HP BL2x220c Integrating HP Insight Management WBEM Providers with HP System In
HP BL2x220c - ProLiant - G5 Server A Manual
View all HP BL2x220c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP BL2x220c manual content summary:
- HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 1
install and configure HP Insight Management WBEM Providers on a managed node ..... 16 Configure and identify existing HP Insight Management WBEM Providers through HP SIM 18 Setting configurable disk thresholds in SIM 20 Identifying issues with hardware components 21 SIM Indication support for HP - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 2
management infrastructure provided by the Insight Providers can be accessed using the System Management Homepage (SMH), which is in the ProLiant Support Packs (PSPs). In addition, users can configure HP Systems Insight Manager (HP SIM) version 5.2 and later to leverage Insight Providers for Windows - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 3
30 minutes to get updates. • The System Box includes the following modifications : - Cooling and Power page has two main improvements. The page is capable of showing empty fan slots. Previously, this page only showed installed fans. For example, if there is no "Fan 4," the page notes that there is - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 4
same time they install Insight Providers for HP SIM HP SIM 5.2 and the HP problems. • WBEM consolidated status (an indicator of overall server health) as a component of Health Status. • A link to the WBEM-based System Management Homepage. • A variety of reports that include inventory and configuration - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 5
and the Insight Providers for Windows integration WBEM indications HP SIM can subscribe for and receive WBEM indications (asynchronous alerts that provide SIM users a real-time status for hardware components that are experiencing problems). Figures 2 and 3 provide an example of how WBEM indications - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 6
Figure 2. Subscribing for WBEM indications using the HP SIM user interface 6 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 7
Figure 3. Subscribing for WBEM indications using the HP SIM CLI, and a list of existing subscriptions Figure 4 displays a WBEM indication report. Figure 4. WBEM indication report 7 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 8
. HP SIM will receive indications (if subscribed) when the thresholds are exceeded. Note Disk and processor thresholds cannot be received in HP SIM 5.2 This feature will be functional in HP SIM 5.3. Figure 5 shows the window that allows users to set thresholds. Figure 5. Disk threshold configuration - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 9
through various levels of status to the offending instance of hardware. HP SIM Status Polling collects an overall status value from Insight Providers for follow-the-red" can be used starting at HP SIM Health Status and tracing through the System Management Homepage. Figure 6. Following a status to the - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 10
WBEM Provider deployment and configuration HP SIM provides a convenient deployment tool for HP Insight Management WBEM Providers. The HP SIM Configure or Repair Agents (CRA) tool, found under the Configure menu, allows a user to push the HP Insight Management WBEM Providers to the managed node as - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 11
Figure 8. Installing Providers on a Windows server - configure or repair settings Hardware and software inventory HP SIM provides a comprehensive inventory of hardware and software on the managed node, including reports for specific platforms. The user may select from a variety of inventory items to - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 12
Figure 9. Configuring inventory reports Figure 10. Default Inventory Report for Windows Server running HP Insight WBEM Providers for Windows 12 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 13
Property pages HP SIM Property pages (Figure 11) display overall server characteristics, status information, and configuration/inventory data. The Property page data, read and reported in real time, is exclusively WBEM data. Figure 11. Property page examples 13 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 14
is available in the "HP Systems Insight Manager 5.2 Installation and Configuration Guide for Microsoft Windows": http://h18013.www1.hp.com/products/servers/management/hpsim/infolibrary.html#b2. Installing WMI Mapper on a different server than where HP SIM is installed requires these steps: • Move - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 15
Figure 12. Mapper service Figure 13 shows the screen in HP SIM used to configure the Mapper. Figure 13. WMI Mapper Proxy configuration 15 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 16
Using HP SIM to install and configure HP Insight Management WBEM Providers on a managed node 1. Make sure the WMI Mapper is configured in HP SIM. For more information, see Configuring the WMI Mapper in HP SIM. 2. Identify ProLiant servers through HP SIM. See the HP SIM Technical Reference Guide for - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 17
or more managed nodes. Figure 15 shows the window in which Providers and agents should be installed. Figure 15. Configure or Repair Agents - Install Providers and Agents window 5. Configure a non-Administrator user. 6. Subscribe to WBEM events. 7. Trigger a test indication to confirm the WBEM event - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 18
, and then populate the WBEM credentials table. 4. Discover ProLiant Windows servers that have the HP Insight Management WBEM Providers installed. 5. Once discovered, the ProLiant Windows servers display in the HP SIM All Systems list. 6. Access the System page and confirm that WBEM is a discovered - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 19
