53-1002063-04 Fabric OS Documentation Updates 53-1002063-05 New document Added update for the Fabric OS Administrator's Guide. Added update for the FCIP Administrator's Guide Added updates for the Fabric OS Administrator's Guide, Fabric OS Command Reference, and CEE guides. Added updates for the - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 3
-1002063-09 Added updates for the Fabric OS Administrator's Guide, Fabric OS Command Reference, Brocade DCX Backbone Hardware Reference Manual, Brocade DCX-4S Backbone Hardware Reference Manual. September 2011 Added updates for the Fabric OS Command Reference December 2011 Added updates for the - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 4
iv Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 5
Chapter 3, Managing Policies and Features in Access Gateway Mode 1 Chapter 2 CEE Administrator's Guide In this chapter 3 Documentation updates for Fabric OS v6.4.0 3 Chapter 3, Standard CEE Integrations and Configurations. . . . . 3 Chapter 9, Configuring QoS using the CEE CLI 3 Documentation - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 6
47 Documentation updates for Fabric OS v6.4.0 and later 47 Chapter 1, Fabric Watch notification types 47 Chapter 2, Fabric Watch Thresholds 48 Chapter 4, Fabric Watch Activation 48 Fibre Channel over IP Administrator's Guide In this chapter 49 vi Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 7
v6.4.0 and v6.4.1 49 Appendix A, Fibre Channel Fast Write (FCFW 49 In this appendix 49 FC Fast Write (FCFW) concepts 50 Configuring and enabling FCFW 52 Disabling FCFW 53 Disabling FCFW flows without removing FCFW 54 Brocade DCX Backbone Hardware Reference Manual In this chapter 55 Chapter - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 8
viii Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 9
Fabric OS Encryption Administrator's Guide (RKM) Fabric OS Encryption Administrator's Guide (TEMS) Fabric OS Encryption Administrator's Guide (SKM) Fabric OS Encryption Administrator's Guide (TKLM) Fibre Channel over IP Administrator's Guide Fabric OS Message Reference Fabric OS Troubleshooting and - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 10
TABLE 1 Documentation Supporting Fabric OS 6.4.x Publication Title Fabric OS Release Page Number Web Tools Administrator's Guide DCX Backbone Hardware Reference Manual DCX-4S Backbone Hardware Reference Manual v6.4.0 and later v6.4.0 and later v6.4.0 and later No updates Updates on page 55 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 11
Document feedback Quality is our first concern at Brocade and we have made every effort to ensure topic needs further development, we want to hear from you. Forward your feedback to: [email protected] Provide the title and version number of the document and as much detail as possible about - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 12
xii Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 13
page 48, add the following note at the bottom of the page. NOTE N_Port Trunking is not supported for HBAs connected to switches running in Access Gateway mode. This feature is only be supported for HBAs connected to switches running in Native mode. Fabric OS Documentation Updates 1 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 14
1 Documentation updates for Fabric OS v6.4.1 and later 2 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 15
, and can consist of letters, digits, hyphens, and underscore characters. Spaces are prohibited. Special characters are not supported, and cause the name to truncate. Chapter 9, Configuring QoS using the CEE CLI Under the heading of "Creating a CEE map" on page 107, add the following note: NOTE The - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 16
example under step 3. Documentation updates for Fabric OS v6.4.1 Chapter 3, Standard CEE Integrations and Configurations Under the heading of "Creating the CEE map are not supported, and cause the name to truncate. Chapter 7, Configuring LLDP using the CEE CLI Under the heading of "Configuring the - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 17
Documentation updates for Fabric OS v6.4.1 2 Chapter 9, Configuring QoS using the CEE CLI Under the heading of " digits, hyphens, and underscore characters. Spaces are prohibited. Special characters are not supported, and cause the name to truncate. Under the heading of "Defining a priority - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 18
2 Documentation updates for Fabric OS v6.4.1 6 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 19
chapter are for the CEE Command Reference, published March 2010 and October 2010. • Documentation updates for Fabric OS v6.4.0 7 • Documentation updates for Fabric OS v6.4.1 7 Documentation updates for Fabric OS v6.4.0 USAGE GUIDELINES Revised commands in Fabric OS v6.4.0 Under the command cee - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 20
3 Documentation updates for Fabric OS v6.4.1 8 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 21
