HP GbE2c HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc
HP GbE2c - Blc Layer 2/3 Fiber SFP Option Manual
UPC - 808736802215
View all HP GbE2c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP GbE2c manual content summary:
- HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 1
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Reference Guide Part number: 437881-002 Second edition: December 2006 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP the U.S. and other countries. Cisco® is a registered trademark of Cisco Systems, Inc. and/or its affiliates - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 3
an IP address ...9 Establishing a Telnet connection...9 Establishing an SSH connection ...9 Accessing the switch ...10 Idle timeout ...11 Typographical conventions...11 ISCLI basics Introduction ...13 Accessing the ISCLI ...13 ISCLI Command Modes ...13 Global commands...14 Command line interface - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 4
...53 Information dump...54 Statistics commands Introduction ...55 Port Statistics ...55 802.1x statistics ...56 Bridging statistics ...58 Ethernet statistics ...58 Interface statistics ...60 Internet Protocol (IP) statistics ...61 Link statistics...62 Layer 2 statistics...62 FDB statistics ...62 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 5
configuration...107 Trunk configuration ...107 Layer 2 IP Trunk Hash configuration 108 Link Aggregation Control Protocol configuration 108 LACP Port configuration ...109 VLAN configuration...109 Layer 3 configuration ...110 IP interface configuration ...110 Default Gateway configuration ...111 IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 6
Tracking configuration 129 VRRP Interface configuration...130 VRRP Tracking configuration ...130 Quality of Service configuration...131 QoS 802.1p configuration...131 Access Control configuration ...131 Access Control List configuration ...131 ACL Ethernet Filter configuration ...132 ACL IP Version - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 7
...143 Downloading new software to the switch 143 Selecting a software image to run ...144 Uploading a software image from the switch 144 Selecting a configuration block ...145 Resetting the switch ...146 Accessing the AOS CLI ...146 Maintenance Commands Introduction ...147 System maintenance - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 8
the HP GbE2c Layer 2/3 Ethernet Blade Switch. The extensive switching software included in the switch provides a variety of options for accessing and configuring the switch: • Text-based command line interfaces (AOS CLI and ISCLI) for access via a local terminal or remote Telnet/Secure Shell (SSH - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 9
Once the IP parameters are configured, you can access the ISCLI using a Telnet connection. To establish a Telnet connection with the switch, run the Telnet program on the workstation and enter the telnet command, followed by the switch IP address: telnet You - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 10
the IP parameters are configured, you can access the ISCLI to enable SSH. To establish an SSH connection with the switch, run the SSH program on the workstation by issuing the ssh command, followed by the user account name and the switch IP address: >> # ssh @ - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 11
By default, the GbE2c disconnects the console, Telnet, or SSH session after five minutes of inactivity. This function is controlled by the idle timeout parameter, which can be set from 1 to 60 minutes. To change this parameter, see the "System configuration" section in the "Configuration Commands - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 12
italic text vertical line | Meaning Indicate optional elements in syntax descriptions. Do not type the brackets when entering the command. Example: If the command syntax is show ip interface [] Enter show ip interface or show ip interface 1 Indicates variables in command syntax descriptions - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 13
you reset the configuration to factory defaults. The CLI boot mode is not part of the configuration settings. ISCLI Command Modes The ISCLI has three major command modes, listed in order of increasing privileges, as follows: User EXEC mode: This is the initial mode of access. By default, password - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 14
Switch(config-ip-if)# Command used to enter or exit. Enter Interface IP Configuration mode, from Global Configuration mode: interface ip Exit to Global Configuration mode: exit Exit to Privileged EXEC mode: end Global commands Some basic commands are recognized throughout the ISCLI - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 15
available commands or options that begin with that letter. Entering additional letters further refines the list of commands or options displayed. If only one command fits the input text when you press the Tab key, that command is supplied on the command line, waiting to be entered. ISCLI basics 15 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 16
name • VLAN membership Command mode: All except User EXEC Displays GEA port mapping information, used by service personnel. Command mode: All Displays Uplink Failure Detection information. Command mode: All Dumps all switch information available (10K or more, depending on your configuration). If - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 17
of the switch management processor • IP address of IP interface #1 • Hardware version and part number • Software image file and version number • Configuration name • Log-in banner, if one is configured Command mode: All Displays most recent syslog messages. Command mode: All Displays User Access - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 18
Protocol Description This is a string that represents the name of the user that you can use to access the switch. This indicates whether messages sent on behalf of this user are protected from disclosure using a privacy protocol. GbE2c software supports DES algorithm for privacy. The software also - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 19
system provides authorization services. The vacmAccessTable maps a group name, security information, a context, and a message type, which could be the read or write type of operation or notification into a MIB view. The View-based Access Control Model defines a set of services that an application - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 20
