HP Cc3310 Intel Server Management (ISM) Installation and User's Guide
HP Cc3310 - Server - AC Option Manual
View all HP Cc3310 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Cc3310 manual content summary:
- HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 1
Intel Server Management (ISM) Version 5.5.5 for the hp Carrier-Grade Server cc3310 Installation and User's Guide Version 3.0 Manufacturing Part Number: cc3310_W2K3_IntelSrvrMgmnt January 2006 U.S.A. © Copyright 2006, Hewlett-Packard Development Company, L.P. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 2
Utilities Resource CD-ROM has been provided with your server. It contains a complete documentation set for the server. Included on the CD-ROM is the hp Carrier-Grade Server cc3310 Product Guide, which contains in-depth troubleshooting, installation, and repair information. The CD will autorun when - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 3
Legal Notices...2 1 INTRODUCTION ...9 New ISM Features...9 System Requirements ...9 Support for SNMP-Based Third-Party Server Management Software 9 Management Station OS and Minimum Hardware Requirements 10 Managed Server Requirements ...10 Overview of the Configuration and Installation Process - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 4
Event Paging (PEP)...24 E-mail Alerts...25 Launching ISM Tools ...25 ISM Console ...25 HP OpenView Network Node Manager 25 Using the ISM Console...25 ISM Console Main Screen ...26 The Navigation Pane...28 Configure Server Health for Static IP Address 28 The Tool Pane ...28 The Status Bar...29 - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 5
Management (ISM) Installation and User's Guide Introduction System Information...39 Temperature ...40 Third-Party Components...40 Voltage...40 Managing Servers with PIC...40 Viewing and Configuring Sensor Information 40 Viewing System Information...41 Configure Server Health for Static IP Address - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 6
Intel Server Management (ISM) Installation and User's Guide Introduction Rebooting to the Service Partition...55 Displaying Configuration Status LAN on the Server 62 Configuring the Console ...62 Using the Serial over LAN Feature ...63 Running the Network Proxy (dpcproxy 63 Manually Starting the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 7
Intel Server Management (ISM) Installation and User's Guide Introduction CLI Commands...69 alarm -s...70 alarm -q ...70 76 service ...77 set ...78 shutdown ...78 version...78 8 NATIVE COMMAND LINE 79 Native Command Line Overview ...79 Setup and Configuration ...79 Connection Mechanism ...79 Server - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 8
Intel Server Management (ISM) Installation and User's Guide Introduction Locally Booting the Server from the Service Partition 101 Utilities ...102 Service Partition Administrator (SPADMIN 102 System Setup Utility ...102 FRUSDR Loader Utility ...102 8 - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 9
: • Microsoft® Windows® XP Professional • Microsoft Windows 2000 Advance Server, Service Pack 3 or higher • Microsoft Windows 2003 Advance Server (HostRAID is not supported) • Microsoft Windows 2000 Professional, Service Pack 3 or higher ISM Server Instrumentation Software, which is installed on the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 10
Intel Server Management (ISM) Installation and User's Guide Installation Steps Simple Network Management Protocol (SNMP) support must be installed to use HP OpenView. For SNMP configuration information, see your Windows or Red Hat Linux documentation. On the console system(s), when configuring SNMP - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 11
service partition exists. (Look for boot option F4. If no service partition exists-F4 is not found-refer to the hp Carrier-Grade Server cc3310 Product Guide for information and instructions the ISM CD. You will have to take some manual steps on each management station during the installation or - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 12
HP Server cc3310 Information Diagnostic and Utility Resource CD in the CD drive and reboot the server. When the managed server boots from the Resource CD, the Server asset tag. i. Install or update the service partition. This task is a two-step process with a server reboot between the two steps. j. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 13
) Installation and User's Guide Intel Server Management (ISM) Concepts If the managed server already has an operating system installed, then you can remove the CD and let the server reboot after configuration. Step 3. Prepare for ISM Installation On a new managed server; before installing ISM and - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 14
Guide Intel Server supported Windows or operating systems (see page 9). For Linux servers, you must individually install ISM on each system. Choose the installation instructions Servers Before starting, verify that HP OpenView is not running. Use the instructions below to install to Windows servers - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 15
and User's Guide Intel Server Management (ISM) ISM components. 2. Multiple System Install is not supported. Custom Install is available to allow the OFU for installing ISM and TAM using this script. 1. Insert the HP Server cc3310 Information Diagnostics and Utilities Resource CD into CD-ROM Drive. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 16
Management (ISM) Installation and User's Guide Intel Server Management (ISM) Concepts 8. Scroll down to the kernal is not SMP, you may recompile the flash update driver using source code available from support.intel.com. d. Upon successful completion of the script, the utility and the flash update - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 17
