HP BL2x220c HP ProLiant BL2x220c Generation 5 Server Blade User Guide
HP BL2x220c - ProLiant - G5 Server A Manual
View all HP BL2x220c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP BL2x220c manual content summary:
- HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 1
HP ProLiant BL2x220c Generation 5 Server Blade User Guide Part Number 468227-001 March 2008 (First Edition) - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 2
of Advanced Micro Devices, Audience assumptions This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 3
Setup...17 Overview ...17 Installing an HP BladeSystem c-Class enclosure 17 Installing server blade options ...17 Installing interconnect modules ...17 Interconnect bay numbering and device mapping 18 Connecting to the network...19 Installing a server blade ...19 Completing the configuration...20 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 4
the server for diagnosis...58 Service notifications...59 Loose connections ...59 Troubleshooting flowcharts ...59 Start diagnosis flowchart...60 General diagnosis flowchart...61 Server blade power-on problems flowchart 63 POST problems flowchart ...65 OS boot problems flowchart...67 Server fault - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 5
) ...75 European Union regulatory notice ...75 Disposal of waste equipment by users in private households in the European Union 75 Japanese notice ...76 BSMI Specifications ...80 Environmental specifications...80 Server blade specifications...80 Technical support...81 Before you contact HP ...81 HP - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 6
B Power On/Standby button Server B serial label pull tab Server B HP c-Class Blade SUV Cable connector* Server blade handle Server A HP c-Class Blade SUV Cable connector* Server A serial label pull tab Server A Power On/Standby button * The SUV connector and the HP c-Class Blade SUV Cable are for - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 7
Front panel LEDs Item 1 2 3 4 5 6 7 Description Server B system power LED Server B UID LED Server B health LED Server B NIC link and activity LED* Server A NIC link and activity LED* Server A health LED Server A UID LED Status Green = On Amber = Standby (auxiliary power available) Off = No power - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 8
* Actual NIC numbers depend on several factors, including the operating system installed on the server blade. System board components Server A system board components Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Internal USB connector Hard drive connector Processor socket 1 (populated) Processor - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 9
Item 1 2 3 4 5 6 7 8 9 Description Hard drive connector Processor socket 2 Processor socket 1 (populated) System maintenance switch System battery Signal connector Server B serial number label DIMM slots Internal USB connector DIMM slot numbering For installation guidelines and population order - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 10
DIMM slots Mezzanine connector definitions Item PCIe support Server support Mezzanine connector 1 x8, Type I mezzanine card only Server A only Mezzanine connector 2 x8, Type 1 mezzanine card only Server B only A PCIe x8 mezzanine connector supports x16 cards at up to x8 speeds. Component - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 11
Position 1 2 3 4 5 6 7 8 Function iLO 2 security override Configuration lock Reserved Reserved Password disabled Reset CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur. Access components CAUTION: The jackscrews control the - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 12
HP c-Class Blade SUV Cable Item 1 2 3 4 Connector Server blade Video USB Serial Description For connecting to the SUV connector on the server blade front panel For connecting a video monitor For connecting up to two USB devices For trained personnel to connect a null modem serial cable and - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 13
, see the enclosure setup and installation guide on the HP website (http://www.hp.com/support). For more information about iLO 2, see "Integrated Lights-Out 2 technology (on page 48)." Power down the server blade Before powering down the server blade for any upgrade or maintenance procedures - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 14
by observing that the system power LEDs are amber. Remove the server blade To remove the component: 1. Identify the proper server blade. 2. Power down the server blade (on page 13). 3. Remove the server blade. 4. Place the server blade on a flat, level work surface. WARNING: To reduce the risk of - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 15
Turn jackscrew 1 counterclockwise until the threads are fully disengaged. CAUTION: To prevent damage to the server blade, do not apply pressure to the enclosure connector. 8. Lift server B assembly from server A assembly, and then place it on the work surface with the system board facing up. Install - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 16
CAUTION: The jackscrews control the unseating and seating of critical system connectors. Failure to use the jackscrews to remove and install the server B assembly can cause the system boards to fail. 5. Engage the threads on jackscrew 1 and tighten six turns clockwise. 6. Engage the threads on - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 17
