HP 8000f Maintenance and Service Guide: HP Compaq 8000f Elite Business PC Ultr - Page 162

Specifications, Desktop Dimensions, Approximate Weight, Weight Supported, Temperature Range

Page 162 highlights

I Specifications Table I-1 Specifications Desktop Dimensions (in the desktop position) Height 2.60 in 6.6 cm Width 9.90 in 25.1 cm Depth 10.00 in 25.4 cm (depth will increase if the computer is equipped with a port security bracket) Approximate Weight 6.75 lb 3.07 kg Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg Temperature Range (values subject to change with increasing altitude above sea level) Operating 50° to 95° F Nonoperating -22° to 140° F 10° to 35° C -30° to 60° C NOTE: Operating temperature is derated 1.0° C per 300 m (1,000 ft) to 3,000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10° C (50° F)/Hr. The upper limit may be limited by the type and number of options installed. Relative Humidity (noncondensing) Operating (28° C (82.4° F) max wet bulb) 10-90% 10-90% Nonoperating (38.7° C (101.66° F) max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3,048 m Nonoperating 30,000 ft 9,144 m Heat Dissipation Maximum 549 BTU/hr 132 kg-cal/hr Typical (idle) 133 BTU/hr 33.5 kg-cal/hr Power Supply Operating Voltage Range 90-264 VAC Rated Voltage Range1 100-240 VAC Rated Line Frequency 50-60 Hz Power Output 135 W 152 Appendix I Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

I
Specifications
Table I-1
Specifications
Desktop Dimensions
(in the desktop position)
Height
Width
Depth
(depth will increase if the computer is equipped with a port security bracket)
2.60 in
9.90 in
10.00 in
6.6 cm
25.1 cm
25.4 cm
Approximate Weight
6.75 lb
3.07 kg
Weight Supported
(maximum distributed load in desktop position)
77 lb
35 kg
Temperature Range
(values subject to change with increasing altitude above sea
level)
Operating
Nonoperating
50° to 95° F
-22° to 140° F
10° to 35° C
-30° to 60° C
NOTE:
Operating temperature is derated 1.0° C per 300 m (1,000 ft) to 3,000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10° C (50° F)/Hr. The upper limit may be limited by the type and number of
options installed.
Relative Humidity
(noncondensing)
Operating (28° C (82.4° F) max wet bulb)
Nonoperating (38.7° C (101.66° F) max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude
(unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3,048 m
9,144 m
Heat Dissipation
Maximum
Typical (idle)
549 BTU/hr
133 BTU/hr
132 kg-cal/hr
33.5 kg-cal/hr
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
Power Output
135 W
152
Appendix I
Specifications