HP D2D4106i HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8
HP D2D4106i Manual
View all HP D2D4106i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D2D4106i manual content summary:
- HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 1
HP StoreOnce Backup System Linux and UNIX Configuration Guide for G3 multinode and single node appliances HP Part Number: BB852-90943 Published: May 2013 Edition: Edition 3.0 - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 3
to configure the Open-iSCSI module using the D2Dsetup script 7 How to configure the Open-iSCSI module manually using the command line 8 Configuring the HP StoreOnce Backup System for Fibre Channel 9 Configuring the HP StoreOnce Backup System for NAS (NFS 10 Controlling an iSCSI or Fibre Channel - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 4
Solaris kernel (NAS 35 Restore the Solaris kernel (NAS 35 About this guide 36 Intended audience...36 Related documentation...36 Document conventions and symbols 36 HP technical support...37 Product warranties...37 Subscription service...37 HP websites...38 Documentation feedback...38 4 Contents - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 5
devices. For specific details of the VTL, Catalyst and NAS device options available, please refer to the HP StoreOnce Backup System User Guide for your product. NAS targets for backup applications Support for both CIFS and NFS protocols means that NAS target devices may be created as backup targets - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 6
) is installed and configured initially by HP Support engineers. For the single node products, HP StoreOnce 2620, 42xx and 44xx Backup systems, please refer to the HP StoreOnce Backup System Installation and Configuration guide for instructions on network configuration and getting started. This - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 7
Server 11 (x64 and IA64) • RedHat Enterprise Linux 5 (x86, x64 and IA64) • RedHat Enterprise Linux 6 (x64) NOTE: HP StoreOnce Backup Systems with iSCSI interfaces are only supported with SuSE Linux Enterprise Server 10 SP1 or greater and RedHat Enterprise Linux 5 or greater. Always refer to http - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 8
be found in the iscsiadm(8) man documents. The following instructions guide the user through the following steps required to connect a Linux host to an HP StoreOnce Backup System. • Discover iSCSI target devices on the HP StoreOnce Backup System • Configure CHAP authentication • Configure automatic - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 9
reboots, the open-iscsi service must be configured to system, including the HP StoreOnce Backup System. An example output would be HP Model: Ultrium 3-SCSI Rev: pc81 Type: Sequential-Access ANSI SCSI revision: 03 Configuring the HP StoreOnce the GUI for an HP StoreOnce B6200 Backup System is shown - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 10
the HP StoreOnce Backup System for NAS (NFS) IMPORTANT: SuSE Linux Enterprise Server 10 and Red Hat Advanced Server 5 do not have support for StoreOnce Downloads page to acquire the patch file, the appropriate instructions in the release notes, and any associated customer advisory. The StoreOnce - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 11
.141) Controlling an iSCSI or Fibre Channel HP StoreOnce Backup System using Linux The HP StoreOnce Backup System can appear to the Linux operating system as one of many supported emulation types. Refer to your product's user guide for supported emulation types. The robotics within the autoloader - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 12
slots within the library. Storage element 25 represents the import/export slot of the library, also known as the Mail Slot in the HP StoreOnce Backup System Web Management Interface. Loading a cartridge into a library tape drive To load a cartridge into the tape drive, the mtx load command should - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 13
25 1 Backup and restore files using TAR in Linux This section describes how to perform a simple backup and recovery of files to an HP StoreOnce Backup System using the console applications MTX and TAR. In the examples, the autoloader robotics is controlled using generic SCSI device file sg2 and - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 14
Back up the Linux kernel (iSCSI and Fibre Channel) 1. Check to see what media is available. localhost:~ $ mtx -f /dev/sg2 status Storage Changer /dev/sg2:1 Drives, 24 Slots ( 1 Import/Export ) Data Transfer Element 0:Empty Storage Element 1:Full :VolumeTag=72255101 Storage Element 2:Full :VolumeTag= - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 15
to the temporary folder. localhost:~ $ tar xvf /kernel.tar NOTE: is the path to the NFS share configured on the StoreOnce appliance. 3. Compare the original Linux kernel with the restored Linux kernel. localhost:~ $ cmp /boot/vmlinux* /temp/boot/vmlinux* If no differences - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 16
HP-UX 11i v2. See Using large block sizes with HP-UX 11i V2 (page 23). Configuring the HP StoreOnce Backup System for iSCSI If your product supports to the Download Software column), click on Installation Instruction to download instructions for using the Software Distributor tool to install the - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 17
man documents. The following instructions provide the minimum steps required to connect an HP-UX host to an HP StoreOnce Backup System. 1. HP StoreOnce Backup System web management interface when manually configuring library devices. 3. To discover available iSCSI target devices on a HP StoreOnce - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 18
-pO The output will be similar to this: Operational Target Information Target # 1 ----------- Target Name : iqn.1986- 03.com.hp:storage.d2d.cr209107ff.500110a6656e596f.library1 .drive1 Target Alias : No. of Target Addresses : 1 Target Address # 1 IP Address : x.x.x.x iSCSI TCP - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 19
, items in parentheses are user-defined strings. Substitute the appropriate information for , and . Once the HP StoreOnce Backup System has been modified, the operating system should be modified as follows: # iscsiutil -t authmethod CHAP None # iscsiutil - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 20
