Notes hp StorageWorks C-series Fabric Switches for SAN-OS 3.3(4a) and FabricWare 2.1(3) This document provides additional information about the MDS 9020 Fabric Switch, the MDS 9100 Series Fabric Switches, the MDS 9200 Series Multilayer Fabric Switches, and the MDS 9500 Series Multilayer Directors - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 2
for instructions on how to determine the current SAN-OS or FabricWare version on your switch. HP strongly recommends upgrading all fabric switches to the latest supported SAN-OS and FabricWare versions. All switches in the SAN must be running the same version of SAN-OS in 2 MDS Multilayer Director - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 3
FICON is supported with SAN-OS on the MDS 9000 series switches. For supported versions and configurations refer to the SPOCK website at http://www.hp.com/storage/spock. You must sign up for an HP Passport to be granted access. 3 MDS Multilayer Director & Multilayer Fabric Switches Release Notes - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 4
HP c-Class BladeSystem with eight 4-Gbps 9124e internal FC ports and four external 4-Gbps FC ports or sixteen 4-Gbps N/A internal FC ports and eight external 4-Gbps FC ports 9020 Fabric switch with twenty 4-Gbps FC ports N/A Supported Switch Software SAN-OS FabricWare 4 MDS Multilayer - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 5
16-port 2-Gbps FC switching module 32-port 2-Gbps FC switching module Storage Services Module (SSM) MDS 9222i MDS 9216i MDS 9216A MDS 9216 MDS 9134 4-Gbps ports MDS 9134 10-Gbps ports MDS 9124 MDS 9124e MDS 9140 (ports 1-8) MDS 9140 (ports 9-40) MDS 9120 (port 1-4) MDS 9120 (ports 5-20) MDS 9020 - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 6
switches can be managed with the command-line interface (CLI) or Simple Network Management Protocol (SNMP). The graphical user interfaces (GUI) used to manage all C-series switches is Cisco Fabric Manager and Cisco Device Manager. 6 MDS Multilayer Director & Multilayer Fabric Switches Release - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 7
will ensure a safe bending radius on all fibre channel cables. This is especially pertinent in high port density (Director) installations. Please consult the relevant Cisco Hardware Installation Guide for further information. 7 MDS Multilayer Director & Multilayer Fabric Switches Release Notes - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 8
to the Cisco MDS 9000 Family Configuration Guide or Cisco MDS 9020 Fabric Switch Configuration Guide for instructions on how to connect the serial port to a host machine. INITIAL INSTALLATION RECOMMENDATIONS / REQUIREMENTS The C-series MDS 9000 Family of switches does not automatically allow SAN - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 9
HP requires in-order delivery (IOD) be enabled for all switches. There is a switch setting to enable in-order of frames during fabric failure. Note: IOD feature is not supported on the MDS login name and password switch login: admin Password: 3. Enter the following: switch# show in- - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 10
setup wizard Refer to the Cisco MDS 9000 Family Fabric Manager Configuration Guide for additional installation instructions. Note: The MDS 9020 currently runs FabricWare 2.1(3); HP recommends using the latest supported Fabric/Device Manager when managing this switch via the GUI. 10 MDS Multilayer - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 11
on C-series and M-Series Fibre Channel Switches for specific supported B-Series and M-Series software versions. CISCO MDS 9000 FLEXATTACH FlexAttach is supported on the Cisco Fabric Switch for HP c-Class BladeSystem, the Cisco MDS 9124 switch, and the Cisco MDS 9134 switch, when NPV mode is enabled - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 12
FCID. Special consideration must be taken for operating systems and devices requiring persistent FCIDs. 1. Log into the CLI of the Cisco MDS switch with admin privileges. 2. Execute the following commands for the desired VSAN: 12 MDS Multilayer Director & Multilayer Fabric Switches Release Notes - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 13
. Encryption engines are integrated on the MDS 9000 18/4-port Multiservice Module (MSM-18/4) and the MDS 9222i Multiservice Fabric Switch, eliminating the need to purchase and manage extra switch ports, cables, and applications. Traffic from any virtual SAN (VSAN) can be encrypted using SME - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 14
MDS 9222i switches and switches that include MSM-18/4 modules must be running SAN-OS Release 3.2(3) software or newer For additional information on how to install SME, refer to the Cisco MDS 9000 Family Storage Media Encryption Configuration Guide. 14 MDS Multilayer Director & Multilayer Fabric - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 15
switch using either the management console or telnet. 2. Enter your network-admin privileged account by entering your login name and password. switch login: admin Password: 3. Enter the following to enter configuration mode: 15 MDS Multilayer Director & Multilayer Fabric Switches - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 16
active interoperability mode: default loadbalancing: src-id/dst-id operational state: up 7. Type the following to copy the running configuration into the startup configuration: switch# copy running-config startup-config Refer to the Cisco MDS 9000 Family Fabric Manager Switch Configuration Guide - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 17
: admin password: switch# config terminal switch(config)# interface fc 1/9 switch(config-if)# switchport speed 2000 switch(config-if)# exit switch(config)# exit switch# copy running-config startup-config C-SERIES MDS 9134 FABRIC SWITCH The MDS 9134 switch has a base 34-port chassis - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 18
9124 FABRIC SWITCH The MDS 9124 switches have fixed configurations with 8, 16, and 24 full rate 4-Gbps fibre channel ports. The 8 and 16 port switches can be upgraded in 8 port increments with a software expansion license. C-SERIES MDS 9124e FABRIC SWITCH FOR HP C-CLASS BLADESYSTEM The MDS 9124e 12 - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 19
proper connectivity using Cisco management tools. 9. Configure the new module as you would when adding any new module to your switch. Please refer to the Cisco MDS 9000 Family CLI Configuration Guide details on configuring modules 19 MDS Multilayer Director & Multilayer Fabric Switches Release - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 20
proper connectivity using Cisco management tools. 12. Configure the new module as you would when adding any new module to your switch. Please refer to the Cisco MDS 9000 Family CLI Configuration Guide for details on configuring modules. 20 MDS Multilayer Director & Multilayer Fabric Switches - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 21
of the Information Pane Problem Description: VMware ESX on HP c-Class BladeSystem Server Blade using QMH2462 HBAs and FC Pass-Thru Module may fail to log into the C-series MDS 9216, MDS 9216A, or 16-port switching module. Workaround: Set the switch port mode to F. Problem Description: If it becomes - HP Cisco MDS 9216A | HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(4a) - Page 22
on HP c-Class BladeSystem Server Blade using QMH2462 HBAs and FC Pass-Thru Module logs into the MDS 9020 as an FL port if the switch port mode is set to auto. Workaround: Set the switch port mode to F. Problem Description: In rare cases, a device may not log into the C-series switch at the supported
© 2003 - 2009 Hewlett-Packard Company
Part Number: AA-RWEHW-TE
Printed in the U.S.A.
November 2009
Product names mentioned herein may be trademarks of their respective companies as reflected by an
associated footnote. The information in this document is subject to change without notice.
Release Notes
hp
StorageWorks
C-series Fabric Switches
for SAN-OS 3.3(4a) and
FabricWare 2.1(3)
This document provides additional information about the MDS 9020 Fabric Switch, the MDS
9100 Series Fabric Switches, the MDS 9200 Series Multilayer Fabric Switches, and the MDS
9500 Series Multilayer Directors