- HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 1
Edition Cluster Configuration Guide Introduction This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of two HP Netserver LP 1000r servers and one or two HP Rack Storage/12 disk drive enclosure(s), with Microsoft® Cluster Server software. These - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 2
lp1000rnt2m Server Configuration Parameter I/O slot Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification PCI slot 1 IDE CD-ROM, FDD, embedded - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 3
SCSI IDs Cables SCSI Power distribution Layout Specification Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. One or two Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 4
Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One Embedded NIC - LAN B Hptxnt.sys, version 4.02.35, or later (driver obtained from Navigator CD-ROM L.20.00, or later) lp1000rnt2m 2/23/02 4 - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 5
both nodes. All cables are the same type. 2. Cables between the servers and RS/12s can be any HP LVD SCSI cable up to 10 meters. See "Cables" in the Shared client network connections. LAN A -heartbeat LAN B -client HP Netserver LP 1000r Cluster using HP Rack Storage/12 Cabling Diagram 2/23/02 5 - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 6
lp1000rnt2m Power Cabling to Separate Power Circuits 2/23/02 6 - HP LH6000r | hp netserver lp 1000r netraid-2m config guide — for Mi - Page 7
Versions 23 February 2002 Initial release lp1000rnt2m © Copyright 2002, Hewlett-Packard Company 2/23/02 7
2/23/02
1
HP Netserver LP 1000r with
NetRAID-2M (HP Rack Storage/12)
Windows NT
°
4.0 Enterprise Edition
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP Netserver LP 1000r servers and one or two HP Rack Storage/12 disk drive enclosure(s), with
Microsoft
Cluster Server software.
These configurations provide high server cluster availability and
minimize single points of failure (SPOFs).
A configuration certified and supported by both Hewlett-Packard
and Microsoft
is included, but any cluster configuration that conforms to the guidelines of this document
will be supported by Hewlett-Packard.
Deviations from the supported configurations can result in an
inoperative cluster, an operating cluster with degraded performance, or hidden SPOFs.
Therefore, deviations
are not supported.
For revision/update information on this document, refer to
Versions
on page 7.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below and their associated configuration data is detailed in separate tables
and illustrations that follow.
•
Server configuration
•
Shared storage configuration
•
Microsoft
and HP certified server configuration
•
Intra-cluster (heartbeat) LAN configuration
•
Client LAN configuration
•
SCSI cabling and power distribution configuration
Server Configuration
Parameter
Specification
Server
Type
HP Netserver LP 1000r
Number of nodes
Two
Each node must be the same server type, but may have different clock speeds, and
main memory and cache sizes.
Clock speed
1.26 GHz
This certification covers any Tualatin (1.13 GHz or greater) CPU speed within
500 MHz of the certified rate.
Number of CPUs
Two
BIOS
Version 4.06.03 RO or later
CPU cache
Any size
RAM
128 MB, minimum.
Must be HP.
Number of power
supplies
One