HP D2220sb HP D2220sb Storage Blade Maintenance and Service Guide
HP D2220sb Manual
View all HP D2220sb manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D2220sb manual content summary:
- HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 1
HP D2220sb Storage Blade Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and software. Part Number: 714240-001 February 2013 Edition: 1 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 3
electrostatic discharge ...19 Symbols on equipment...19 Storage blade warnings and cautions 20 Storage blade preparation ...20 Servicing internal storage blade components 20 Avoiding equipment damage and data loss 22 Remove the access panel ...26 Install the access panel ...26 Drive blank...26 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 4
Documentation feedback ...50 Index...51 Contents 4 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 5
to the HP website (http://www.hp.com/go/selfrepair). Parts only warranty service Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only warranty service, HP will provide replacement parts free of charge. For parts only warranty service, CSR part replacement - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 6
la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d' demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. Riparazione da parte del cliente - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 7
del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 8
CSR-Programm in Nordamerika finden Sie auf der HP Website unter (http://www.hp.com/go/selfrepair). Parts-only Warranty Service (Garantieservice ausschließlich für Teile) Ihre HP Garantie umfasst möglicherweise einen Parts-only Warranty Service (Garantieservice ausschließlich für Teile). Gemäß den - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 9
componentes, es obligatoria la sustitución de componentes por parte del usuario (CSR). Si solicita a HP que realice la sustitución de estos componentes, tendrá worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 10
voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen van de - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 11
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. Customer self repair 11 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 12
Customer self repair 12 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 13
Customer self repair 13 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 14
Customer self repair 14 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 15
Illustrated parts catalog Storage blade components For up-to-date spare parts information, see either of the following websites: • HP PartSurfer website (http://partsurfer.hp.com/search.aspx) • HP Parts Store website (http://h20141.www2.hp.com/Hpparts/Default.aspx) Item Description 1 FBWC - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 16
d) 200-GB, SATA, MLC, SFF, 3G e) 400-GB, SATA, MLC, SFF, 3G Spare part number 685035-001 670033-001 - 685034-001 - 653950-001 653953-001 653954-001 653955-001 653956- HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 17
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Obligatorio-componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendr - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 18
Illustrated parts catalog 18 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 19
from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel. This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To reduce the risk - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 20
. However, it may be necessary to leave the D2220sb powered up when performing other operations, such as hot-plug installations or troubleshooting. Storage blade preparation Servicing internal storage blade components To service any internal D2220sb component, do the following: 1. Power down the - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 21
a full-height server blade, do one of the following: o Remove the blank installed above the D2220sb. o Remove the half-height device installed above the D2220sb. For information about removing a half-height device, see the half-height device user guide. 4. Remove the D2220sb: Removal and replacement - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 22
with a half-height server blade o Partnered with a full-height server blade 5. Place the D2220sb on a flat, level work surface. Avoiding equipment damage and data loss To avoid possible equipment damage and data loss when performing service on the D2220sb, remove the following components and - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 23
servicing the D2220sb before beginning any installation storage blade shutdown, close the drive drawer immediately. When the drives reach critical temperatures, the system shuts down. 1. Back up all data on the D2220sb. 2. Power down the partner server blade (on page 21). 3. Remove the D2220sb - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 24
it was removed. 7. Place the drives in a static-free environment. When the service procedures are complete, return each drive to the bay in the drive drawer from electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. Removal - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 25
and improper cooling that can lead to thermal damage. To remove the component: 1. Back up all data on the D2220sb. 2. Power down the partner server blade (on page 21). 3. Remove the D2220sb (on page 21). 4. Remove the access panel (on page 26). 5. Open the drive drawer. Extend the drawer to gain - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 26
When the service procedures are complete, install the module by reversing the removal procedure. server blade (on page 21). 2. Remove the D2220sb (on page 21). 3. Press the access panel release button. 4. Slide the access panel toward the rear of the D2220sb. 5. Remove the access panel. Install the - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 27
and flash (2 per second)-To avoid drive damage or data loss and storage blade shutdown, close the drive drawer immediately. When the drives reach critical temperatures, electrical components, properly ground the D2220sb before beginning any installation procedure. Improper grounding can cause ESD. - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 28
improper cooling and thermal damage, do not operate the D2220sb or the enclosure unless the first drive bay is populated beep and flash (2 per second)-To avoid drive damage or data loss and storage blade shutdown, close the drive drawer immediately. When the drives reach critical temperatures, the - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 29
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating the D2220sb in this manner results in improper airflow and improper - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 30
