HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide Part Number 519430-004 December 2010 (Fou rth Edition) - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 2
license. Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation. Intended audience This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 3
issues...20 Using a diagnostic monitor for troubleshooting 20 Target connection problems ...20 Target login problems ...21 Boot problems...21 LUN access problems...21 OS problems ...21 Technical support...23 Before you contact HP...23 HP contact information ...23 Acronyms and abbreviations 24 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 4
by the adapter's iSCSI HBA driver. For more inf ormation on this feature, see the HP ProLiant Accelerated iSCSI for Windows User Guide. Limitations • A system crash might result if you bring down a network adapter that is iSCSI-boot enabled. The Windows Server 2003 SP2 operating system prevents - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 5
HP iSCSI boot for Windows SoftPaq downloadable from the HP website (http://www.hp.com). • HP Gigabit downloaded or requested from M icrosoft: • Microsoft iSCSI Software Initiator Version 2.06 (http://www.microsoft.com/downloads) or later • Microsoft Storport Driver update: KB943295 (http://support - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 6
.hp.com/#Support). 2. Click Support & Drivers. 3. Select Download drivers and software (and firmware). 4. Type the adapter name in the For product box, and then click Go. 5. Select an operating system. 6. Click HP NC-Series Broadcom iSCSI Boot Package for Windows. 7. Click download and save the HP - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 7
.20 format Target Port, generally 3260 TargetPort=3260 Secondary TargetIP TargetIP2=10.10.20.20 Secondary Port TargetPort2=3260 Name used for the iSCSI initiator on the booting system. InitiatorName=iqn.client01 IP network mask used by the InitiatorNetmask=255.255.255.0 iSCSI initiator. This - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 8
False for servers that support the network adapter in the RBSU controller order menu. UseBIOSInterface Set to True for Windows 2003 installation. Set to Fastpath feature that is pure HBA. • Set to False for Windows to boot using NDIS native method. HeaderDigest Enable HeaderDigest (CheckSum). - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 9
# Hard coded Target IP .. No DNS support # TargetName=iqn.2003-05.com.hp1510i:disk01 TargetIP=10.10.10.13 TargetIP2=10.10.20.13 ## # local name the iSCSI client servers that support the network adapter in the ## RBSU controller order menu. ForceBoot=True # ## Set to True for Windows 2003 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 10
iLO The IP address of the HP Integrated Lights Out management port from which to boot server for the user name of the HP Integrated Lights Out management port from HP network adapters For embedded adapters and mezzanine adapters, the firmware update utility installs the option ROM on all supported - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 11
PXE, iSCSI boot, disable d. Selected iSCSI boot for the desired adapter. HP recommends that PXE is disabled on unused ports to conserve option ROM space d isk devices in the Boot Controller Order list. Set the iSCSI boot network adapter as the boot disk as follows. a. During the boot press F9 to - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 12
network adapter does not appear in the Boot Controller Order list, you r System ROM d oes not support this feature. If the System ROM is up to date, it is necessary to override the Boot Controller Order list b y setting EV parameter "ForceBoot=True". Windows Server 2008 installation Add HP drivers - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 13
to False (see "Initialize iSCSI boot configuration parameters (on page 6)") for more information. 3. Boot the updated Windows Server 2008 DVD that you created in the "Add HP drivers to the Microsoft Windows 2008 DVD WIM image (on page 12)" section. 4. Navigate to the setup screen and select the Load - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 14
includes the Microsoft Storport hotfix KB943295 (http://support.microsoft.com/kb/943295). See the Microsoft KB article KB814847 (http://support.microsoft.com/kb /814847) for details about how to create a M icrosoft slipstream CD. 4. Insert the slipstream M icrosoft Windows 2003 SP2 CD and press F6 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 15
5. Select drivers from the disk 1 and disk 2 diskettes when prompted. DO NOT insert d isk 1 into drive A until prompted. After disk 1 is inserted, the following window appears. 6. Select Specify Additional Device. The following window appears. Installation and configuration 15 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 16
f ollowing steps to install the first three files. a. Select Install 1st: MS Windows wdfldr and then press Enter. b. Select Install 2nd: HP Windows wdf01000 and then press Enter. c. Select Install 3rd: HP NC37x/NC380 Virtual Bus Driver and then press Enter. 9. Insert disk 2 and press Enter when the - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 17
10. Press Enter to install the 4th file: HP iSCSI HBA Driver. 11. A Windows setup screen shows the iSCSI Target. Installation and configuration 17 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 18
setup may appear prompting for d isk 1 and disk 2 again. 13. If the following window appears, insert disk 1 and press Enter. 14. If the following window appears, insert disk 2 and press Enter. Windows Server 2003 continues installing on the iSCSI target. Post installation procedures After the CD - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 19
crash dump. 3. Complete the installation and reboot when prompted. Set up crash dump support The HP iSCSI crash dump driver provides a mechanism for an HP iSCSI Booted system to capture data for analysis when a Windows 2003 OS System Stop Event is encountered (BSOD). System data is generally saved - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 20
Multipath I/O (MPIO) is not supported for failover for boot filesystem because MPIO drivers cannot be added during an install problem is not discernable from the immediately available information, you ma y need to use a network monitor that is capable of parsing the iSCSI protocol to troubleshoot - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 21
so on. • Verif y the Option ROM configuration setting "Boot to iSCSI" is set to Enabled. LUN access problems Symptoms: The initiator is able to connect to and log in to the ta rget, but the system doesn't to allow access to the specified LUN by the initiator OS problems Symptoms: Troubleshooting 21 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 22
the operating system. Possible causes: • There are multiple HP Multifunction Gigabit Server adapters (NC37xx, NC38xx) adapters enabled in the system • The drivers are not being loaded in the right order during not conf igured to allow access to the specified LUN by the initiator Troubleshooting 22 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 23
y/us/en /ww contac t.html). For HP technical support: • In the United States, for contact options see the Contact HP United States webpage (http://welcome.hp.com/country/us/en/contact_us.html). To contact HP by phone: o Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hou rs a day - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 24
Acronyms and abbreviations BSOD blue screen of death CHAP Challenge Handshake Authentication Protocol DHCP Dynamic Host Conf iguration Protocol HBA host bus adapter iLO Integrated Lights-Out iLO 2 Integrated Lights-Out 2 IPL initial program load iSCSI Internet Small Computer System Interface LAA - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 25
RBSU ROM-Based Setup Utility RILOE Remote Insight Lights-Out Edition SAN storage area network UNDI Universal Network Driver Interface VLAN virtual local-area network WIM Windows Imaging file format Acronyms and abbreviations 25 - HP Intel Pro/100 | HP Broadcom iSCSI Boot for NC37xx/NC380x Adapters User Guide - Page 26
12, 19, 20, 21 supported targets 4, 6, 12, 19, 20, 21 system requirements 4 T target connection problems 20 target installs 13 target login problems 21 teaming limitations 4 technical support 23 troubleshooting 20 V VLAN inf ormation 6, 20 W WIM image 12 Windows Server 2003 13 Windows Server 2008 12