HP D2D2502i HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ
HP D2D2502i Manual
View all HP D2D2502i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D2D2502i manual content summary:
- HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 1
HP StoreOnce B6200 Backup System Installation Planning and Preparation Guide nl and Checklists (chapter 6) Abstract This guide is intended for customers so that they can prepare for HP service specialists to install the HP StoreOnce Backup System. It will help them ensure that all environmental and - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP 3.6.0 version of HP StoreOnce software. It has been amended to describe supported network bonding modes. - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 3
HP StoreOnce B6200 Backup System 5 Warnings and cautions...6 2 Product specifications 8 Product dimensions...8 Product weight...8 Power/PDU requirements...9 Power specification...9 PDU options...10 3 Connecting to your network 12 What is currently supported ...12 What is not currently supported - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 4
Documentation feedback...31 4 Contents - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 5
1 The HP StoreOnce B6200 Backup System An HP service specialist will install the HP B6200 Backup System. It is supplied partially configured and is made up as follows: • One or two HP B6000 Extended Rack Assemblies with stabilizers • The rack contains at least one base couplet (consisting of two - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 6
handle the product. However, should this prove necessary, care must be taken to avoid damage to people and equipment. For this reason, safety and handling instructions are included below. Be sure to read them if you need to move or 6 The HP StoreOnce B6200 Backup System - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 7
To reduce the risk of personal injury or damage to the equipment, before installing equipment be sure that: • The leveling jacks are extended to the floor are needed to safely unload a rack from a pallet. The weight of an HP B6000 rack can be between that of a Single Couplet Rack (281 kg) and a - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 8
240mm deeper than a standard depth rack. Table 1 Physical dimensions Rack Shipping 218 cm x 146 cm x 86 cm (h x d x w) nl 85.80 x 57.50 x 33.90 inches Installed 200 cm x 124 cm x 61 cm (h x d x w) nl 78.80 x 50.50 x 23.60 inches Product weight The weight varies depending upon the number of racks - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 9
for each couplet. But it is strongly recommended that each rack be installed with four outlets to allow for ease of expansion, even if the 25851.71 44324.48 Table 8 Power specification at 240V, single rack installed Single rack configuration 1 couplet with minimum storage 1 couplet with maximum - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 10
9 Power specification at 240V, both racks installed 2-rack configuration 3 couplets with minimum storage HP B6200 Backup System is available with the following power options. IMPORTANT: You must specify which power option will be used before placing the order for the HP StoreOnce Backup system - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 11
Figure 4 Dual and Quad Modular PDU part numbers Power/PDU requirements 11 - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 12
network configurations for each rack in a two-rack system. What is not currently supported • IPv6 is not supported. • DHCP is not supported. • There is no VTL support on Ethernet using the iSCSI protocol. Factory default cabling The HP B6200 Backup System contains an internal 10GbE and 1 GbE private - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 13
you have installed. • It is strongly recommended that you allocate sufficient IP addresses to support a fully expanded two-rack system (with 8 backup targets and replication configurations. Physical IP ports • The physical ports are the ports that are used to connect the HP StoreOnce Backup System - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 14
backup targets, VTL and NAS replication configurations and Catalyst copy jobs (the data path VIFs). You will not know what these addresses are until the HP service engineer has configured the network for you. The HP service engineer will leave you with a record of these addresses after installation - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 15
StoreOnce CLI): • No external gateways: If the customer wants to use the HP StoreOnce B6200 Backup System in a totally isolated network environment, they should not configure an external gateway (the HP support only and for software revision 3.3.0 and to allow the user to specify a gateway for - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 16
configure a gateway. NOTE: For software revision 3.3.0 and greater: if the couplets that you have installed. In the following examples backup and replication targets. Reserved IP address range The HP StoreOnce Backup System and 1 GbE sub-nets Template 1 supports users who have a 10GbE network and a - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 17
should not be disconnected. Template 2, uses 1GbE network only Template 2 supports users who have a 1GbE network only. The same network is used data. NOTE: For software revision 3.3.0 and greater: customers who do not have a sufficient number of physical Ethernet ports to support Template 2 should - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 18