, which represents the configuration. Displays the User Security Model (USM) user name. Displays the community tag. This tag specifies a set of transport endpoints from which a command responder application accepts management requests and to which a command responder application sends an SNMP trap - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 21
are used to select target addresses for a Target Parameters Table information The following command displays SNMPv3 target parameters information: show snmp-server v3 target-parameters Command mode: All Name MP Model User messages using this entry. The system may choose to return an inconsistentValue - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 22
displays the SNMPv3 Notify Table: show snmp-server v3 notify Command mode: All Name Tag v1v2trap v1v2trap The following table describes the SNMPv3 Notify Table information. entry is selected. If this entry contains a value of zero length, no entries are selected. Information Commands 22 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 23
displays SNMPv3 information: show snmp-server v3 Command mode: All Engine ID = 80:00:07:50:03:00:0F:6A:F8:EF:00 usmUser Table: User Name Protocol admin NO AUTH, NO PRIVACY adminmd5 HMAC_MD5, DES PRIVACY adminsha HMAC_SHA, DES PRIVACY v1v2only NO AUTH, NO PRIVACY vacmAccess Table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 24
information The following command displays system information: show sys-info Command mode: All System Information at 6:56:22 Thu Jan 11, 2006 Time zone: America/US/Pacific GbE2c Ethernet Blade Switch for HP c-Class Blade System sysName: sysLocation: RackId: Default RUID RackName: Default Rack Name - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 25
System user information The following command displays user status information: show access user Command mode: All except User EXEC Usernames: user - enabled oper - disabled admin - Always Enabled Current User ID table: 1: name tech1 , ena, cos user 2: name tech2 , ena, cos user , password - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 26
of the oper (operator) access level. admin Displays the status of the admin (administrator) access level. Current User ID Table Displays the status of configured user IDs. To configure new user IDs, use the /cfg/sys/access/user/uid command. Layer 2 information The following table describes the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 27
Table 17 Layer 2 information commands Command show vlan information show layer2 Usage Displays VLAN configuration information, including: • VLAN Number • VLAN Name • Status • Port membership of the VLAN Command mode: All Dumps all switch information available from Layer 2 memory (10K or more, - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 28
02:01:00:00:0c VLAN ---- 300 300 300 configuration" section in the "Configuration Commands" chapter. Link Aggregation Control Protocol information The following table describes the Link Aggregation Control Protocol information commands. Table 19 LACP information commands Command show interface - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 29
mode: All >> LACP# dump port lacp adminkey operkey selected prio attached trunk aggr 1 off 1 1 n 32768 -- -- 2 off 2 2 n 32768 -- -- LACP dump includes the following information for each port in the GbE2c Ethernet Blade switch: • lacp-Displays the port's LACP mode (active, - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 30
displays 802.1x information: show dot1x information Command mode: All System capability : Authenticator System status : disabled Protocol version : 1 Authenticator Backend Port Auth Mode Auth Status PAE State Auth State 1 force-auth unauthorized initialize initialize 2 force-auth - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 31
Command mode: All upfast disabled, update 40 Spanning Tree Group 1: On (STP/PVST+) VLANs * FORWARDING * FORWARDING * The switch software uses the IEEE 802.1d to seeing if STP is enabled or disabled, you can view refer to the following port-specific STP information: Information Commands 31 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 32
The current root port refers to the port on the switch that receives data from the root bridge transmits a configuration bridge protocol data unit (BPDU bridge waits without receiving a configuration bridge protocol data unit before to each port, if applicable. Information includes the priority - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 33
command displays RSTP/MSTP information: show spanning-tree stp information Command mode: All upfast disabled, update 40 Spanning Tree Group 1: On (RSTP) VLANs ---- P2P2,Edge P2P The switch software can be set to • Aging time You can also refer to the following port-specific RSTP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 34
refers to the port on the switch configuration Backup (BKUP), Master (MAST), or Unknown (UNK). Shows information about the bridge connected to each port, if applicable link connected to the port, and whether the port is an edge port. Link type values are AUTO, P2P, or SHARED. Information Commands 34 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 35
Command mode: All Mstp Digest: 0xac36177f50283cd4b83821d8ab26de62 Common Internal Spanning Tree: VLANs if Common Internal Spanning Tree (CIST) is enabled or disabled, you can view the following CIST bridge • Forwarding delay • Hops You can also refer to the following port-specific CIST information: - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 36
edge port. Link type values are AUTO, P2P, or SHARED. Trunk group information The following command displays Trunk Group information: show portchannel information Command mode: All Trunk group 1, Enabled port state: 17: STG 1 forwarding 18: STG 1 forwarding When trunk groups are configured, you can - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 37
Displays VLAN information Command mode: All Displays VLAN information, including spanning tree assignment. Command mode: All The following command displays VLAN information: show vlan Command mode: All VLAN ---1 2 7 11 14 15 16 17 18 19 20 21 22 24 300 4000 4095 Name Status Default VLAN - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 38
