HP Integrity rx1620 FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu
HP Integrity rx1620 Manual
View all HP Integrity rx1620 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity rx1620 manual content summary:
- HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 1
HP StorageWorks FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide Part number: AA-RW8JA-TE First edition: February 2006 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 3
Installing the Windows drivers using the HP Smart Component 17 4 Installing the Linux driver 19 Prerequisites 19 Installing the Linux driver 19 5 Troubleshooting POST LED states Using the Event Viewer Windows miniport driver event log codes Linux driver events Setting the jumpers - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 4
Index 29 4 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 5
Figures 1 Removing the bracket 2 LED location 3 Jumper settings 4 Class 1 laser product label 5 BSMI notice 6 Japanese notice 7 Korean notice 14 21 24 26 27 27 27 FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 5 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 6
Tables 1 Document conventions 7 2 Environmental specifications 10 3 Physical specifications 11 4 Media specifications 12 5 POST LED states 22 6 Jumper settings (Port 0 and Port 1 23 6 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 7
• System output • User input • Code • Text typed at the command line • Code variables • Command-line variables WARNING! Indicates that failure to follow directions could result in bodily harm or death. FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 7 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 8
serial numbers • Product model names and numbers • Applicable error messages • Operating system type and revision level • Detailed, specific questions Subscription service HP strongly recommends that customers register online using the Subscriber's choice web site: http://www.hp.com/go/e-updates - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 9
by the firmware • On-board diagnostic capability accessible through an optional connection • Parts and construction compliant with the European Union Directive of Restriction of Hazardous Substances (RoHS) FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 9 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 10
Environmental specifications Table 2 lists the HBA environmental specifications. Table 2 Environmental specifications Feature Operating temperature Minimum 0°C/32°F Storage temperature -20°C/-40°F Relative humidity (noncondensing) 5% Airflow 100 lf/minute Maximum 45°C/113°F 70°C/158°F 95% N/A - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 11
dual (FC2243 HBA) optical fiber LC connector. Physical dimensions Power • 6.0 watts (total) Agency approvals Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1 UL recognized to UL60950 certified by TUV to 60950-1 FCC Rules, Part 15, Class A Industry Canada, ICES-003, Windows installation guide 11 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 12
Media specifications Use multimode fiber optic cable (with short-wave lasers) that complies with the specifications listed in Table 4. Table 4 Media specifications Fiber optic cable 62.5/ - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 13
HBA on a Fibre Channel circuit. The WWN address and serial number are clearly marked on the HBA. Record this information for future reference. NOTE: The WWN is a static identifier that cannot be changed. FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 13 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 14
into the slot and press firmly until the HBA is seated properly. NOTE: Some HP server models support only PCI-X HBAs inserted in optional PCI-X riser cards or cages. For instructions on installing the riser card or cage, see your server documentation. 6. Secure the HBA to the chassis, following the - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 15
connected to a similar or compatible laser product; that is, both products are mulitmode. 9. Turn on the computer and observe the power-on self-test (POST) LED results (see "POST LED states" on page 21). FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 15 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 16
16 Installing the HBAs - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 17
configuration and operating system. Installing the Windows drivers using the HP Smart Component This section describes how to install the Windows SCSIPORT miniport driver and Storport miniport driver. NOTE: HP does not support Device Manager to update drivers. Using Device Manager can delete registry - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 18
. b. Click Install. c. Click Reboot to complete the installation. NOTE: HP recommends that you install the driver automatically by using Install rather than Extract. Using Extract saves the files to disk, enabling you to manually load the driver at another time. 18 Installing the Windows drivers - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 19
Red Hat Enterprise Linux (RHEL) system or a SUSE Linux Enterprise Server (SUSE SLES) system. • Prerequisites, page 19 • Installing the Linux driver, page 19 Prerequisites Before you install the driver: • Access the HP web site: http://h18006.www1.hp.com/storage/saninfrastructure.html and obtain - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 20
Install the driver: a. Copy the .tar.gz file to the servers on which you will deploy the updated driver. b. Enter the following command: tar zxvf hp-lpfc-yyyy-mm-dd.tar.gz Entering this command extracts the files in the driver kit and copies them to the hp-lpfc directory. c. Change directory to the hp - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 21
that you can use in the event of an HBA problem. • POST LED states, page 21 • Using the Event Viewer, page 22 • Windows miniport driver event log codes, page 23 • Linux driver events, page 23 • Setting the jumpers, page 23 POST LED states Table 5 describes the POST LED states. Figure 2 shows - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 22
a problem occurs, follow the instructions in this chapter to troubleshoot. Using the Event Viewer The SCSIPORT and Storport miniport drivers verify the HBA's POST LED states. If there is a failure or a suspected failure, an error log entry is written to the Windows event log. To view the event log - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 23
is written to the /var/log/messages file. Check this file periodically to review fabric or driver events. Setting the jumpers Each HBA has two six-post jumper blocks, one for each port, that control the HBA's device ID. You select the ID by installing a jumper between posts 1 and 2, 3 and 4, or - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 24
Figure 3 shows the jumper settings. Figure 3 Jumper settings 24 Troubleshooting - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 25
Outside the USA, the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in IEC 825-1:1993 and EN 60825-1:1994, including Amendment 11:1996 and Amendment 2:2001. FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide 25 - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 26
on the surface of the HP-supplied laser device. Figure 4 Class 1 laser product label International notices and statements 11)-Electromagnetic Immunity • Power Quality: • EN61000-3-2 (IEC61000-3-2)-Power Line Harmonics • EN61000-3-3 (IEC61000-3-3)-Power Line Flicker • EN60950 (IEC60950)-Product - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 27
handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. FC2143 and FC2243 4Gb PCI-X 2.0 host bus adapters for Linux and Windows installation guide - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 28
• Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the recommended equipment for proper grounding, have an HP-authorized reseller install the part. NOTE: For more information on static electricity, or assistance with product installation, contact - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 29
installing Linux driver, 19 installing Windows drivers, 17 media specifications, 12 performance specifications, 9 physical specifications, 11 POST LED states, 21 recording reference numbers, 13 setting jumpers, 23 troubleshooting, 21 HP Subscriber's choice web site, 8 subscription service, 8 hp-lpfc - HP Integrity rx1620 | FC2143 and FC2243 4Gb PCI-X 2.0 Host Bus Adapters for Linu - Page 30
service, HP, 8 symbols in text, 7 T text symbols, 7 troubleshooting event log, 22 HBAs, 21 Linux, 23 miniport driver event logs, 23 using POST LED states, 21 Windows Event Viewer, 22 W warnings, lasers radiation, 25 web sites HP documentation, 7 HP Subscriber's choice, 8 Windows driver installation
HP
StorageWorks
FC2143
and
FC2243
4Gb
PCI-X
2.0
host
bus
adapters
for
Linux
and
Windows
installation
guide
Part
number:
AA-RW8JA-TE
First
edition:
February
2006