HP EVA P6000 HP P6300/P6500 EVA Fibre Channel Controller Enclosure Replacement

HP EVA P6000 Manual

HP EVA P6000 manual content summary:

  • 1
  • 2
  • 3
  • 4

HP P6300/P6500 EVA Fibre
Channel Controller Enclosure
Replacement Instructions
© Copyright 2011 Hewlett-Packard Development Company, L.P.
First edition: May 2011
The information in this document is subject to change without notice.
Printed in Puerto Rico
www.hp.com
*593088-001*
About this document
For the latest documentation, go to
h
t
tp://w
w
w
.hp
.co
m/su
ppo
r
t/
man
uals
, and select your product.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.
WARRANTY STATEMENT: To obtain a copy of the warranty for this
product, see the warranty information website:
h
t
tp://w
w
w
.hp
.co
m/go/s
t
o
r
age
w
ar
r
an
t
y
Choosing a storage configuration
The P6300 EVA configuration details are:
Two HSV340 controllers per controller enclosure
Four SAS ports
Four 8 Gb FC ports per controller
1/10 (minimum/maximum) controller enclosures
8/120 (minimum/maximum) M6612 (LFF) disk drives
8/250 (minimum/maximum) M6625 (SFF) disk drives
The P6500 EVA configuration details are:
Two HSV360 controllers per controller enclosure
Eight SAS ports
Four 8 Gb FC ports per controller
2/20 (minimum/maximum) controller enclosures
8/240 (minimum/maximum) M6612 (LFF) disk drives
8/450 (minimum/maximum) M6625 (SFF) disk drives
Before you begin
Observe the following precautions when replacing a controller.
CAUTION:
HP recommends that you perform the replacement procedure
within seven minutes from when the controller is removed to
when it is replaced in the enclosure. Ensure all necessary parts
are available so the procedure can be completed without
interruption. Removing a controller module significantly changes
the air flow within the enclosure. Both controllers must be
installed for the enclosure to cool properly. If a controller fails,
leave it in place in the enclosure until a new module is available
to install. The enclosure could shut down due to overheating
unless the controller is replaced within the recommended seven
minutes.
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection. See the documentation that shipped with
your system for additional information.
Page 1