HP Integrity rx8620 HP Insight Management WBEM Providers on Integrity Servers
HP Integrity rx8620 Manual
View all HP Integrity rx8620 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity rx8620 manual content summary:
- HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 1
HP Insight Management WBEM Providers for Windows on Integrity Servers Data Sheet Part number 5992-4515 First Edition September 2008 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP license. Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 3
Contents 1 Overview...13 2 Base server ...14 2-1 Overview...14 2-2 Use cases ...14 2-3 Class implementations ...14 2-3-1 HP_ProcessorLocation ...41 3-3-18 HP_ProcessorElementLocation 42 3-4 Supported indications...42 4 System Power Supply ...43 4-1 Overview...43 4-2 Use cases ...43 4-3 Class - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 4
HP_NumericSensor...59 6-3-2 HP_SensorCollection...62 6-3-3 HP_MemberOfSensorCollection 62 6-3-4 HP_HostedSensorCollection 63 6-3-5 HP_SystemSensor ...63 6-4 Supported indications...63 7 System memory ...64 7-1 Overview...64 7-2 Use cases ...64 7-3 Class implementations ...64 7-3-1 HP_Memory ...64 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 5
81 7-3-20 HP_MemoryBoardSlotElementLocation 82 7-3-21 HP_SystemMemoryModuleSlot 82 7-3-22 HP_SystemMemoryBoardSlot 82 7-4 Supported indications...83 8 PCI Device ...84 8-1 Overview...84 8-2 Use cases ...84 8-3 Class implementations ...84 8-3-1 HP_PCIDevice...84 8-3-2 HP_PCIBridge - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 6
126 12-3-21 HP_Location ...127 12-3-22 HP_ElementLocation 127 12-3-23 HP_EthEventSettings 128 12-4 Supported indications ...129 13 Smart Array ...157 13-1 Overview ...157 13-2 Use cases...157 13-3 Class implementations ...157 13-3-1 HPSA_ArraySystem ...157 13 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 7
13-3-20 13-3-21 13-3-22 13-3-23 13-3-24 13-3-25 13-3-26 13-3-27 13-3-28 13-3-29 13-3-30 13-3-31 13-3-32 13-3-33 13-3-34 13-3-35 13-3-36 13-3-37 13-3-38 13-3-39 13-3-40 13-3-41 13-3-42 13-3-43 13-3-44 13 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 8
HPSA_DiskPhysicalPackageDiskDriveLocation (Association 196 HPSA_SCSIProtocolEndpointSCSIProtocolController (Association 197 HPSA_StorageEnclosureEnclosureLocation (Association 197 Supported indications ...197 14 FC HBA...249 14-1 Overview ...249 14-2 Use cases...249 14-2-1 Get statistics - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 9
27 14-3-28 14-3-29 14-3-30 14-3-31 14-3-32 14-3-33 14-3-34 14-3-35 14-4 HPFCHBA_SoftwareIdentityDrvPortController 268 271 HPFCHBA_Location 271 HPFCHBA_PhysicalElementLocation 272 Supported indications ...272 15 SAS HBA...273 15-1 Overview ...273 15-2 Use cases...273 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 10
(Association 305 HPSAS_DiskPhysicalPackageDiskDriveLocation (Association 305 HPSAS_SCSIProtocolEndpointSCSIProtocolController (Association 305 Supported indications ...305 16 SCSI HBA ...340 16-1 Overview ...340 16-2 Use cases...340 16-3 Class implementations - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 11
16-3-23 16-3-24 16-3-25 16-3-26 16-3-27 16-3-28 16-3-29 16-3-30 16-3-31 16-3-32 16-3-33 16-3-34 16-3-35 16-3-36 16-3-37 16-3-38 16-3-39 16-3-40 16-3-41 HPSCSI_HBAComputerSystemSCSIProtocolEndpoint (Association 367 Supported indications ...367 17 System software ...402 17-1 Overview ...402 17-2 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 12
-3 18-3-1 18-3-2 18-3-3 18-3-4 18-3-5 18-4 Use cases...406 Class implementations ...406 CIM_RegisteredProfile...406 HP_RegisteredProfile...408 HP_ExtendsProfile...409 HP_ReferencedProfile...410 HP_ElementConformsToProfile 410 Supported indications ...410 19 For more information...411 Contents 12 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 13
1 Overview The HP Insight Management WBEM Providers supply system management data through the Windows® Management Instrumentation (WMI) framework for HP Integrity server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 14
installed by this provider. Table 2-1 Overview Implemented Profiles Provider Installation Files • HP Base Server Profile (P00105) • HP Base Server Physical Asset Profile (P00114) • model the base server. Only one instance of HP_WinComputerSystem is instantiated on an Integrity server. The following - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 15
EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName HP_WinComputerSystem Roles Computer system roles string (writable property; persistent across reboots). CIM_ComputerSystem 1BBase server 15 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 16
to not set (writable property; persistent across reboots). SecondaryOwnerPager Computer system secondary owner pager string; initialized to not set (writable property; persistent across reboots). 1BBase server 16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 17
chassis. Only one instance of HP_ComputerSystemChassis is instantiated on an Integrity server. The following properties are implemented. Table 2-3 Class: 3 (Chassis/Frame) See MOF for definitions. This value is retrieved from SMBIOS. • 0 (Unknown) • 1 (True) • 2 (False) 1BBase server 17 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 18
properties are implemented. Table 2-5 Class: HP_PowerManagementService Properties Property name CIM_ManagedElement Caption Description ElementName Property implementation Server Power Management Service HP Integrity Server Power Management Service Server Power Management Service 1BBase server 18 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 19
Service HP_PowerManagementService 2-3-5 HP_PowerManagementCapabilities HP_PowerManagementCapabilities extends the class CIM_PowerManagementCapabilities to model the server power management capabilities. Only one instance of HP_PowerManagementCapabilities is instantiated on an Integrity server - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 20
[1]: 4 (Power Cycling Supported) • PowerChangeCapabilities[0]: 3 (Power State Settable) • PowerChangeCapabilities[1]: 4 (Power Cycling Supported) • PowerStatesSupported[0]: 0 HP_AssociatedPowerManagementService is instantiated on an Integrity server. The following properties are implemented - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 21
and the HP_PowerManagementService instance. Only one instance of HP_HostedPowerManagementService is instantiated on an Integrity server. The following properties are implemented. Table 2-9 Class: HP_HostedPowerManagementService Property name CIM_Dependency CIM_HostedDependency CIM_HostedService - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 22
of the release date, MM is the two digit month of the release date, and DD is the two digit day of the release date. HP 11 (Bios/FCode) System ROM Firmware HPQ: where is the system ROM family code (for example, HPQ:P31). CIM:SoftwareFamily 1BBase - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 23
CIM_InstalledSoftwareIdentity and associates the HP_ComputerSystem instance and an HP_SystemROMFirmware instance. The following properties are implemented. Table 2-12 Class: HP_SystemROMInstalledFirmwareIdentity Property name CIM_InstalledSoftwareIdentity Property implementation 1BBase server 23 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 24
Property name HP_SystemROMInstalledFirmwareIdentity InstalledSoftware System Property implementation ref: HP_SystemROMFirmware ref: HP_ComputerSystem 2-4 Supported indications There are no indications specific to the base server profile implementation. 1BBase - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 25
the following files are installed by this provider. Table 3-1 Overview Implemented Profiles Provider Installation Files • HP CPU Profile (P00106) • HP CPU Consolidated Status Profile (P00107) • HP CPU Physical Asset Profile (P00108) • HP Location Profile (P00124) • HPWmiProc.dll • HPWmiProcEvt.dll - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 26
> is the processor brand string, x is the processor family number, y is the processor model number and z is the processor stepping number Example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) A string indicating the processor physical location. On cellular systems, the location - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 27
(CPU Disabled by User using BIOS Setup) • 3 (CPU Disabled By BIOS (POST Error)) • 7 (Other) Processor family number from SMBIOS (for example, 179 for Intel(R) Xeon(TM)) Maximum clock speed in MHz( for example, 3600) Current clock speed in MHz (for example, 3066) 64 64 External bus clock speed in - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 28
number, y is the processor model number, z is the processor stepping number, p is the processor number, and c is the core number Example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) (Processor 1 - Core 2) Processor p - Core c, where p is the processor physical location and c is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 29
Table 3-4 Class: HP_ProcessorCore Property name OperationalStatus StatusDescriptions HealthState CIM_LogicalElement CIM_EnabledLogicalElement EnabledState RequestedState EnabledDefault CIM_ProcessorCore InstanceID CoreEnabledState Property implementation • 0 (Unknown) • 2 (OK), when CPU is enabled - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 30
: Characteristics[0]: 3 (32-bit Capable) • For x64 processors: ○ Characteristics[0]: 3 (32-bit Capable) ○ , p is the processor number, c is the core number, and t is the thread number Example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) (Processor 1 - Core 2) Processor - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 31
Table 3-5 Class: HP_HardwareThread Property name OperationalStatus StatusDescriptions HealthState CIM_LogicalElement CIM_EnabledLogicalElement EnabledState RequestedState EnabledDefault CIM_HardwareThread InstanceID HP_HardwareThread Property implementation • 0 (Unknown) • 2 (OK), when CPU is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 32
Unified Cache One of the following: • Level x Data Cache, where x is the cache level number • Level x Instruction Cache, where x is the cache level number • Level x Unified Cache, where x is the cache level number Examples: POST error • 10 (Stopped), when CPU is disabled through RBSU 2BCPU 32 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 33
of the following: • Proc p, Level x Cache, where p is the processor number, x is the cache level number, and is the cache type (Data, Instruction, or Unified) • Proc p, Core c, Level x Cache, where p is the processor number, c is the core number, x is the cache level number, and - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 34
Table 3-6 Class: HP_ProcessorcacheMemory Property name NumberOfBlocks Primordial CIM_Memory HP_CacheMemory HP_ProcessorCacheMemory Property implementation Number of blocks in this cache (for example, 8192 or 524288) 0 (False) 3-3-6 HP_SystemProcessor HP_SystemProcessor extends the class - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 35
HP_ProcessorCore ref: HP_HardwareThread 3-3-10 HP_AssociatedCacheMemory HP_AssociatedCacheMemory extends the class CIM_AssociatedCacheMemory. The Integrity implementation class is HP_AssociatedProcessorCacheMemory. HP_AssociatedProcessorCacheMemory associates an HP_Processor or an HP_ProcessorCore - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 36
(Tertiary) • 0 (Unknown) • 1 (Other) • 2 (Write Back) • 3 (Write Through) • 4 (Varies with Address) • 5 (Determination Per I/O) • 0 (Unknown) • 1 (Other) • 2 (Instruction) • 3 (Data) • 4 (Unified) Cache line size in bytes • 0 (Unknown) • 1 (Other) • 2 (Read) • 3 (Read-Ahead) • 4 (Read and Read-Ahead - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 37
3-3-11 HP_ProcessorCollection HP_ProcessorCollection extends the class HP_GroupSystemSpecificCollection. The following properties are implemented. Table 3-12 Class: HP_ProcessorCollection Property name CIM_ManagedElement Description ElementName CIM_Collection CIM_SystemSpecificCollection InstanceID - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 38
Table 3-13 Class: HP_ProcessorGroupHostedCollection Property name CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_ProcessorGroupHostedCollection Antecedent Dependent Property implementation ref: HP_ComputerSystem ref: HP_ProcessorCollection 3-3-13 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 39
: a Socket: b), where is the processor family name string, a is the slot number, and b is the socket number (for example, Intel(R) Xeon(TM) Processor (Slot: 0 Socket: 2)) (x86 Family x Model y Stepping z), where is the processor brand - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 40
PoweredOn CanBeFRUed CIM_PhysicalComponent RemovalConditions CIM_Chip HP_ProcessorChip ProcessorChipRevision Property implementation Processor manufacturer string from SMBIOS (for example, Intel or AMD) Model y, where y is the processor model number Model y Stepping z, where y is the processor - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 41
> is the processor brand string, x is the processor family number, y is the processor model number and z is the processor stepping number Example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) A string indicating the processor physical location. On cellular systems, the location - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 42
