HP MDS600 HP StorageWorks 600 Modular Disk System User Guide
HP MDS600 Manual
View all HP MDS600 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP MDS600 manual content summary:
- HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 1
StorageWorks 600 Modular Disk System User Guide Abstract This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical support. This guide is for an experienced service technician. HP assumes you are qualified - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 2
forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 3
the hard drives ...19 Installing the I/O module ...21 Cabling the MDS600 ...22 SAS cabling guidelines ...22 Cabling guidelines for HP rack and tower servers 22 Supported cables ...22 Power cords ...23 Configuration and utilities ...24 Configuration tools ...24 Array Configuration Utility ...24 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 4
Power cord statement for Japan ...39 Electrostatic discharge ...40 Preventing electrostatic discharge ...40 Grounding methods to prevent electrostatic discharge 40 Specifications ...41 Environmental specifications ...41 Storage array specifications ...41 Technical support...42 Before you contact HP - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 5
Component identification Front panel components Item 1 2 3 4 Description Drawer 1 Drawer 1 diagnostic cable access (For use by authorized HP personnel only) Drawer 2 Drawer 2 diagnostic cable access (For use by authorized HP personnel only) Component identification 5 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 6
, or migration. Flashing amber (1 Hz) = A predictive failure alert has been received for this drive. Replace the drive as soon as possible. Amber = Drive failure, link failure, or mismatched configuration. Off = The drive is offline, a spare, or not configured as part of an array. Component - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 7
drive is not selected. Blue = UID LED is enabled from the UID button Blue flashing = Item 1 is in locate mode Off = UID LED is disabled Green = System health is good Off = System is off Amber = Enclosure requires service check: I/O, fan and power supply LEDs, and AC power cables to power supplies - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 8
Fan module 2 (Drawer 1) Power supply 4 SAS port 1 connector SAS port 2 connector Secondary I/O module (Drawer 2) Fan module 2 (Drawer 2) Power supply 2 Rear panel LEDs and buttons Item 1 Description Status Power On/Standby button and system power LED Green = On Amber = Standby (auxiliary power - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 9
requires service check: I/O, fan and power supply LEDs, and AC power cables to power supplies. Off = Enclosure is functioning normally. UID button/LED (Drawer 2) Blue = UID LED is enabled from the UID button. Blue flashing = System is in hard drive locate mode or an enclosure firmware update is - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 10
Device bay ID numbers SAS and SATA hard drive LEDs Item 1 2 Description Fault/UID LED (amber/blue) Online LED (green) Component identification 10 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 11
for this drive and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. Component identification - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 12
ensure all I/O modules have been updated to the latest compatible MDS600 firmware. If the MDS600 is directly cabled to an HP 3Gb SAS Blade Switch, go to the HP website (http://www.hp.com/support) to download the MDS600 firmware image, and then use the active HP Virtual SAS Manager maintenance tab to - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 13
the server blade documentation. 2. Connect the SAS cables and power cords to the MDS600. 3. Press and hold the Power On/Standby button. Wait and observe the system power LED and system fans. When the MDS600 powers up, the system power LED illuminates solid green and the system fans spin to a high - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 14
and airflow requirements To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to back of the rack to the back of another rack or row of racks. The HP MDS600 draws in cool air through the front door, and then expels warm air through the - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 15
covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option. WARNING: To reduce the - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 16
. Ensure that the raised floor space, cooling equipment, power supply equipment and generators, and other support equipment meet the demands of all the servers and other mission-critical equipment. Installing the enclosure WARNING: The storage array with no drives installed weighs 72.58 kg (160 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 17
install a 1U tray beneath the MDS600 to ensure proper support. • Be sure sufficient clearance exists for cabling, installation and removal of the enclosure, actuation of the rack doors, and full articulation of the drive drawers. IMPORTANT: Some racks other than the HP Rack 10000 Series rack do not - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 18
rails while the other two people support the weight of the enclosure. 5. Install the HP MDS600 Disk System. 6. Tighten the thumbscrews to secure the HP MDS600 Disk System to the rack. The installation is complete. Hard drive overview The MDS600 supports up to 35 SAS or SATA hard drives per storage - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 19
the drawer. • A RAID 1 mirror requires an even number of hard drives. • Drives that will be configured within an array should be the same capacity to provide the greatest storage space efficiency. NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume. Installing the hard - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 20
and thermal damage, do not operate the MDS600 for an extended period of time with the drawer open. CAUTION: To prevent improper cooling and thermal damage, do not operate the MDS600 unless all bays are populated with either a component or a blank. 4. Remove the hard drive blank. 5. Prepare the hard - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 21
, close the hard drive drawer. Installing the I/O module 1. Be sure the hard drive drawer is closed all the way. 2. Release the I/O blank handle. 3. Push the I/O blank handle down until it ejects the I/O blank. 4. Remove the I/O blank. 5. Install the I/O module into the enclosure. Setup 21 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 22
hard drive drawer is not a valid configuration. See the QuickSpecs on the HP website (http://www.hp.com/go/mds600) for additional special cabling guidelines. Supported cables No SAS cables ship with the MDS600. The only supported cable length that can be used is the 2.00 m (6.56 ft) mini-SAS cable - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 23
For a complete list of supported cables, see the QuickSpecs on the HP website (http://www.hp.com/go/mds600). Power cords The power cord should be approved for use in your country. The power cord must be rated for the product and for the voltage and current marked on the electrical ratings label of - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 24