the Fabric OS Administrator's Guide, published September 2010. •Documentation updates for Fabric OS v6.4.0 and later 9 •Documentation Updates for Fabric OS v6.4.1 and later 12 Documentation updates for Fabric OS v6.4.0 and later Chapter 6, Configuring Protocols In the section "Installing a switch - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 22
FCR is supported on an edge switch only in Brocade Native Mode (interopmode 0). Chapter 14, Interoperability for Merged SANs In the section "Zoning restrictions" on page 306, add the following item: • The maximum zone database size is 1 MB and is a combination of the active configuration size and - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 23
license should be installed Local switch Chapter 17, Monitoring Fabric Performance In the section "Limitations of Top Talker monitors" on page 397, add the following item: • Fabric mode Top Talker monitors and FC-FC routing are not concurrently supported. Fabric OS Documentation Updates 11 53 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 24
FC switch as well as on the Brocade HBAs. This section describes the configuration steps you do on the switch. See the Brocade Adapters Administrator's Guide for a detailed description and requirements of N_Port trunking. 1. On the switch side, perform the following steps: a. Configure both ports - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 25
296 enabled for ports 3/40 and 3/41. 2. On the host side, enable trunking as described in the Brocade Adapters Administrator's Guide. 3. On the switch side, enable the ports using the portEnable command. switch:admin> portenable 3/40 switch:admin> portenable 3/41 Fabric OS Documentation Updates 13 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 26
4 Documentation Updates for Fabric OS v6.4.1 and later 14 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 27
To change the password for user "brocadeUser" from an admin account noninteractively: switch:admin> passwd brocadeUser -old brcdPasswd -new mynewPasswd Password changed. Saving password to stable storage. Password saved to stable storage successfully. Fabric OS Documentation Updates 15 53-1002063 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 28
on a port: switch:admin> perfaddusermonitor 1/4 "0, 0xff, 6" User monitor #1 added switchName A switch name can include up to 30 characters on all platforms running Fabric OS v.6.2.0 or later. On the Brocade 300, 5100, 5300, and 5410 platforms running earlier firmware versions, the switch name can - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 29
pages were accidental deleted from the code and in the v6.4.0 Command reference. These commands are still valid in all v6.x firmware versions. However, the recommendation is to use the more recent commands, perfMonitorShow and perfMonitorClear. Fabric OS Documentation Updates 17 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 30
license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 31
license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 32
that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands none Examples To display commands related to performance monitoring: switch:admin> perfhelp perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 33
license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 34
display cumulative information from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end monitor(s) defined on port 53. KEY SID DID OWNER_APP TX_COUNT RX_COUNT 0x0000000000000000 192.168.169.40 perfAddEEMonitor, perfHelp 22 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 35
license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 36
filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/52 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP .169.40 6 SCSI_WR WEB_TOOLS 0x000000000000033a 192.168.169.40 perfMonitorShow, perfHelp 24 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 37
. For a description of the class thresholds supported in Fabric OS and the restrictions that apply to some of the classes in terms of support for V/VE/VEX ports and GbE ports, refer to the help page for fwConfigure or consult the Fabric Watch Administrator's Guide. In Access Gateway mode, only - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 38
switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show port Buffer Size: 0 C 75 C 10 Value history: 33 C Disabled? No Locked? No Raw history: 38 C 38 C 38 C Flags: 0x 40 TRIGGERED Counter: Access via: Function call Address: 0x100155a8 Fabric OS - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 39
port persistence time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s To display ports that have all thresholds disabled: switch:user> fwShow --disable --port Port Threshold Status 1 disabled fwClassInit, fwConfigReload, fwConfigure, fwSet Fabric OS - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 40
distance configuration is detected. NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. For details on command availability, refer to the Fabric OS Command Reference, Appendix A. This command is only supported only on the Brocade FC8 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 41