Property name CIM_ElementLocation HP_ElementLocation HP_ProcessorElementLocation Element PhysicalLocation Property implementation ref: HP_ProcessorChip ref: HP_ProcessorLocation 3-4 Supported indications There are no indications specific to the CPU profile implementation. 2BCPU 42 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 43
Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 4-1 Overview Implemented Profiles Provider Installation Files • HP Power Supply Profile 1.0 • HP power supplies on Integrity Servers. The Windows-specific implementation class is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 44
describing the type of power supply (see MOF) 4-3-2 HP_PowerCollection HP_PowerCollection is used to model power supply collections on Integrity servers. The Windows implementation class is HP_WinPowerCollection. There is one instance of this class on systems modeling power supplies. 3BSystem - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 45
Table 4-3 Class: HP_PowerCollection Property name CIM_ManagedElement Caption Description ElementName CIM_SystemSpecificCollection InstanceID HP_GroupSystemSpecificCollection GroupOperationalStatus[0] GroupStatusDescriptions[0] Property implementation Power Collection This is a collection of all - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 46
power supply redundancy sets on Integrity servers. The Windows implementation class is redundancy set instance Unique identifier for this power redundancy instance The maximum number of power supplies supported for this redundancy set The minimum number of power supplies needed to function 3 (Load - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 47
Table 4-5 Class: HP_MemberOfPowerRedundancy Property name Collection Member Property implementation References HP_PowerRedundancySet References HP_PowerSupply 4-3-5 HP_HostedPowerRedundancySet HP_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 48
implementation References HP_ComputerSystem References HP_PowerSupply 4-3-9 HP_Location HP_Location is used to model power supply locations on Integrity servers. The Windows implementation class is HP_WinPowerSupplyLocation. Table 4-10 Class: HP_Location Property name CIM_ManagedElement Caption - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 49
CIM_ManagedElement References CIM_Location 4-3-11 CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model power supply configuration capacity on Integrity Servers. The Windows implementation class is HP_WinPowerSupplyConfigurationCapacity. There is one instance of this class on systems - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 50
4-4 Supported indications There are no indications specific to the system power supply profile implementation. 3BSystem Power Supply 50 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 51
the profiles listed to support fans installed in Integrity servers. The following profiles are implemented, and the following files are installed by this provider. Table 5-1 Overview Implemented Profiles Provider Installation Files • HP Fan Profile 1.0 • HP Location Profile 1.0 • HPWmiSensor.dll - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 52
for this fan instance HP_ComputerSystem.CreationClassName HP_ComputerSystem.Name 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) True • True-if fan supports variable speed • False-if fan does not support variable speed or is unknown Enumeration describing the type of fan (see MOF) 4BSystem fan 52 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 53
5-3-2 HP_CoolingCollection HP_CoolingCollection is used to model fan collections on Integrity Servers. The Windows implementation class is HP_WinCoolingCollection. There is one instance of this class on systems modeling fans. Table 5-3 Class: HP_CoolingCollection Property name CIM_ManagedElement - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 54
to model fan redundancy sets on Integrity servers. The Windows implementation class is set instance Unique identifier for this cooling redundancy instance Represents the maximum number of fans supported for this redundancy set Represents the minimum number of fans needed to function 3 (Load - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 55
Table 5-5 Class: HP_MemberOfCoolingRedundancy Property name Collection Member Property implementation References HP_CoolingRedundancySet References HP_Fan 5-3-5 HP_HostedCoolingRedundancySet HP_HostedCoolingRedundancySet is used to represent an association between HP_CoolingRedundancySet and the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 56
Property implementation References HP_ComputerSystem References HP_Fan 5-3-9 HP_Location HP_Location is used to model fan locations on Integrity servers. The Windows implementation class is HP_WinFanLocation. Table 5-10 Class: HP_Location Property name CIM_ManagedElement Caption Description - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 57
Property implementation References CIM_Location 5-3-11 CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model fan configuration capacity on Integrity Servers. The Windows implementation class is HP_WinFanConfigurationCapacity. There is one instance of this class on systems - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 58
5-4 Supported indications There are no indications specific to the system fan profile implementation. 4BSystem fan 58 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 59
Sensor 6-1 Overview This provider implements the HP Sensor Profile to model temperature sensors in Integrity servers. The following profiles are implemented, and the following files are installed by this provider. Table 6-1 Overiew Implemented Profiles Provider Installation Files • HP Sensor - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 60
Table 6-2 Class: HP_NumericSensor Property name Description ElementName CIM_ManagedSystemElement OperationalStatus[0] StatusDescriptions[0] HealthState Name CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_EnabledLogicalElement EnabledDefault EnabledState - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 61
Table 6-2 Class: HP_NumericSensor Property name SensorType CurrentState PossibleStates CIM_NumericSensor CurrentReading BaseUnits RateUnits UnitModifier SupportedThresholds SettableThresholds UpperThresholdNonCritical UpperThresholdCritical UpperThresholdFatal HP_NumericSensor NumericSensorType - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 62
6-3-2 HP_SensorCollection HP_SensorCollection is used to model temperature sensor collections on Integrity servers. The Windows implementation class is HP_WinSensorCollection. There is one instance of this class on systems modeling sensors. Table 6-3 Class: HP_SensorCollection Property name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 63
Class: HP_SystemSensor Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_NumericSensor 6-4 Supported indications There are no indications specific to the system temperature sensor profile implementation. 5BSystem Temperature Sensor 63 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 64
7 System memory 7-1 Overview This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 7-1 Overview Implemented Profiles - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 65
operational status. The status represents the 'worst-of' algorithm for all OperationalStatus[0] values reported by physical memory modules in HP_MemoryModule instances. • OperationalStatus[0] (shown in order of increasing severity; a higher severity overrides a lower severity): ○ 2 (OK), when all - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 66
Write Supported) 1 (byte) Capacity in bytes Capacity in bytes True System Memory False Beginning address of the memory in kilobytes Ending address of the memory in HP_MemoryModule The class HP_MemoryModule represents a physical memory module on Integrity servers. There is an instance of this class - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 67
the DIMM physical location. HP_MemoryModule HPQ:HP_MemoryModule:x-y, where x is the board/cartridge number where the memory module is located and y is the memory socket number where the memory module is located A string describing the DIMM index and the DIMM physical location. A string describing - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 68
is located. This property is conditional. It is populated if the data is available. An array that contains raw Serial Presence Detect information for the memory module. Each array element contains a byte of the Spd. This property is conditional; it is populated if the data is available. Table - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 69
7-3-4 HP_MemoryBoard The class HP_MemoryBoard represents a physical memory board on Integrity Servers. There is an instance of this class for each memory board in the system. Table 7-6 Class: HP_MemoryBoard Property name CIM_ManagedElement Caption CIM_ManagedSystemElement OperationalStatus - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 70
implementation A string describing the physical location of the memory board. On Integrity systems, a memory board instance can be a cell board, a system board or a memory extender board. Removal conditions of the memory board: • When the memory board is the system board: ○ 2 (Not applicable) • When - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 71
on the board. 7-3-5 HP_MemoryRedundancySet The class HP_MemoryRedundancySet represents memory board redundancy on Integrity servers supporting advanced memory protection (AMP). There is one instance of this class on systems supporting advanced memory protection. This class is not be instantiated on - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 72
system is operating in Mirrored mode • Online Spare, when the system is operating in Online Spare mode The desired or targeted mode of the Advanced Memory Protection system. • Advanced ECC, when the system is configured for Advanced ECC mode • RAID, when the system is configured for RAID (XOR) mode - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 73
the array contains one supported configuration. Possible values are: • Advanced ECC • Online Spare • Mirrored • RAID 7-3-6 HP_MemoryCollection The class HP_MemoryCollection represents physical memory collections on Integrity servers. The collection comprehends physical memory modules and boards as - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 74
implementation GroupStatusDescriptions[0] contains descriptive text per GroupOperationalStatus[0]: • Memory collection status: OK • Memory collection status: Degraded • Memory collection status: Unknown Table 7-10 Memory Collection Status RedundancyStatus from HP_MemoryRedundanc ySet 'worst - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 75
HP_HostedMemoryRedundancySet represents an association between HP_MemoryRedundancySet and the computer system that contains this redundancy set. Table 7-14 Class: HP_HostedMemoryRedundancySet Property name CIM_OwningCollectionElement Property implementation 6BSystem memory 75 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 76
Property implementation ref: HP_MemoryModule ref: HP_Memory 7-3-12 HP_ MemoryModuleSlot The class HP_MemoryModuleSlot represents memory module slots on Integrity Servers. There is an instance of this class for each memory module socket in the system (whether the slot is occupied or not). Table - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 77
index and the DIMM slot physical location. The memory socket number where the memory slot is located. 7-3-13 HP_MemoryBoardSlot The class HP_MemoryBoardSlot represents memory board slots on Integrity Servers. There is an instance of this class for each memory board slot in the system (whether the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 78
implementation HPQ:HP_MemoryBoardSlot:x, where x is the board/cartridge number. A string describing the memory board physical location. A string describing the memory board physical location. 1 (Other) A string describing the memory board physical location. The board/cartridge number where the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 79
HP_MemoryModuleSlot 7-3-17 HP_MemoryModuleSlotLocation The class HP_MemoryModuleSlotLocation extends the HP_Location class and represents memory module slot locations on Integrity servers. There is an instance of this class for each memory module slot in the system (whether the slot is occupied or - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 80
/cartridge number 7-3-18 HP_MemoryBoardSlotLocation The class HP_MemoryBoardSlotLocation extends the HP_Location class and represents memory board slot locations on Integrity Servers. There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 81
module slot (HP_MemoryModuleSlot) with its corresponding location (HP_MemoryModuleSlotLocation). There is an instance of this class for each memory module slot in the system (whether the slot is occupied or not). Table 7-23 Class: HP_MemoryModuleSlotElementLocation Properties CIM_ElementLocation - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 82
class HP_SystemMemoryBoardSlot represents an association between HP_MemoryBoardSlot and HP_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). Table 7-26 Class: HP_SystemMemoryBoardSlot Properties CIM_Component - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 83
