HP ML350 HP Insight Management WBEM Providers for HP integrated VMware ESXi Da
HP ML350 - ProLiant - G6 Manual
View all HP ML350 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP ML350 manual content summary:
- HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 1
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet Part number 574748-002 Second Edition December 2009 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP will not be liable for technical or editorial errors - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 3
30 2-3-23 SMX_EthernetElementFirmwareIdentity 31 2-3-24 SMX_EthernetCollection...31 2-3-25 SMX_EthernetMemberOfCollection 32 2-3-26 SMX_EthernetGroupHostedCollection 32 2-4 Supported indications ...32 3 PCI Device Provider ...36 3-1 Overview...36 3-2 Use Cases...36 3-3 Class Implementations - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 4
4 Smart Array ...44 4-1 Overview...44 4-2 Use cases ...44 4-3 Class implementations ...44 4-3-1 SMX_SAArraySystem ...44 4-3-2 SMX_SAArrayController ...46 4-3-3 SMX_SAStorageVolume ...48 4-3-4 SMX_SADiskDrive...49 4-3-5 SMX_SAStorageExtent ...50 4-3-6 SMX_SADiskDriveFirmware 51 4-3-7 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 5
84 SMX_SAStorageEnclosureEnclosureLocation (Association 86 4-4 Supported indications ...86 4-4-1 HP_DeviceIndication: Physical 18 HP_DeviceIndication: Controller Cache status-Permanently Disabled 128 4-4-19 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant 131 Contents 5 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 6
27 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant 133 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant 5-2-5 HPVC_SAStorageVolume...154 6 Base server ...156 6-1 Overview...156 6-2 168 6-4 Supported indications ...168 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 7
17 SMX_ProcessorLocation ...189 7-3-18 SMX_ProcessorElementLocation 191 7-4 Supported indications ...191 7-4-1 HP_DeviceIndication: Processor Failed 211 8-4-10 HP_DeviceIndication: Fan Redundancy Failed 211 9 System Power Supply ...213 9-1 Overview...213 9-2 Namespaces ...213 9-3 Class - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 8
...223 9-4 Supported indications ...223 9-4-1 Provider Indication Common Properties 223 9-4-2 HP_DeviceIdentification: Power Supply Removed 224 9-4-3 HP_DeviceIndication: Power Supply Inserted 225 9-4-4 HP_DeviceIndication: Power Supply Failed 225 9-4-5 HP_DeviceIndication: Power Supply Degraded - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 9
SMX_HostedMemoryRedundancySet 271 SMX_SystemMemoryModuleSlot 271 SMX_SystemMemoryBoardSlot 272 Supported indications ...272 13 Blade System 282 13-3-9 SMX_BladeCSLocation ...282 13-3-10 SMX_BladeCSElementLocation 283 13-4 Supported indications ...283 14 FC HBA...284 14-1 Overview ...284 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 10
SMX_MPFirmware ...309 15-3-3 SMX_MPCollection ...310 15-3-4 SMX_MPHostedCollection 311 15-3-5 SMX_MPComponentCS ...312 15-3-6 SMX_MPMemberOfCollection 312 15-3-7 CIM_MPElementFirmwareIdentity 312 15-3-8 SMX_MPInstalledFirmwareIdentity 313 15-4 Supported indications ...313 Contents 10 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 11
Insight Management WBEM Providers supply system management data through HP integrated VMware ESXi framework for HP ProLiant server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires HP integrated VMware ESXi. Overview 11 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 12
Location Profile 1.0 • HP Ethernet Teaming Profile - P00117 v1.0.1 (partial only, VMware only -no teams) • DMTF: IP Protocol Profile (w/ IPv6 implementation) • - DSP1036 version 1.0.0 Date 09/04/2008 2-2 Namespaces This provider returns instances in the root/hpq namespace. 2-3 Class implementations - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 13
• SMX_RemoteServiceAccessPoint • SMX_RemoteAccessAvailableToIPEndpoint • SMX_RemoteServiceHostedAccessPoint • SMX_EthernetStatistics • SMX_EthernetPortToStatisticalData • SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 14
of a the Ethernet Port, in the format FFFFFFFFFFFF, where each F is a text representation of a hexidecimal digit 0x0 - 0xF. (unique within a specific ethernet controller) Not implemented for single port controllers Current bandwith in bits per second. If port has link (value is 0 otherwise - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 15
Table 2-2 Class: SMX_EthernetPort PortType Capabilities[] CapabilityDescriptions[] EnabledCapabilities[] NetworkAddresses[] OtherEnabledCapabilities VirtualPortNumber 0 (Unknown) 1 ( Other) 50 (10BaseT) 51 (10-100BaseT) 52 (100BaseT) 53 (1000BaseT) 54 (2500BaseT) 55 (10GbaseT) 56 (10Gbase-CX4) 100 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 16
2-3-2 SMX_EthernetDevice SMX_EthernetDevice implements the class HP_EthernetDevice and associates the enclosures computer system instance to the blades computer system instance. Table 2-3 Class: SMX_EthernetDevice Property name Property implementation HP_EthernetDevice GroupComponent ref: - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 17
: LAN Endpoint() for : 82546GB Gigabit Ethernet Controller port HPQ:SMX_EthernetLANEndpoint: 6 (Ethernet CSMA/CD) CIM_LANEndpoint Text representing the principal unicast address used in communication with the LANEndpoint. Twelve hexadecimal digits. For - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 18
2-3-5 SMX_EthernetPortToLANEndpoint SMX_EthernetPortToLANEndpoint implements the class HP_EthernetPortToLANEndpoint and associates the Ethernet Port instance to its Ethernet LAN Endpoint instance. Table 2-6 Class: SMX_EthernetLANHostedAccessPoint Property name Property implementation - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 19
Table 2-7 Class: SMX_EthernetPortController Property name SystemCreationClassName SystemName IdentifyingDescriptions ControllerType ControllerVersion Property implementation SMX_ComputerSystem SMX_ComputerSystem.Name None CIM_Controller CIM_PortController 2 (Ethernet) Hardware revision number of - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 20
BCM5753M Gigabit Ethernet PCI Express (rev 21) Ethernet Controller Package Text representng vendor info from PCI config space. (HP, Intel®, Broadcom and so on) HPQ:SMX_EthernetPortContollerPhysicalPackage Hardware version of the Package or N/A CIM_PhysicalPackage If PackageType is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 21
representing the slot location. Examples: If an embedded controller on a motherboard or chassis Embedded Controller; On non-cellular servers: On cellular servers: Cabinet: Bay: Chassis: Slot: Ethernet port 21 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 22
Table 2-11 Class: SMX_EthernetControllerLocation Property name LocationInfoDesc Property implementation Array of enums describing values at comparable index in LocationInformation array. LocationInfoDesc[0] per LocationInfornation[0]. Values for embedded devices: • 17 (Embedded) non-blade, non- - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 23
Table 2-13 Class: SMX_IPProtocolEndpoint Property name ElementName Caption Description HealthState StatusDescriptions Property implementation CIM_ManagedElement IP Protocol Endpoint info for OS Exposed Ethernet Port informatiom. For example: IP Protocol Endpoint() for : 82546GB - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 24
Table 2-13 Class: SMX_IPProtocolEndpoint Property name AddressOrigin IPv4Address IPv6Address IPv6AddressType IPv6SubnetPrefixLength PrefixLength Name NameFormat PrefixLength ProtocolIFType SubnetMask Property implementation How the Address was assigned to this IP Protocol Endpoint. • 0 (Unknown) • - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 25
2-3-13 SMX_IPBindsToEthernetLANEndpoint SMX_IPProtocolBindsToEthernetLANEndpoint implements the class HP_IPBindsToEthernetLANEndpoint and associates an instance of an IP ProtocolEndpoint with its representative Ethernet LAN Endpoint instance. NOTE: Currently not implemented on VMware ESXi platform. - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 26
Table 2-16 Class: SMX_RemoteServiceAccessPoint Property name ElementName CreationClassName Name SystemCreationClassName SystemName AccessContext AccessInfo InfoFormat Property implementation CIM_ManagedElement A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 27
ref: SMX_IPProtocolEndpoint 2-3-17 SMX_EthernetRemoteServiceHostedAccessPoint SMX_RemoteServiceHostedAccessPoint implements the class HP_RemoteServiceHostedAccessPoint and associates Remote Service Access Point to the Computer System in a managed system. NOTE: Currently not - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 28