manual changes to the /ect/hostss file must be made. The action is based on the assumption that the managed server will be maintaining a consistent IP address for the NIC1 on port. (The NIC on port 1 must be configured with a static IP address, or the DHCP server servicing These instructions are - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 18
the following Intel web site: http://support.intel.com/support/network/adapter/1000/software.htm Download the Native SNMP software for your operating system and follow the installation and configuration instructions included in the download package. Customizing Windows Servers After Setup • The set - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 19
the server. Intel Server Management (ISM) Installation and User's Guide Intel Server Management server health or condition. For information about the format of SNMP traps used by LanAlert, see the ISM Technical Product Specification, available at Intel's Web support site. Activate SNMP Trap Service - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 20
Guide Intel Server Management (ISM) Concepts Load MIB Files for SNMP Integration ISM includes MIB files as listed below for support of managed server 17. You must load the MIB files into your third-party management tool (HP OpenView or CA Unicenter TNG). Each tool provides a menu or other way to - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 21
Management (ISM) Installation and User's Guide Intel Server Management (ISM) Concepts Uninstalling ISM system. Always reboot your system after uninstalling any ISM component. Uninstalling ISM from Managed Linux Servers You must uninstall ISM locally from each Linux system. To do so: 1. Log in as - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 22
and User's Guide Intel Server Management (ISM) Refer to Installation of ISM for Managed Linux Servers on page 15 for specific instructions. 3. Upon successful completion of the script, to uninstall the utility and supporting drivers: • rpm -e ofudrvr • rpm -e ipmidrvr (see note below) - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 23
can use DPC to investigate the cause of the alert, to initiate corrective action, and to restart the server into normal operation. You can also run other utilities on the service partition. DPC communicates either with the serial Emergency Management Port (EMP), which is a serial port for a modem or - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 24
Intel Server Management (ISM) Installation and User's Guide Platform Instrumentation Control (PIC) Details • Platform Event Paging is a service that notifies a numeric pager. • E-mail Alerting sends a notice to specified e-mail IDs. • System ID LED alerts use the system ID LED to indicate a system - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 25
NOTE Intel Server Management (ISM) Installation and User's Guide Platform Instrumentation Control (PIC) Details Paging alerts from the popup menu. Supported third-party management software includes the HP OpenView Network Node Manager. After launching ISM tools HP OpenView, the management console - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 26
User's Guide Platform Instrumentation Control (PIC) Details • Launch the management tools on the managed servers ISM Console server discovery Add-Manually add a server to the tree Delete-Delete the selected server from the tree Delete All-Delete all servers from the tree Stop Discovery-Stops server - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 27
. If any of the tools supported by the ISM Console are installed or removed from a managed server, you should rediscover the server using Server->Add or Server->Discover to update the tool list for that server. Add You can manually add a server to the ISM Console server tree by entering its IP - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 28
name. 2. Save the edits. 3. Restart network services on the server or reboot the server. The Tool Pane When you select a server in the navigation pane, the tool pane displays a set of icons representing the management tools supported on that server. You can start the management tool for the managed - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 29
Intel Server Management (ISM) Installation and User's Guide Platform Instrumentation Control (PIC) Details The Status Bar The status bar displays information about ISM Console operations, such as the number of ISM servers discovered and the number of servers still to be processed. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 30
4 Platform Instrumentation Control (PIC) Details Platform Instrumentation Control (PIC) communicates with servers running supported operating systems, and provides real-time monitoring and alerting for server hardware sensors. PIC communicates over the LAN to the Platform Instrumentation (PI) - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 31
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details • Displaying a message on the a tree view. You can expand the view to show the sensor types supported on the managed server and further expand it to display detailed information. A presentation area on the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 32
Server Management (ISM) Installation and User's Guide power and reset option. Immediate Power Off Server-Powers off the server and you must manually restart power or use another interface like DPC Not supported. Not supported. Help Topics-Accesses PIC help topics. About PIC-Displays PIC version - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 33