supported when the slot is online switch:admin> slotpoweroff 11 switch:admin> slotpoweroff 12 switch:admin> bufopmode --set 12 Buffer optimized mode is turned on for slot 11 switch:admin> bufopmode --reset 12 Buffer optimized mode is turned off for slot 12 switch:admin> slotpoweron 11 switch:admin - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 42
across switch reboots or power cycle. Use the portCfgShow command to display user-configured fault delay settings. NOTES OPERANDS EXAMPLES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 43
Limit Credit Recovery ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Fport Buffers Port Auto Disable Fault Delay 0001 0000 0000 0000 (output truncated) portCfgShow Command RBAC permissions and AD types Refer to Table 2 for the RBAC and Admin Domain availability of new Fabric OS v6 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 44
can wait after it is received on the ingress port and before it is delivered to the egress port. If the frame waits in the egress buffer for more than the configured hold time, the switch drops the frame, replenishes sender's credit, and increments the counters sts_tx_timeout and er_c3_timeout on - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 45
switch: Switch:admin> configure Not all options will be available on an enabled switch. To disable the switch, use the "switchDisable" command. Configure... Fabric parameters (yes, y, no, n): [no] yes Configure edge hold time (yes, y, no, n): [no] yes Edge hold time: (100..500) [220] System services - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 46
on the RASlog messages, refer to the Fabric OS Message Reference. Add the following text to the Notes section: The credit recovery commands are supported only on backend ports of Condor, Condor 2, and Condor 3-based blades in the Brocade DCX, DCX-4S, DCX 8510-8, and DCX 8510-4 chassis. 34 Fabric - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 47
with LrOnThresh To disable backend port credit recovery and to display the configuration: switch:admin> bottleneckmon --cfgcredittools \ -intport -recover off switch:admin> bottleneckmon --showcredittools Internal port credit recovery is Disabled Fabric OS Documentation Updates 35 53-1002063 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 48
ability to enable alerts for both kinds of bottleneck. 2. Credit recovery enhancements: The credit recovery configuration command has been enhanced to support on-demand checking of certain types of backend ports for credit loss. 1. Support for more granular alerts SYNTAX The syntax for the enable - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 49
to allow congestion and latency alerts; overrides switch-wide configuration: switch:admin> bottleneckmon --config -alert 5 To change the bottleneck detection configuration on port 5 to disable alerts; overrides switch-wide configuration: switch:admin> bottleneckmon --config -noalert 5 The output of - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 50
the core blade or core blade backend ports) when credit loss has been detected on these ports. If complete loss of credit on a Condor2 backend port causes frame timeouts, a link reset will be performed on that port regardless of the configured setting, even if that setting is -recover off. When used - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 51
recovery examples To examine a backend port for credit loss: switch:admin> bottleneckmon --cfgcredittools \ -intport -check 10/4,30 Started Credit loss Detection on slot 10 port 4 VC 30. Please wait.... Detected credit loss. Link Reset performed. Fabric OS Documentation Updates 39 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 52
with a good EOF. Brocade highly recommends that you contact your service provider if you encounter such errors. If the error appears to be an isolated incident, you may enable auto SerDes tuning for a short period of time (24-48 hours) to see if this resolves the problem. Then disable the function - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 53
serDesTuneMode 5 EXAMPLES To enable SerDes tuning optimization on all backend ports and to display the configuration: switch:admin> serdestunemode --autoset Autotunemode is turned on switch:admin> serdestunemode --show Autotunemode is turned on To disable SerDes tuning optimization on all - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 54
5 serDesTuneMode 42 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 55
BROCADE CONFIDENTIAL Fabric OS Message Reference Chapter 6 In this chapter Replace and update the chapters as described in the following sections: •Documentation updates for Fabric OS OS v6.4.0 and later The updates in this chapter are for the Fabric OS Message Reference Supporting Fabric OS - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 56