configuration). If you want to capture dump data to a file, set your communication software on your workstation to capture session data prior to issuing the dump commands. Command mode: All except User EXEC * indicates commands that are available only on the GbE2c Layer 2/3 Ethernet Blade Switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 39
Table 27 Route Information commands Command show ip route Usage Displays all routes configured in the switch. Command mode: All except User EXEC Show all IP Route information The following command displays IP route information: show ip route Command mode: All except User EXEC Status code: * - - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 40
the Address Resolution Protocol commands. Table 30 ARP information Command show ip arp find show ip arp interface show ip arp vlan show ip arp show ip arp reply Usage Displays a single ARP entry by IP address. Command mode: All except User EXEC Displays the ARP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 41
on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the OSPF commands. Table 32 OSPF information commands Command show ip ospf general-information show ip ospf area information [] show ip ospf interface [] show ip ospf area-virtual-link information show ip ospf - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 42
OSPF interface information NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following command displays OSPF interface information: show ip ospf interface [] Command mode: All except User EXEC Ip Address 10.10.12.1, Area 0.0.0.1, Admin Status UP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 43
OSPF Database information NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the OSPF Database information commands. Table 33 OSPF Database information commands Command Usage show ip ospf database advertising-router Takes - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 44
ip rip Usage Displays RIP routes. Command mode: All except User EXEC Displays RIP interface information. Command mode: All except User EXEC Displays RIP user's configuration. Command mode: All RIP Routes information NOTE: RIP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 45
only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following command displays RIP user information: show interface ip [] rip Command mode: All RIP USER CONFIGURATION : RIP on updat 30 RIP Interface 2 : 102.1.1.1, enabled version 2, listen enabled, supply enabled, default none poison - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 46
groups learned by the switch. Command mode: All except User EXEC VRRP information Virtual Router Redundancy Protocol (VRRP) support on GbE2c Ethernet Blade switch provides redundancy between routers in a LAN. This is accomplished by configuring the same virtual router IP address and ID number - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 47
Field Priority Cosq Weight Description Displays the 802.1p Priority level. Displays the Class of Service queue. Displays the scheduling weight of the COS queue. The following table 802.1p Priority level. Displays the Class of Service queue. Displays the scheduling weight. Information Commands 47 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 48
: show access-control Command mode: All Current ACL information: Filter 1 profile: Ethernet - VID : 1/0xfff Actions : Set COS to 0 Filter 2 profile: Ethernet - VID : 1/0xfff Actions : Permit No ACL groups configured. ACL information provides configuration parameters for each - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 49
the number of granted buckets that may hold sampled data. RMON alarm information The following command displays RMON alarm information: show rmon alarm Command mode: All RMON Alarm group configuration: Index ----- 1 2 3 4 5 8 10 11 15 18 100 Interval -------- 30 900 300 1800 1800 1800 1800 1800 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 50
crossed. Displays the last sampled value. Displays the MIB Object Identifier for each alarm index. RMON event information The following command displays RMON event information: show rmon event Command mode: All RMON Event group configuration event for Link Down Log and trap event for Link Up Send - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 51
command displays link information: show interface link Command mode: All except User EXEC Port Speed Duplex Flow Ctrl Link yes down 24 any any yes yes down Use this command to display link status information about each port on a switch, including: • Port number • Port speed (10 Mb - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 52
command displays port information: show interface information Command mode: All except User EXEC Port Tag RMON PVID NAME VLAN(s) VLAN tagging or not (y or n) • Whether Remote Monitoring (RMON) is enabled or disabled (e or d) • Port VLAN ID (PVID) • Port name • VLAN membership Information Commands - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 53
Failure Detection (UFD) information: show ufd Command mode: All except User EXEC Uplink Failure Detection: Enabled LtM status: Down Member STG STG State port 24 1 DISABLED 10 DISABLED * 15 DISABLED * * = STP turned off for this port. Link Status ----------- down LtD status: Auto - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 54
and member ports Information dump The following command dumps switch information: show information-dump Command mode: All Use the dump command to dump all switch information available from GbE2c memory (10K or more, depending on your configuration). This data is useful for tuning and debugging - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 55
. Table 43 Statistics commands Command Usage show layer2 counters Displays Layer 2 Statistics. Command mode: All show layer3 counters Displays Layer 3 Statistics. Command mode: All NOTE: Layer 3 commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. show snmp-server - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 56
to display the 802.1x authenticator statistics of the selected port: show interface port dot1x counters Command mode: All Authenticator Statistics: eapolFramesRx = 0 eapolFramesTx = 0 eapolStartFramesRx = 0 eapolLogoffFramesRx = 0 eapolRespIdFramesRx = 0 eapolRespFramesRx - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 57