Guide Client SSU (CSSU) Details Toolbar The toolbar gives quick access to some menu items. To hide the icon toolbar, click the right mouse button over the toolbar, and then click the Hide item that appears. Navigation Pane The Navigation Pane shows a tree view of server for each supported threshold. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 34
IP address. Chassis PIC monitors chassis door open/closed switches for managed servers that support this feature. The number of sensors monitored depends on the server chassis. If a server supports chassis sensors, the chassis intrusion sensor screen displays the current security status. When - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 35
Installation and User's Guide Client SSU (CSSU) Details PIC monitors two types of fans: • Rotation-sensing fans-not used in the HP Server cc3310PIC can detect and it displays the actual fan RPM value for systems that support this feature. Each RPM-sensing fan is independently configurable with its - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 36
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details Figure 4-1 Fan Removed Message PIC also refreshes the PIC interface so that the removed fan is no longer reported. For example, if the system supports five fans, and Fan 3 is removed, PIC will display status for - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 37
4-3 Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details Fan Status Display with all Fan Installed Memory Displays Memory and memory error correction are represented by the following items: • Memory Devices • Memory Arrays For systems that support Error Correction - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 38
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details • Sets the Last Error Unit represents power-supply redundancy. For systems that support it, PIC monitors the status of the power supplies in the managed server. The power unit sensor screen displays information and - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 39
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details If a power supply reports a slot status on all slots in the managed server. The slots are categorized into two groups: • PCI Hot-Plug (PHP) slots, if the server hardware supports PCI Hot-Plug • All other non-PHP - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 40
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details Temperature The temperature status, and sensor error counts, and lets you set sensor thresholds. If a threshold is not supported it is grayed out. The Alert Actions tab lets you set what kinds of actions to take - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 41
Server Management (ISM) Installation and User's Guide supports FRU data, this information is also displayed on the Inventory Information tab for that component. Configure Server server, together with the server name. 2. Save the edits. 3. Restart network services on the server or reboot the server. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 42
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details The ISM GUI refreshes the SEL as follows: 1. Reboot the system 2. Press F2 to run BIOS setup 3. Select Server Management 4. Enable the entry for clearing the SEL. Configuring Thresholds There are two basic types of - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 43
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details 5. If you want to : • Single bit memory error • Processor thermal trip • Power supply failed NOTE For systems that support rotation-sensing fans, the fan RPM threshold setting displays a 0 and is read-only in PIC. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 44
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details 3. Because the threshold was exceeded The contents of the file are not important. You must then delete this file after the problem is fixed to allow the software to operate normally. The LRA.NOT file must be in the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 45
Server Management (ISM) Installation and User's Guide applications). The server is set to a state ready for manual power-off or server installation. Immediate NMI Select this option if you want to cause a hardware Non-Maskable Interrupt (NMI). If this feature is not supported on the managed server - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 46
Intel Server Management (ISM) Installation and User's Guide Client SSU If ISM has already been installed, use the following configuration instructions depending on the server operating system. a. Windows 2000/Windows 2003 - Set the for third-party component instrumentation supported by PIC. 46 - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 47
Table 4-5 Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details Supported Third Party Component Instrumentation Controller Choices Adaptec SCSIa Storage Device Events Group: Storage Device - Status OK (Informational Event) Storage Device - Status Changed to - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 48
and User's Guide Client SSU (CSSU) Details Configuring the Watchdog Timer Value Each baseboard supported by PIC has a watchdog timer implemented in the hardware; the timer is disabled by default. When enabled, the timer continually decrements to test the response of the server operating system - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 49
Intel Server Management (ISM) Installation and User's Guide Client SSU (CSSU) Details • Number of Pages-specifies how display format on the Options dialog. 3. Click OK. NOTE For servers that support server health update events, configuring the console refresh interval is not necessary or applicable - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 50