Install a server blade. 6. Complete the server blade configuration. Installing an HP BladeSystem c-Class enclosure Before performing any server blade-specific procedures, install an HP BladeSystem c-Class enclosure. The most current documentation for server blades and other HP BladeSystem components - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 18
and device mapping • HP BladeSystem c7000 Enclosure • HP BladeSystem c3000 Enclosure To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals. Server blade signal Server A NIC 1 (Embedded) Server A NIC - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 19
) Server B mezzanine c7000 interconnect bay 4 7 and 8 c3000 interconnect bay 2 3 and 4 Interconnect bay labels For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the HP BladeSystem enclosure setup and installation guide on the HP website (http://www.hp - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 20
2. Remove the enclosure connector cover. 3. Install the server blade. Completing the configuration To complete the server blade and HP BladeSystem configuration, see the overview card that ships with the enclosure. Setup 20 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 21
instructions server supports one internal SATA drive. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To install the component: 1. Power down the server blade (on page 13). 2. Remove the server blade - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 22
5. Remove the four screws from the hard drive carrier. 6. Install the hard drive in the carrier. Hardware options installation 22 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 23
to Advanced ECC Support. For more information, refer to "HP ROM-Based Setup Utility (on page 45)." For DIMM slot locations and bank assignments, see "DIMM slot numbering (on page 9)." Advanced ECC memory Advanced ECC memory is the default memory protection mode for this server blade. In Advanced ECC - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 24
Each server supports multiple memory modes, based on DIMM population. The system will default to Advanced ECC. To select a mode, use RBSU ("HP ROM-Based Setup Utility" on page 45). Installing DIMMs To install the component: 1. Power down the server blade (on page 13). 2. Remove the server blade (on - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 25
"Interconnect bay numbering and device mapping (on page 18)" and the HP ProLiant BL2x220c Generation 5 Server Blade Installation Instructions that ship with the server blade. To install the component: 1. Power down the server blade (on page 13). 2. Remove the server blade (on page 14). 3. Access the - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 26
19). Cache module battery option To install the component: 1. Power down the server blade (on page 13). 2. Remove the server blade (on page 14). 3. Access the internal server components (on page 14). 4. Remove the server A USB key, if installed. 5. Remove the hard drive carrier. Retain the component - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 27
7. Install the upper cache battery in the battery tray. 8. Connect the cables to the battery packs. Hardware options installation 27 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 28
it does not become pinched when the system board is installed. o If a processor and heatsink are installed in processor socket 2, then remove the server A system board assembly, route the cables between the heatsink and the system board, and install the system board assembly. 11. Install the cable - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 29
the lower mezzanine card. The cables must lie flat between the mezzanine card and the system board. For more information, see the installation instructions that ship with the mezzanine cards. 16. Connect the cable from the lower battery to the lower cache module. 17. Install the upper mezzanine - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 30
cache module battery cables so that they do not become pinched when the server B assembly is installed. 22. Install the server B assembly ("Install server B assembly" on page 15). 23. Install the server blade ("Installing a server blade" on page 19). Processor option WARNING: To reduce the risk of - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 31
. IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in the heatsink. IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty, the server blade does not power up. IMPORTANT: If upgrading processor - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 32
5. Open the processor retaining latch and the processor socket retaining bracket. 6. Remove the processor socket protective cover. IMPORTANT: Be sure the processor remains inside the processor installation tool. Hardware options installation 32 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 33
7. If the processor has separated from the installation tool, carefully re-insert the processor in the tool. 8. Align the processor installation tool with the socket and install the processor. Hardware options installation 33 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 34
9. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool. 10. Close the processor socket retaining bracket and the processor retaining latch. Hardware options installation 34 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 35
"X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes server B assembly is installed. 13. Install the server B assembly ("Install server B assembly" on page 15). 14. Install the server blade ("Installing a server blade - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 36