of times that the state machine receives a Reject message from the Authentication Server. Indicates that the Supplicant has not authenticated to the Authentication Server. Statistics commands 57 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 58
the problem has been occurring but is not persistent. dot1StpPortForwardTransitions The number of times this port has transitioned from the Learning state to the Forwarding state. Ethernet statistics Use the following command to display the ethernet statistics of the selected port: show interface - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 59
when the alignmentError status is returned by the MAC service to the Logical Link Control (LLC) (or other MAC user). Received frames for which multiple error conditions obtained are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 60
is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtained are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 61
field was not a valid address to be received at this entity (the switch). The number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were discarded (for example, for lack of buffer space). Note that this counter does not include any - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 62
The total number of link state changes. Layer 2 statistics The following table describes the Layer 2 statistics commands. The following sections provide more detailed information and commands. Table 51 Layer 2 Statistics commands Command show mac-address-table counters show interface port - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 63
describes basic Layer 3 statistics commands. The following sections provide more detailed information and commands. Table 53 Layer 3 Statistics commands Command show ip counters clear ip counters show ip route counters show ip arp counters show ip dns counters show ip icmp counters show ip tcp - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 64
all Layer 3 statistics. Command mode: All except UserEXEC * indicates commands that are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. IP statistics The following command displays IP statistics: show ip counters Command mode: All except User EXEC IP statistics: ipInReceives - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 65
ever recorded in the ARP table. DNS statistics show ip dns counters Command mode: All except User EXEC DNS statistics: dnsInRequests: 0 dnsOutRequests: 0 dnsBadRequests: 0 The following table describes the Domain Name System (DNS) statistics: Table 57 DNS statistics Statistic Description - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 66
The following command displays ICMP statistics: show ip icmp counters Command mode: All except User EXEC ICMP this switch did not send due to problems discovered within ICMP such as a lack of buffer. This value should not include errors discovered outside the ICMP layer such as the inability of IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 67
statistics The following command displays TCP statistics: show ip tcp counters Command mode: All except User EXEC TCP statistics in RFC 793. The limit on the total number of TCP connections the switch can support. In entities where the maximum number of connections is dynamic, this object should - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 68
of segments received in error (for example, bad TCP checksums). The total application at the destination port. IGMP Multicast Group statistics The following command displays statistics about the use of the IGMP Multicast Groups: show ip igmp counters Command mode: All except User EXEC Enter VLAN - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 69
Leave messages transmitted OSPF statistics NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes OSPF statistics commands. Table 62 OSPF Statistics commands Command Usage show ip ospf counters general Displays OSPF global statistics - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 70
OSPF global statistics NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following command displays OSPF global statistics: show ip ospf counters general Command mode: All except User EXEC OSPF stats ---------Rx/Tx Stats: Pkts hello database ls requests ls - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 71
Intf Change Stats: up down loop unloop wait timer backup Description The sum total of all Link State Update packets received on all OSPF areas and interfaces. The sum total of all Link State Update packets transmitted on all OSPF areas and interfaces. The sum total of all Hello packets received - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 72
of times the Autonomous System Export (ASE) timer has been fired. VRRP statistics Virtual Router Redundancy Protocol (VRRP) support on the GbE2c Ethernet Blade switch provides redundancy between routers in a LAN. This is accomplished by configuring the same virtual router IP address and ID number - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 73
advertisements that had a bad interval. RIP statistics NOTE: RIP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following command displays RIP statistics: show ip rip counters Command mode: All except User EXEC RIP ALL STATS INFORMATION: RIP packets received = 12 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 74
GEA Layer 3 statistics The following command displays GEA statistics: show ip gea Command mode: All except User EXEC GEA L3 statistics: Max L3 table size Number of L3 entries used : 4096 : 9 Max LPM table size : 4097 Number of LPM entries used : 31 Max block in LPM table : 255 Number of - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 75
Memory Destination IP address Destination port Source IP Source port State Example statistic 10ad41e8/10ad5790 0.0.0.0/47.81.27.5 0/1171 0.0.0.0/47.80.23.243 80/23 listen/established UDP statistics The following command displays UDP statistics: show mp udp-block Command mode: All except User EXEC - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 76
CPU statistics The following command displays the CPU utilization statistics: show mp cpu Command mode: All except User EXEC CPU utilization: cpuUtil1Second: 8% cpuUtil4Seconds: 9% cpuUtil64Seconds: 8% The following table describes the management port CPU utilization statistics: Table 70 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 77