7-26 Class: HP_SystemMemoryBoardSlot Properties HP_SystemMemoryBoardSlot GroupComponent PartComponent Property implementation ref: HP_ComputerSystemChassis ref: HP_MemoryBoardSlot 7-4 Supported indications There are no indications specific to the system memory profile implementation. 6BSystem - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 84
This provider implements the profiles listed to support PCI devices installed in Integrity servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles Provider Installation Files • DMTF PCI Device Profile • DMTF - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 85
PCI device Vendor ID as described in the configuration registers for this PCI device 8-3-2 HP_PCIBridge HP_PCIBridge is used to model PCI bridge devices on Integrity servers. There is an instance of this class for each logical PCI bridge device that has been detected in the system. Table 8-3 Class - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 86
Table 8-3 Class: HP_PCIBridge Property name ElementName CIM_ManagedSystemElement Name CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_PCIController CIM_PCIDevice BusNumber DeviceNumber - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 87
describing the physical location of the PCI device. 2 (Not Applicable) 9 (Module/Card) HPQ:PCICard False 8-3-4 HP_PCISlot HP_PCISlot represents PCI device slots on Integrity Servers. There is an instance of this class for each PCI slot in the system (whether the slot is occupied or not). Table - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 88
a PCI Express slot, otherwise this property is not set The physical PCI slot number • True-if slot supports PCI hot plug operations • False-if slot does not support PCI hot plug operations HPQ:PCICard 8-3-5 HP_PCICardInSlot HP_PCICardInSlot is used to represent an association between HP_PCICard and - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 89
Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_PCIDevice 8-3-9 HP_Location HP_Location is used to model PCI slot locations on Integrity Servers. The Windows-specific implementation class is HP_PCISlotLocation. 7BPCI Device 89 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 90
is HP_PCISlotElementLocation. Table 8-11 Class: HP_ElementLocation Property name Element PhysicalLocation Property implementation References CIM_ManagedElement References CIM_Location 8-4 Supported indications There are no indications specific to the PCI device implementation. 7BPCI Device 90 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 91
HPWmiMgmtProc.dll • HPWmiMgmtProcLite.mof 9-2 Use cases For use cases, see the HP Management Processor (MP) Lite Profile. 9-3 Class implementations The following classes are implemented for Integrity server platforms where available. The following classes describe management processor systems and - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 92
Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) • Integrated Lights Out 2 (ILO2) Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor (MP) Lite Profile for specific descriptions of when each value is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 93
/disabled MP 12 (Not Applicable) 2 (Enabled) HP_ManagementProcessor Product name of the management processor Examples: • Remote Insight Board Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) • Integrated Lights Out 2 (ILO2) 14 (Management) 4 (Enabled) 8BManagement Processor Lite 93 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 94
Integrated Lights Out Controller (iLO)) • 4 (Embedded Integrated Lights Out Controller 2 (iLO 2)) • 5 (Embedded Integrity Management Processor) • 6 (Embedded Integrity Integrated Lights Out Controller (iLO)) • 7 (Embedded Integrity Integrated indicating the protocols supported by the -specific - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 95
Remote Insight Board Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) • Integrated Lights Out 2 (ILO2) 2 (OK) Management Processor Firmware MajorVersion and MinorVersion properties. Hewlett-Packard 10 (Firmware) HP Management Processor Firmware HPQ:xxx, where xxx represents the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 96
Collection 1 HPQ:HP_MPCollection:001 Management Processor Collection 1 Describes the group operational status of the management processor collection (refer to HP Management Processor (MP) Lite Profile). The group operational status represents the 'worst-of' algorithm for all individual MP statuses - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 97
Table 9-4 Class: HP_MPCollection Property name GroupStatusDescription HP_MPCollection Property implementation GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: • Aggregate Management Processor Collection Status: Unknown • Aggregate Management Processor Collection Status: OK • Aggregate - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 98
9-3-7 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a management processor to its corresponding firmware. The Windows-specific implementation class is HP_MPElementFirmwareIdentity. The following properties are implemented. Table 9-8 Class: CIM_ElementSoftwareIdentity - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 99
processor to its corresponding installed firmware. The Windows-specific implementation class is HP_MPInstalledFirmwareIdentity. The following properties are : HP_ManagementProcessor ref: HP_MPFirmware 9-4 Supported indications There are no indications specific to the management processor profile - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 100
10 SEL Record Log 10-1 Overview This provider supports the IPMI System Event Log (SEL) on Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 10-1 Overview Implemented Profiles Provider Installation Files • HP Record Log Profile - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 101
events are the events with alert level 3 or above. (HPQ_CommonLogEntry instances) 2 (Normal) 2 (Wraps When Full) The IML entries will fill up available IML non-volatile memory space until no room is left. The oldest log entries will then be deleted as needed to create room for new log entries. HPQ - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 102
currently used. Table 10-3 Implemented Methods for HP_CommonRecordLog Class Method Name ClearLog RepairAll Method Implementation See HP Record Log profile (P00109) See HP Record Log profile (P00109) 10-3-2 HP_CommonLogEntry HP_CommonLogEntry extends the class CIM_ LogEntry to model logs records - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 103
Raw SEL event as logged by the firmware (16 bytes if no timestamp entry, else 32 bytes) 12 (IPMI SEL) 2 (None) IPMI SEL log event update time stamp Number 4 (Degraded/Warning) • 7 (Critical) • For Windows Server 2003 64-bit: 70 • For Windows Server 2008 64 bit: 77 • Unknown: 0 System serial number - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 104
name ServerHardwareArchitecture LoggerType Property implementation • 0 (Unknown) • 8 (IA-64) 2 (Server) Table 10-5 Implemented Methods for HP_CommonLogEntry Class Method Name Repair Method Implementation Refer to HP Record Log profile (P00109) 10-3-3 HP_LogManagesRecord HP_ LogManagesRecord - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 105
10-4 Supported indications There are no indications specific to the profile registration profile implementation. 9BSEL Record Log 105 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 106
11-1 Overview Implemented Profiles Provider Installation Files • HP Blade System Lite Profile 1.0 • HPWmiBlade.DLL • HPWmiBlade.mof 11-2 Use cases For use cases, see the HP Blade System Lite Profile. 11-3 Class implementations The following classes are implemented for Integrity c-Class blade - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 107
status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 108
HP_GroupSystemSpecificCollection Caption GroupOperationalStatus Property implementation A collection of server blade enclosures with group aggregate status Server Blade Enclosure Collection HPQ:HP_BladeEnclosureCollection:001 Server Blade Enclosure Collection Describes the group operational status - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 109
Property implementation ref: HP_ComputerSystem (the blade enclosure computer system) ref: HP_ComputerSystem (the blade servers computer system) 11-3-4 HP_MemberOfBladeEnclosureCollection HP_MemberOfBladeEnclosureCollection extends the class CIM_MemberOfCollection and associates the enclosure - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 110
describes blade enclosure firmware. The Windows-specific implementation class is HP_BladeEnclosureFW. The following table Server Blade Enclosure Firmware HP Server Blade Enclosure Firmware OA If enclosure name exists: HP BladeSystem c-Class enclosure otherwise: HP - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 111
Hewlett-Packard 10 (Firmware) HP Server Blade Enclosure Firmware HPQ:OA CIM:SoftwareFamily 11-3-7 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a blade enclosure to its corresponding firmware. The Windows-specific implementation class is HP_BladeEnclosureElementFWIdentity. The - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 112
CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System InstalledSoftware Property implementation ref: HP_BladeEnclosureCS ref: HP_BladeEnclosureFW 11-4 Supported indications There are no indications specific to the blade system profile implementation. 10BBlade System Lite 112 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 113
, and the following files are installed by this provider. Table 12-1 Overview Implemented Profiles Provider Installation Files HP Ethernet Teaming 1.0 • HPWinEthAdapterCollection.dll • HPWinEthBootcodeVersion.dll • HPWinEthBootcodeVersionToPort.dll • HPWinEthDevice.dll • HPWinEthernetPort - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 114
Table 12-1 Overview Provider Installation Files continued • HPWinEthernetPort.mof • HPWinEthernetPortStatistics.mof • For use cases, see the HP Ethernet Teaming Profile. 12-3 Class implementations The following classes are implemented for Integrity server platforms. The following classes describe - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 115
otherwise 2 (OK) if port has link, 6 (Error) otherwise 2 (Enabled). Disabled ports are not modeled 5 (Not Applicable) HP_WinEthernetPort System GUID for the port HPQ: Spare Part Number Spare part number HP_ ComputerSystem.SystemCreationClassName HP_ComputerSystem.Name Port Type. See CIM_EthernetPort - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 116
MinNumberNeeded OtherLoadBalanceAlgorithm RedundancyStatus Property implementation Device Name (for example HP Network Team #1) Local Area Connection # (for example Local Area Connection #10) Same as Caption System GUID for the team. • 0 (None) • 1 (Other) • 3 (Round Robin) Number of - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 117
Key:Collection Key:Member HP_EthernetTeamMember MemberOperationalStatus MemberStatusDescriptions Property implementation ref: HP_EthernetTeam ref:HP_EthernetPort • 2 (OK) • 3 (Degraded) • 6 (Error) See the HP Ethernet Teaming Profile. Example: Degraded (Fast Path) 11BEthernet Teaming 117 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 118
• For Ethernet Teams, same as associated HP_WinEthRedundancySet.Caption • For Ethernet Ports, same as associated HP_WinEthernetPort.Caption Local Area Connection # Same as Caption System GUID for the Ethernet LAN Endpoint • 5 (OK) • 15 (Degraded/Warning) • 20 (Major Failure) 11BEthernet Teaming 118 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 119
VLANId VLANName Property implementation • 2 (OK) • 3 (Degraded) • 6 (Error) 2 (Enabled) 12 (Not Applicable) HP_WinEthLANEndpoint HP_ComputerSystem.CreationClassName Name of Server GUID 6 (Ethernet CSMA/CD) Current MAC Address Max Frame Size in bits VLAN Identifier, if LAN Endpoint is a VLAN, not - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 120
12-3-8 HP_EthernetTeamToLANEndpoint HP_ EthernetTeamToLANEndpoint associates Ethernet Teams to Ethernet LAN Endpoints. The Windows implementation class is HP_WinEthRedundancySetToLANEndpoint. Table 12-9 Class: HP_EthernetTeamToLANEndpoint Property name CIM_Dependency Key:Antecedent Key:Dependent - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 121
12-3-11 HP_EthernetStatistics The following table lists the property implementation for HP_EthernetPortStatistics. The Windows implementation class is HP_WinEthernetPortStatistics. 11BEthernet Teaming 121 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 122
same as associated HP_WinEthRedundancySet.Caption • For Ethernet Ports, same as associated HP_WinEthernetPort.Caption Local Area Connection # Same as Caption System GUID of the associated Ethernet Port or LAN Endpoint 0 Time of current statistics Total number of bytes received Total number of bytes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 123
Table 12-13 Class: HP_EthernetPortStatisticalData Property name CIM_ElementStatisticalData Key:ManagedElement Key:Stats HP_EthernetPortStatisticalData Property implementation ref:HP_EthernetPort ref:HP_EthernetStatistics 12-3-13 HP_EthernetLANEndpointStatisticalData - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 124
12-3-15 HP_EthernetMemberOfCollection HP_EthernetMemberOfCollection associates Ethernet Ports and Ethernet Teams to the Ethernet Collection. The Windows implementation class is HP_WinEthMemberOfCollection. Table 12-16 Class: HP_EthernetMemberOfCollection Property name CIM_MemberOfCollection Key: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 125