Guide Client SSU (CSSU) Details Default threshold values are stored in Sensor Data Records (SDR) in nonvolatile storage on the baseboard. These values are determined and configured during baseboard manufacturing and are therefore not documented in this manual be displayed at the server, sent in a - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 51
Installation and User's Guide Client SSU (CSSU) Details Message Description Check Security Sensor at System chassis front or side panel has been opened, Check Physical Container Global Table at or it was open and has been closed. Check Cooling Fan at System fan has - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 52
Management (ISM) Installation and User's Guide Client SSU (CSSU) Details E-mail Settings Configure e-mail by selecting Configuration > Email Alert Configuration. This configuration is global to the server and is not sensor-specific. Specify these settings on the Email Alert Configuration screen - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 53
server to either EMP mode or Redirect Mode • Maintain a Phonebook for remote server connection management • Reboot to the service partition to run service-partition-based utilities on the server server's onboard NIC. DPC is supported only on the onboard NIC1 interface (see your server Product Guide - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 54
Management (ISM) Installation and User's Guide Client SSU (CSSU) Details Starting the DPC Console The preferred way to start DPC is to double-click the DPC Console icon in the tool pane of your management software (ISM Console) after selecting the appropriate managed server. You can start DPC under - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 55
on the hard disk that you establish when initially setting up the server. (Refer to the HP Carrier Grade Server cc3310 Product Guide and "Appendix A" of this manual, for additional information.) The service partition contains utilities, diagnostics, and other software required for remote management - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 56
(ISM) Installation and User's Guide Client SSU (CSSU) Details To boot to the service partition: • You must be connected to the server by LAN on the NIC port that is labeled as "1". • The connected server must contain BIOS support for booting to the service partition. • A service partition must be - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 57
BIOS can detect any potential data corruption before the actual hardware configuration occurs. NOTE Depending on where the hard drive containing the service partition is located on the server, it can take a fair amount of time before the CSSU is ready to accept user input. If the system hangs, you - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 58
is to help users get more information during a server reboot to the service partition. Phonebook The Client SSU shares a phonebook with DPC. You can use the phonebook to establish connections with supported platforms. Open the phonebook from the Server menu or by using the phonebook icon on the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 59
Guide Serial Data and the Command Line Interface System Event Log Manager The System Event Log (SEL) contains a sequential record of events that have occurred in the remote server. The SEL can help you determine the cause of server may be of interest while troubleshooting a system failure. Using the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 60
Guide Serial Data and the Command Line Interface System Update Manager The System Update Manager (SUM) lets you update the server operations, although not all servers support all types of updates: • Determines the current revision of system BIOS and firmware on server controllers • Updates BIOS - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 61
environment where you might want to monitor many servers. NOTE The dpccli interface does not support formatted output like a VT100 or UTF8 terminal would page 14). The network proxy (dpcproxy.exe) is installed as a service and automatically starts each time the system boots. The dpccli.exe - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 62
Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Linux Package Installation To install the Serial over LAN and CLI features on Linux, follow the steps below. You can install ISM server software first if you choose, as described in Chapter 2. However, it - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 63
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface on a central proxy server. Manually Starting the Network Proxy on Windows From Windows you can start, stop, and check on the network proxy as follows: • Use the Service control Manager to view the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 64
Server Management (ISM) Installation and User's Guide and input text are ignored. Installs the proxy as a Windows service. You can also specify the other options to be used each on the command line the detected language is not a language supported by CLI; the network proxy defaults to English. Keeps a - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 65
Guide Serial Data and the Command Line Interface • Set up the BIOS • Read sensor values • Display the network configuration of the BMC You can also execute Perl scripts to issue commands to multiple remote servers . 3. Only a single DPCCLI session is supported at one time. 4. After entering the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 66
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface 6. CLI commands: 1. Configure the session as described above. 2. At the Server: prompt provide the IP Address of the server to which you want to connect. 3. Provide a username if applicable. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 67