Table 2-19 Class: SMX_EthernetStatistics Property name Caption Description ElementName InstanceId SampleInterval StatisticTime BytesReceived BytesTransmitted PacketsReceived AlignmentErrors DeferredTransmissions ExcessiveCollisions FCSErrors InternalMACReceiveErrors InternalMACTransmitErrors - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 29
the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. NOTE Name ClassificationDescriptions Classifications InstanceID Manufacturer VersionString Ethernet Port Controller Driver Product Name Device Driver, where product name is the product name of - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 30
NOTE: Currently implemented only on VMware ESXi platform. Table 2-22 Class: SMX_EthernetPortControllerFirmwareIdentity Property name Property implementation CIM_ManagedElement Caption Description ElementName Name ClassificationDescriptions Classifications InstanceID IdentityInfoType - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 31
Table 2-23 Class: SMX_EthernetElementSoftwareIdentity Property name ElementSoftwareStatus Property implementation ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) 2-3-23 SMX_EthernetElementFirmwareIdentity SMX_EthernetElementFirmwareIdentity implements the class - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 32
name Antecedent Dependent Property implementation CIM_ Dependency ref:SMX_ComputerSystem ref:SMX_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 2-4 Supported indications The following table describes the properties that are common to all of the SMX - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 33
SystemProductID SystemModel SystemGUID Property implementation CIM_Indication GUID string generated at the time of generating the indication Platform GUID of the computer system generating the indication The following indications are implemented for ProLiant server platforms where available. Table - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 34
has transitioned from OK to Error. WBEM Path of the SMX_EthernetPort instance 2 (CIMObjectPath) 2 (Communications Alert) 2 HP Ethernet View the Ethernet Port status in HP Systems Insight Manager (SIM). View the System Event Log for additional information. HP_AlertIndication The Network interface has - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 35
Table 2-30 HP_AlertIndication: Network Interface Connectivity Restored Property name EventCategory EventSubCategory ProbableCause ProbableCauseDescription Property implementation 9 (Network Device) 11 (Ethernet port) 12 (Ethernet team) 13 (Ethernet LAN Endpoint) 7 (Other) Network Interface - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 36
3 PCI Device Provider 3-1 Overview This provider implements the profiles listed to support PCI devices installed in HP servers. The following table details the profiles implemented and files installed by this provider. Table 3-1 Overview Implemented Profiles • DMTF: PCI Device Profile (DSP1075) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 37
(PCI-X Capable) • 6 (PCI Power Management Supported) • 7 (Message Signaled Interrupts Supported) • 8 (Parity Error Recovery Capable) • 9 (AGP Supported) • 10 (Vital Product Data Supported) • 11 (Provides Slot Identification) • 12 (Hot Swap Supported) • 13 (Supports PCI Express) An array of free-form - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 38
• 1 (Mass Storage) • 2 (Network) • 3 (Display) • 4 (Multimedia) • 5 (Memory) • 8 (Base Peripheral) • 9 (Input) • 11 (Processor) • 12 (Serial Bus) CIM_PCIDevice The is used to represent physical PCI adapter card installed on HP Servers. There is an instance of this class for each PCI adapter card - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 39
or not). Table 3-4 Class: HP_PCISlot Property name Caption Name for all other servers Name for HP Integrity cellular-servers CreationClassName Tag for HP Integrity Cellular Servers Property implementation CIM_ManagedElement Same as name CIM_ManagedSystemElement PCI Slot where n is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 40
HP Blade Servers Tag for all other servers as Name Same as Name True -If slot is powered on False-If slot is not powered CIM_PhysicalConnector 7 (Slot) PCI-If 33 MHz PCI PCI slot number True-If slot supports PCI hot plug operations False-If slot does not support PCI hot plug operations HPQ:PCISlot - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 41
3-3-4 SMX_PCICardInSlot SMX_PCICardInSlot is used to represent an association between SMX_PCICard and SMX_PCISlot that contains this PCI card. Table 3-5 Class: SMX_PCICardInSlot Property name Antecedent Dependent Property implementation References SMX_PCISlot References SMX_PCICard 3-3-5 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 42
to model PCI slot locations on HP Servers. The Windows specific implementation class is SMX_PCISlotLocation. Table > • Blade Servers Mezzanine: in Blade: • All other HP Servers PCI Slot LocationInfoDesc for HP Integrity Cellular Servers Array of enumerated - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 43
index in LocationInformation array 0 & 1. LocationInfoDesc[0] per LocationInfornation[0]. Blade servers 1 (Mezzanine Slot) 14 (Blade) Array of enumerated values describing SMX_PCISlot References SMX_PCISlotLocation 3-4 Supported indications There are no indications specific to the PCI device - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 44
implements a read-only version of the profiles referenced. Configuration functionality is not supported by this provider. This is in accordance with the SNIA profiles, because HP does not advertise and ConfigurationService type classes. 4-3 Class implementations The following sections define - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 45
the Array System and attached devices. This is calculated per the algorithm desciribed in the HP Smart Array Profile. 0 (Unknown) 2 (OK) 3 (Degraded) 6 (Error) More Non-Failure Problem Physical Drive Non-Failure Problem Logical Drive Non-Failure Problem Storage Enclosure Non-Failure Problem Array is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 46
Block Server) Other Vendor Specific Name Controller Serial Number Note: EMBEDDED- is reported if there is no Serial Number for device is local i.e embedded on motherboard. PCISLOT- is reported if there is no Serial Number for device is local i.e.PCI occupies slot. See HP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 47
HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 48
4-3-3 SMX_SAStorageVolume SMX_SAStorageVolume implements the HPSA_StorageVolume class and represents the Logical Volumes configured on the Smart Array. Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name ElementName Name EnabledDefault EnabledState RequestedState - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 49
Number Drive status, DMTF defined value is populated in indes (0) and extended status is populated in index (1) per HP Smart Array Profile CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) CIM_LogicalDevice SMX_SADiskDrive Opaque value Smart Array 49 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 50
.Name Number of service hours logged for the drive CIM_MediaAccessDevice CIM_DiskDrive HPSA_DiskDrive See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 51
11 (Rebuild-Disk drive is currently rebuilding data) Total number of blocks on disk drive Set to True Total service hours reported disk drive HPSA_StorageExtent 4-3-6 SMX_SADiskDriveFirmware SMX_SADiskDriveFirmware implements the HPSA DiskDriveFirmware class and represents the firmware installed on - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 52
Table 4-7 Class: SMX_SADiskDriveFirmware (CIM_SoftwareIdentity) Property name ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType IdentityInfoValue VersionString Property implementation Disk Drive Firmware 10 (Firmware) Opaque key Disk drive vendor string [0] - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 53
Table 4-8 Class: SMX _SAPhysicalPackage (CIM_PhysicalPackage) Property name Version RemovalConditions Property implementation N/A-Not Available for this implementation CIM_PhysicalPackage 2 (Not Applicable) HPSA_PhysicalPackage 4-3-8 SMX_SAArrayControllerPhysicalPackage - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 54
4-3-9 SMX_SADiskPhysicalPackage SMX_SADiskPhysicalPackage HPSA_DiskPhysicalPackage class and represents the physical aspects of the disk drive. There is one instance per disk drive. Table 4-10 Class: SMX_SADiskPhysicalPackage (CIM_PhysicalPackage) Property name ElementName Name CreationClassName - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 55
Box: , where is the port and is the box number CIM_PhysicalElement SMX_SAStorageEnclosure Enclosure vendor string HP N/A, if not available Enclosure model string ProLiant 6L6I N/A, if not available N/A-Not Available in this implementation Enclosure Serial Number N/A is reported if there - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 56