CIM_IPProtocolEndpoint IPv4Address SubnetMask Property implementation System GUID for the associated Ethernet LAN Endpoint, (Enabled) 12 (Not Applicable) HP_WinEthIPProtocolEndpoint HP_WinComputerSystem Name of Server 4096 (IPv4) IPV4 Address Subnet Mask 12-3-18 HP_EthIPHostedAccessPoint - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 126
property implementation for CIM_SoftwareIdentitiy, The Windows-specific implementation classes are HP_WinEthBootcodeVersion and HP_WinEthPXEVersion. Ethernet Port Same as associated Ethernet Port PCI vendor ID System GUID for the associated Ethernet Port Same as associated Ethernet Port Same - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 127
[0] HP_WinEthLocation Property implementation Same as associated ethernet port Same as associated ethernet port Same as caption Local Area Connection # System GUID for the associated Ethernet Port PCI Bus:Device:Function 15 (PCI Bus:Device:Function) 0 (Slot) or 1 (Mezzanine Slot) or 2 (Interconnect - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 128
Ethernet Indication settings. The Windows implementation class is HP_WinEthEventSettings. Table 12-24 Class: HP+EthEventSettings Property name CIM_SettingData Caption Description ElementName Key:InstanceId HP_EthEventSettings HP_WinEthEventSettings ActiveAdapterCountChanged FloodThreshold - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 129
Table 12-24 Class: HP+EthEventSettings Property name MonitorLANEndpoints utilization. Default 200. 12-4 Supported indications The following indications are implemented for Integrity server platforms where available. System Ethernet Provider Name Property implementation GUID string generated at - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 130
View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log build> 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 131
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 (Information) Time of indication The Ethernet Team has transitioned from - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 132
2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer Property name CIM_Indication IndicationIdentifier Property implementation GUID string generated at indication 11BEthernet Teaming - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 133
Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 134
Restored Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement AlertingElementFormat Property implementation GUID string generated at indication 2 (Information) Time of indication The Ethernet Team has transitioned - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 135
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 136
RecommendedActions[] SystemCreationClassName SystemName Property implementation GUID string generated at indication 6 ( Lost Connectivity Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 137
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 138
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 (Information) Time of indication If the Network Interface is an Ethernet - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 139
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 140
OSType OSVersion ProviderVersion SystemFirmwareVersion Property implementation GUID string generated at indication 2 Alert) 10 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 141
[2] VariableName[3] VariableTypes[3] VariableValue[3] VariableName[4] VariableTypes[4] VariableValue[4] ImpactedDomain BladeBay * BladeName * EnclosureName * Property implementation Platform GUID of the computer system generating the indication Model name of the computer system generating the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 142
Connect environment Table 12-32 Optional HP_AlertIndication: Team EventCategory EventSubCategory Property implementation GUID string generated at indication Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 143
Table 12-32 Optional HP_AlertIndication: Team Member Role Change Property name NetworkAddresses major>.. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 144
Table 12-32 Optional HP_AlertIndication: Team Member EventCategory EventSubCategory NetworkAddresses Property implementation GUID string generated at indication 2 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 145
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 146
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 147
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 3 (Degraded/Warning) Time of indication An existing network interface - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 148
Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for > 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 149
AlertType Event Id Provider Name RecommendedActions[] SystemCreationClassName SystemName HP_AlertIndication Summary EventCategory EventSubCategory Property implementation GUID string generated at indication 2 (Information) Time of indication A new network interface is available. This - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 150
2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime Property implementation GUID string generated at indication 2 (Information - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 151
13 Ethernet View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 152
HP_AlertIndication: Fatal Error Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingManagedElement Property implementation GUID string generated at indication 2 (Information) Time of indication A fatal error occurred. WBEM path - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 153
) 2 (Communications Alert) 1 Ethernet Contact HP Support. CreationClassName of the computer system generating the indication build> 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 154
AlertType Event Id Provider Name RecommendedActions[] Property implementation GUID string generated at indication 2 (Information) Time of of this event are not a cause for concern. Numerous instances of this event indicate a serious issue. Contact HP Support. 11BEthernet Teaming 154 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 155
system generating the indication in the format, .. 2.2.0.0 Firmware version of the computer system generating the indication Platform GUID of the computer system generating the indication Model name of the computer system generating the indication Product ID of the computer - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 156
Table 12-39 Optional HP_AlertIndication: Warning Property name SystemVirtualUUID Property implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment 11BEthernet Teaming 156 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 157
following files are installed by this provider. Table 13-1 Overview Implemented Profiles Provider Installation Files • HP Smart Array Profile (P00121) • HPWMISA.dll • functionality is not supported by this provider. This is in accordance with the SNIA profiles, because HP does not advertise - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 158
Failure • Physical Drive Degraded/Failed 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSA_ArraySystem Controller Serial Number Other • Dedicated[0]: 3 (Storage) • Dedicated[1]: 15 (Block Server) Other Vendor Specific Name Controller Serial Number See HP Smart Array Profile 12BSmart Array 158 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 159
Controller Serial Number Other Dedicated[0] 0 (Not Dedicated) See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 12BSmart Array 159 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 160
NumberOfPorts RebuildPriority Property implementation See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 13-3-3 HPSA_StorageVolume - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 161
or above • False - RAID 0 Total Number of blocks on the volume. • 0 (RAID 0) • 1 (RAID 1+0, RAID 5) • 2 (RAID 6) 2 (VPD83NAA6) See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile Volume status. DMTF defined value is populated in index[0] and extended status is poplulated - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 162
HPSA_ArraySystem.Name Number of service hours logged for the drive See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile 13 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 163
: • 2 (None) • 11 (Rebuild - disk drive is currently rebuilding data) Total number of blocks on disk drive Set to True Total service hours reported disk drive 13-3-6 HPSA_DiskDriveFirmware HPSA_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 164
Table 13-7 Class: HPSA_DiskDriveFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_LogicalElement Caption Description CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 165
Table 13-8 Class: HPSA_PhysicalPackage (CIM_PhysicalPackage) Property name Manufacturer Model PartNumber SerialNumber Tag Version CIM_PhysicalPackage RemovalConditions HPSA_PhysicalPackage Property implementation Controller vendor string Controller model string N/A-Not Available for this - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 166
Table 13-9 Class: HPSA_ArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name HPSA_ ArrayControllerPhysicalPackage Property implementation 13-3-9 HPSA_DiskPhysicalPackage HPSA_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 167
the port and is the box number Port: Box: , where is the port and is the box number HPSA_StorageEnclosure Enclosure vendor string e.g HP For example, N/A if not available Enclosure model string For example, PROLIANT 6L6I For example, N/A if not available N/A-Not Available in this - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 168
, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows. • Index[0] HPSA_StorageEnclosureProcessor Opaque Key Other 2 (Other) Other Vendor Specific Name SDE-Indicates Storage Device Enclosure Port Number:BoxNumber - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 169
Table 13-13 Class: HPSA_PortController (CIM_PortController) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 170
Table 13-14 Class: HPSA_DAPort (CIM_DAPort) Property name CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSA_DAPort Property implementation 2 (Enabled) - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 171
Table 13-15 Class: HPSA_SPIPort (CIM_SPIPort) Property name CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort CIM_SPIPort HPSA_SPIPort Property implementation HPSA_SPIPort Opaque key HPSA_ArraySystem HPSA_ArraySystem.Name 13-3-15 HPSA_Firmware HPSA_Firmware represents - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 172
Table 13-17 Class: HPSA_EnclosureFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_LogicalElement Caption Description CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 173
managed by this pool 13-3-19 HPSA_MediaAccessStatData HPSA_MediaAccessStatData represents the Monitoring and Performance data counters on HP Disk Drives. Table 13-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData) Property name CIM_ManagedElement Property implementation 12BSmart Array - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 174
HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 175
Table 13-21 Class: HPSA_StorageSetting (CIM_StorageSetting) Property name CIM_ManagedElement ElementName CIM_SettingData InstanceID CIM_StorageSetting ChangeableType DataRedundancyGoal DataRedundancyMax DataRedundancyMin DeltaReservationGoal DeltaReservationMax DeltaReservationMin - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 176
Table 13-22 Class: HPSA_DriveCage (CIM_PhysicalPackage) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber Tag SerialNumber Version CIM_PhysicalPackage RemovalConditions HP_DriveCage BackplaneSpeed DriveBays - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 177
Table 13-23 Class: HPSA_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name EnabledDefault RequestedState CIM_ServiceAccessPoint CreationClassName Name SystemCreationClassName SystemName CIM_ProtocolEndpoint ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType OtherConnectionType Role - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 178
MaxUnitsControlled CIM_ SCSIProtocolController HPSA_ SCSIProtocolController Property implementation HPSA_SCSIProtocolController Opaque key HPSA_ArraySystem HPSA_ArraySystem.Name 32 13-3-24 HPSA_RedundancySet HPSA_RedundancySet represents controller redundancy if there is more than one - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 179
Table 13-26 Class: HPSA_StorageRedundancySet (CIM_StorageRedundancySet) Property name CIM_ManagedElement ElementName CIM_Collection CIM_SystemSpecificCollection InstanceID CIM_RedundancySet LoadBalanceAlgorithm MaxNumberSupported MinNumberNeeded RedundancyStatus TypeOfSet[0] - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 180
13-3-27 HPSA_DriveCageLocation HPSA_DriveCageLocation represents a location string for the drive cage. Table 13-28 Class: HPSA_DriveCageLocation (HP_Location) Property name CIM_ManagedElement Caption Description ElementName CIM_Location Name PhysicalPosition HP_Location ElementLocationTag - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 181
Table 13-29 Class: HPSAArraySystemLocation (HP_Location) Property name ElementName CIM_Location Name PhysicalPosition HP_Location ElementLocationTag ElementLocationTagDesc LocationInformation[0] LocationInfoDesc[0] HPSA_ArraySystemLocation Property implementation Controller name and location - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 182
