HP LC2000r HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv
HP LC2000r - NetServer - 128 MB RAM Manual
View all HP LC2000r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP LC2000r manual content summary:
- HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 1
LP2000r with NetRAID-4M (HP Rack Storage/12) Windows® 2000 Advanced Server Cluster Configuration Guide 2 May 2001 (see Versions at the end of this document) Introduction This document defines the configurations that Hewlett-Packard supports for the HP NetServer LP2000r, HP Rack Storage/12 and - HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 2
Storage Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows® 2000 Advanced Server SP1 HP NetServer LP2000r 1 GHz 2 4.06 - HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 3
options: Cabinet Disk drives: No. of cabinets Model Status SCSI ID Disk SCSI Ids Cables LANs LAN connection NIC: Model Driver No. of NICs 6, 7 0, 1, 2, 3 All fault tolerant RAID types supported by controller: 1, 5, 10 (Stripe set of mirror sets RAID 0/1), 50 (Stripe set of RAID-5 sets), Volume set - HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 4
slot P5 for the shared storage NetRAID-4M. 3. Cables between the servers and shared storage cabinets can be any HP LVD SCSI (offset) cable up to 10 meters. See "Cables"for Rack Storage/12 in the guide for a list of cables that can be used. HP NetServer LP2000r Cluster using HP Rack Storage/12 4 - HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 5
Power Cabling to Separate Power Circuits 5 - HP LC2000r | HP Netserver LP 2000r NetRAID-4M Config Guide for Windows 2000 Adv - Page 6
Versions 2 May 2001 Initial release © Copyright 2001, Hewlett-Packard Company 6
1
HP Netserver LP2000r
with
NetRAID-4M (HP Rack Storage/12)
Windows
2000 Advanced Server
Cluster Configuration Guide
2 May 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for the HP NetServer LP2000r,
HP Rack Storage/12 and Microsoft
Cluster Server.
These configurations minimize single points of
failure (SPOF) and provide extended availability.
The specific configuration certified and supported by
both Hewlett-Packard and Microsoft
is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LP2000r
Each node must be the same SPU, but may have different clocks speeds,
main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-4M controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable or equivalent. See
Intra-cluster LAN
below.