and associated power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure SMX_SAStorageEnclosureProcessor Opaque Key Other CIM_ComputerSystem 2 (Other) Other Vendor Specific Name SDE-Indicates Storage Device Enclosure Port Number:BoxNumber enclosure - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 57
Table 4-13 Class: SMX_SAPortController (CIM_PortController) Property name ElementName EnabledDefault EnabledState RequestedState CreationClassName DeviceID SystemCreationClassName SystemName ControllerType OtherControllerType Property implementation CIM_ManagedElement Controller name and location - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 58
Table 4-14 Class: SMX_SASPIPort (CIM_SPIPort) Property name ElementName OperationalStatus[0] EnabledDefault EnabledState RequestedState CreationClassName DeviceID SystemCreationClassName SystemName UsageRestriction Property implementation Controller name and location Smart Array in Slot=3 Smart - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 59
Table 4-15 Class: SMX_ SAFirmware (CIM_SoftwareIdentity) Property name Caption Description ClassificationDescriptions[0] Classifications[0] InstanceID Manufacturer IdentityInfoType IdentityInfoValue VersionString Property implementation CIM_LogicalElement Array Controller Firmware Array Controller - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 60
Table 4-16 Class: SMX_SAEnclosureFirmware (CIM_SoftwareIdentity) Property name IdentityInfoType IdentityInfoValue VersionString Property implementation CIM:SoftwareFamily HPQ:SoftwareCategory HPQ: [1] Storage Device Enclosure firmware string HPSA_EnclosureFirmware 4-3-16 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 61
Opaque key Controller serial number:, where is the array number as supplied from API Always set to FALSE Remaining raw space in current pool Total HPSA_MediaAccessStatData See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 62
HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile See HP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 63
Table 4-20 Class: SMX_SAStorageSetting (CIM_StorageSetting) Property name InstanceID ChangeableType DataRedundancyGoal DataRedundancyMax DataRedundancyMin DeltaReservationGoal DeltaReservationMax DeltaReservationMin NoSinglePointOfFailure PackageRedundancyGoal PackageRedundancyMax - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 64
N/A-Not available in this implementation CIM_PhysicalPackage 2 (Not Applicable) HP_DriveCage See HP Smart Array Profile See HP Smart Array Profile See HP Smart Array Profile HPSA_DriveCage 4-3-21 SMX_SASCSIProtocolEndpoint SMX_SASCSIProtocolEndpoint implements the HPSA_SCSIProtocolEndpoint class - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 65
.Name CIM_ProtocolEndpoint 1(Other) SCSI CIM_SCSIProtocolEndpoint 1 (Other) PCI 0 (Unknown) 2 (Initiator) 3 (Target) 4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint 4-3-22 SMX_SASCSIProtocolController SMX_SASCSIProtocolController implements the HPSA_SCSIProtocolController class and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 66
Table 4-23 Class: SMX_SASCSIProtocolController (CIM_SCSIProtocolController) Property name OperationalStatus[0] EnabledDefault EnabledState RequestedState CreationClassName DeviceID SystemCreationClassName SystemName MaxUnitsControlled Property implementation Operational status of the controller 0 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 67
Table 4-24 Class: SMX_SARedundancySet (CIM_RedundancySet) Property name RedundancyStatus TypeOfSet[0] Property implementation 2 (Fully Redundant) 4 (Redundancy Lost) 4 (Sparing) HPSA_RedundancySet 4-3-24 SMX_SAStorageRedundancySet SMX_SAStorageRedundancySet implements the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 68
CIM_SystemSpecificCollection Opaque key HP_GroupSystemSpecificCollection Consolidated status for all array controllers. See section 9.10 Consolidated status example of HP Smart Array profile for details on how this value is calculated. Description of failure HPSA_StorageSpecificCollection 4-3-26 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 69
Table 4-27 Class: SMX_SADriveCageLocation (HP_Location) Property name LocationInformation[0] LocationInfoDesc[0] Property implementation HBA Port identifier Examples: • J3 • 2I • 1E Port HPSA_DriveCageLocation 4-3-27 SMX_SAArraySystemLocation SMX_SAArraySystemLocation implements the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 70
- Port: 1E Box 1 Bay: 5 CIM_Location Opaque key Opaque key HP_Location Bay Number of Disk Drive- When Bay is specified in ElementLocationTagDesc. 20 (Bay)-When firmware supports Bay numbering Smart Array 70 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 71
Table 4-29 Class: SMX_SADiskDriveLocation (HP_Location) Property name Property implementation HPSA_DiskDriveLocation 4-3-29 SMX_SAArrayControllerLocation SMX_SAArrayControllerLocation implements the HPSA_ArrayControllerLocation class and represents a location string for the array controller. - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 72
Table 4-30 Class: SMX_SArrayControllerLocation (HP_Location) Property name LocationInformation[0] LocationInfoDesc[0] Property implementation For internal HBAs: PCI Slot number Examples: • 3-PCI Slot 3 • 0-Embedded on Motherboard 3 (PCI Slot)-For internal HBAs (Embedded Device) - for internal HBA - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 73
internal • Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_Product Opaque key String representing the Marketing name HP Firmware version of HBA or Storage System Smart Array 73 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 74
Table 4-32 Class: SMX_SAProduct (CIM_Product) Property name Property implementation HPSA_Product 4-3-32 SMX_SAStorageEnclosureLocation SMX_SAStorageEnclosureLocation implements the HPSA_StorageEnclosureLocation class and represents a location string for the enclosure. Table 4-33 Class: - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 75
4-3-34 SMX_SAStorageVolumeStorageSetting (Association) Table 4-35 Class: SMX_SAStorageVolumeStorageSetting (CIM_ElementSettingData) Property name ManagedElement SettingData IsCurrent IsDefault Property implementation SMX_SAStorageVolume SMX_SAStorageSetting 1 (Set to Is Current) 1 (Set to Is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 76
Table 4-39 Class: SMX_SAArraySystemSCSIProtocolController (CIM_SystemDevice) PartComponent SMX_ SASCSIProtocolController 4-3-39 SMX_SAArraySystemPortController (Association) Table 4-40 Class: SMX_SAArraySystemPortController (CIM_Logicaldentity) Property name SameElement SystemElement Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 77
Table 4-44 Class: SMX_SAArraySystemSPIPort (CIM_SystemDevice) GroupComponent SMX_SAArraySystem PartComponent SMX_ SASPIPort 4-3-44 SMX_SAArraySystemDAPort (Association) Table 4-45 Class: SMX_SAArraySystemDAPort (CIM_SystemDevice) Property name GroupComponent PartComponent Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 78
4-3-48 SMX_SAArraySystemArrayController (Association) Table 4-49 Class: SMX_ SAArraySystemArrayController (CIM_ComponentCS) Property name GroupComponent PartComponent Property implementation SMX_SAArraySystem SMX_SAArrayController 4-3-49 SMX_SAStorageEnclosureStorageEnclosureProcessor ( - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 79
4-3-53 SMX_SAPhysicalPackageDiskPhysicalPackage (Association) Table 4-54 Class: SMX_SAPhysicalPackageDiskPhysicalPackage (CIM_Container) Property name GroupComponent PartComponent Property implementation SMX_SAPhysicalPackage SMX_SADiskPhysicalPackage 4-3-54 SMX_SAPhysicalPackageStorageEnclosure - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 80
Table 4-58 Class: SMX_SAPrimordialPoolStorageExtent (CIM_ConcreteComponent) PartComponent SMX_SAStorageExtent 4-3-58 SMX_SAStorageSpecificCollectionArraySystem (Association) Table 4-59 Class: SMX_SAStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Collection Member - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 81
4-3-62 SMX_SASCSIProtocolControllerStorageVolume (Association) Table 4-63 Class: SMX_SASCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent SMX_SASCSIProtocolController Dependent SMX_SAStorageVolume DeviceAccess 2 (Read Write) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 82
4-3-65 SMX_SADiskDriveDiskDriveFirmware (Association) Table 4-66 Class: SMX_SADiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Antecedent Dependent ElementSoftwareStatus Property implementation SMX_SADiskDriveFirmware SMX_SADiskDrive ElementSoftwareStatus[0]: 2 (Current) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 83
Table 4-70 Class: SMX_SAPrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Antecedent SMX_SAPrimordialPool Dependent SMX_SAStoragePool SpaceConsumed Bytes consumed by storage pool 4-3-70 SMX_SASpareExtentStorageExtent (Association) Table 4-71 Class: SMX_SASpareExtentStorageExtent ( - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 84
