- HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 1
HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service Guide Part Number 452659-003 April 2009 (Third Edition) - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 2
Intel Corporation or its subsidiaries in the United States and other countries. Intended audience This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 3
Server blade handle ...31 Release button ...31 Heatsink...32 Processor ...33 System battery ...36 System board ...37 Diagnostic tools ...43 HP Insight Diagnostics...43 HP Insight Diagnostics survey functionality 43 Integrated Management Log ...43 Array Diagnostic Utility ...44 Redundant ROM support - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 4
System maintenance switch...49 System maintenance switch procedures 50 HP c-Class Blade SUV Cable...51 Specifications ...52 Environmental specifications ...52 Server blade specifications ...52 Acronyms and abbreviations...53 Index...57 Contents 4 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 6
téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie " - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 7
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten . Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center Customer self repair 7 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 8
CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 9
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 10
voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 11
peças. Segundo os termos do serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar nenhuma taxa. No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 12
Customer self repair 12 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 13
Customer self repair 13 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 14
Customer self repair 14 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 15
Customer self repair 15 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 16
Illustrated parts catalog Server blade components Item Description 1 Heatsink 2 Processor a) 1.60-GHz Intel® Xeon™ processor E7310, 2x2MB cache, 1066-MHz FSB** b) 1.86-GHz Intel® Xeon™ processor L7345, 2x4MB cache, 1066- - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 17
1333-MHz FSB* ** h) 2.4-GHz Intel® Xeon™ processor E7440, 16MB L3 cache, 490065-001 1333-MHz FSB* ** power, PC2-5300 FBDIMM* 462837-001 f) 2-GB, low power, PC2-5300 FBDIMM* 455442-001 g) 4-GB, low power, PC2-5300 FBDIMM* 467654-001 4 System board 5 Hard drive backplane* 6 HP Smart Array - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 18
-c Adapter 466309-001 j) HP NC532m Dual Port Flex-10 10 GbE Multifunction BL-c Adapter 15 Handle kit* a) Server blade handle 466308-001 434104-001 - b) Release button - c) Server blade handle screw, T-15 - d) Release button screws, T-15 (2) - 3) Server blade handle nut - 16 Miscellaneous - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 19
be identical. Two or four processors are supported per server, one and three are not. 1Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which customer self - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 20
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 21
service procedures, review all the safety information. Preventing electrostatic discharge To prevent damaging the system, drives and the internal system components to cool before touching them. CAUTION: Do not operate the server blade with the access panel removed. Operating the server blade - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 22
: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system. Server blade preparation To service any internal server blade component, power down the server blade and remove it from the enclosure. Removal and replacement procedures 22 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 23
the server blade, remove the server blade from the enclosure. After initiating a virtual power down command, be sure that the server blade go into standby mode by observing that the system power LED is amber. Remove the server blade 1. Identify the proper server blade. 2. Power down the server blade - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 24
reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 25
or replacing FBDIMMs. FBDIMM baffles that are missing or installed incorrectly can compromise server blade and enclosure cooling. To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 26
the component, reverse the removal procedure. Hard drive 1. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("SAS and SATA hard drive LED combinations" on page 47). 2. Back up all server data. 3. Remove the hard drive. To replace the component, reverse the - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 27
cards enable network connectivity and provide Fibre Channel support. For mezzanine card locations, see the system board components (on page 48) . To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 28
to the edges of the card. To replace the component, reverse the removal procedure. HP Smart Array P400i Controller battery pack To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 29
P400i Controller cache module To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24). 4. Remove the battery pack ("HP Smart Array P400i Controller battery pack" on page 28). 5. Remove the - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 30
the removal procedure. Front panel/hard drive cage assembly To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24). 4. Remove all hard drives ("Hard drive" on page 26). 5. Remove all hard - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 31
the component, reverse the removal procedure. Server blade handle To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24). 4. Remove all hard drives ("Hard drive" on page 26). 5. Remove all - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 32
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 33
the heatsink. 4. Install the access panel ("Access panel" on page 24). Processor WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. Removal and replacement procedures 33 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 34
IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty, the server blade does not power up. To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 23). 3. Remove the access panel ("Access panel" on page 24). 4. Remove - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 35
6. Remove the processor. To replace the component: 1. Install the processor. 2. Close the processor locking lever. 3. Clean the old thermal grease from the heatsink with the alcohol swab. Allow the alcohol to evaporate before continuing. Removal and replacement procedures 35 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 36
should be tightened in diagonally opposite pairs (in an "X" pattern). 5. Install the heatsink. 6. Install the access panel ("Access panel" on page 24). System battery If the server blade no longer automatically displays the correct date and time, you may need to replace the battery that provides - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 37
resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU. To replace the component, reverse the removal procedure. System board To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 38
4. Remove all hard drive blanks ("Hard drive blank" on page 26). 5. Remove the access panel ("Access panel" on page 24). 6. Remove the battery pack and cable, if applicable ("HP Smart Array P400i Controller battery pack" on page 28). 7. Remove all FBDIMM baffles ("FBDIMM baffles" on page 25). 8. - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 39
15. Remove the processor. 16. Remove the air baffle/access panel support. Removal and replacement procedures 39 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 40
. To replace the system board: 1. Install the spare system board in the server blade before installing the processor. 2. Open the processor locking lever on the spare system board. CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides on the processor and - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 41
the following patterns to ensure even distribution: 7. Install the heatsink. 8. Install the FBDIMMs. 9. Install the front panel/hard drive cage assembly. 10. Install the hard drive backplane. 11. Install the cache module. 12. Install the FBDIMM baffles. 13. Install the battery pack, if applicable - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 42
access panel. 17. Install the hard drive blanks. 18. Install the hard drives. 19. Install the server blade. IMPORTANT: Install all components with the same configuration that was used on the failed system board. 20. Power up the server blade. After you replace the system board, you must re-enter the - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 43
versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server blade installations, troubleshoot problems, and perform repair validation. HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 44
disk drives. This report provides vital information to assist in identifying faults or conditions that may require attention. ADU can be accessed from the SmartStart CD or downloaded from the HP website (http://www.hp.com). Redundant ROM support The server enables you to upgrade or configure the ROM - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 45
3 Serial pull tab 4 Server blade handle release button 5 Server blade handle 6 Hard drive bay 1 7 Hard drive bay 2 * The local I/O cable connector is used with the local I/O cable to perform some server blade configuration and diagnostic procedures. Server component identification 45 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 46
linked Green flashing = Network activity Off = No link or activity 7 System power LED Green = On Amber = Standby (auxiliary power available) Off = Off * Actual NIC numbers depend on several factors, including the operating system installed on the server blade. Server component identification 46 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 47
replace the drive until the expansion or migration is complete. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, erasing, or it is part of an array that is undergoing capacity expansion or stripe migration. Server component - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 48
for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. System board Type I mezzanine only) Enclosure connectors System board thumbscrews (3) Mezzanine connector 3 (Type I or Type II mezzanine) Server component identification 48 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 49
13 System battery The symbols correspond to the symbols located on the interconnect bays. For more information, see the HP ProLiant BL680c Generation 5 Server Blade Installation Instructions that ship with the server blade. Mezzanine connector definitions PCIe x8 mezzanine connectors support - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 50
troubleshooting steps, this guide may instruct you to perform the following procedures: • Clear the system configuration. • Access the redundant ROM. To complete these procedures, you must change physical settings on the system maintenance switch. Accessing the redundant ROM If the system ROM - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 51
HP c-Class Blade SUV Cable Item 1 2 3 4 Connector Server blade Video USB Serial Description For connecting to the SUV connector on the server blade front panel For connecting a video monitor For connecting up to two USB devices For trained personnel to connect a null modem serial cable and - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 52
°F) 10% to 90% 10% to 90% 10% to 95% * All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per maximum for storage corresponds to a pressure minimum of 70 kPa. Server blade specifications Specification Height Depth Width Weight (maximum) Value 36.60 cm - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 53
and abbreviations ABEND abnormal end ACU Array Configuration Utility ASR Automatic Server Recovery BBWC battery-backed write cache BIOS Basic Input/Output System CSR Customer Self Repair DDR2 double data rate-2 DHCP Dynamic Host Configuration Protocol ESD electrostatic discharge FBDIMM fully - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 54
Bootstrap Program NIC network interface controller ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager POST Power-On Self Test PSP ProLiant Support Pack PXE Preboot Execution Environment RAID redundant array of inexpensive (or independent) disks Acronyms and abbreviations - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 55
-Based Setup Utility RDP Rapid Deployment Pack ROM read-only memory SAS serial attached SCSI SATA serial ATA SCSI small computer system interface SFP small form-factor pluggable SIM Systems Insight Manager SNMP Simple Network Management Protocol TCP/IP Transmission Control Protocol/Internet Protocol - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 56
WEBES Web-Based Enterprise Service WfM Wired for Management Acronyms and abbreviations 56 - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 57
tools 43 memory 27 mezzanine card 27 mezzanine connectors 49 P powering down 23 preparation procedures 22 R removing the access panel 24 removing the server blade 23 ROM redundancy 44, 50 S safety considerations 21 safety information 21 SAS drives 47 SAS hard drive LEDs 47 SATA hard drive 47 Index - HP BL680c | HP ProLiant BL680c Generation 5 Server Blade Maintenance and Service - Page 58
SATA hard drive LEDs 47 serial connector 51 serial label pull tab 45 server blade handle 31, 45 specifications 52 static electricity 21 symbols on equipment 22 system board battery 36 system board components 48 system maintenance switch 49 U USB connectors 51 utilities 43 V video connector cabling
HP ProLiant BL680c Generation 5 Server Blade
Maintenance and Service Guide
Part Number 452659-003
April 2009 (Third Edition)