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating the D2220sb in this manner results in improper airflow and improper - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 31
board. The drive drawer and cable spool are not shown for clarity. IMPORTANT: To avoid possible damage to the D2220sb, be sure that the FBWC module is fully seated before installing the retaining screw. To replace the component, reverse the removal procedure. Front panel WARNING: To reduce the risk - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 32
: To prevent damage to electrical components, properly ground the D2220sb before beginning any installation procedure. Improper grounding can cause ESD. To remove the component: 1. Power down the partner server blade (on page 21). 2. Remove the D2220sb (on page 21). 3. Remove the front panel ("Front - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 33
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating the D2220sb in this manner results in improper airflow and improper - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 34
-through cable cover from the drive drawer. CAUTION: The pass-through cable is under tension. Hold the end of the cable firmly when removing, and guide the cable back to the coiled position in the chassis. 9. Remove the pass-through board and cable from the drive drawer. 10. Remove the capacitor - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 35
CAUTION: To avoid damage to the cable spool guides, do not pull them outwards. 11. To remove the pass-through cable from the carrier, pull the cable spool guides toward you with both index fingers, and then push the cable spool away from you with both thumbs. Removal and replacement procedures 35 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 36
the chassis support rail. 3. Install the pass-through board and cable in the drive drawer. 4. Install the capacitor cover. 5. Install the pass-through cable cover on the drive drawer. 6. Install the FBWC module. 7. Install the FBWC capacitor pack. 8. Install the access panel. 9. Install all drives - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 37
10. Install the storage blade. 11. Power up the partner server blade. After you replace the system board. To remove the component: 1. Back up all data on the D2220sb. 2. Power down the partner server blade (on page 21). 3. Remove the D2220sb (on page 21). 4. Remove all drives ("Remove the drives" - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 38
-through cable cover from the drive drawer. CAUTION: The pass-through cable is under tension. Hold the end of the cable firmly when removing, and guide the cable back to the coiled position in the chassis. 7. Remove the pass-through board and cable from the drive drawer. Removal and replacement - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 39
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating the D2220sb in this manner results in improper airflow and improper - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 40
You do not need to remove the remaining slide assembly from the chassis or either slide assembly from the drive drawer. 8. Remove the failed enclosure release latch assembly. To replace the component, reverse the removal procedure. Removal and replacement procedures 40 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 41
power-up. HP Insight Diagnostics HP Insight Diagnostics is a proactive server blade management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server blade installations, troubleshoot problems, and - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 42
downtimes • Rich configuration history • Health and service alerts • Easy export and upload to Service and Support The HP Active Health System monitors and records changes in the server hardware and system configuration. The Active Health System assists in diagnosing problems and delivering rapid - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 43
/download). The Active Health System log can be downloaded manually from iLO 4 or HP Intelligent Provisioning and sent to HP. For more information, see the HP iLO User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs). Integrated Management Log The IML - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 44
Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language: • English (http://www.hp.com/support - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 45
Item Description 1 Product information tag 2 Hot-plug drive drawer release button 3 Hot-plug drive drawer handle 4 Storage blade release latch 5 Storage blade release button* * Removing the storage blade from the enclosure removes power from the drives. Component identification 45 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 46
and reinstalled. If the LED continues to flash for more than 2 minutes, there is a fault. Make sure the partner server blade is powered down before the storage blade is installed. Drive drawer open alarm Slow beep (every 5 seconds)-The drive drawer is open, and drives are not fully protected by - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 47
immediately to avoid drive damage or data loss and storage blade shutdown. The Health status LED bar turns green identified by a host application. The drive carrier firmware is being updated or requires an update. Rotating drive is not configured and predicts the drive will fail. Solid amber The drive - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 48
corresponds to a pressure minimum of 70 KPa. † Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Storage blade specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 5.56 cm (2.19 in) 50.95 cm (20.06 in) 18.16 cm (7.15 in) 5.0 kg (11 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 49
Acronyms and abbreviations ACU Array Configuration Utility CSR Customer Self Repair ESD electrostatic discharge FBWC flash-backed write cache HP SIM HP Systems Insight Manager iLO 4 Integrated Lights-Out 4 IML Integrated Management Log SAS serial attached SCSI SATA serial ATA SFF small form factor - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 50
documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:[email protected]). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 50 - HP D2220sb | HP D2220sb Storage Blade Maintenance and Service Guide - Page 51
LEDs 46 HP Insight Diagnostics 41, 42 I illustrated parts catalog 15 Insight Diagnostics 41, 42 installing the access part numbers 15 powering down 21 preparation procedures problem diagnosis 44 20, 22 R removal and replacement procedures 19 removing the access panel 26 removing the storage blade
HP D2220sb Storage Blade
Maintenance and Service Guide
Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and
software.
Part Number: 714240-001
February 2013
Edition: 1