HP D2D2504i HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ
HP D2D2504i Manual
View all HP D2D2504i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D2D2504i manual content summary:
- HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 1
HP StoreOnce B6200 Backup System Installation Planning and Preparation Guide nl and Checklists (chapter 6) Abstract This guide is intended for customers so that they can prepare for HP service specialists to install the HP StoreOnce Backup System. It will help them ensure that all environmental and - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP 3.6.0 version of HP StoreOnce software. It has been amended to describe supported network bonding modes. - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 3
HP StoreOnce B6200 Backup System 5 Warnings and cautions...6 2 Product specifications 8 Product dimensions...8 Product weight...8 Power/PDU requirements...9 Power specification...9 PDU options...10 3 Connecting to your network 12 What is currently supported ...12 What is not currently supported - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 4
Documentation feedback...31 4 Contents - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 5
shelves may be installed per couplet). Figure 1 Base couplet NOTE: • The HP B6200 Backup System can only be installed in an HP B6000 rack. • An HP B6000 rack should only be used for HP B6200 Backup Systems and supported storage expansion shelves. • Do not plan to install additional units, such as - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 6
handle the product. However, should this prove necessary, care must be taken to avoid damage to people and equipment. For this reason, safety and handling instructions are included below. Be sure to read them if you need to move or 6 The HP StoreOnce B6200 Backup System - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 7
of personal injury or equipment damage when unloading a rack: • At least two people are needed to safely unload a rack from a pallet. The weight of an HP B6000 rack can be between that of a Single Couplet Rack (281 kg) and a fully configured 2 Couplet rack (764 kg). It can stand more than - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 8
2 Product specifications Product dimensions Note that this product is provided in extended racks: an installed depth of 1240 mm (50.50 inches) is required. This is 240mm deeper than a standard depth rack. Table 1 Physical dimensions Rack Shipping 218 cm x 146 cm x 86 cm (h x d x w) nl 85.80 x 57. - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 9
Table 5 Weight specifications with modular PDUs, Rack 2 Single couplet Single couplet with maximum storage added Two couplets Two couplets with maximum storage added to couplets 24A and 32A kgs lbs 291.06 640.19 471.06 1036.19 409.60 900.98 771.60 1697.38 40A kgs lbs 274.74 604.18 - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 10
.96 9677.81 7439.38 12544.50 BTU/hour 20406.86 34261.44 25823.15 44295.92 PDU options NOTE: HP recommends using one of the Monitored PDU options. The HP B6200 Backup System is available with the following power options. IMPORTANT: You must specify which power option will be used before placing the - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 11
Figure 4 Dual and Quad Modular PDU part numbers Power/PDU requirements 11 - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 12
network configurations for each rack in a two-rack system. What is not currently supported • IPv6 is not supported. • DHCP is not supported. • There is no VTL support on Ethernet using the iSCSI protocol. Factory default cabling The HP B6200 Backup System contains an internal 10GbE and 1 GbE private - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 13
Backup System to the customer's network. • Two 10GbE and four 1GbE ports are available on each node for connecting to the customer's Ethernet network(s). • Physical ports are always bonded and a physical IP address is required for each external bonded Ethernet port. Once the HP service engineer - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 14
address of the service set, allowing hosts and the B6000 Backup System to function correctly. Each couplet has two nodes and, therefore, two service sets, which configured at installation by the HP Support specialist. Three bonding modes are supported: • Mode 1 (Active/Backup) This is the most simple - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 15
StoreOnce CLI): • No external gateways: If the customer wants to use the HP StoreOnce B6200 Backup System in a totally isolated network environment, they should not configure an external gateway (the HP support engineer will simply skip this step during configuration) • One external gateway: This - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 16
reconfigure the addresses used for backup and replication targets. Reserved IP address range The HP StoreOnce Backup System uses the 10.154.x.x ip .x.x ip range. Template 1, uses 10 GbE and 1 GbE sub-nets Template 1 supports users who have a 10GbE network and a 1GbE network and wish to use separate - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 17
to customer's management sub-net See Factory default cabling (page 12). These should not be disconnected. Template 2, uses 1GbE network only Template 2 supports users who have a 1GbE network only. The same network is used for data and management. The default bonding mode for this template is Mode - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 18