Cabling Using the HP c-Class Blade SUV Cable The HP c-Class Blade SUV Cable enables the user to perform server blade administration, configuration, and diagnostic procedures by connecting video and USB devices directly to the server blade. For SUV cable connectors, see "HP c-Class Blade SUV Cable ( - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 37
4. Connect a USB keyboard to the second USB connector. Item 1 2 3 4 5 6 Description Monitor USB mouse HP c-Class Blade SUV Cable Server blade Video connector USB keyboard Accessing a server blade with local media devices Use a USB hub when connecting a USB diskette drive and/or USB CD-ROM drive - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 38
o USB diskette Item 1 2 3 4 5 6 7 Description Monitor USB mouse HP c-Class Blade SUV Cable Server blade USB hub USB keyboard USB CD/DVD-ROM drive or diskette drive BBWC battery cabling Cabling 38 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 39
server blades: • Health and Wellness driver and IML viewer • iLO 2 Management interface driver • Rack infrastructure interface service For Microsoft® Windows® OS users, these items are included in the HP ProLiant iLO 2 Standard Blade Edition, available from the HP website (http://www.hp.com/servers - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 40
server blade. The c-Class tab enables you to control specific settings for the HP BladeSystem. iLO 2 also provides webbased status for the HP BladeSystem configuration. For detailed information about iLO 2, refer to the HP Integrated Lights-Out User Guide on the HP website (http://www.hp.com/servers - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 41
(Windows® or Linux deployment) o Windows® 2000 or Windows Server™ 2003 OS installed o Network connection o CD-ROM drive o 1.5 GB of available disk space o TCP/IP networking and an IP address compatible with one of the following: the iLO 2 Diagnostic Port IP address or an assigned DHCP or static IP - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 42
Deployment Solution and the HP ProLiant Integration Module. The intuitive graphical user interface of the Altiris Deployment Solution console provides simplified pointand-click and drag-and-drop operations that enable you to deploy target servers, including server blades, remotely. It enables you - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 43
Copy the image of the boot CD to a location on the network or the client PC hard drive. 2. Remotely access the server blade through iLO 2. Refer to "HP BladeSystem c-Class advanced management (on page 39)." 3. Click the Virtual Devices tab. 4. Select Virtual Media. 5. Use the Virtual Media applet to - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 44
user creates a DOS-based network-enabled boot diskette that executes a script that configures the hardware and installs the OS. The diskette enables the server blade PC hard drive. 2. Remotely access the server blade through iLO 2. Refer to "HP BladeSystem c-Class advanced management (on page 39)." - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 45
server blade enclosure management module firmware is up-to-date. Refer to the HP Business Support Center website (http://www.hp.com/support). • The server blade is cabled properly to a supported SAN. • SAN storage drivers are loaded. Refer to supporting white papers and the HP website (http://www.hp - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 46
memory options • Language selection For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/support on the number of drives connected to the server. NOTE: The server may not support all the following examples. NOTE: If - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 47
connection to the server COM port. The server that you are remotely configuring does not require a keyboard and mouse. For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the Documentation CD or the HP website (http://www.hp.com/support/smartstart/documentation - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 48
firmware revisions. For more information about the ROMPaq utility, see the HP website (http://www.hp.com/go/support). Integrated Lights-Out 2 technology The iLO 2 subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 49
loads new drivers, required for boot, on the destination server. The wizard-based user interface simplifies the migration process and requires little experience or training. For more information about the SMP - P2P, see the HP website (http://www.hp.com/go/p2p). HP ProLiant Essentials Performance - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 50
For more information, see the HP ProLiant Essentials Vulnerability and Patch Management Pack User Guide, or the HP website (http://www.hp.com). HP Insight Control Environment Suites HP Insight Control Environment and Insight Control Environment for BladeSystem are integrated suites of software that - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 51
in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server blade installations, troubleshoot problems, and perform repair validation. HP Insight Diagnostics Offline Edition performs various in-depth system and - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 52