BROCADE CONFIDENTIAL Probable Cause Indicates an internal error in the ASIC hardware problem persists FC stack. Probable Cause Indicates a FLOGI was sent to the FC stack by the FCoE driver but login was rejected by FC stack. Recommended No action is required. Action Severity INFO 44 Fabric OS - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 57
EA DRAFT: BROCADE CONFIDENTIAL Chapter 57, KAC System Messages 6 Chapter 57, KAC System system-name>, Putting the Actual DEK to the KV failed. Actual Key: . Error code=, string=. Fabric OS Documentation Updates 45 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 58
IP>. Error code=, string=. Indicates that key archival client is unable to communicate with the primary or backup key vault. Recommended Change the switch key vault settings and/or ensure that the configured Severity ERROR 46 Fabric OS Documentation Updates 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 59
," is missing. For complete information about the swFabricWatch Trap severity, please refer to the following sections in the Fabric OS MIB Reference Guide, part number: 53-1001768-01: • "Understanding SNMP basics" • "Loading Brocade MIBs" • Table 14: SW-MIB Traps SNMP trap counters The following - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 60
the term used to configure "in between" buffer values, as shown below. In this example, the high threshold value is 5 and the buffer value is 1. Therefore, the "in-between" boundary value is 4. Enter the portThConfig command using the following parameters. portthconfig --set port -area crc -highth - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 61
(FCFW) In this appendix •FC Fast Write (FCFW) concepts 50 •Configuring and enabling FCFW 52 •Disabling FCFW 53 •Disabling FCFW flows without removing FCFW 54 NOTE Fibre Channel Fast Write is currently only supported by the 7500 switch and FR4-18i blade. Fabric OS Documentation Updates 49 53 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 62
Channel ISLs implemented through the FC-FC Routing Service (FRS) rather than FCIP . FIGURE 1 Typical network topology for FCFW Platforms and OS requirements for FCFW Fabric OS supports FCFW between two Brocade 7500 routers or two FR4-18i blades connected by a Fibre Channel network. FCFW is a new - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 63
do not support FCFW. An FCFW-specific zone configuration is used to filter FCFW flows. Hardware considerations for FCFW FCFW is implemented in a hardware configuration consisting of two Brocade 7500 switches or two Brocade 48000 or DCX directors with FR4-18i blades connected by Fibre Channel ISLs - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 64
for Fabric OS v6.4.0 and v6.4.1 • FC ports on both the 7500 switch and the FR4-18i blade are organized into two groups. Ports 0-7 form one group, and ports 8-15 form the other. A maximum of four ports in each group may be configured as FCFW. • The maximum bandwidth available for FCFW is 4 Gbps per - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 65
the portcfg fastwrite command. portcfg fastwrite --disable 3. Enable a non-FCFW zoning configuration to remove and replace the fcacc zone that includes the WWNs of the devices that were plugged into the ports you disabled in step 1. Fabric OS Documentation Updates 53 53-1002063-09 - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 66
host without removing FCFW on the port. 1. Verify you are using Fabric OS version 6.2.0f or a later version using the firmwareshow command. 2. Disable the port on which you want to disable FCFW, using the portdisable command. 3. Enable a non-FCFW zoning configuration to remove and replace the fcacc - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 67
for the Brocade DCX Backbone Hardware Reference Manual, publication number set to faulty, rc= or , [EM-1003], 40, SLOT 7 | FFDC | CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown hardware manual). 1. Open a Telnet session to the chassis and log in to the active CP as admin - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 68
settings. 4. Contact Brocade Technical Support for a replacement WWN card. Technical Support the release of Fabric OS 7.0.0c, but users with earlier versions of the Fabric OS should also NOT run your chassis manual). 1. Open a Telnet session to the chassis and log in to the active CP as admin. The - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 69
for the Brocade DCX-4S Backbone Hardware Reference Manual, publication number set to faulty, rc= or , [EM-1003], 40, SLOT 7 | FFDC | CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown hardware manual). 1. Open a Telnet session to the chassis and log in to the active CP as admin - HP Brocade 8/12c | Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 70
settings. 4. Contact Brocade Technical Support for a replacement WWN card. Technical Support the release of Fabric OS 7.0.0c, but users with earlier versions of the Fabric OS should also NOT run your chassis manual). 1. Open a Telnet session to the chassis and log in to the active CP as admin. The
53-1002063-09
02 August 2012
®
Fabric OS
Documentation Updates
Supporting Fabric OS v6.4.x