HP EVA P6550 HP Disk Drive Replacement Instructions (5697-1679, June 2012)
HP EVA P6550 Manual
View all HP EVA P6550 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP EVA P6550 manual content summary:
- HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 1
and can cause data loss. • Parts can be damaged by electrostatic discharge. Use proper antistatic protection. • Have a copy of the product user guide available for reference. You can download a copy of the user guide from the product support page on the HP website. Figure 1 (page 2) shows the - HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 2
disk enclosure used with the P63x0/P65x0 EVA. Figure 2 SAS SFF disk drive numbering Verifying system redundancy Before replacing a disk, examine the redundancy status of the entire storage system to ensure a disk can be removed without impacting data availability. 1. Open HP P6000 Command View and - HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 3
status indicators, or if HP P6000 Command View or your system monitoring tool indicates multiple hardware failures, contact HP support for assistance (http://www.hp.com/support). • Analyze all failure messages received. Error messages identify each disk drive by its rack, enclosure, bay, and UUID - HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 4
the disk and the level of storage system activity. If, after attempting to ungroup the disk, the Requested usage and Actual usage boxes do not display Ungrouped or the Migration progress box does not display 100%, contact your HP-authorized service representative for assistance. 7. Click Remove to - HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 5
grouping a new disk that might have the incorrect firmware on it, verify the Device Addition Policy and set it to manual if necessary: 1. In the HP P6000 Command View navigation pane, select the storage system. The Initialized Storage System Properties window opens. 2. Click System Options - HP EVA P6550 | HP Disk Drive Replacement Instructions (5697-1679, June 2012) - Page 6
: http://www.hp.com/support/manuals Click Disk Storage Systems under Storage, and then select your product under P6000/EVA Disk Arrays. If the disk is running an unsupported version of firmware, download the firmware from the following website and install it using the instructions included with the
HP Disk Drive Replacement
Instructions
Abstract
These instructions apply to Fibre Channel and SAS disk
drives.
© Copyright 2012 Hewlett-Packard Development Company, L.P.
Printed in Puerto Rico
*5697-1679*
HP Part Number: 5697-1679
Published: June 2012
Edition: 2
About this document
For the latest documentation, go to
h
t
tp://
w
w
w
.hp
.co
m/su
ppo
r
t/man
uals
, and select your
product.
The information contained herein is subject to change
without notice. The only warranties for HP products
and services are set forth in the express warranty
statements accompanying such products and services.
Nothing herein should be construed as constituting an
additional warranty. HP shall not be liable for technical
or editorial errors or omissions contained herein.
WARRANTY STATEMENT: To obtain a copy of the
warranty for this product, see the warranty information
website:
h
t
tp://w
w
w
.hp
.co
m/go/s
t
o
r
age
w
ar
r
an
t
y
Before you begin
Observe the following precautions when replacing the
disk drive:
•
Ensure you have a replacement part available
before removing the failed component. Removing
a component impacts cooling within the enclosure.
Use a drive blank if a new drive is not available.
•
HP recommends that the replacement drive
matches the capacity and speed of the original
drive. For example, if the original drive was a
300 GB, 15K RPM drive, the replacement would
be a 300 GB, 15K RPM drive.
•
P63x0 and P65x0 storage systems support SAS
disk drives with
EVA
on the front identification
label. Other SAS drives are not supported.
•
Do not remove more than one disk drive at a time
from the enclosure. Doing so would impact
cooling of the enclosure and can cause data loss.
•
Parts can be damaged by electrostatic discharge.
Use proper antistatic protection.
•
Have a copy of the product user guide available
for reference. You can download a copy of the
user guide from the product support page on the
HP website.
Figure 1 (page 2)
shows the numbering of Fibre
Channel disk drives in the disk enclosure used with
the EVA.
Page 1