(Basic Encoding Rules), errors encountered by the SNMP protocol entity when decoding SNMP messages received. The Open Systems enable or disable the authentication traps generated by this switch. The total number of SNMP messages which were passed from the SNMP protocol entity to the transport service - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 78
-PDUs,GetBulkRequest-PDUs, SetRequest-PDUs, and InformRequest-PDUs delivered to the SNMP entity which were silently dropped because the transmission of the message to a proxy target failed in a manner (other than a time-out) such that no Response-PDU could be returned. Statistics - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 79
The switch system time when the command show ntp counters was issued. Uplink Failure Detection statistics The following command allows you to display Uplink Failure Detection (UFD) statistics. show ufd counters Command mode: All Uplink Failure Detection statistics: Number of times LtM link failure - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 80
were automatically disabled because of a failure in the Link to Monitor group. Statistics dump The following command dumps GbE2c statistics: show counters Use the dump command to dump all switch statistics available (40K or more, depending on your configuration). This data can be used to tune or - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 81
memory, so the GbE2c reloads the setting when you reset the switch. IMPORTANT: If you do not save the changes, they are lost the next time the system is reloaded. To save the new configuration, enter the following command at any prompt: Switch# copy running-config startup-config When you save - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 82
of the host name (system administrator's name) in the command line interface. Command mode: Global configuration Enables or disables the use of BOOTP. If you enable BOOTP, the switch will query its BOOTP server for all of the switch IP parameters. The default value is enabled. Command mode: Global - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 83
-based Interface (BBI). NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for information on SSH. The following table describes the SSHD Configuration commands. Table 77 SSHD Configuration commands Command ssh interval ssh scp-password ssh generate - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 84
enable Disables the SSH server. This is the default for the SSH server. Command mode: Global configuration show ssh Displays the current SSH server configuration. Command mode: All RADIUS server configuration NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 85
is the default. Command mode: Global configuration Displays the current RADIUS server parameters. Command mode: All IMPORTANT: If RADIUS is enabled, you must login using RADIUS authentication when connecting via the console or Telnet/SSH/HTTP/HTTPS. Backdoor for console is always enabled, so you - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 86
default value is disabled. Command mode: Global configuration Maps a TACACS+ authorization level to a GbE2c user level. Enter a TACACS+ privilege level (0-15), followed by the corresponding GbE2c user level (user, oper, admin). Command mode: Global configuration Enables the TACACS+ server. Command - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 87
Enables the NTP synchronization service. Command mode: Global configuration Disables the NTP synchronization service. This is the default. Command mode: Global configuration Displays the current NTP service settings. Command mode: All System SNMP configuration The switch software supports - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 88
use of the system authentication trap facility. The default setting is disabled. Command mode: Global configuration [no] snmp-server linktrap Enables or disables the sending of SNMP link up and link down traps. The default setting is enabled. Command mode: Global configuration [no] snmp-server - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 89
index. A notification application typically monitors a system for particular events or conditions, and generates Notification-Class messages based on these events or conditions. The range is 1-16. Command mode: Global configuration snmp-server version {v1v2v3|v3only} Enables or disables the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 90
. An example of an OID is 1.3.6.1.2.1.1.1.0 Command mode: Global configuration snmp-server configuration. Command mode: All View-based Access Control Model configuration The view-based Access Control Model defines a set of services that an application can use for checking access rights of the user - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 91
tag specifies a set of transport endpoints to which a command responder application sends an SNMP trap. Command mode: Global configuration Deletes the community table entry. Command mode: Global configuration Displays the community table configuration. Command mode: All Configuration Commands 91 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 92
of 15 characters. To disable a user, set the password to null. The following table describes the SNMPv3 Target Address Table Configuration commands. Table 88 SNMPv3 Target Address Table Configuration commands Command Description snmp-server target-address Configures the locally arbitrary, but - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 93
System Access configuration The following table describes the System Access Configuration commands. Table 91 System Access Configuration commands Command Description [no] access http enable Enables or disables HTTP (Web) access to the Browser-based Interface. It is enabled by default. Command - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 94
and can reset ports or the entire switch. Command mode: Global configuration access user administrator-password Sets the administrator (admin) password (maximum of 128 characters). The super user administrator has complete access to all information and configuration commands on - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 95
the Class-of-Service to define the user's authority level. Command mode: Global configuration Defines the user name of maximum eight characters. Command mode: Global configuration Sets the user password of up to 128 characters maximum. Command mode: Global configuration Enables the user ID. Command - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 96