it can be installed through the HP PSP ("ProLiant Support Packs" on page 54). NOTE: The current version of SmartStart provides the memory spare part numbers for the server blade. To download the latest version, see the HP website (http://www.hp.com/support). Integrated Management Log The IML records - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 53
generates a sequence of descending audible beeps. Repeat the disaster recovery process. 6. Power down the server blade (on page 13). 7. Remove the ROMPaq diskette. 8. Power up the server blade. Manual ROMPaq disaster recovery 1. Create a ROMPaq diskette using the Autorun Menu on the SmartStart CD - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 54
, and installs only the correct ROM upgrades required by each target server For more information, see the HP Smart Update Manager User Guide. The guide and the HP Smart Update Manager utility are available from the ProLiant Firmware Maintenance CD. This CD and others can be downloaded free - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 55
tools • Automatically checks for hardware, firmware, and operating system dependencies, and installs only the correct ROM upgrades required by each target server To download the tool and for more information, see the HP website (http://www.hp.com/support). Change control and proactive notification - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 56
maintenance on ProLiant servers and server blades. This guide includes problemspecific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a language: • English (http://www.hp.com/support/ProLiant_TSG_en) • French (http://www.hp.com/support/ProLiant_TSG_fr - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 57
troubleshooting the server. Important safety information Before servicing this product, read the Important Safety Information document provided with the server The area contains no user or field serviceable parts. Do not safety requirements and guidelines for manual material handling. These symbols, - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 58
for any reason. Symptom information Before troubleshooting a server problem, collect the following information: • What server exhibited problem symptoms? • If the problem occurs randomly, what is the duration or frequency? To answer these questions, the following information may be useful: • Run HP - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 59
for server-specific information. o HP recommends you have access to the SmartStart CD for value-added software and drivers required during the troubleshooting process. NOTE: Download the current version of SmartStart from the HP website (http://www.hp.com/servers/smartstart). Service notifications - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 60
1 2 3 4 5 Refer to "General diagnosis flowchart (on page 61)" "Power-on problems flowchart ("Server blade power-on problems flowchart" on page 63)" "POST problems flowchart (on page 65)" "OS boot problems flowchart (on page 67)" "Server fault indications flowchart (on page 69)" Troubleshooting 60 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 61
flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart. Item 1 2 3 See "Symptom information (on page 58)" "Loose connections (on page 59)" "Service notifications (on page 59 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 62
and service guides for c-Class server blades, located on the Documentation CD or the HP website (http://www.hp.com/go/bladesystem/documentation) • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 63
Server blade power-on problems flowchart Symptoms: • The server does not power on. • The system power LED is off or amber. Troubleshooting 63 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 64
1 2 3 See "Component identification (on page 6)" Maintenance and service guides for c-Class server blades, located on the HP website (http://www.hp.com/go/bladesystem/documentation) Integrated Lights-Out User Guide located on the HP website (http://www.hp.com/servers/lights-out) Troubleshooting 64 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 65
Symptoms: • Server does not complete POST NOTE: The server has completed POST when the system attempts to access the boot device. • Server completes POST with errors Possible problems: • Improperly seated or faulty internal component • Faulty KVM device • Faulty video device Troubleshooting 65 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 66
problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • Maintenance and service guides for c-Class server blades, located on the Documentation CD or the HP website (http://www.hp.com/go/bladesystem/documentation - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 67
a server blade: • Use iLO to attach virtual devices remotely to mount the SmartStart CD on the server blade. • Use an HP c-Class Blade SUV Cable and drive to connect to the server blade, and then restart the server blade. Symptoms: • Server does not boot a previously installed OS Troubleshooting 67 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 68
HP website (http://www.hp.com/support) • "HP contact information (on page 81)" 8 • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • Maintenance and service guides for p-Class server blades - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 69
the server blade OS boot problems flowchart (on page 67) Server fault indications flowchart Symptoms: • Server boots, but a fault event is reported by Insight Management Agents • Server boots, but the internal health LED, external health LED, or component health LED is red or amber Troubleshooting - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 70