in ElementLocationTagDesc. • SCSI ID of Disk Drive-When 'SCSI ID' is specified in ElementLocationTagDesc • 20 (Bay)-When firmware supports Bay numbering • 21 (SCSI ID) 13-3-30 HPSA_ArrayControllerLocation HPSA_ArrayControllerLocation represents a location string for the array controller. Table 13 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 183
HPSA_StorageCapabilities HPSA_StorageCapabilities represents the possible capabilities of a Storage Pool. Table 13-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities) Property name CIM_ManagedElement ElementName CIM_Capabilities InstanceID CIM_StorageCapabilities Property implementation - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 184
• 2 (When number of drives > 3) • 0 (When number of drives 3) 0 13-3-32 HPSA_Product HPSA_Product represents the top level marketing information for the Array System. Table 13-33 Class: HPSA_Product (CIM_Product) Property name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 185
CIM_Product) Property name IdentifyingNumber Name Vendor Version HPSA_Product Property implementation Opaque key String representing the Marketing name HP Firmware version of HBA or Storage System 13-3-33 HPSA_StorageEnclosure Location HPSA_StorageEnclosureLocation represents a location string for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 186
13-3-35 HPSA_StorageVolumeStorageSetting (Association) Table 13-36 Class: HPSA_StorageVolumeStorageSetting (CIM_ElementSettingDate) Property name ManagedElement SettingData IsCurrent IsDefault Property implementation HPSA_StorageVolume HPSA_StorageSetting 1 (Set to Is Current) 1 (Set to Is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 187
Table 13-40 Class: HPSA_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_SCSIProtocolController 13-3-40 HPSA_ArraySystemPortController (Association) Table 13-41 Class: HPSA_ArraySystemPortController ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 188
13-3-44 HPSA_ArraySystemSPIPort (Association) Table 13-45 Class: HPSA_ArraySystemSPIPort (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_SPIPort. 13-3-45 HPSA_ArraySystemDAPort (Association) Table 13-46 Class: HPSA_ArraySystemDAPort ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 189
13-3-49 HPSA_ArraySystemArrayController (Association) Table 13-50 Class: HPSA_ArraySystemArrayController (CIM_ComponentCS) Property name GroupComponent PartComponent Property implementation HPSA_ArraySystem HPSA_ArrayController 13-3-50 HPSA_StorageEnclosureStorageEnclosureProcessor (Association) - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 190
Table 13-54 Class: HPSA_PhysicalPackageArrayControllerPhysicalPackage (CIM_Container) Property name GroupComponent PartComponent Property implementation HPSA_PhysicalPackage HPSA_ArrayControllerPhysicalPackage 13-3-54 HPSA_PhysicalPackageDiskPhysicalPackage (Association) Table 13-55 Class: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 191
13-3-58 HPSA_PrimordialPoolStorageExtent (Association) Table 13-59 Class: HPSA_PrimordialPoolStorageExtent (CIM_ConcreteComponent) Property name GroupComponent PartComponent Property implementation HPSA_PrimordialPool HPSA_StorageExtent 13-3-59 HPSA_StorageSpecificCollectionArraySystem ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 192
Table 13-63 Class: HPSA_ArraySystemFirmware (CIM_InstalledSoftwareIdentity) Property name InstalledSoftware System Property implementation HPSA_Firmware HPSA_ArraySystem 13-3-63 HPSA_SCSIProtocolControllerStorageVolume (Association) Table 13-64 Class: HPSA_SCSIProtocolControllerStorageVolume ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 193
13-3-66 HPSA_DiskDriveDiskDriveFirmware (Association) Table 13-67 Class: HPSA_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSA_DiskDriveFirmware HPSA_DiskDrive • ElementSoftwareStatus[0]: 2 (Current) • - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 194
Table 13-71 Class: HPSA_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Antecedent Dependent SpaceConsumed Property implementation HPSA_PrimordialPool HPSA_StoragePool Bytes consumed by storage pool 13-3-71 HPSA_SpareExtentStorageExtent (Association) Table 13-72 Class: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 195
13-3-75 HPSA_SPIPortSCSIProtocolEndpoint (Association) Table 13-76 Class: HPSA_SPIPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Antecedent Dependent Property implementation HPSA_SPIPort HPSA_SCSIProtocolEndpoint 13-3-76 HPSA_StorageGroupHostedCollection (Association) - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 196
Table 13-80 Class: HPSA_DiskDriveMediaAccessStatData (CIM_ElementStatisticalData) Property name Stats Property implementation HPSA_MediaAccessStatData 13-3-80 HPSA_ArrayControllerPhysicalPackageArrayControllerLo cation (Association) Table 13-81 Class: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 197
Property implementation HPSA_StorageEnclosure HPSA_StorageEnclosureLocation 13-4 Supported indications Table 13-87 HPSA_DeviceIndication: Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 2 (Informational - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 198
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 199
Physical Drive status changed to ERROR Property name CIM_Indication IndicationIdentifier PerceivedSeverity Property implementation GUID string generated at indication Severity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 200
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 201
IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName Property implementation GUID string generated at indication 2 (Informational) Time of indication Physical Drive status has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 202
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 203
CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Property implementation GUID string generated at indication 5 (Major) Time of indication Physical Drive status has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 204
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 205
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 2 (Informational) Time of indication Logical Drive status has now - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 206
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 207
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 5 (Major) Time of indication Logical Drive Status has changed - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 208
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 209
ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Logical Drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost. WBEM - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 210
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 211
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Status has changed - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 212
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]:CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 213
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 5 (Major) Time of indication Array Controller Status has changed - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 214
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 215
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller Redundancy state has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 216
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 217
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller has detected that - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 218
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 219
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 2 (Info) Time of indication Controller has detected that Redundancy - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 220
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 221
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 2 (info) Time of indication Array Controller Battery Status has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 222
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 223
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory Property implementation GUID string generated at indication 3 (Warning) Time of indication Controller Battery Status is set - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 224
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 225
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 5 (major) Time of indication Controller Battery Status set to - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 226
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 227
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Cache Status has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 228
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 229
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 2 (Info) Time of indication Array Controller Cache Status is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 230
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 231
Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 3 (Warning) Time of indication Array Controller Cache Status is set to a status of Permanently Disabled. Controller has detected a problem with the cache and has disabled - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 232
of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: CacheSizeTotal • VariableNames[2]: CacheSerialNumber • VariableTypes - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 233
Summary EventCategory ProbableCause NetworkAddresses Property implementation GUID string generated at indication 3 (Warning ) 5 (Device Alert) 1502 SmartArray Check status of all enclosure power supplies. Problem may be caused by a failed power supply. Name of the computer system generating - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 234
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 235
HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion SystemSerialNumber SystemProductID SystemModel Property implementation GUID string generated at indication 2 (Info) Time of indication Power Supply Status changed to - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 236
changed to Redundant Degraded Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement Property implementation GUID string generated at indication 3 (Warning) Time of indication Power Supply Status changed to a status - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 237
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 238
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Temperature sensor Status changed to - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 239
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 240
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType Property implementation GUID string generated at indication 3 (Warning) Time of indication Temperature sensor Status changed to Warning - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 241
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 242
HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at indication 5 (major) Time of indication Temperature sensor Status changed to - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 243
HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 244
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 245
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName Property implementation GUID string generated at indication 3 (Warning) Time of indication Fan Status changed to a status of Degraded. Enclosure has detected there may a problem with one or more of the fans. WBEM - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 246
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 247
AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause NetworkAddresses OSType Property implementation GUID string generated at indication 5 (major) Time of indication Enclosure Fan Status changed to a status - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 248
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short description of failure • 3 (Enclosure) for c-Class blade systems • 4 (System - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 249
table details the profiles implemented and files installed by this provider. Table 14-1 Overview Implemented Profiles Requirements Provider Installation Files • HP FC HBA Profile 1.0 • HBAAPI.dll that supports the SNIA Common HBA API, Version 2.18 • Dll(s) • HPWMISCSI.dll • HPWMISCSIEventMsg.dll - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 250
Figure 14-1 Instance diagram for a single HBA with two controllers with one port on each controller 13BFC HBA 250 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 251
14-2-1 Get statistics for each Fibre Channel port 1. For each instance of HPFCHBA_ComputerSystem, find the corresponding instance of the associations HPFCHBA_ComputerSystemFCPort. 2. For each association of HPFCHBA_ComputerSystemFCPort, get the corresponding instance of HPFCHBA_FCPort. 3. For each - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 252
7. For each instance of association HPFCHBA_SoftwareIdentityDrvPortController, get the corresponding instance of HPFCHBA_SoftwareIdentityDrv. The VersionString property contains the driver version. Other properties of interest are Description, ElementName, and Manufacturer. 8. For each instance of - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 253