Figure 17. System Protocol Settings link 8. Enter the WBEM credentials. Figure 18 shows the system protocol settings window. Figure 18. System Protocol Settings window 9. Re-identify the ProLiant Windows server at Options- > Identify Systems. 19 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 20
the WMI Mapper is configured in HP SIM. For more information, see Configuring the WMI Mapper in HP SIM. 2. Access SMH through HP SIM using the Health Status link on the Systems page (Figure 19). Figure 19. System Status window 3. Click Tasks. 4. Select Server Configuration. 5. In left panel, select - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 21
that have potential problems. The following example illustrates a Major status in HP SIM. Figure 21 shows the location of the Health Status link. Selecting the Health Status link launches the SMH. SMH then shows the Major status is traceable to the Network components, specifically the NC371i Adapter - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 22
Figure 21. Health Status link 22 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 23
Figure 22 shows the System Management Homepage. Figure 22. System Management Homepage (SMH) - Major status component 23 - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 24
SIM Indication support for HP Insight Management WBEM Providers 1. Make sure the WMI Mapper is configured in HP SIM. For more information, see Configuring the WMI Mapper in HP SIM. 2. Create a subscription in the user interface by clicking Options > Events > Subscribe to WBEM Events. The user does - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 25
2. Open an event to get more details. Figure 24. Indications in the Events tab Troubleshooting WBEM Indications in HP SIM If a subscription fails: 1. Make sure WBEM is a discovered protocol on the managed node (Systems Page > Product Description table > Management Protocols). 2. Make sure the node - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 26
Providers for Windows test event tool. 4. Make sure the WMI Mapper Indication Service is running. 5. Try to list the known subscriptions: - Mxwbemsub -l -n management protocol: 1. Access the Systems page (the page that contains an overview of the selected server). 2. In the Product Description - HP BL2x220c | Integrating HP Insight Management WBEM Providers with HP System In - Page 27
ProLiant Server Support Matrix website HP software and drivers Access to WMI Namespaces Connecting to WMI on a Remote Computer PSP website HP Systems Insight Manager Web address http://h10018.www1.hp.com/wwsolutions/windows/ index-all.html http://welcome.hp.com/country/us/en/support.html
Integrating HP Insight Management WBEM
Providers with HP System Insight Manager
integration note, 2
nd
edition
Abstract
..............................................................................................................................................
2
Overview
............................................................................................................................................
2
Updates to the System Management Homepage (SMH)
............................................................................
2
Security
..............................................................................................................................................
3
Insight Provider deployment and SNMP agent removal
............................................................................
4
Integration with HP SIM
........................................................................................................................
4
Identification
....................................................................................................................................
4
Systems page
..................................................................................................................................
4
WBEM indications
...........................................................................................................................
5
Disk thresholds
.................................................................................................................................
8
Status polling
...................................................................................................................................
9
WBEM Provider deployment and configuration
.................................................................................
10
Hardware and software inventory
....................................................................................................
11
Property pages
..............................................................................................................................
13
Scenarios using HP Insight WBEM Providers
.........................................................................................
14
Configuring the WMI Mapper in HP SIM
..........................................................................................
14
Using HP SIM to install and configure HP Insight Management WBEM Providers on a managed node
.....
16
Configure and identify existing HP Insight Management WBEM Providers through HP SIM
.....................
18
Setting configurable disk thresholds in SIM
........................................................................................
20
Identifying issues with hardware components
....................................................................................
21
SIM Indication support for HP Insight Management WBEM Providers
...................................................
24
Confirming WBEM is identified as a management protocol
.................................................................
26
For more information
..........................................................................................................................
27
Call to action
....................................................................................................................................