and utilities Configuration tools Array Configuration Utility NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume. ACU is a browser-based utility with the following features: • Runs as a local application or remote service • Supports online array capacity expansion - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 25
Flash To update the firmware on the server, controller, hard drives, or enclosure use Smart Components. These components are available on the Firmware Maintenance CD. A more recent version of a particular component might be available on the support page of the HP website (http://www.hp.com/support - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 26
user interface • From within HP Insight Diagnostics For more information, see the Management CD in the HP Insight Foundation suite for ProLiant. Array Diagnostic Utility The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage controllers and disk drives - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 27
Care Pack HP Care Pack Services offer upgraded service levels to extend and expand bundled services with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. For more information, see the HP website (http://www.hp.com/services/carepack). Configuration and - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 28
from enclosure power supplies and reinsert them. 5. Restart the system. 6. Check the MDS600 for the following normal power-up sequence to be sure that the system meets the minimal hardware requirements and is powered up during normal operations: a. The rear panel power LED turns from standby (amber - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 29
troubleshooting required. May be seen with status codes 2, 3, and 4. 2 = Temperature sensor Check for thermal issues within the MDS600 drawer, for example, extremely hot warning drives, air blockages, or high ambient lab temperature. 3 = System Fan Warning Replace any fan with an amber LED - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 30
GSI LED is still amber, replace the other I/O module. AC power cycle the MDS600. If replacing the I/O modules does not resolve the issue, replace the drawer. * I/O module Firmware and Power Block Firmware are delivered through the MDS600_FW download process. Recognizing hard drive failure In an HP - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 31
replacing hard drives You can replace hard drives without powering down the system. However, before replacing a degraded drive: • Open HP SIM and inspect the Error Counter window for each physical drive in the same array to confirm that no other drives have any errors. (For details, refer to the HP - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 32
drive LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk errors. Remove and replace the failed replacement drive. When automatic data recovery has finished, the Online LED of the replacement drive stops flashing and begins to glow steadily. Troubleshooting - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 33
rebuild If a non-correctable read error occurs on another physical drive in the array during the rebuild process, the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates. If this situation occurs, reboot the server. The system may temporarily become operational - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 34
with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. This device complies with Part 15 of - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 35
in accordance with the instructions, may cause harmful interference turning the equipment off and on, the user is encouraged to try to correct the the FCC logo, United States only This device complies with Part 15 of the FCC O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 • 1-800-HP-INVENT - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 36
the part, series, or model number found on the product. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 37
telecommunications products, such as Bluetooth® within power class below 10mW. For EU non-harmonized 140, 71034 Boeblingen, GERMANY. Disposal of waste equipment by users in private households in the European Union This symbol on service or the shop where you purchased the product. Regulatory - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 38
Japanese notice BSMI notice Korean notice Class A equipment Class B equipment Regulatory compliance notices 38 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 39
Chinese notice Class A equipment Vietnam compliance marking notice This marking is for applicable products only. Ukraine notice Power cord statement for Japan Regulatory compliance notices 39 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 40
static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: • service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 41
corresponds to a pressure minimum of 70 KPa. ‡ Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Storage array specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 22.10 cm (8.70 in) 89.12 cm (35.08 in) 44.70 cm (17.60 in) 145 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 42
a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts: • Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. Technical support 42 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 43
HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 44
ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No" bzw. „Nein" gekennzeichnet. Technical support - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 45
defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio. Technical support 45 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 46
onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. Technical support 46 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 47
para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP (http://www.hp.com/go/selfrepair). Technical support - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 48
Technical support 48 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 49
Technical support 49 - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 50
Utility CPQONLIN NetWare Online Array Configuration Utility GSI global service indicator iLO 2 Integrated Lights-Out 2 IML Integrated Management Log ORCA Option ROM Configuration for Arrays PSP ProLiant Support Pack SIM Systems Insight Manager UID unit identification Acronyms and abbreviations - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 51
15 guidelines, cabling 22 H hard drive LEDs 10, 11 hard drive, failure of 30 hard drives, installing 18, 19 HP Insight Remote Support software 26 HP ProLiant Essentials Foundation Pack 25 HP Systems Insight Manager overview 25 HP technical support 42 I I/O module 21 identification number - HP MDS600 | HP StorageWorks 600 Modular Disk System User Guide - Page 52
18 SAS hard drive LEDs 10 SATA hard drive 18 SATA hard drive LEDs 10 series number 34 site planning considerations 16 Smart Components for Remote ROM Flash 25 software 24 space requirements 14 specifications 41 static electricity 40 storage array specifications 41 support 26, 42 system configuration
HP StorageWorks 600 Modular Disk System
User Guide
Abstract
This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical
support. This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 495105-007
August 2011
Edition: 7