&T, best density available Berkeley, best density available AT&T, best density available Berkeley, no rewind, best density available Configuring the HP StoreOnce Backup System for Fibre Channel For a Switched Fabric Configuration, zone the individual devices to the host concerned using the virtual - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 21
for details of the GUI specific to your product, please refer to the product's User Guide. Output needs checking. 1. To discover operational target devices, type the following: # ioscan target devices, type the following: # insf Configuring the HP StoreOnce Backup System for Fibre Channel 21 - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 22
available Configuring the HP StoreOnce Backup System for NAS (NFS) The StoreOnce Backup System NAS interface should be configured to use NFS as the Access Protocol when backing up data using HP-UX. Once configured, the Network Path is displayed. The StoreOnce Backup System supports NFSv3 protocol - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 23
can be controlled from the console using a command called MC. The complete MC manual can also be accessed using the command man mc. The following examples illustrate how to complete common tasks with the HP StoreOnce Backup System. • Review the media • Load a cartridge into the tape drive • Unload - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 24
slots within the library. The IE_slot_1 represents the import/export slot of the library, also known as the Mail Slot in the HP StoreOnce Backup System Web Management Interface. Loading a cartridge into a library tape drive To load a cartridge into the tape drive, the mc -s -d command should - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 25
D1 3. Ensure you are in the root directory. # cd / 4. Back up the HP-UX kernel using tar. # tar cvf /dev/rmt/1mnb ./stand/vmunix 5. Move the cartridge folder to restore the backup into. # mkdir temp # cd /temp 3. Restore the HP-UX kernel to the temporary folder. # tar xvf /dev/rmt/1mnb 4. Move the - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 26
-UX kernel (NAS) 1. Ensure you are in the root directory. localhost:~ $ cd / 2. Backup the HP-UX kernel using TAR. localhost :~ $ tar cvf /kernel.tar ./stand/vmunix Restore the HP-UX kernel (NAS) 1. Create a temporary folder to restore the backup into. localhost:~ $ mkdir temp localhost - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 27
StoreOnce Backup System for iSCSI If your product supports iSCSI use the information in this section to configure it. If your product does not support iSCSI, go to Configuring the HP Backup System for Fibre Channel (page 30). How to enable the iSCSI software initiator 1. Enable the iSCSI services - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 28
instructions for iscsiadm can be found in the iscsiadm man documents. The following instructions provide the minimum steps to connect a Solaris host to an HP StoreOnce name is required by the HP StoreOnce Backup System web management interface when manually configuring library devices. 2. Configure - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 29
configure CHAP authentication you should update the iSCSI Authentication details in the web management GUI, as shown below. Once the HP StoreOnce Backup System has been modified, the operating system should be modified as follows: # iscsiadm modify initiator-node --authentication CHAP # iscsiadm - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 30
of the GUI specific to your product, please refer to the product's User Guide. 1. To create generic devices drivers for the iSCSI target devices, using fp@0,0/ st@w500110a057bb1b32,0:cb Configuring the HP StoreOnce Backup System for NAS (NFS) The StoreOnce Backup System NAS interface should be - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 31
StoreOnce Backup System supports NFSv3 protocol. By the nature of NFS protocol, there is an element of randomness in the data transmission between the client and target device, in this case, the StoreOnce or Fibre Channel HP StoreOnce Backup System using Solaris The HP StoreOnce Backup System appears - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 32
. To verify the tape device file for the tape drive, the MT command should be used: # mt -f /dev/rmt/2cb status The output should be: HP Ultrium LTO 3 tape drive: sense key(0x6)= Unit Attention file no= 0 block no= 0 residual= 0 retries= 0 This indicates that the tape drive files are valid but - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 33
slots within the library. Storage element 25 represents the import/export slot of the library, also known as the Mail Slot in the HP StoreOnce Backup System Web Management Interface. Loading a cartridge into a library tape drive To load a cartridge into the tape drive, the mtx load command should - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 34
Back up the Solaris kernel (iSCSI or Fibre Channel) 1. Check to see what media is available. # mtx -f /dev/scsi/changer/c3t1d0 status Storage Changer /dev/scsi/changer/c3t1d0:1 Drives, 24 Slots ( 1 Import/Export ) Data Transfer Element 0:Empty Storage Element 1:Full :VolumeTag=72255101 Storage - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 35
the Solaris kernel to the temporary folder. localhost:~ $ tar xvf /kernel.tar 3. Compare the original Solaris kernel with the restored HP-UX kernel. localhost:~ $ cmp /platform/`arch -k`/kernel/sparcv9/unix /temptemp/platform/`arch -k`/kernel/sparcv9/unix If no differences are found - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 36
(2620, 42xx and 44xx products) • HP StoreOnce Backup System Installation and Configuration Guide (2620, 42xx and 44xx products) You can find these documents from the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals Search on the product name. Document - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 37
clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. HP technical support For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following - HP D2D4106i | HP StoreOnce Backup System Linux and UNIX Configuration guide (BB8 - Page 38
additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/go/ebs • http://www.hp.com/service_locator • http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make
HP StoreOnce Backup System
Linux and UNIX Configuration Guide for G3
multinode and single node appliances
HP Part Number: BB852-90943
Published: May 2013
Edition: Edition 3.0