4-3-74 SMX_SASPIPortSCSIProtocolEndpoint (Association) Table 4-75 Class: SMX_ SASPIPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Antecedent Dependent Property implementation SMX_SASPIPort SMX_SASCSIProtocolEndpoint 4-3-75 SMX_SAStorageGroupHostedCollection (Association) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 85
4-3-79 SMX_SAArrayControllerPhysicalPackageArrayControllerL ocation (Association) Table 4-80 Class: SMX_SAArrayControllerPhysicalPackageArrayControllerLocation (CIM_PhysicalElementLocation) Property name Element PhysicalLocation Property implementation SMX_SAArrayControllerPhysicalPackage - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 86
implementation SMX_SAStorageEnclosure SMX_SAStorageEnclosureLocation 4-4 Supported indications 4-4-1 HP_DeviceIndication: ProviderName Property implementation CIM_Indication GUID string generated at indication event or time of the indication if event time is unknown HP SmartArray Smart Array 86 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 87
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 88
Changed to ERROR Table 4-87 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name IndicationIdentifier IndicationIdentifier Property implementation CIM_Indication GUID string generated at indication CIM_Indication GUID string generated at the time of indication Smart Array 88 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 89
Error WBEM Path of SMX_SADiskDrive class 2 (CIMObjectPath) 5 (Device Alert) 202 Time of the event or time of the indication if event time unknown HP Smart Array Check for failed or removed physical drives. Name of the computer system generating the indication CreationClassName of the computer system - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 90
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 91
AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation CIM_Indication GUID string generated at the time of indication 2 ) 5 (Device Alert) 203 Time of the event or time of the indication if event time unknown HP Smart Array Smart Array 91 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 92
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 93
4-4-3 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Table 4-88 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HWFirmwareVersion HWLogicalLocation Property implementation Rack name - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 94
ProviderVersion SystemFirmwareVersion Property implementation CIM_Indication GUID string generated at the time Device Alert) 203 Time of the event or time of the indication if event time unknown HP Smart Array Replace drive immediately to avoid loss of data Name of the computer system generating - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 95
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 96
AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation CIM_Indication GUID string generated at the time of indication 2 ( ) 5 (Device Alert) 101 Time of the event or time of the indication if event time unknown HP Smart Array Smart Array 96 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 97
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 98
4-4-5 HPSA_StorageVolumeIndication: Logical Drive Status Changed to OK Table 4-90 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HWLogicalLocation VariableNames VariableTypes VariableValues - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 99
ProviderVersion SystemFirmwareVersion Property implementation CIM_Indication GUID string generated at the time (Device Alert) 102 Time of the event or time of the indication if event time unknown HP Smart Array Check for failed or removed physical drives. Name of the computer system generating the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 100
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 101
AlertingMangedElement AlertingElementFormat AlertType Property implementation CIM_Indication GUID string generated at the time of indication 2 (Info) Time of indication CIM_AlertIndication A logical drive is in a degraded state, Device is still servicing I/O but redundancy may be degraded or - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 102
103 Time of the event or time of the indication if event time unknown HP Smart Array Check status of physical drives. Degraded status may be caused by failed Model name of the computer system generating the indication Platform GUID of the computer system generating the indication Smart Array 102 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 103
4-4-7 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Table 4-92 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 104
SystemName SystemCreationClassName Property implementation CIM_Indication GUID string generated at the time Alert) 1 Time of the event or time of the indication if event time unknown HP Smart Array No action is recommended. Name of the computer system generating the indication CreationClassName of - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 105
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 106
HP_DeviceIndication: Controller Status Changed to ERROR Property name IndicationIdentifier PerceivedSeverity IndicationTime Description Property implementation CIM_Indication GUID string generated at the time of indication 5 (Major) Time of indication CIM_AlertIndication A Smart Array controller - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 107
or time of the indication if event time unknown HP Smart Array Check controller status and run diagnostics. Name of the computer system generating the indication CreationClassName computer system generating the indication Platform GUID of the computer system generating the indication Smart Array 107 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 108
4-4-9 HP_DeviceIndication: Controller Status Changed to ERROR Table 4-94 HP_DeviceIndication: Controller Status Changed to ERROR Property name ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID HWFirmwareVersion HWLogicalLocation - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 109
OSVersion ProviderVersion Property implementation CIM_Indication GUID string generated at indication 3 5 (Device Alert) 3 Time of the event or time of the indication if event time unknown HP Smart Array Check status of all controllers. An array controller may have failed causing this controller to - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 110
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 111
ProviderName RecommendedActions SystemName Property implementation CIM_Indication GUID string generated at the time of Alert) 4 Time of the event or time of the indication if event time unknown HP Smart Array Check status of the partner array controller. Name of the computer system generating the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 112
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 113
Array Controller Model string 4-4-12 HP_DeviceIndication: Controller Redundancy has been restored Table 4-97 HP_DeviceIndication: Controller Redundancy has been restored Property name IndicationIdentifier Property implementation CIM_Indication GUID string generated at indication Smart Array 113 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 114
WBEM path to the SMX_SAArrayController class. 2 (CIMObjectPath) 5 (Device Alert) 5 Time of the event or time of the indication if event time unknown HP SmartArray No Action needed Name of the computer system generating the indication CreationClassName of the computer system generating the indication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 115
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 116
SystemName SystemCreationClassName Property implementation CIM_Indication GUID string generated at indication 2 Alert) 6 Time of the event or time of the indication if event time unknown HP SmartArray No action needed. Name of the computer system generating the indication CreationClassName of the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 117
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 118
not fully charged Table 4-99 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name IndicationIdentifier PerceivedSeverity IndicationTime Property implementation CIM_Indication GUID string generated at indication 3 (Warning) Time of indication Smart Array 118 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 119
. WBEM path to the SMX_SAArrayController class. 2 (CIMObjectPath) 5 (Device Alert) 7 Time of the event or time of the indication if event time unknown HP Smart Array Check Battery operation allow time for the battery to become fully charged. Name of the computer system generating the indication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 120
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 121