VLAN tag matches the port PVID. The default value is enabled. Command mode: Interface port copper Configures the port's transmission media as copper. This command is available only for uplink ports. This command is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. fiber Configures - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 97
the Gigabit Link Configuration commands. Table 97 Gigabit Link Configuration commands Command Description speed {10|100|1000|auto} Sets the link speed. Not all options are valid on all ports. The choices include: • 10 Mb/s • 100 Mb/s • 1000 Mb/s • "auto," for automatic detection (default) Note - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 98
detailed information and commands. Table 99 Layer 2 Configuration commands Command vlan {} [no] spanning-tree uplinkfast spanning-tree uplinkfast max-update-rate show layer2 Description Enter VLAN configuration mode. Command mode: Global configuration Enables or disables Fast - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 99
is enabled. The default value is 3600 seconds. Command mode: Global configuration Sets the re-authentication status to on or off. The default value is off. Command mode: Global configuration Resets the global 802.1x parameters to their default values. Command mode: Global configuration Displays - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 100
: Interface port Sets the re-authentication status to on or off. The default value is off. Command mode: Interface port Resets the global 802.1x parameters to their default values. Command mode: Interface port Displays current global 802.1x parameters. Command mode: All Configuration Commands 100 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 101
configuration. Command mode: All NOTE: • IEEE 802.1w standard-based RSTP implementation runs on one STG (i.e. same as one spanning tree instance) only. As a result, if 'rstp' mode is selected, then only a single RSTP instance (default for STG 1) is supported for all VLANs, including the Default - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 102
to configure CIST commands. Table 104 CIST Configuration commands Command Description spanning-tree mstp cist- Adds VLANs to the CIST. Enter one VLAN per line, and press Enter to add the VLANs. add-vlan Command mode: Global configuration default spanning-tree mstp cist Resets all - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 103
traffic as soon as the link is up. Configure server ports as edge ports (enabled). This command is disabled by default. Command mode: Interface port spanning-tree mst cist enable Enables CIST on the port. Command mode: Interface port no spanning-tree mst cist enable Disables CIST on the port - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 104
CIST Port Configuration commands Command Description show interface port {} spanning-tree mstp cist Command mode: All Spanning Tree configuration The switch supports the IEEE 802.1d Spanning Tree Protocol (STP) and Cisco proprietary - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 105
STP parameters. Command mode: All When configuring STP bridge parameters, the following formulas must be used: • 2*(fwd-1) > mxage • 2*(hello+1) < mxage Spanning Tree port configuration By default for STP/PVST+, Spanning tree is turned Off for downlink ports (1-16), and turned On for cross-connect - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 106
range is 1 - 200000000, and the default it 20000 for Gigabit ports. Command mode: Interface port spanning-tree stp {} link {auto|p2p|shared} Defines the type of link connected to the port, as follows: auto: Configures the port to detect the link type, and automatically match its settings - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 107
must comply with Cisco® EtherChannel® technology. • By default, port 17 and port 18 are trunked to support an internal switch-to-switch crosslink trunk. By default, ports 17 and 18 are disabled. NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for information on - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 108
Layer 2 IP Trunk Hash configuration Trunk hash parameters are set globally for the GbE2c Ethernet Blade switch. You can enable one or two parameters, to configure any of the following valid combinations: • SMAC (source MAC only) • DMAC (destination MAC only) • SIP (source IP only) • DIP ( - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 109
VLAN 1, which is always enabled. The switch supports a maximum of 1,000 VLANs. VLAN 4095 is reserved for switch management. NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for information on VLANs. The following table describes the VLAN Configuration commands - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 110
IP configuration. Command mode: All except User EXEC * indicates command modes that apply only to the GbE2c Ethernet Blade Switch. IP interface configuration The switch can be configured with up to 256 IP interfaces. Each IP interface represents the switch on an IP subnet on your network. The IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 111
. Command mode: Interface IP Removes this IP interface. Command mode: Global configuration Displays the current interface settings. Command mode: All NOTE: If you enter an IP address for interface 1, you are prompted to change the BOOTP setting. Default Gateway configuration The switch supports - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 112
on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the Static Route Configuration commands. Table 120 Static Route Configuration commands Command ip route [] no ip route {}{} show ip route - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 113
the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the Network Filter Configuration commands. Table 123 Network Filter Configuration commands Command ip match-address ip match-address enable no ip match-address enable no ip - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 114
mode: Route Map Deletes the route map. Command mode: Route Map Displays the current route configuration. Command mode: All except User EXEC IP Access List configuration NOTE: Access List commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The route map number (1-32) and the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 115