Guide Serial Data and the Command Line Interface server console system. Initiate the connection using the telnet instructions previously described. The Console Interface (dpccli) For such as VT100 and VTUTF8 is not required. To support noninteractive use, dpccli accepts command-line options that - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 68
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface When creating with the Network Interface Card (NIC) used by the Baseboard Management Controller (BMC). For server, specify either an IP Address or DNS hostname. If you do not specify this option, - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 69
system that the management station (your console system) should contact for service. By default, the IP Address is the local host (127.0.0.1). command usage. Displays the Globally Unique ID (GUID) of the managed server. Causes the server to signal its location. Displays the network configuration - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 70
) Installation and User's Guide Serial Data and the Command Line Interface Command reset sel sensors service set shutdown version Description Performs a reset operation on the managed server. Displays the System Event Log (SEL) records. Displays the current status of the server's sensors. Lets you - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 71
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Description: The -q option designates this command as the query alarm command. This command queries Telco alarm records in - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 72
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface alarm -c -g 4 -o 5 -a 1 Alarm ID 1 cleared (Generator ID 4) boot Syntax: boot {normal | service} [-f] [-c] Description: Sets the IPMI boot options and then resets the system. By default, the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 73
information is displayed for all CLI commands. Options: [CLIcommand] Any valid CLI command. id Syntax: id Description: Displays the 16-byte system Globally Unique Identifier (GUID) of the managed server in the conventional GUID format; for example, 422e7704-23f5-4706-a943-a7859c073aed. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 74
a value for seconds, the default is 15 seconds. If you provide the value 0 for seconds, the server will identify itself indefinitely. The maximum value for seconds is 255. Not all servers support specifying the number of seconds. [-off] Turns off the blinking LED or beep. This option has no - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 75
Guide Serial Data and the Command Line Interface Syntax: power {on [-c]} | {off [-f]} Description: Initiates a power-up or power-down sequence on the managed server the Platform Instrumentation (PI) software must be installed on the server. Options: [-c] [-f] Switches the session to Serial over - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 76
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Description: Displays System Event Log (SEL) records. Each record displays on a single line and uses the following format: - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 77
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface . ftp start Instructs the RSA to start the FTP server. Once the FTP server is started, standard OS FTP clients can be used to directly transfer files to and from the Service Partition. An - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 78
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface set Syntax: without performing a graceful shutdown. A graceful shutdown requires Intel Server Management to be installed on the server. Causes the software to attempt a graceful shutdown and then - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 79
-based commands to the server's Baseboard Management Controller (BMC) using a serial port connection. Terminal mode supports standard binary IPMI 1.5 on the server, run the System Setup Utility (SSU) from the service partition or the Resource CD, as described in your server Product Guide and follow - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 80
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface i. [SYS] and [OK] to show a successful login. 14. At this point, you can type any supported Terminal mode command (see the following pages). 15. To logout type [SYS PWD -X]. Native Command Line - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 81
messages across multiple lines by using the line continuation backslash character followed immediately by an input newline sequence. Line continuation characters are supported for both text and hex-ASCII commands. Hex-ASCII Command Format Binary IPMI commands are sent and received as a series of - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 82
User's Guide Serial Data and the Command Line Interface 1 [7:2] - Net Function (odd) [1:0] - Responder's LUN 2 [7:2] - Requester's Sequence Number [1:0] - Bridge field 3 Command Number 4 Completion Code 5:N Data Native Command Line IPMI Message Bridging Native Command Line supports the - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 83
Hex-ASCII command example (IPMI Reset Watchdog Cmd): [18 00 22] [1C 00 22 00] Text command example: [SYS TMODE] [OK TMODE] Table 8-4. Native Command Line Text Commands Command SYS PWD SYS TMODE SYS SET BOOT XX YY ZZ AA BB SYS SET BOOTOPT XX YY...NN Switches -U USERNAME < - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 84
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Command Switches Description [6:0] - Boot option parameter selector YY...NN -- Boot Option Parameter Data Per Table 8-5. Passing 0-bytes of - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 85