RecommendedActions SystemName SystemCreationClassName Property implementation CIM_Indication GUID string generated at the time ) 8 Time of the event or time of the indication if event time unknown HP SmartArray Check battery connection - replace if necessary. Name of the computer system generating - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 122
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 123
- OK Table 4-101 HP_DeviceIndication: Controller Cache status changed to OK Property name IndicationIdentifier PerceivedSeverity IndicationTime Property implementation CIM_Indication GUID string generated at the time of indication 2 (Info) Time of indication CIM_AlertIndication Smart Array 123 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 124
path to the SMX_SAArrayController class. 2 (CIMObjectPath) 5 (Device Alert) 9 Time of the event or time of the indication if event time unknown HP SmartArray No Action required Name of the computer system generating the indication CreationClassName of the computer system generating the indication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 125
* RackUID * SystemVirtualSerialNumber SystemVirtualUUID HWFirmwareVersion HWLogicalLocation HWManufacturer HWSerialNumber VariableNames[] VariableTypes[] VariableValues[] Property implementation Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 126
Summary EventCategory Property implementation CIM_Indication GUID string generated at the time 10 Time of the event or time of the indication if event time is unknown HP SmartArray No Action required Name of the computer system generating the indication CreationClassName of the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 127
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 128
4-103 HP_DeviceIndication: Controller Cache status-Permanently Disabled Property name IndicationIdentifier PerceivedSeverity IndicationTime Property implementation CIM_Indication GUID string generated at the time of indication 3 (Warning) Time of indication CIM_AlertIndication Smart Array 128 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 129
to a status of Permanently Disabled. Controller has detected a problem with the cache and has disabled the cache permanently. WBEM time of the indication if event time is unknown HP SmartArray Check Cache controller error code. Run diagnostics. Name of the computer system generating the indication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 130
HWLogicalLocation HWManufacturer HWSerialNumber VariableNames[] VariableTypes[] Property implementation Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 131
GUID string generated at the time of indication 3 (Warning) Time of indication CIM_AlertIndication Storage Enclosure Power if event time unknown HP SmartArray Check status of all enclosure power supplies. Problem may be caused by a failed power supply. Add or replace power supplies as necessary. Name - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 132
HP_AlertIndication Power Supply Status changed to Non-Redundant. 17 (Primary Storage Power) 89 (Power Supply Failure) Redundant Power Supply Status indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 133
: Enclosure Power Supply status changed to OK (Redundant) Property name IndicationIdentifier PerceivedSeverity IndicationTime Description AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName Property implementation CIM_Indication GUID string generated - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 134
HP_AlertIndication Power Supply Status changed to OK - Redundant Power Supply 17 (Primary Storage Power) 1 (Other) Redundant Power Supply Status indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 135
Table 4-106 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name IndicationIdentifier PerceivedSeverity IndicationTime Description AlertingMangedElement AlertingElementFormat AlertType EventID Property implementation CIM_Indication GUID string generated at - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 136
unknown HP SmartArray Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 137
to Redundant Degraded Table 4-106 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name BladeBay IndicationTime Description AlertingMangedElement AlertingElementFormat Property implementation CIM_Indication GUID string generated at indication 2 (Info) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 138
Time of the event or time of the indication if event time unknown HP SmartArray No Action required. Name of the computer system generating the indication CreationClassName of the computer system generating the indication Platform GUID of the computer system generating the indication Smart Array 138 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 139
Table 4-108 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name IndicationIdentifier PerceivedSeverity IndicationTime Property implementation CIM_Indication GUID string generated at indication 3 (Warning) Time of indication CIM_AlertIndication Smart Array 139 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 140
WBEM Path of SMX_SAStorageEnclosureProcessor 2 (CIMObjectPath) 5 (Device Alert) 308 Time of the event or time of the indication if event time unknown HP SmartArray Verify that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 141
implementation Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 142
NetworkAddresses OSType OSVersion Property implementation GUID string generated at indication 5 Alert) 309 Time of the event or time of the indication if event time unknown HP SmartArray Ensure that the system is adequately ventilated. Check for proper room temperature and internal/ - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 143
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 144
OSType OSVersion ProviderVersion Property implementation CIM_Indication GUID string generated at indication 2 (Info Time of the event or time of the indication if event time is unknown HP SmartArray No action required Name of the computer system generating the indication CreationClassName of - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 145
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 146
of Degraded. An enclosure has detected there may a problem with one or more of the fans. WBEM Path of SMX_SAStorageEnclosureProcessor 2 (CIMObjectPath) 5 (Device Alert) 305 Time of the event or time of the indication if event time unknown HP SmartArray Ensure that the system is adequately ventilated - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 147
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 148
SystemName SystemCreationClassName Property implementation CIM_Indication GUID string generated at the time ) 306 Time of the event or time of the indication if event time unknown HP SmartArray Verify that the system is adequately ventilated. Check for proper room temperature and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 149
the indication Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 150
4-4-27 HP_DeviceIndication: Enclosure Fan status changed to Failure Table 4-112 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name SystemVirtualUUID HWLogicalLocation HWSerialNumber DeviceModel Property implementation Conditional property containing the virtual system UUID - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 151
Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA's and the attached devices. The current View Class implementation does not support externally attached Controller product name and controller index For example, HP Smart Array P400 Controller : HPSA1 Note: Each - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 152
Smart Array Controller X Firmware CIM_LogicalElement Smart Array Controller X Firmware CIM_SoftwareIdentity HPQ:Smart Array Controller X HP Smart Array controller firmware version For example, 4.12 HPVC_SAControllerFirmware 5-2-3 HPVC_SABattery HPVC_SABattery represents Smart Array controller - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 153
SystemCreationClassName SystemName BatteryStatus Property implementation CIM_ManagedSystemElement CIM_LogicalElement CIM_LogicalDevice HPVC_SABattery Battery on HPSA X SMX_ComputerSystem Server host name CIM_Battery 1(Other) 2(Unknown) 3(Fully Charged) 4(Low) 5(Critical) 6(Charging) 7(Charging and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 154
Y on HPSA X CIM_EnabledLogicalElement CIM_LogicalDevice HPVC_SAStorageExtent HPVC_SAStorageExtent-- For example, HPVC_SAStorageExtentHPDG072BB975-3NP2TCCF000098402P95 SMX_ComputerSystem Server host name CIM_StorageExtent Block size in bytes Total number of blocks on disk drive - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 155
) CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice HPVC_SAStorageVolume HPVC_SAStorageVolume- For example, HPVC_SAStorageVolume600508b10010463956564636454e0007 SMX_ComputerSystem Server host name CIM_StorageExtent Block size in bytes Total number of blocks on disk - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 156