on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the basic RIP Configuration commands. The following section provides more detailed information and commands. Table 127 RIP Configuration commands Command router rip timers update {} enable no enable show ip rip - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 116
The default is none. Command mode: Interface IP Configures the authentication key password. Command mode: Interface IP Enables this RIP interface. Command mode: Interface IP Disables this RIP interface. Command mode: Interface IP Displays the current RIP configuration. Command mode: All except User - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 117
on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the basic Open Shortest Path First (OSPF) commands. The following sections provide more detailed information and commands. Table 130 OSPF Configuration commands Command router ospf area area-range ip ospf - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 118
Description Enables OSPF. Command mode: Router OSPF Disables OSPF. Command mode: Router OSPF Displays the current OSPF configuration settings. Command mode: All except User EXEC OSFP Area Index configuration NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 119
range. Command mode: All except User EXEC OSPF Interface configuration NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the OSPF Interface Configuration commands. Table 133 OSPF Interface Configuration commands Command ip ospf - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 120
the OSPF interface. Command mode: Interface IP show interface ip ospf {} Displays the current settings for OSPF interface. Command mode: All except User EXEC OSPF Virtual Link configuration NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 121
only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the OSPF Host Entry Configuration commands. Table 135 OSPF Host Entry Configuration commands Command host address host area host cost host enable no host - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 122
Route Redistribution Configuration commands Command show ip ospf redistribute Description Displays the current route map settings. Command mode: All except User EXEC OSPF MD5 Key configuration NOTE: OSPF commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 123
mrouter Removes a static multicast router from the selected port/VLAN combination. Command mode: Global configuration show ip igmp mrouter Displays the current IGMP Static Multicast Router parameters. Command mode: All except User EXEC Configuration Commands 123 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 124
table describes the IGMP Port Filtering Configuration commands. Table 142 IGMP Filtering Port commands Command [no] ip igmp filtering ip igmp profile no ip igmp profile show interface port {} igmp-filtering Description Enables or disables IGMP Filtering on this - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 125
configuration enables the switch to forward a client request for an IP address to two DHCP/BOOTP servers with IP addresses that have been configured on the GbE2c Ethernet Blade switch. BOOTP relay is turned off by default. NOTE: BOOTP commands are available only on the GbE2c Layer 2/3 Ethernet Blade - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 126
see the "High Availability" chapter in the HP c-Class GbE2c Ethernet Blade Switch Application Guide. NOTE: VRRP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the basic VRRP Configuration commands. The following sections provide more detailed - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 127
routers, otherwise called "virtual interface routers". A virtual server router is defined as any virtual router whose IP address is the same as any configured virtual server IP address. NOTE: VRRP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. Configuration Commands 127 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 128
and IP address. NOTE: VRRP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the Virtual Router Group Configuration commands. Table 148 Virtual Router Group Configuration commands Command group virtual-router-id group interface - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 129
only on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the Virtual Router Group Priority Tracking Configuration commands. Table 149 Virtual Router Group Priority Tracking Configuration commands Command [no] group track interfaces [no] group track ports show ip vrrp group - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 130
on the GbE2c Layer 2/3 Ethernet Blade Switch. The following table describes the VRRP Interface Configuration commands. Table 150 VRRP Interface Configuration commands Command interface authentication {password|none} interface password no interface show ip vrrp - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 131
various types of traffic, and provide different priority levels. QoS 802.1p configuration This feature provides the GbE2c Ethernet Blade switch the capability to filter IP packets based on the IEEE 802.1p bits in the packet's VLAN header. The 802.1p bits specify the priority that you should give - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 132
> ethernet Resets Ethernet parameters for the ACL to their default values. Command mode: Global configuration show access-control list {} ethernet Displays the current Ethernet parameters for the ACL. Command mode: All except User EXEC ACL IP Version 4 Filter configuration These commands - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 133
Defines the tagging format for the ACL. Command mode: Global configuration Resets Packet Format parameters for the ACL to their default values. Command mode: Global configuration Displays the current Packet Format parameters for the ACL. Command mode: All except User EXEC Configuration Commands 133 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 134
list Reset ACL Metering parameters to their default values. meter Command mode: Global configuration show access-control list meter Command mode: All except User EXEC ACL Re-mark configuration You can choose to re-mark IP header - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 135
