action Severity INFO SEC-4001 Message , [SEC-4001], , AUDIT, INFO, , Client logged in . 726 Fabric OS - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 803
Probable Cause Indicates the client has logged in. Recommended No action is required. Action Severity INFO SEC-4001 125 Fabric OS Message Reference 727 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 804
125 SEC-4001 728 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 805
that the simple network management protocol (SNMP) configuration s incorrect and the SNMP service will not work correctly. Recommended Reset the SNMP configuration to default. Action Severity ERROR SNMP-1005 Message AUDIT, , [SNMP-1005], INFO, CONFIGURATION, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 806
126 SNMP-1006 730 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 807
. Action Severity INFO SPM-3004 Message AUDIT, , [SPM-3004], INFO, , ,,Event: cryptocfg Status: success, Info: EE in slot enabled. Fabric OS Message Reference 731 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 808
127 SPM-3005 Probable Cause Indicates an encryption engine was enabled. Recommended No action is required. Action Severity INFO SPM-3005 Message AUDIT, , [SPM-3005], INFO, , ,,Event: cryptocfg Status: success, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 809
, , [SPM-3008], INFO, , ,,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended No action is required. Action Severity INFO SPM - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 810
-location>,,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 811
SPM-3016 127 Severity INFO SPM-3016 Message AUDIT, , [SPM-3016], INFO, , ,,Event: cryptocfg Status: success, Info: Master key generated. Probable Cause Indicates a master key was generated. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 812
AUDIT, , [SPM-3023], INFO, , ,,Event: cryptocfg Status: success, Info: System card . Indicates use of the system card was enabled or disabled. 736 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 813
SPM-3024 127 Recommended No action is required. Action Severity INFO SPM-3024 Message AUDIT, , [SPM-3024], INFO, , ,,Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 814
127 SPM-3028 Probable Cause Indicates a recovery card was registered. Recommended No action is required. Action Severity INFO SPM-3028 Message AUDIT, , [SPM-3028], ,, INFO, , Event: SPM-EE state changed, Info: EE State: . Probable Cause - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 815
Cause Indicates the firmwareDownload command has completed successfully and switch firmware has been updated. Recommended Action No action is required command to verify the firmware versions. Severity INFO SULB-1003 Message AUDIT, , [SULB-1003], INFO, FIRMWARE, - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 816
failed." "firmwareDownload failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "firmwareDownload failed due to IPC error." "firmwareDownload failed due to IPC error." "Standby CP failed to reboot due to IPC error." 0x30 0x31 0x32 0x33 0x34 0x35 0x36 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 817
TABLE 9 Status Messages and Status Codes Status Message "firmwareCommit operation failed due to IPC error." "Unable to check the firmware version on Standby CP due to IPC error." "Unable to restore the original firmware due to Standby CP timeout." "Standby CP failed to reboot and was not responding - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 818
started to restore the secondary partition." 0x93 "firmwareCommit failed." 0x94 "The secondary partition has been restored successfully." 0x95 "Firmware is being downloaded to the blade. This step may take up to 10 minutes." 0xa0 "firmwareDownload timed out." 0xa1 "Reboot occurred during - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 819
The RPM package database is inconsistent. Contact your service provider for recovery." 0x13 "Out of memory." 0x14 "Failed to download RPM package." 0x15 "Unable to create firmware version file." 0x16 "Unexpected system error." 0x17 "Error in getting lock device for firmwareDownload." 0x18 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 820
of some common error messages: 0x15 - Failed to download Red Hat package manager (RPM) package. If this error occurs immediately after firmwareDownload is started, the firmware on the switch may be two releases older than the requested firmware. firmwareDownload supports firmware upgrades within two - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 821
cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server. It may also be caused by - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 822
single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator's Guide for troubleshooting information. Severity INFO SULB-1010 Message - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 823
blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. Severity ERROR SULB-1021 Message AUDIT, , [SULB-1021], WARNING, FIRMWARE, , , , Firmware is being downloaded to the blade in slot - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 824
, the blade firmware version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity WARNING - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 825
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure the switch is enabled. Severity WARNING SULB-1034 Message Probable Cause AUDIT, , [SULB-1034], ERROR, FIRMWARE, , , Relocation of - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 826
. Recommended Reset the switch. This will cause the internal image to be relocated again. If the problem persists, Action contact your switch service provider. Severity ERROR SULB-1037 Message AUDIT, , [SULB-1037], ERROR, FIRMWARE, HCL failed. Reboot the switch manually using the - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 827
Run the firmwareShow command to verify the firmware versions. Run the firmwareDownload command again if the firmware is not updated. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider. Severity WARNING Fabric OS Message Reference - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 828
128 SULB-1040 752 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 829
-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended No action is required. Action Severity - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 830
129 SWCH-1014 754 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 831
[UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action is required - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 832
INFO, CFG, , , , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended No action - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 833
Severity INFO 130 UCST-1027 Fabric OS Message Reference 757 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 834
130 UCST-1027 758 Fabric OS Message Reference 53-1001767-01 - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 835
AUDIT ZONE System Messages Chapter 131 ZONE-3001 Message AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \" - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 836
131 ZONE-3004 The zone object type can be "alias", "zone member", "zone" or "zone configuration". The string "..." appears at the end of the zone object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 837
-details>, , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates the specified zone configuration has been enabled. Recommended Verify the event was planned. If the event was planned, no action is - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 838
131 ZONE-3011 Severity INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged. Probable Cause Indicates the specified zone object has been expunged - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 839
131 ZONE-3015 An AD object set type is "AD member". The string "..." appears at the end of the AD object member list if the list was truncated in the message. Recommended Verify the event was planned. If the event was planned, no action is required. If the event was not Action planned, take - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 840
131 ZONE-3018 ZONE-3018 Message AUDIT, , [ZONE-3018], INFO, FABRIC, , , , Event: , Status: success, Info: has been deactivated. Probable Cause Indicates the specified admin domain (AD) object has been deactivated. - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 841
131 ZONE-3022 Severity INFO ZONE-3022 Message AUDIT, , [ZONE-3022], INFO, FABRIC, , , , Event: , Status: success, Info: Current AD configuration saved to flash. Probable Cause Indicates the current admin domain (AD) configuration - HP 8/8 | Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 842
131 ZONE-3025 Severity INFO 766 Fabric OS Message Reference 53-1001767-01
53-1001767-01
30 March 2010
®
Fabric OS
Message Reference
Supporting Fabric OS v6.4.0