as: Fans, Power Supplies, Processor and Memory (Volatile and/or Non-Volatile Storage). Table 6-1 Implemented Profiles Profile name HP Base Server Profile (P00105) HP Base Server Physical Asset Profile (P00114) HP Software Inventory (P00127) Organization HP WBEM TC HP WBEM TC HP WBEM TC Version - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 157
the subsystems that make up the overall operational status are contained in OperationalStatus[1-n]. See the descriptions for GroupOperationalStatus for the list of possible values. Base server 157 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 158
) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName SMX_ComputerSystem Roles Computer system roles string: initialized to not set CIM_ComputerSystem Base server 158 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 159
[0]: where is the computer system physical GUID string OtherIdentifyingInfo[1]: where is the computer IdentifyingDescriptions[6] HPQ:SMXTarget 0 (Not Dedicated) HP_ComputerSystem Computer system DNS name returned by uname DNSName Base server 159 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 160
The computer system physical serial number string. IdentifyingNumber The computer system physical GUID string. Model The computer system model string. SMX_ComputerSystem Table 6-3 Class: again. Exceptions: CIM_ERR_INVALID_PARAMETER - EventID is not one of the defined values Base server 160 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 161
There is only one instance of SMX_ComputerSystemChassis instantiated on a server. Table 6-4 Class: SMX_ComputerSystemChassis Property name Tag CreationClassName ElementName for definitions. This value is retrieved from SMBIOS 0 (Unknown) 1 (True) 2 (False) HP_ComputerSystemChassis Base server 161 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 162
class CIM_OperatingSystem to model the system operating system. There is only one instance of SMX_OperatingSystem instantiated on a server. Table 6-6 Class: SMX_OperatingSystem Property name Caption Description ElementName Property implementation CIM_ManagedElement On ESX, output of vmware -v On - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 163
, Embedded On Linux, NULL On ESX, 39(VM) On Linux, 36 (Linux) Current time Time when the operating system was last booted SMX_OpertingSystem 6-3-5 SMX_RunningOS SMX_RunningOS implements the class CIM_RunningOS and associates the SMX_ComputerSystem instance and an SMX_OperatingSystem instance. Base - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 164
SMX_InstalledOS 6-3-7 SMX_BaseServerECTP The SMX_BaseServerECTP class extends the class CIM_ElementConformsToProfile and associates the Base Server registered profile with the HP specific central class that defined the implementation of the profile. Table 6-9 Class: SMX_BaseServerECTP Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 165
of the SMX product, for example: HPs Standards Management eXtensions (SMX) are WBEM Providers, using DMTF standard profiles. hp-smx CIM_ManagedSystemElement 2 (OK) 0 Description the following: CIM:SoftwareFamily IdentityInfoType[1] will contain the following: HPQ:SoftwareCategory Base server 165 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 166
[0] will contain the following: HPQ:hp-smx IdentityInfoValue[1] will contain the following server system. Table 6-12 Class: CIM_SystemFirmware Property name Caption Description ElementName Name Property implementation CIM_ManagedElement A description of the firmware. For example, on ProLiant - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 167
FCode) System Firmware On ProLiant, this will contain: HPQ: where is the system ROM family code For example, HPQ:P31 On Integrity, this will contain: SMX_SystemInstalledFirmwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity Base server 167 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 168
) SMX_SystemElementFirmwareIdentity ref: SMX_SystemFirmware ref: HP_ComputerSystem 6-4 Supported indications The following table describes the properties that are common to all of the SMX Base Server Provider indications that are implement for server platforms, where available. Table 6-15 Provider - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 169
indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 6-4-1 HP_DeviceIndication: WBEM Providers tables describe the SMX Base Server Provider indications that are implemented for all server platforms. Table 6-16 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 170
CIM_AlertIndication SMX WBEM Providers have started 5 (Device Alert) 1 HP WBEM No action is recommended. HP_AlertIndication WBEM Providers started 1 ( CIM_AlertIndication This is an information test event 5 (Device Alert) 1 HP Test No action is recommended. HP_AlertIndication Test Event 1 (Other) - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 171
) CIM_AlertIndication This is a warning test event 5 (Device Alert) 2 HP Test No action is recommended. HP_AlertIndication Test Event 1 (Other) Test 6 (Critical) CIM_AlertIndication This is a Critical Test Event 5 (Device Alert) 3 HP Test No action is recommended. HP_AlertIndication Base server 171 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 172
6-4-4 HP_DeviceIndication: WBEM Providers Critical Test Indication Table 6-19 HP_DeviceIndication: WBEM Providers Critical Test Indication Property name Summary ProbableCause ProbableCauseDescription Property implementation Test Event 1 (Other) Test Indication Base server 172 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 173
profiles implemented and files installed by this provider. Table 7-1 Overview Implemented Profiles HP CPU Profile (P00106) HP CPU Consolidated Status Profile (P00107) HP CPU Physical Asset Profile (P00108) HP Location Profile (P00124) 7-2 Namespaces This provider returns instances in the root/hpq - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 174
Table 7-2 Class: HP_Processor Properties Property name Caption Description ElementName Name OperationalStatus StatusDescriptions Property implementation CIM_ManagedElement Processor in ProcessorBaord=a, where a is the slot number Processor in socket=b on System Mainboard, where b is the socket - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 175
Table 7-2 Class: HP_Processor Properties Property name HealthState EnabledState RequestedState EnabledDefault SystemCreationClassName SystemName CreationClassName DeviceID CPUStatus Family MaxClockSpeed CurrentClockSpeed DataWidth AddressWidth ExternalBusClockSpeed Characteristics Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 176
Table 7-2 Class: HP_Processor Properties Property name NumberOfEnabledCores Stepping Role Unique ID Property implementation Number of enabled and operational cores for this processor (for example, 1, 2, 4) Stepping for processor Processor Role Unique identifier for processor HP_Processor 7-3-2 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 177
Table 7-4 Class: SMX_ProcessorCore Property name Caption Description ElementName Name OperationalStatus StatusDescriptions HealthState EnabledState RequestedState Property implementation CIM_ManagedElement Processor:p - Core:c, where p is the processor number and c is the core number - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 178
Table 7-4 Class: SMX_ProcessorCore Property name EnabledDefault InstanceID CoreEnabledState Characteristics Bootstrap Property implementation 2 (Enabled) CIM_ProcessorCore HPQ:SMX_ProcessorCore:Proc:p Core:c, where p is the processor number and c is the core number. 2 (Core Enabled) For x86 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 179
Table 7-5 Class: SMX_HardwareThread Property name OperationalStatus StatusDescriptions HealthState EnabledState RequestedState EnabledDefault InstanceID Property implementation 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 180
Table 7-6 Class: SMX_CacheMemory Property name Caption Description ElementName OperationalStatus StatusDescriptions HealthState Property implementation One of the following: Level x Data Cache, where x is the cache level number Level x Insturction Cache, where x is the cache level number Level x - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 181
the following: Proc p, Level x Cache, where p is the processor number, x is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc p, Core c, Level x Cache, where p is the processor number, c is the core number, x is the cache level number, and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 182
Table 7-7 Class: SMX_SystemProcessor Property name GroupComponent PartComponent Property implementation CIM_SystemDevice HP_SystemProcessor ref: SMX_ComputerSystem ref: SMX_Processor 7-3-7 SMX_ProcessorElementCapabilities SMX_ProcessorElementCapabilities extends the class CIM_ElementCapabilities - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 183