://www.hp.com/support) • Maintenance and service guides for c-Class server blades, located on the Documentation CD or the HP website (http://www.hp.com/go/bladesystem/documentation) • "HP contact information (on page 81)" • "Hardware problems" in the HP ProLiant Servers Troubleshooting Guide located - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 71
a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support). WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 72
both server A and server B when either battery is replaced. If the server blade no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years. WARNING: The computer contains - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 73
to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. FCC rating label The FCC rating label on the device - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 74
in accordance with the instructions, may cause harmful Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections to - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 75
(used only if applicable-refer to the product label) Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany Disposal of waste equipment by users in private households in the European Union Regulatory compliance notices 75 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 76
environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Japanese notice BSMI notice Regulatory compliance notices 76 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 77
herein or in the laser product's installation guide may result in hazardous radiation exposure. To to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, those specified herein. • Allow only HP Authorized Service technicians to repair the unit. The - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 78
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Taiwan battery - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 79
. This type of damage may reduce the life expectancy of the device. To prevent electrostatic by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a mats. • Use conductive field service tools. • Use a portable field service kit with a folding static- - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 80
humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. Server blade specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 5.56 cm (2.19 in) 50.95 cm (20.06 in) 18.16 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 81
reseller: • In the United States, see the HP US service locator webpage (http://www.hp.com/service_locator). • In other locations, see the Contact HP worldwide (in English) webpage (http://welcome.hp.com/country/us/en/wwcontact.html). For HP technical support: • In the United States, for contact - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 82
required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. • Facultatif - - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 83
lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. • Optional - Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen Technical support 83 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 84
Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des Kunden zu erfüllen, muss das Teil von einem HP können Sie das HP technische Support Center anrufen und - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 85
de HP, pó HP siguiente (http://www.hp.com/go/selfrepair). Customer Self Repair Veel onderdelen in HP HP HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.nl/services/servicepartners). Reparo feito pelo cliente Os produtos da HP HP (ou fornecedores/parceiros de serviço da HP) - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 86
entanto, se desejar que a HP as substitua, pode haver ou HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP HP para que um técnico o ajude por telefone. A HP especifica HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 87
Technical support 87 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 88
Technical support 88 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 89
Acronyms and abbreviations ABEND abnormal end ASR Automatic Server Recovery BBWC battery-backed write cache CSR Customer Self Repair DHCP Dynamic Host Configuration Protocol FC Fibre Channel iLO 2 Integrated Lights-Out 2 IML Integrated Management Log NBP Network Bootstrap Program ORCA Option ROM - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 90
RBSU ROM-Based Setup Utility SATA serial ATA SIM Systems Insight Manager UID unit identification USB universal serial bus VCA Version Control Agent Acronyms and abbreviations 90 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 91
, overview 49 HP technical support 81 I identification number 73 iLO 2 (Integrated Lights-Out 2) 39, 48 iLO 2 activity LED 48 IML (Integrated Management Log) 52 Important Safety Information document 57 Insight Diagnostics 51, 52, 54 installation, server blade 17 installation, server options 21 - HP BL2x220c | HP ProLiant BL2x220c Generation 5 Server Blade User Guide - Page 92
up 46 power-on problems flowchart 63 preparation procedures 58 problem diagnosis 56 processor 30 ProLiant Support Pack (PSP) 54 PSPs, overview 54 R RBSU (ROM-Based Setup Utility) 45 RBSU configuration 46 regulatory compliance notices 73, 75 removing the server blade 14 required information 81
HP ProLiant BL2x220c Generation 5 Server
Blade
User Guide
Part Number 468227-001
March 2008 (First Edition)