text prefix. To enable the OEM commands this command must be executed every time a session is activated. Displays the 16-byte system GUID of the managed server. Output formatted similar to what is displayed by the DPCCLI command. Displays the network configuration of the BMC. Using the mac, ip - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 86
Server Management (ISM) Installation and User's Guide (normal | service): This command BIOS does not support the required boot Instructs the server to signal its location by turning on the LED or beep. IDENTIFY = enables the server to identify itself for 15 seconds. IDENTIFY ON = enables the server - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 87
COMMAND Displays the syntax and usage information for the command specified. If a command is not specified the current IPMI revision, FW version numbers and all supported commands are displayed. a. Execution of graceful OS shutdown has restrictions listed below. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 88
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Performing a graceful 10b = Reserved 11b = Reserved Data 1 [7:0] - Service partition selector. This value is used to select the service partition from which BIOS should boot. This document does not - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 89
1b. Ignore on read. [5] - reserved. Write as 1b. Ignore on read. [4] - 0b = OEM has handled boot info. [3] - 0b = SMS has handled boot info. [2] - 0b = OS / service partition has handled boot info. [1] - 0b = OS Loader has handled boot info. [0] - 0b = BIOS/POST has handled boot info. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 90
Intel Server Management (ISM) Installation and User's Guide Serial Data and the Command Line Interface Parameter # Parameter Data capability uses PET traps, this bit is ignored if for connection modes that do not support PET such as Basic Mode and Terminal Mode. [3] - 1b = User password bypass. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 91
Parameter # Boot flags 5 (semivolatile) a (continued) Parameter Data (nonvolatile unless otherwise noted) Data 4 [7:4] - Reserved [3] - BIOS Shared Mode Override Can be used to request BIOS to temporarily place the channel into shared access mode. Per the recommendations in the IPMI - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 92
Server Management (ISM) Installation and User's Guide determine whether the boot information is stale or not. A service partition or OS loader may elect to ignore the boot information initiator, based on protocol and medium. The BMC supports five blocks of storage for this command. Previous values - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 93
Table 8-6. Native Command Line Configuration Byte 1 2 Explanation [7:6] - Reserved [5] - Line Editing 0b = Disable 1b = Enable (Factory default) [4] - Reserved [3:2] - Delete control (only applies when line editing is enabled) 00b = BMC outputs a character when or < DEL > is - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 94
server while the operating system is running. After the update has completed, the next system reset activates the newly updated BIOS and /or firmware. For installation instructions secure network connection using a Telnet Client and Terminal Services under Windows or using a Telnet Client and Remote - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 95
[-c] [-h] • Cancels all pending update operations that were performed using the utility. The utility resets the internal flags in the BIOS, BMC, and SRD to cancel the update, whether there is one or not. The FRU update cannot be cancelled with this option. Displays command line help information. - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 96
- HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 97
10 Glossary - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 98
serial ports (COM1 is internal and is not accessible) ESMC Enterprise Server Management Console, a non-ISM or third-party management console that can integrate with ISM software F FRU Field Replaceable Units G GUID Globally Unique Identifier I ICMB Intelligent Chassis Management Bus IPMI Intelligent - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 99
S SBE Single-Bit Error SCSI A type of bus used to access peripherals such as hard disks SCW Server Configuration Wizard - DOS utility to configure the server for server management features SDR Sensor Data Records SEL System Event Log SMI System Management Interrupt SNMP Simple Network Management - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 100
Intel Server Management (ISM) Installation and User's Guide Appendix A T TCO Total Cost of Ownership port-a particular network access port on a server 100 - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 101
partition remotely, using DPC, Client SSU, or the Command Line Interface (CLI), as described elsewhere in this manual. Current server platforms include a BIOS option to let you directly boot the Service Partition at startup, using the F4 key. If your platform does not have this feature, you can boot - HP Cc3310 | Intel Server Management (ISM) Installation and User's Guide - Page 102
Management (ISM) Installation and User's Guide Appendix A Utilities An option in the Server Configuration Wizard allows you to run these Server Configuration Utilities: • Service Partition Administrator (SPADMIN) • System Setup Utility (SSU) • Field Replaceable Units (FRU) and Sensor Data Record
Intel Server Management (ISM) Version 5.5.5
for the hp Carrier-Grade Server cc3310
Installation and User’s Guide
Version 3.0
Manufacturing Part Number: cc3310_W2K3_IntelSrvrMgmnt
January 2006
U.S.A.
©
Copyright 2006, Hewlett-Packard Development Company, L.P.