0 (Unknown) 1 (Other) 2 (Not Applicable) 3 (Primary) 4 (Secondary) 5 (Tertiary) 0 (Unknown) 1 (Other) 2 (Write Back) 3 (Write Through) 4 (Varies with Address) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) 2 (Instruction) 3 (Data) 4 (Unified) Cache line size in bytes CPU 183 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 184
Table 7-11 Class: SMX_AssociatedProcessorCacheMemory Property name Read Policy Associativity Antecedent Dependent Property implementation 0 (Unknown) 1 (Other) 2 (Read) 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) 0 (Unknown) 1 (Other) 2 (Direct Mapped) 3 (2-way Set-Associative - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 185
Table 7-12 Class: SMX_ProcessorCollection Property name GroupOperationalStatus GroupStatusDescriptions Property implementation GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 ( - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 186
Table 7-13 Class: SMX_HostedProcessorCollection Property name Antecedent Dependent Property implementation HP_ProcessorGroupHostedCollection ref: SMX_ComputerSystem ref: SMX_ProcessorCollection 7-3-13 SMX_MemberOfProcessorCollection SMX_MemberOfProcessorCollection extends the class - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 187
Table 7-15 Class: SMX_ProcessorChip Properties Property name OperationalStatus StatusDescriptions HealthState Tag Description Property implementation 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 188
Table 7-15 Class: SMX_ProcessorChip Properties Property name CreationClassName ElementName Manufacturer Model Version PoweredOn CanBeFRUed RemovalConditions ProcessorChipRevision Property implementation SMX_ProcessorChip Processor in ProcessorBoard=a" where a is the slot number Processor in socket - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 189
is denoted by the use of a slot number designator and a socket number designator. Either value might be zero, depending on the system: • On older ProLiant systems, the processors are mounted on processor boards that fit in slots in the system. The slot number designator indicates the processor board - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 190
Table 7-18 Class: SMX_ProcessorLocation Property name ElementName Name PhysicalPosition ElementLocationTag ElementLocationTagDesc LocationInformation Property implementation Processor in ProcessorBaord=a, where a is the slot number Processor in socket=b on System MainBoard, where b is the socket - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 191
Property name Element PhysicalLocation Property implementation CIM_ElementLocation HP_ElementLocation HP_ProcessorElementLocation ref: SMX_ProcessorChip ref: SMX_ProcessorLocation 7-4 Supported indications The following table describes the properties that are common to all of the SMX - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 192
Product ID of the computer system generating the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 7-4-1 HP_DeviceIndication: Processor Failed Post Table 7-21 HP_DeviceIndication: Processor Failed Post Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 193
Failed Power on Self Test (POST) 5 (Device Alert) 1 2 (Processor) HP Processor Replaced the failed processor HP_AlertIndication CPU Failed Power on been disabled by BIOS or EFI 5 (Device Alert) 2 2 (Processor) HP Processor Enable processor via BIOS or EFI HP_AlertIndication CPU is disabled by BIOS or - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 194
RecommendedActions Summary ProbableCause Property implementation CIM_Indication 4 (Minor) CIM_AlertIndication CPU Predictive Failure Notification 5 (Device Alert) 3 2 (Processor) HP Processor Replace the failing processor. HP_AlertIndication CPU Predictive Failure detected 1 (Other) CPU 194 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 195
provider implements the classes listed to support fans installed in servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles HP Fan Profile 1.0 (P102) HP Location Profile 1.0 (P124) HP Fan Physical Location Profile - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 196
Table 8-2 Class: SMX_Fan Property name Caption Description ElementName OperationalStatus[0] StatusDescriptions[0] HealthState Name CreationClassName DeviceID SystemCreationClassName SystemName Property implementation CIM_ManagedElement Short description of this fan from the name displayed by the MP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 197
variable speed False-if fan does not support variable speed or is unknown HP_Fan Enumeration describing the type of fan (see MOF) 8-3-2 SMX_FanCollection SMX_FanCollection is used to model fan collections on Servers. There will be one instance of this class on systems modeling fans. Table - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 198
, if GroupOperationalStatus[0] is 6 (Error) 8-3-3 SMX_FanRedundancySet SMX_FanRedundancySet is used to model fan redundancy sets on Servers. Table 8-4 Class: SMX_FanRedundancySet Property name Caption Description ElementName Property implementation CIM_ManagedElement Short description of this - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 199
Property implementation CIM_SystemSpecificCollection Unique identifier for this cooling redundancy instance CIM_RedundancySet Represents the maximum number of fans supported for this redundancy set Represents the minimum number of fans needed to function 3 (Load Balanced) 0 (Unknown) 0 (Unknown - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 200
contains this fan. Table 8-9 Class: SMX_SystemFan Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_Fan 8-3-9 SMX_FanLocation HP_FanLocation is used to model fan locations on Servers. System Fan 200 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 201
this fan location instance Physical position of this fan. For example on ProLiant number of the fan position printed on the system HP_Location Location string based 8-3-11 SMX_FanModule SMX_FanModule is used to model physical fans on Servers. Please note: Fan numbers for existing instances do not - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 202
Table 8-12 Class: SMX_FanModule Property name Caption Description ElementName OperationalStatus[0] StatusDescriptions[0] HealthState Name CreationClassName Tag RemovalConditions PackageType Property implementation Short description of this fan from the name displayed by the MP or iLO. For example: - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 203
implementation References HP_FanModule References HP_Fan 8-3-14 SMX_FanSlot SMX_FanSlot is used to model physical fan slots on Servers. Table 8-15 Class: SMX_FanSlot Property name Caption Description ElementName OperationalStatus[0] StatusDescriptions[0] HealthState Name CreationClassName Tag - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 204
References HP_FanSlot References HP_FanModule 8-4 Supported indications 8-4-1 Provider Indication Common Properties server platforms, where available. Table 8-18 Provider Indication Common Properties Property name IndicationIdentifier IndicationTime Property implementation CIM_Indication GUID - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 205
Model name of the computer system generating the indication Platform GUID of the computer system generating the indication 8-4-2 HP_DeviceIndication: Fan Removed The following indications are implemented for ProLiant server platforms where available. System Fan indications are described below - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 206
RecommendedActions Summary EventCategory ProbableCause ProbableCauseDescription Property implementation WBEM Path of the SMX_Fan instance 2 (CIMObjectPath) 5 (Device Alert) 1 HP Cooling Check the fan configuration and ensure that this fan was removed intentionally. HP_AlertIndication Fan removed 23 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 207
is the SMX_Fan.Caption for the fan that has failed WBEM path of the SMX_Fan instance representing the failed fan 2 (CIMObjectPath) 5 (Device Alert) 3 HP Cooling Please check the failed fan and replace if necessary. HP_AlertIndication Fan failed 23 (System Cooling) 94 (Fan Failure) Fan Failed - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 208
the failed fan 2 (CIMObjectPath) 5 (Device Alert) 4 HP Cooling No action is recommended. HP_AlertIndication Fan repaired 23 (System Cooling) 1 (Other) Fan Repaired 8-4-6 HP_DeviceIndication: Fan Degraded The repaired indication is not supported on ProLiant Systems as the fans do not report - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 209
HP_DeviceIndication: Fan Degraded The repaired indication is not supported on ProLiant Systems as the fans do not report a redundancy set with reduced redundancy 2 (CIMObjectPath) 5 (Device Alert) 5 HP Cooling No action is recommended. HP_AlertIndication Cooling redundancy has been reduced System - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 210