(Type of Service) priority to 802.1p priority for In-Profile packets. When enabled, the TOS value is used to set the 802.1p value. Command mode: Global configuration default access-control list Resets UP1P settings to their default values. re-mark Command mode: Global configuration show - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 136
the current RMON configuration. Command mode: All RMON history configuration The following table describes the RMON History commands. Table 165 RMON History commands Command Description rmon history interface-oid Configures the interface MIB Object Identifier - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 137
rising alarm event index that is triggered when a rising threshold is crossed. The range is from 0 to 65535. The default value is 0. Command mode: Global configuration rmon alarm fallingcrossing-index < 0-65535> Configures the falling alarm event index that is triggered when a falling - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 138
: See the "Troubleshooting tools" appendix in the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for information on how to use port mirroring. The following table describes the Port Mirroring Configuration commands. Table 168 Port Mirroring Configuration commands Command - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 139
(UFD) supports network fault tolerance in network adapter teams. Use these commands to configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When UFD is enabled and a Failure Detection Pair is configured, the switch automatically disables - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 140
)# copy {tftp|ftp} running-config NOTE: The switch supports three configuration files: active, backup, and factory. See the "Selecting a configuration block" section in the "Boot Options" chapter for information on how to set which configuration file to use upon boot up. Configuration Commands 140 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 141
the port. RMON must be enabled for any RMON configurations to function. Command mode: Interface port no interface port shutdown Temporarily enables the port. The port will be returned to its configured operation mode when the switch is reloaded. Command Mode: Priv EXEC NOTE: This - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 142
only applies if the port's 802.1x mode is configured as auto. Command Mode: Privileged EXEC Operations-level VRRP options NOTE: VRRP commands are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. Operations-level VRRP options are described in the following table. Table 177 Operations - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 143
the "Domain name system configuration" section in the "Configuration Commands" chapter. When the above requirements are met, use the following procedure to download the new software to the GbE2c Ethernet Blade Switch. 1. In Privileged EXEC mode, enter: Switch# copy tftp { - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 144
for the next reboot. 1. In Global Configuration mode, enter: Router(config)# boot image {image1|image2} 2. Enter the name of the image you want the switch to use upon the next boot. The system informs you of which image is currently set to be loaded at the next reset, and prompts you to enter a new - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 145
procedure to set which configuration block you want the switch to load the next time it is reset: 1. In Global Configuration mode, enter: Switch(config)# boot configuration-block {active|backup|factory} 2. Enter the name of the configuration block you want the switch to use. The system indicates - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 146
reload the switch: >> Switch# boot cli-mode aos The default command-line interface for the GbE2c is the AOS CLI. To access the ISCLI, enter the following command and reset the GbE2c: Main# boot/mode iscli Users can select the CLI mode upon login, if the following command is enabled: boot cli-mode - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 147
that is attached to the console port. • The switch detects a hardware or software problem that requires a reboot. The following sections provide detailed information and commands. System maintenance The System Maintenance commands are reserved for use by HP technical support. The options are used - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 148
to the factory default settings. Command mode: All except User EXEC ARP cache maintenance The following table describes the Address Resolution Protocol commands: Table 181 ARP Maintenance commands Command show ip arp find show ip arp interface show ip arp vlan - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 149
Snooping Maintenance commands Command show ip igmp groups address show ip igmp groups vlan show ip igmp groups interface show ip igmp groups clear ip igmp snoop Usage Shows a single IGMP Multicast group by IP address. Command mode: All except User EXEC Shows - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 150
SunOS or the Solaris operating system, the specified copy flash-dump tftp (or ftp)file must exist prior to executing the copy flash-dump tftp command (or copy flash-dump tftp) command, and must be writable (set with proper permission, and not locked by any application). The contents of the specified - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 151
to flash memory, the following message is displayed when you log on to the switch: Note: A system dump exists in FLASH. The dump was saved at 13:43:22 Wednesday October 30, 2006. Use show flash-dump uuencode to extract the dump - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 152
mode, 97; port link speed, 97; port mirroring, 138; port trunking, 107; switch IP address, 110; VLAN default (PVID), 96; VLAN IP interface, 110; VLAN tagging, 96 configuration block, 145 configuring RMON (remote monitoring), 136 connecting: via console, 8; via Secure Shell (SSH), 9; via Telnet - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Referenc - Page 153
105; switch reset effect, 146; with trunk groups, 36 state (STP information), 32, 34, 36 statistics dump, 80 Statistics Menu, 55 subnets: IP interface, 110 switch: reset, 146 syslog: display messages, 25 system: date and time, 17, 18, 19, 20, 21, 22, 26; information, 24, 54 System Configuration Menu
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem
ISCLI Reference Guide
Part number: 437881-002
Second edition: December 2006