Figure 14-3 Discover HBA topology and attributes 14-3 Class implementations 14-3-1 HPFCHBA_ComputerSystem HPFCHBA_ComputerSystem is used to identify classes that represent the all Fibre Channel ports. Table 14-2 Class: HPFCHBA_ComputerSystem Property name CIM_ManagedElement Property - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 254
(OK) • 3 (Degraded) • 6 (Error) • Unknown • Other • OK • Degraded • Error 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPFCHBA_ComputerSystem Other 0 HPQ:GUID 85408DBD-6A39-41CD-9E5A-357AEA130BBF 14-3-2 HPFCHBA_FCPort HPFCHBA_FCPort is used to represent a Fibre Channel port device. Table 14 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 255
2 (OK-Online) • 6 (Error) • 10 (Stopped) • 11 (In Service) • Unknown • OK-Online • Offline • Bypassed • Diagnostics • Link down • where nodeWWN is the node's WWN and portWWN is the port's WWN. HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node's WWN. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 256
) 4 (FC) PortWWN Port number Port maximum frame size Array of port active FC4 type bits Array of port supported FC4 type bits 14-3-3 HPFCHBA_PortController HPFCHBA_PortController is a logical device corresponding to a hardware network port controller. Table 14-4 Class: HPFCHBA_PortController - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 257
(Not Applicable) 12 (Not Applicable) HPFCHBA_PortController NodeWWN:SerialNumber HPFCHBA_ComputerSystem HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node PacketsReceived Property implementation Product name HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 258
InstanceID CIM_LogicalPortGroup Name NameFormat Property implementation Grouping of all FC Ports for this HBA Logical Port Group Logical Port Group HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_L ogicalPortGroup, where nodewwn is the node's WWN. NodeWWN WWN 13BFC HBA 258 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 259
(Other) 2 (OK) 3 (Degraded) 6 (Error) HPFCHBA_PhysicalPackage Manufacturer Model Location; PCI Slot x where x is the PCI slot number Serial Number HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn where nodewwn is the node's WWN. Board Version or N/A when not available 2 (Not Applicable - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 260
Device Driver, where product name is the product name of the HBA. FC HBA Driver NodeWWN FC HBA Driver 2 (Driver) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_S oftwareIdentityDrv where nodewwn is the node's WWN. Manufacturer Driver version 14-3-9 HPFCHBA_FirmwareIdentityFW - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 261
for Product Name, where product name is the product name of the HBA. FC HBA Firmware NodeWWN FC HBA Firmware 10 (firmware) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_Fi rmwareIdentityFW, where nodewwn is the node's WWN Manufacturer Serial number Firmware version 14-3-10 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 262
FC HBA Option ROM 11 (bios/fc) HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_Fi rmwareIdentityBIOS, where is the node's WWN Manufacturer BIOS Version as reported by HBA HP BIOS UNKNOWN Serial Number 0 0 0 14-3-11 HPFCHBA_SCSIProtocolController HPFCHBA_SCSIProtocolController - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 263
CIM_ProtocolController MaxUnitsControlled CIM_SCSIProtocolController Property implementation HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn NodeWWN 2 (Enabled) 12 (Not Applicable) HPFCHBA_ComputerSystem HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn, where nodewwn is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 264
FC HBA Consolidated Status A consolidated OperationalStatus for all FCHBA_ComputerSystem instances FC HBA Consolidated Status HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:HPFCHBA_GroupSystemSpecificColle ction • 0 (Unknown) • 1 (Other) • 2 (OK) • 3 (Degraded) • 6 (Error) • Unknown • Other • OK - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 265
14-3-15 HPFCHBA_ComputerSystemPortController HPFCHBA_ComputerSystemPortController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_PortController. Table 14-16 Class: HPFCHBA_ComputerSystemPortController Property name CIM_Component CIM_SystemDevice - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 266
Table 14-18 Class: HPFCHBA_ComputerSystemLogicalPortGroup Property name Dependent Property implementation ref:HPFCHBA_LogicalPortGroup 14-3-18 HPFCHBA_ComputerSystemSoftwareIdentityDrv HPFCHBA_ComputerSystemSoftwareIdentityDrv is used to represent an association between HPFCHBA_ComputerSystem and - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 267
Table 14-21 Class: HPFCHBA_FCPortFCPortStatistics Property name CIM_ElementStatisticalData HPFCHBA_FCPortFCPortStatistics ManagedElement Stats Property implementation ref:HPFCHBA_FCPort ref:HPFCHBA_FcPortStatistics 14-3-21 HPFCHBA_FCPortLogicalPortGroup HPFCHBA_FCPortLogicalPortGroup is used to - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 268
Table 14-24 Class: HPFCHBA_SCSIProtocolControllerFCPort Property name CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerForPort HPFCHBA_SCSIProtocolControllerFCPort Antecedent Dependent Property implementation ref:HPFCHBA_SCSIProtocolController ref:HPFCHBA_FCPort 14-3-24 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 269
HPFCHBA_SoftwareIdentityDrvPortController is used to represent an association between HPFCHBA_PortController and HPFCHBA_SoftwareIdentityDrv. Table 14-27 Class: HPFCHBA_SoftwareIdentityDrvPortController Property name CIM_Dependency CIM_ElementSoftwareIdentity - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 270
HPFCHBA_ConcreteIdentity is used to represent an association between CIM_ComputerSystem and HPFCHBA_ComputerSystem. Table 14-32 Class: HPFCHBA_ConcreteIdentity Property name CIM_LogicalIdentity CIM_ConcreteIdentity HPFCHBA_ConcreteIdentity SystemElement SameElement Property implementation ref - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 271
14-3-32 HPFCHBA_GroupHostedCollection HPFCHBA_GroupHostedCollection is used to represent an association between CIM_ComputerSystem and HPFCHBA_GroupSystemSpecificCollection. Table 14-33 Class: HPFCHBA_GroupHostedCollection Property name CIM_Dependency CIM_HostedDependency CIM_HostedCollection - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 272
Property name CIM_ElementLocation HPFCHBA_PhysicalElementLocation Element PhysicalLocation Property implementation ref:HPFCHBA_PhysicalPackage ref:HPFCHBA_Location 14-4 Supported indications There are no indications specific to the Fibre Channel profile implementation. 13BFC HBA 272 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 273
by this provider. Table 15-1 Overview Implemented Profiles Provider Installation Files • HP SAS HBA • HPWMISAS.dll • specific use cases, see HP SAS HBA Profile (P00122). This provider implements a read only version of the profiles referenced. No configuration functionality is supported - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 274
and location For example, HP 8 INT Port SAS/ HP SAS HBA Profile. • 0 (Unknown) • 2 (OK) • 3 (Degraded) • 6 (Error) 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSAS_ArraySystem Controller Serial Number Other • Dedicated[0]: 3 (Storage) • Dedicated[1]: 15 (Block Server) Other Vendor Specific - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 275
Controller Serial Number Other 0 (Not Dedicated) Other Vendor Specific Name Controller Serial Number 15-3-3 HPSAS_StorageVolume HPSAS_StorageVolume represents the Logical of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 2 (Enabled) 5 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 276
) False • True - RAID 1 or above • False - RAID 0 Total Number of blocks on the volume. • 0 (RAID 0) • 1 (RAID 1) 7 (SNVM) See HP SAS HBA Profile See HP SAS HBA Profile Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data • 6 (Error) Corresponding OS name for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 277
2 (OK) • 5 (Predictive Failure) • 6 (Error) 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSAS_DiskDrive Opaque value HPSAS_ArraySystem HPSAS_ArraySystem.Name See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile See HP SAS HBA Profile 0 0 14BSAS HBA 277 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 278
15-3-5 HPSAS_StorageExtent HPSAS_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 15-6 Class: HPSAS_StorageExtent (CIM_StorageExtent) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 279
15-3-6 HPSAS_DiskDriveFirmware HPSAS_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive. Table 15-7 Class: HPSAS_DiskDriveFirmware (CIM_SoftwareIdentity) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 280
Table 15-8 Class: HPSAS_PhysicalPackage (CIM_PhysicalPackage) Property name Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber SerialNumber Tag CIM_PhysicalPackage RemovalConditions HPSAS_PhysicalPackage Property implementation Controller Serial Number HPSAS_PhysicalPackage - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 281
SystemName CIM_Controller CIM_PortController ControllerType OtherControllerType HPSAS_PortController Property implementation Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) HPSAS_PortController - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 282
CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSAS_DAPort Property implementation Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 Port status • 0 (Unknown) • 2 (OK) • 6 (Error) 2 (Enabled) 5 (Not Applicable - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 283
CIM_LogicalElement CIM_StoragePool InstanceID PoolID Primordial RemainingManagedSpace TotalManagedSpace Property implementation Controller name and location: pool identifier. For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial Pool Opaque key Controller serial number TRUE 0 Total raw - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 284
Property implementation Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial CIM_ManagedSystemElement Property implementation Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool 14BSAS - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 285
Table 15-15 Class: HPSAS_StoragePool (CIM_StoragePool) Property name CIM_LogicalElement CIM_StoragePool InstanceID PoolID Primordial RemainingManagedSpace TotalManagedSpace HPSAS_StoragePool Property implementation Opaque key Controller serial number:1 FALSE 0 Total raw space managed by this pool - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 286
ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType OtherConnectionType Role HPSAS_SCSIProtocolEndpoint Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 2 (Enabled) 12 (Not Applicable) HPSAS_SCSIProtocolEndpoint HBA Serial - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 287
SystemCreationClassName SystemName CIM_ProtocolController MaxUnitsControlled CIM_SCSIProtocolController HPSAS_SCSIProtocolController Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Operational status of the controller • 0 (Unknown) • 2 (OK - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 288
implementation SAS HBA Consolidated Status A consolidated OperationalStatus for all HPSAS_ArraySystem instances SAS HBA Consolidated Status Opaque key Consolidated status for all array controllers. See HP SAS HBA profile for details on how this is calculated Description of failure 14BSAS HBA 288 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 289
Port SAS/SATA HBA in Slot 3 Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Opaque key Opaque key PCI Slot number 23 (Adapter) PCI Slot number For example, 3 - PCI Slot 3 3 (PCI Slot - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 290
Pools Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 for internal • For Concrete Pools Controller name and location:Array identifier, for example, HP 8 INT Port SAS/SATA HBA in Slot 3: Storage Pool for internal Opaque key • 0 (When Pool is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 291
HPSAS_Product Property implementation Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3, for internal Opaque key String representing the Marketing Name HP Firmware version of HBA 15-3-24 HPSAS_DriveCage HPSAS_DriveCage represents the drive cage - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 292
Table 15-25 Class: HPSAS_DriveCage (CIM_PhysicalPackage) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name CIM_PhysicalElement CreationClassName Manufacturer Model PartNumber Tag SerialNumber Version CIM_PhysicalPackage RemovalConditions HP_DriveCage BackplaneSpeed - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 293
the port and is the box number Port: Box: , where is the port and is the box number HPSAS_StorageEnclosure Enclosure vendor string • HP • N/A, if not available Enclosure model string • MSA50 -10D25G1 • N/A, if not available N/A-Not Available in this implementation 14BSAS HBA 293 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 294
implementation 2 (Not Applicable) See HP Storage Enclosure Profile 15-3-27 HPSAS_StorageEnclosureProcessor power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: • Index[0]-Enclosure status: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 295