These should not be disconnected. Template 4, uses two 1GbE networks Template 4 supports users who have two 1GbE networks. One 1 GbE network is used for management. It is primarily for customers who only use VTL as their backup targets and do not use StoreOnce Catalyst stores or NAS CIFS/NFS shares - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 19
As long as sufficient IP addresses are allocated during the network configuration process, the B6000 Backup System will automatically assign IP addresses for all the nodes in the system when the network is initially configured and, subsequently, when additional couplets are added. If sufficient - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 20
and 4) and multiple external switches are used, these switches must support a Multi Chassis Link Aggregation protocol that is compatible with the rest infrastructure. For more information, see the white paper at http://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-4841ENW.pdf. • When using a 10GbE network - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 21
ports for each template The number of physical connections that are required varies depending upon the template selected and the number of couplets in the system. This number should not be confused with the number of IP addresses required. Table 12 Number of physical network ports required Template - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 22
HP B6200 Backup System and its autonomic restart ability. NOTE: Only two ports are available when using software revisions prior to 3.9.0. Upgrading are not supported. For a full list see http://www.hp.com/go/ebs. • Use WWPN zoning (rather than port based). This keeps the backup/restore environment - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 23
and StoreOnce Catalyst worked examples • HP StoreOnce Software Release Notes To locate the HP StoreOnce B6200 Backup System documents, go to http://www.hp.com/go/ storeonce, and then click the support link. Licenses Licenses are required for Capacity upgrades and StoreOnce features, replication and - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 24
. It is good practice to determine what other users will be required and what access to the system they should have as part of the planning process. In particular, will the HP StoreOnce Backup system be added to an Active Directory Domain? With StoreOnce software v3.9.0 and later, it is possible to - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 25
service specialist requires to install and configure your system NOTE: An electronically fillable version of this section is available for this product from http:// www.hp.com/support/manuals to boxes or components. Purchase information Products Purchased Count Capacity Customer details 25 - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 26
Note any requirements for: • Capacity upgrades and licenses • Replication and to each other, to ensure there are no problems with cable lengths. • Appropriate power, air support the HP B6200 Backup System's input power and power outlet requirements. The AC power input for the HP B6200 Backup System - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 27
backups is not supported for use with the B6000 StoreOnce Backup System. This format is very inefficient with deduplication devices. For further details see HP StoreOnce Backup system service set (node). 1. Do you intend to create virtual tape libraries as backup targets (FC only Which backup - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 28
following checklist is completed and given to HP Support Services prior to the install. The installation select the network bonding mode nl (1 = Active/Backup; 4 = IEEE 802.3ad Dynamic Link Aggregation; values that will allow you to expand your system without the need to reconfigure the network. For - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 29
IMPORTANT: Your HP service specialist will provide you with a record of the Virtual IP addresses after the network configuration has been completed. These are the addresses that you need to connect to the B6000 Management Console (from the GUI or CLI) and to configure backup - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 30
Tape Libraries (VTL) and the configuration supports failover. See Fibre Channel connection (page 22). Miscellaneous If NTP, email and SNMP requirements are specified prior to installation, the HP service specialist may be able to help you configure your system. 1. NTP is recommended for time - HP D2D2504i | HP StoreOnce B6200 Installation Planning and Preparation Guide (EJ - Page 31
B6200 Backup System User Guide: This guide contains detailed information on using the Web Management Interface. It also contains troubleshooting information, including details on replacing failed or failing hard disks. You can find these documents from the Manuals page of the HP Business Support
HP StoreOnce
B6200 Backup System
Installation Planning and Preparation Guide
nl
and Checklists (chapter 6)
Abstract
This guide is intended for customers so that they can prepare for HP service specialists to install the HP StoreOnce Backup
System. It will help them ensure that all environmental and networking prerequisites are in place before HP service specialists
arrive to install the product and carry out the initial configuration. This document assumes that the product has not yet been
delivered. It does not describe the actual installation and configuration steps.
Please read this document and complete the checklists at the end of it before the HP service engineer arrives to install the HP
StoreOnce B6200 Backup System. The checklists are also available as a form-fillable Word document.
HP Part Number: EJ022-90995
Published: October 2013
Edition: 7