HP® cc3300 Carrier Grade Server Quick Start Guide Document Release Date: July 2002 This guide contains basic instructions for setting up the system and accessing the Product Guide from the CD. Manufacturing Part Number: A6900-96002 - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 2
The HP cc3300 Carrier Grade Server may contain design defects or errors known as errata which may cause the product to deviate from published specifications. , if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 3
Contents Specifications ...5 Regulatory Specifications and Power for the First Time 17 Warnings ...19 WARNING: English (US) ...20 AVERTISSEMENTS : Français 22 WARNUNG: Deutsch ...24 AVVERTENZA: Italiano...26 ADVERTENCIA: Español 28 HP cc3300 Carrier Grade Server iii Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 4
iv HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 5
Specification Height Width Depth Front clearance Side clearance Rear clearance Weight Value 3.5 inches (89 mm) 17.5 inches (445 mm) 20 inches (508 mm) 2 inches (76 mm) 1 inches (25 mm) 3.6 inches (92 mm) 35 Lbs (15.9kg) Figure 1. Front View HP cc3300 Carrier Grade Server 5 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 6
A Limit, Radiated & Conducted Emissions · EN55024, ITE Specific Immunity Standard · EN61000-4-2, ESD Immunity (Level 2 Contact Surge · EN61000-4-6, Conducted RF · EN61000-4-8, Power Frequency Magnetic Fields · EN61000-4-11, Voltage Class A Limit 6 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 7
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. can be determined by turning the equipment off and on; the user is encouraged to try to correct the interference by one or HP cc3300 Carrier Grade Server 7 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 8
is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. ICES-003 (Canada) Cet appareil product safety label which is located visibly on the external chassis. 8 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 9
an anti-static wrist strap attached to chassis ground of the server when handling components (e.g. any unpainted metal surface). CAUTION, Use grounded outlet Make sure that the power service connection is through a properly grounded outlet. HP cc3300 Carrier Grade Server 9 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 10
an AC power disconnect for the entire rack unit. This mains disconnect must be readily accessible, and it must be labeled as controlling power to the entire rack, not just to the server(s). To remove all power, two AC cords must be removed. 10 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 11
power system for the equipment rack is installed with more than 10 amperes of protection, you must provide supplemental protection for the server. The overall current rating of a server configured with two power supplies is less than 7 amperes. HP cc3300 Carrier Grade Server 11 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 12
" in the HPl cc3300 Carrier Grade ServerProduct Guide. CAUTION Temperature: The temperature, in which the server operates when installed in an equipment rack, must not go below 5 °C (41 °F) or rise above 40 °C (104 °F). Extreme fluctuations in temperature can cause a variety of problems in your - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 13
2. A Bezel B Peripheral Bay C NMI Switch D System Power Switch E System Reset F Alarm: CRT G Alarm: MJR H Alarm: MNR I Alarm: PWR J Status: NIC K Status: DSK L Status: ON M Bezel Removal Thumbscrews N Hard Drive Tray Figure 2. Front Panel HP cc3300 Carrier Grade Server 13 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 14
continuously lit, indicates the presence of DC power in the server. The LED (green) LED goes out when the power is turned off or the power source is disrupted. When it is blinking green, it indicates that the system is in ACPI sleep mode. 14 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 15
-ROM Drive C Front Panel Switches and LEDs D Hard Drive Tray GF E OM12817 E Left SCSI Drive Bay F Hard Drive Tray Ribbon Cable Connector G Hard Drive Tray Power Connector H Right SCSI Drive Bay Figure 3. Front View with Bezel Removed HP cc3300 Carrier Grade Server 15 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 16
and mouse). Serial port (COM2), 8-pin RJ45 connector USB port 0 Two ground lugs for attachment of grounding wire to chassis. Use only when configured with DC power supply. AC input power connectors for AC input power supply cage (shown in inset) 16 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 17
Grade Server System Product Guide. Follow these steps to power up the cc3300 Carrier Grade server for the first time: 1. Make sure all external devices, such as a monitor, keyboard, and mouse, have been connected. 2. Plug in the AC power cord or connect the DC power wiring to the back of the chassis - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 18
NOTE For information on how to use the BIOS Setup Utility, see the HP cc3300 Carrier Grade Server Product Guide. 7. From the Main menu of the BIOS Setup Utility, use the arrow can monitor the remainder of the boot progress on the video display. 18 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 19
Warnings WARNING: English (US) AVERTISSEMENTS : Français WARNUNG: Deutsch AVVERTENZA: Italiano ADVERTENCIA: Español HP cc3300 Carrier Grade Server 19 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 20
that cables, add-in boards, and other components are properly installed. 3. Attach the covers to the chassis with the screws removed earlier, and tighten them firmly. 4. Connect all external cables and the power cord to the system. continued 20 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 21
chassis power supply cords, because they serve as the product's main power disconnect. Servers can be too heavy for a single person to lift or move safely. Depending on the server, use two people or a mechanical assist to lift or move the server. HP cc3300 Carrier Grade Server 21 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 22
les panneaux du châssis avec les vis retirées plus tôt. 4. Rebranchez tous les cordons d'alimentation CA et câbles externes au système. suite 22 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 23
type équivalent recommandé par le fabricant. Débarrassez-vous des piles usagées conformément aux instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. auxiliaire pour soulever ou déplacer le serveur. HP cc3300 Carrier Grade Server 23 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 24
den zuvor gelösten Schrauben gut am Gehäuse fest. 4. Schließen Sie alle externen Kabel und das Netzkabel an das System an. Fortsetzung 24 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 25
kann, da das Gerät nur über dieses Kabel vom Netz getrennt wird. Um einen Server sicher anzuheben und zu bewegen ist eine Person nicht ausreichend. Bewegen Sie den Server, je nach Größe, entweder zu zweit oder mittels einer mechanischen Hilfe. HP cc3300 Carrier Grade Server 25 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 26
installati correttamente. 3. Fissare saldamente i coperchi al telaio utilizzando le viti precedentemente rimosse. 4. Collegare tutti i cavi esterni e il cavo o i cavi di alimentazione in c.a. al sistema. 26 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 27
necessario scollegare l'alimentazione principale. I server possono risultare troppo pesanti per essere sollevati o spostati da una sola persona. Alcuni server devono dunque essere sollevati o spostati da due persone o da un assistente tecnico. HP cc3300 Carrier Grade Server 27 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 28
con los tornillos que ha retirado anteriormente y apriételos firmemente. 4. Conecte todos los cables externos y los cables de alimentación de CA al sistema. continuación 28 HP cc3300 Carrier Grade Server Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 29
una sola persona los levante o los mueva de forma segura. Dependiendo del servido, utilice dos personas o una ayuda mecánica para levantar o mover el servidor. HP cc3300 Carrier Grade Server 29 Quick Start Guide - HP Cc3310 | Quick Start Guide - HP cc3300 Carrier Grade Server - Page 30
2 HP cc3300 Carrier Grade Server Quick Start Guide
Manufacturing Part Number: A6900-96002
HP
®
cc3300 Carrier Grade Server
Quick Start Guide
Document Release Date: July 2002
This guide contains basic instructions for setting up the system and accessing
the Product Guide from the CD.