site replication traffic. supports users who want to have only two 1GbE network connections from each node in a couplet to their Ethernet switches. The same network is used for data and management. It is primarily for customers who only use VTL as their backup targets and do not use StoreOnce - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 19
configuration process and allocate a range sufficient for all IPs required by the system. Any IP addresses that have been assigned to the nodes during the Data IP addresses will change and you will need to reconfigure backup targets and replication. (You will not lose any data.) The following table - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 20
external switches are used, these switches must support a Multi Chassis Link Aggregation protocol that is Spec for example HP cables Or: Optical 10GbE SFP+ devices (HP P/N 455883-B21) NOTE: When using the 10GbE network, Templates 1 or 3, no SFPs are provided as part of the standard installation - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 21
ports for each template The number of physical connections that are required varies depending upon the template selected and the number of couplets in the system. This number should not be confused with the number of IP addresses required. Table 12 Number of physical network ports required Template - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 22
in switch or fabric zoning that will negate the failover capabilities of the HP B6200 Backup System and its autonomic restart ability. NOTE: Only two ports are available when using software revisions prior to 3.9.0. Upgrading to 3.9.0 or greater, will automatically give you functionality to use all - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 23
install and configure the system. All other tools are provided by the HP service specialist. Related information The following HP StoreOnce Backup System documentation is available. • HP StoreOnce B6200 Backup system User Guide • HP StoreOnce Backup system CLI Reference Guide • HP StoreOnce Backup - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 24
the system they should have as part of the planning process. In particular, will the HP StoreOnce Backup system be added to an Active Directory Domain? With StoreOnce software v3.9.0 and later, it is possible to add external users or groups that contain AD domain users. 24 Preparing for installation - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 25
• Prepared the environment and the information that the service specialist requires to install and configure your system NOTE: An electronically fillable version of this section is available for this product from http:// www.hp.com/support/manuals. Customer details Table 13 Customer details Customer - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 26
upgrades and licenses • Replication and Catalyst licenses • Security license (available with StoreOnce software v3.9.0 and later) • Couplet(s) to be installed can support the HP B6200 Backup System's input power and power outlet requirements. The AC power input for the HP B6200 Backup System has - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 27
application that supports path failover. (StoreOnce VTL replication uses the Ethernet connectivity.) Please note that the HP Data Protector DFMF (Distributed File Media Format) for Data Protector's virtual full backups is not supported for use with the B6000 StoreOnce Backup System. This format - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 28
software revision 3.3.0 and greater. IMPORTANT: It is essential that the information in the following checklist is completed and given to HP Support Services prior to the install. The installation values that will allow you to expand your system without the need to reconfigure the network. For - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 29
HP service specialist will provide you with a record of the Virtual IP addresses after the network configuration has been completed. These are the addresses that you need to connect to the B6000 Management Console (from the GUI or CLI) and to configure backup and replication The installation requires - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 30
supports failover. See Fibre Channel connection (page 22). Miscellaneous If NTP, email and SNMP requirements are specified prior to installation, the HP service specialist may be able to help you configure your system. 1. NTP is recommended for time synchronization, for example when replicating - HP D2D2502i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 31
• HP StoreOnce Backup System CLI Reference Guide: This guide contains a list of the available CLI commands with instructions on using them. • HP StoreOnce B6200 Backup System User Guide: This guide contains detailed information on using the Web Management Interface. It also contains troubleshooting
HP StoreOnce
B6200 Backup System
Installation Planning and Preparation Guide
nl
and Checklists (chapter 6)
Abstract
This guide is intended for customers so that they can prepare for HP service specialists to install the HP StoreOnce Backup
System. It will help them ensure that all environmental and networking prerequisites are in place before HP service specialists
arrive to install the product and carry out the initial configuration. This document assumes that the product has not yet been
delivered. It does not describe the actual installation and configuration steps.
Please read this document and complete the checklists at the end of it before the HP service engineer arrives to install the HP
StoreOnce B6200 Backup System. The checklists are also available as a form-fillable Word document.
HP Part Number: EJ022-90995
Published: October 2013
Edition: 7