HPSAS_StorageEnclosureProcessor Opaque Key Other 2 (Other) Other Vendor Specific Name SDE - indicates Storage Device Enclosure Vendor:SerialNumber enclosure is attached to For example, HP:2SUJ1029 15-3-28 HPSAS_StorageEnclosureLocation HPSAS_StorageEnclosureLocation represents a - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 296
HPSAS_StorageEnclosureEnclosureLocation (Association) Table 15-32 Class: HPSAS_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property implementation HPSAS_StorageEnclosure HPSAS_StorageEnclosureLocation 15-3-32 HPSAS_ArraySystemStorageEnclosureProcessor (Association) Table - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 297
Table 15-34 Class: HPSAS_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSAS_EnclosureFirmware HPSAS_StorageEnclosureProcessor • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 298
15-3-37 HPSAS_PrimordialPoolNoRaidStorageCapabilities (Association) Table 15-38 Class: HPSAS_PrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Capabilities ManagedElement Property implementation HPSAS_StorageCapabilities HPSAS_PrimordialPoolNoRaid 15-3-38 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 299
Table 15-42 Class: HPSAS_ArraySystemDiskDrive (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSAS_ArraySystem HPSAS_DiskDrive 15-3-42 HPSAS_ArraySystemStorageVolume (Association) Table 15-43 Class: HPSAS_ArraySystemStorageVolume (CIM_SystemDevice) - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 300
15-3-46 HPSAS_ArraySystemPrimordialPoolNoRaid (Association) Table 15-47 Class: HPSAS_ArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) Property name GroupComponent PartComponent Property implementation HPSAS_ArraySystem HPSAS_PrimordialPoolNoRaid 15-3-47 HPSAS_ArraySystemStoragePool ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 301
Table 15-51 Class: HPSAS_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name GroupComponent PartComponent Property implementation HPSAS_Product HPSAS_PhysicalPackage 15-3-51 HPSAS_StoragePoolStorageExtent (Association) Table 15-52 Class: HPSAS_StoragePoolStorageExtent ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 302
Table 15-55 Class: HPSAS_StorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Collection Member Property implementation HPSAS_StorageSpecificCollection HPSAS_ArraySystem 15-3-55 HPSAS_StorageRedundancySetStorageExtent (Association) Table 15-56 Class: - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 303
Table 15-59 Class: HPSAS_FirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSAS_Firmware HPSAS_ArraySystem • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) 15-3-59 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 304
Table 15-63 Class: HPSAS_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Antecedent Dependent SpaceConsumed Property implementation HPSAS_PrimordialPool HPSAS_StoragePool Bytes consumed by storage pool 15-3-63 HPSAS_StorageExtentStorageVolume (Association) Table 15-64 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 305
(Association) Table 15-70 Class: HPSAS_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name AvailableSAP ManagedElement Property implementation HPSAS_SCSIProtocolEndpoint HPSAS_SCSIProtocolController 15-4 Supported indications 14BSAS HBA 305 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 306
SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at the time Alert) 1 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName of - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 307
HWLogicalLocation HWManufacturer HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 308
of the event or time of the indication if event time unknown HP SAS Replace the HBA. Name of the computer system generating the generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 309
AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions Property implementation GUID string generated at the time of indication 2 (Device Alert) 201 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. 14BSAS HBA 309 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 310
computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • VariableNames[0]: FailureDescription • VariableNames[1]: DriveInterface • VariableTypes[0]: 1 (String) • VariableTypes[1]: 4 (uint16 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 311
SystemCreationClassNameEventTime Property implementation GUID string generated at the Time of the event or time of the indication if event time unknownWBEM Path of disk drive HP SAS2 (CIMObjectPath) No action is recommended.5 (Device Alert) Name of the computer system generating the - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 312
SystemGUID VariableNames VariableTypes VariableValues Property implementation HP SAS Redundant power supply status the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 313
REBUILDING Property name CIM_Indication IndicationIdentifier PreceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at the time of indication Severity For example, 2 (Information) Time of - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 314
the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 315
Property name CIM_Indication IndicationIdentifier PreceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID Property implementation GUID string generated at the time of indication 5 (Major) Time of indication A physical drive - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 316
the event or time of the indication if event time unknown HP SAS Replace drive immediately to avoid loss of data. Name of the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 317
AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions Property implementation GUID string generated at the time of indication 2 (Device Alert) 101 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. 14BSAS HBA 317 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 318
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 319
ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at the time of Device Alert) 102 Time of the event or time of the indication if event time unknown HP SAS Check for failed or removed physical drives. Name of the computer system generating the indication - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 320
CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 321
of the event or time of the indication if event time unknown HP SAS Check status of physical drives. Degraded status may be caused generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 322
Summary EventCategory ProbableCause ProbableCauseDescription Property implementation GUID string generated at the time of Alert) 301 Time of the event or time of the indication if event time unknown HP SAS Check status of all enclosure power supplies. Ensure that power supplies have not failed. - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 323
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 324
ProbableCauseDescription ProviderVersion NetworkAddresses OSType Property implementation GUID string generated at the time of 302 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 325
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 326
OSVersion SystemFirmwareVersion SystemSerialNumber Property implementation GUID string generated at the time Device Alert) 303 Time of the event or time of the indication if event time unknown HP SAS Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 327
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 328
307 Time of the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system generating the indication CreationClassName the computer system generating the indication Platform GUID of the computer system generating the indication 14BSAS HBA 328 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 329
sensor status changed to Warning Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A Storage Enclosure Temperature sensor - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 330
308 Time of the event or time of the indication if event time unknown HP SAS Ensure that the system is adequately ventilated. Check for proper room temperature and of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 331
to Critical Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat Property implementation GUID string generated at the time of indication 5 (major) Time of indication A Storage Enclosure - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 332
Time of the event or time of the indication if event time unknown HP SAS Ensure that the system is adequately ventilated. Check for proper room of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 333
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID Property implementation GUID string generated at the time of indication 2 (Info) Time of indication A Storage Enclosure - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 334
the event or time of the indication if event time unknown HP SAS No action is recommended. Name of the computer system the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 335
AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation GUID string generated at the time of indication 3 (Warning) Time of indication A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 336
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 337
Description AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation GUID string generated at the time of indication 5 (major ) 5 (Device Alert) 306 Time of the event or time of the indication if event time unknown HP SAS 14BSAS HBA 337 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 338
indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication FailureDescription 1 (String) Short Description of failure In some cases, the property VariableValues can - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 339
Table 15-88 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HP_HardwareIndication HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 340
are installed by this provider. Table 16-1 Overview Implemented Profiles Provider Installation Files HP SCSI HBA Profile • HPWMISCSI.dll • HPWMISCSIEventMsg. use cases, see HP SCSI HBA Profile (P00123). 16-3 Class implementations The following sections define the supported properties for the SCSI - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 341
) Key: HPSCSI_HBAComputerSystem Key: HBA index Other 0 (Not Dedicated) Direct Attached Storage HBA More info for OperationalStatus result(s) See HP SCSI HBA Profile 16-3-2 HPSCSI_StorageVolume HPSCSI_StorageVolume represents the volumes exposed to the host system. These volumes have a one-to-one - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 342
Table 16-3 Class: HPSCSI_StorageVolume (CIM_ StorageVolume) Property name Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_StorageExtent BlockSize ConsumableBlocks - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 343
Table 16-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name OperationalStatus[0] CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 344
16-3-4 HPSCSI_StorageExtent HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 16-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent) Property name CIM_ManagedElement ElementName CIM_ManagedSystemElement Name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 345
Table 16-6 Class: HPSCSI_DiskDriveFirmwareIdentity (CIM_SoftwareIdentity) Property name ElementName CIM_ManagedSystemElement Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Classifications[0] Description InstanceID Manufacturer IdentityInfoType IdentityInfoValue - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 346
Table 16-7 Class: HPSCSI_HBAPhysicalPackage (CIM_PhysicalPackage) Property name Version Property implementation N/A-Not available in this implementation. 16-3-7 HPSCSI_DiskPhysicalPackage HPSCSI_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 347
implementation Enclosure Serial Number Opaque key N/A - Not available in this implementation 2 (not applicable) See HP Storage Enclosure Profile 16-3-9 HPSCSI_StorageEnclosureProcessor HPSCSI_StorageEnclosureProcessor represents the management processor within a Storage Enclosure. This instance - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 348
supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: • OperationalStatus[0]- applicable) HPSCSI_StorageEnclosureProcessor 2 (Other) Other Vendor Specific Name Enclosure index Other SDE-Indicates Storage - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 349
Table 16-11 Class: HPSCSI_HBAPortController (CIM_PortController) Property name CIM_EnabledLogicalElement EnabledDefault EnabledState RequestedState CIM_LogicalDevice CreationClassName DeviceID SystemCreationClassName SystemName CIM_Controller CIM_PortController ControllerType OtherControllerType - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 350
Table 16-12 Class: HPSCSI_DAPort (CIM_DAPort) Property name CreationClassName DeviceID SystemCreationClassName SystemName CIM_LogicalPort UsageRestriction CIM_DAPort HPSCSI_DAPort Property implementation HPSCSI_DAPort Opaque key HPSCSI_HBAComputerSystem HBA Index 2 (Front-End Only) 16-3-12 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 351
Table 16-13 Class: HPSCSI_SPIPort (CIM_SPIPort) Property name UsageRestriction CIM_SPIPort MaxDataWidth MaxTransferRate Property implementation 3 (Back-end Only) Max bus width (bits) Max rate in bits per second 16-3-13 HPSCSI_HBAFirmwareIdentity HPSCSI_HBAFirmwareIdentity represents the firmware - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 352
represents the monitoring and performance data counters on HP disk drives. Table 16-16 Class: SCSIID:0) Opaque key 0 See HP SCSI HBA Profile P00123. See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 See HP SCSI HBA Profile P00123 15BSCSI - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 353
implementation Serial number if known Opaque key N/A-Not available in this implementation 2 (Not Applicable) See HP Storage Enclosure profile See HP Storage Enclosure profile 16-3-17 HPSCSI_HBASCSIProtocolEndpoint HPSCSI_HBASCSIProtocolEndpoint represents an access point to storage resources for - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 354
Table 16-18 Class: HPSCSI_HBASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name ElementName CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault RequestedState CIM_ServiceAccessPoint CreationClassName Name SystemCreationClassName SystemName - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 355
Table 16-19 Class: HPSCSI_DASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Name SystemCreationClassName SystemName CIM_ProtocolEndpoint ProtocolIFType CIM_SCSIProtocolEndpoint ConnectionType Role Property implementation HBA Index HPSCSI_HBAComputerSystem HBA index 0 (Unknown) 3 ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 356
GroupStatusDescriptions Property implementation HP consolidated status for all SCSI HBAs Consolidated OperationalStatus for all HPSCSI_ComputerSystem instances HP consolidated status for all SCSI HBAs Opaque key Consolidated status for all SCSI HBAs • 0 (Other) • 2 ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 357
Table 16-22 Class: HPSCSI_StorageEnclsoureLocation (HP_Location) Property name Description Name PhysicalPosition ElementLocationTag ElementLocationTagDesc Property implementation Enclosure location For example, Internal Storage System on Port 1 Key Key • External for external enclosures • Internal - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 358
Table 16-24 Class: HPSCSI_HBALocation (HP_Location) Property name ElementName Caption Description Name PhysicalPosition ElementLocationTag ElementLocationTagDesc LocationInformation[0] LocationInfoDesc[0] Property implementation Controller name and location (for example, SCSI Controller Port 1 in - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 359
Table 16-26 Class: HPSCSI_HBAProduct (CIM_Product) Property name ElementName IdentifyingNumber Name Vendor Version Property implementation Controller name and location (for example, SCSI Controller Port 1 in Slot 4) Key: Opaque key Marketing name Vendor string Firmware version 16-3-26 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 360
31 HPSCSI_HBAComputerSystemStorageExtent (Association) Table 16-32 Class: HPSCSI_HBAComputerSystemStorageExtent (CIM_SystemDevice) Property PartComponent Property implementation HPSCSI_HBAComputerSystem HPSCSI_StorageExtent 16-3-32 HPSCSI_HBAComputerSystemSPIPort (Association) Table 16-33 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 361
Table 16-34 Class: HPSCSI_HBAComputerSystemDAPort (CIM_SystemDevice) Property name GroupComponent PartComponent Property implementation HPSCSI_HBAComputerSystem HPSCSI_DAPort. 16-3-34 HPSCSI_HBAComponentCS (Association) Table 16-35 Class: HPSCSI_HBAComponentCS (CIM_ComponentCS) Property name - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 362
16-3-38 HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage (Association) Table 16-39 Class: HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage (CIM_Container) Property name GroupComponent PartComponent Property implementation HPSCSI_HBAPhysicalPackage HPSCSI_DiskPhysicalPackage 16-3-39 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 363
16-3-42 HPSCSI_StorageEnclosureProcessorEnclosureFirmware (Association) Table 16-43 Class: HPSCSI_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation HPSCSI_EnclosureFirmware - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 364
16-3-46 HPSCSI_StorageExtentStorageVolume (Association) Table 16-47 Class: HPSCSI_StorageExtentStorageVolume (CIM_BasedOn) Property name SystemElement SameElement Property implementation HPSCSI_StorageExtent HPSCSI_StorageVolume 16-3-47 HPSCSI_DAPortSCSIProtocolEndpoint (Association) Table 16- - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 365
Table 16-51 Class: HPSCSI_HBAGroupCollectionHBAComputerSystem (CIM_MemberOfCollection) Property name Member Collection Property implementation HPSCSI_ HBAComputerSystem HPSCSI_HBAGroupCollection 16-3-51 HPSCSI_HBASystemPackaging (Association) Table 16-52 Class: HPSCSI_HBASystemPackaging ( - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 366
16-3-55 HPSCSI_StorageEnclosureEnclosureLocation (Association) Table 16-56 Class: HPSCSI_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Element PhysicalLocation Property implementation HPSCSI_StorageEnclosure HPSCSI_StorageEnclosureLocation 16-3-56 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 367
Property implementation HPSCSI_HBAComputerSystem HPSCSI_DASCSIProtcolEndpoint 16-4 Supported indications Table 16-62 HPSCSI_DeviceIndication: SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Information - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 368
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 369
SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at indication Severity (for example, 5 (Major)) Time of indication SCSI physical - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 370
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 371
the computer system generating the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 15BSCSI HBA 371 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 372
CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName Property implementation GUID string generated at indication 6 (Critical) Time of indication The physical drive is offline - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 373
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 374
EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion Property implementation GUID string generated at indication 2 (Informational) Time of indication A physical drive that was - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 375
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 376
EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber SystemProductID SystemModel Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 377
Property name CIM_Indication IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was located - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 378
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 379
AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 2 (Information) Time of indication A physical drive that was located - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 380
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 381
Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation GUID string generated at indication 0 (unknown) Time of indication Controller The SCSI device has - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 382
HWFirmwareVersion HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 383
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 384
AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause Property implementation GUID string generated at indication 6 (Critical) Time of indication SCSI HBA has failed and - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 385
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 386
HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion NetworkAddresses OSType OSVersion SystemFirmwareVersion SystemSerialNumber Property implementation GUID string generated at indication 5 (Major) Time of indication This SCSI Storage enclosure power - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 387
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 388
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 389
IndicationIdentifier PerceivedSeverity IndicationTime CIM_AlertIndication Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions Property implementation GUID string generated at indication 3 (Warning) Time of indication One of the component power - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 390
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 391
EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProbableCauseDescription ProviderVersion Property implementation GUID string generated at indication 2 (Info) Time of indication The storage enclosure temperature is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 392
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 393
SystemSerialNumber SystemProductID Property implementation GUID string generated at indication HPSCSI_StorageEnclosureProcessor class instance 2 (CIMObjectPath) 5 (Device Alert) 24 SCSIHBA Ensure server cover is properly installed. Ensure all empty disk drive bays are filled with - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 394
HWFirmwareVersion HWLogicalLocation HWSerialNumber HP_DeviceIndication DeviceModel Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 395
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 396
Description AlertingMangedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary Property implementation GUID string generated at indication 2 (Info) Time of indication Storage enclosure fan subsystem is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 397
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 398
ProviderName RecommendedActions SystemName SystemCreationClassName HP_AlertIndication Summary EventCategory ProbableCause ProviderVersion NetworkAddresses OSType OSVersion Property implementation GUID string generated at indication 4 (Minor) Time of indication This SCSI Storage enclosure fan is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 399
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 400
the computer system generating the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 15BSCSI HBA 400 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 401
Table 16-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HP_HardwareIndication HWFirmwareVersion HWLogicalLocation HWManufacturer HWSerialNumber - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 402
provider implements the DMTF Software Inventory profile to support inventory of HP installed software on Integrity systems. The following profiles are implemented and files are installed by this provider. Table 17-1 Overview Implemented Profiles Provider Installation Files DMTF Software Inventory - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 403
Table 17-2 Class: CIM_SoftwareIdentity Property name ElementName CIM_ManagedSystemElement OperationalStatus StatusDescriptions Name CIM_SoftwareIdentity InstanceID Classifications ClassificationDescriptions Manufacturer InstallDate Property implementation Contains the corresponding comma separated - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 404
Table 17-2 Class: CIM_SoftwareIdentity Property name VersionString MajorVersion MinorVersion RevisionNumber BuildNumber IdentityInfoType IdentityInfoValue Property implementation Version of the software identity as reported by its underlying instrumentation. If this version can be represented in - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 405
17-4 Supported indications There are no indications produced for the software inventory profile implementation. 16BSystem software 405 - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 406
files are installed by this provider. Table 18-1 Overview Implemented Profiles Provider Installation Files HP Profile Registration Profile (P00100) • HPWmiProfile.dll • HPWmiProfile.mof 18-2 Use cases For use cases, see the HP Profile Registration profile (P00100). 18-3 Class implementations The - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 407
Property Values of CIM_RegisteredProfile for DMTF Profiles RegisteredName Registered Version Base Server CPU Fan Power Supply 1.0.0 1.0.0 1.0.0 1.0.0 Record Log Sensors Profile System Memory Profile 1.0.0 1.0.0 1.0.0 Physical Asset Profile 1.0.0 Power State Management 1.0.0 Profile Software - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 408
Values of HP_RegisteredProfile for HP WBEM TC Profiles RegisteredName Registered Version InstanceID HP Base Server HP CPU HP Fan 1.0.0 1.0.0 1.0.0 HP:Base Server HP:CPU HP:Fan Caption/Description/ ElementName HP Base Server Profile HP CPU Profile HP Fan Profile 17BProfile registration - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 409
HP:Power Supply HP Power Supply Profile HP:Record Log HP Record Log Profile HP:Sensors HP Sensors Profile HP:Memory HP Memory Profile HP:Base Server Physical Asset HP Base Server Physical Asset Profile HP:CPU Physical Asset HP CPU Physical Asset Profile HP:Memory Physical Asset HP Memory - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 410
HP_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered server and network profiles, the storage computer system for storage profiles) 18-4 Supported indications There are no indications specific - HP Integrity rx8620 | HP Insight Management WBEM Providers on Integrity Servers - Page 411
19 For more information • http://www.dmtf.org • http://www.snia.org • http://www.hp.com 18BFor more information 411
HP Insight Management WBEM Providers for
Windows on Integrity Servers
Data Sheet
Part number
5992-4515
First Edition September 2008