set that lost redundancy. WBEM path of the SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost. 2 (CIMObjectPath) 5 (Device Alert) 6 HP Cooling Check the fan configuration and check the status of the cooling redundancy. Ensure the system is being cooled adequately - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 211
Alert) 8 HP Cooling No action is recommended. HP_AlertIndication Cooling redundancy has been restored 23 (System Cooling) 1 (Other) Cooling Redundancy has been Restored 8-4-10 HP_DeviceIndication: Fan Redundancy Failed The redundancy failed indication is not supported on ProLiant systems since - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 212
: Fan Redundancy Failed The redundancy failed indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond set with failed redundancy 2 (CIMObjectPath) 5 (Device Alert) 10 HP Cooling Check the fan configuration and check the status of the cooling redundancy - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 213
by this provider. Table 9-1 Overview Implemented Profiles HP Power Supply Profile 1.0 (P103) HP Location Profile 1.0 (P124) HP Power Supply Physical Asset Profile 1.0 (P116) 9-2 Namespaces This is used to model power supplies on Servers. Please note: power supply numbers for existing instances - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 214
is 6 (Error) 5 (OK)-if the power supply is operating properly 10 (Degraded) if power supply is degraded 20 (Major Failure)-if the power supply has failed Power Supply n, where n represents the number of the power supply instance. Time that state last changed for power supply. 0 if it has not changed - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 215
) 12 (Not Applicable) CIM_PowerSupply 0 (denotes unknown) HP_PowerSupply Enumeration describing the type of power supply (see MOF) 9-3-2 SMX_PowerCollection SMX_PowerCollection is used to model power supply collections on Servers. There will be one instance of this class on systems modeling - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 216
have failed, if GroupOperationalStatus[0] is 6 (Error) 9-3-3 SMX_PowerRedundancySet SMX_PowerRedundancySet is used to model power supply redundancy sets on Servers. Table 9-4 Class: SMX_PowerRedundancySet Property name Caption Description ElementName Property implementation CIM_ManagedElement - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 217
CIM_RedundancySet The maximum number of power supplies supported for this redundancy set The minimum number of power supplies needed to function 3 (Load Balanced) 0 (Unknown) 0 (Unknown) - if the redundancy status is unknown 2 (Fully Redundant) - if the all power supplies in the set are operating - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 218
this power supply. Table 9-9 Class: SMX_PowerSupplyLocation Property name GroupComponent PartComponent Property implementation References HP_ComputerSystem References HP_PowerSupply 9-3-9 SMX_PowerSupplyLocation SMX_Location is used to model power supply locations on servers. System Power Supply - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 219
on the system labeling. Description of this power supply location, including the location. For example on Proliant:The location of the power supply n. Please refer to power supply position n printed on the system." where n represents the power supply position printed on the system labeling. User - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 220
9-3-11 SMX_PowerSupplyModule SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 9-12 Class: SMX_PowerSupplyModule Property name Caption Description - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 221
is used to model physical power supply slots on Servers. Table 9-15 Class: SMX_PowerSupplySlot Property name Caption Description Property implementation CIM_ManagedElement Short description of ths power supply slot to include the Number. For example, Power Supply Slot n, where n represents the bay - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 222
) - if fan is operating properly; Name of the power supply slot, For example: Power Supply n where n represents the number of the power supply slot. CIM_PhysicalElement SMX_PowerSupplySlot Unique identifier for this power supply slot CIM_PhysicalElement SMX_PowerSupplySlot Unique identifier for this - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 223
HP_PowerSupplySlot References HP_PowerSupplyModule 9-4 Supported indications 9-4-1 Provider Indication Common Properties The following table describes the properties that are common to all of the SMX Power Supply Provider indications that are implemented for server platforms, where available - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 224
system generating the indication Platform GUID of the computer system generating the indication 9-4-2 HP_DeviceIdentification: Power Supply Removed The following indications are implemented for ProLiant server platforms where available. System Power Supply indications are described below. Table - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 225
the inserted power supply 2 (CIMObjectPath) 5 (Device Alert) 2 HP Power No action is recommended. HP_AlertIndication Power Supply inserted 16 (System Power) 1 (Other) Power Supply has been Inserted 9-4-4 HP_DeviceIndication: Power Supply Failed Table 9-21 HP_DeviceIndication: Power Supply Failed - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 226
(Device Alert) 3 HP Power Check the failed power supply and replace if necessary. HP_AlertIndication Power supply failed 16 (System Power) 89 (Power Supply Failure) Power Supply Failed 9-4-5 HP_DeviceIndication: Power Supply Degraded Table 9-22 HP_DeviceIndication: Power Supply Degraded Property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 227
that has been repaired. WBEM path of the SMX_PowerSupply instance representing the failed power supply 2 (CIMObjectPath) 5 (Device Alert) 4 HP Power No action is recommended. HP_AlertIndication PowerSupplyCaption has been repaired, where PowerSupplyCaption is the HP_WinPowerSupply. Caption for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 228
(Device Alert) 5 HP Power No action is recommended. HP_AlertIndication Power redundancy has been reduced 16 (System Power) 88 (Loss of Redundancy) Power Redundancy has been Reduced 9-4-8 HP_DeviceIndication: Power Supply Redundancy Lost Table 9-25 HP_DeviceIndication: Power Supply Redundancy Lost - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 229
. Add or replace power supplies if necessary. HP_AlertIndication Power redundancy has been lost. 16 (System Power) 88 (Loss of Redundancy) Power Redundancy has been Lost 9-4-9 HP_DeviceIndication: Power Supply Redundancy Failed This indication is not supported on ProLiant systems since redundancy - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 230
Alert) 10 HP Power Check the power supply configuration and check the status of the power redundancy. Ensure the system is being powered adequately. Add or replace power supplies if necessary. HP_AlertIndication Power redundancy failed 16 (System Power) 88 (Loss of Redundancy) Power Redundancy has - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 231
Restored Property name ProviderName RecommendedActions Summary EventCategory ProbableCause ProbableCauseDescription Property implementation HP Power No action is recommended. HP_AlertIndication Power redundancy restored 16 (System Power) 1 (Other) Power redundancy restored System Power Supply 231 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 232
10-1 Overview The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles • HP Profile Registration Profile (POO100) 10-2 Namespaces This provider returns instances in the root/hpq namespace. 10-3 Class implementations The - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 233
profiles. Some implementations only support a subset of the profiles Server 1.0.0a DMTF Base Server Profile CPU 1.0.0c DMTF CPU Profile Fan 1.0.0a DMTF Fan Profile Power Supply 1.0.0c DMTF Power Supply Profile System Memory 1.0.0f DMTF System Memory Services 1.3.0 SNIA Block Services - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 234
HBA Profile The SMX_RegisteredProfile class extends the CIM_RegisteredProfile class and describes an implemented HP specific profile. SMX_RegisteredProfile is the main class clients use to determine if an HP specific profile has been implemented in the root/hpq namespace. The following tables list - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 235
HP Fan 1.0.0 HP Fan Profile HP Power Supply 1.0.0 HP Power Supply Profile HP Memory 1.0.0 HP Memory Profile HP Base Server Physical Asset 1.0.0 HP Base Server Physical Asset Profile HP CPU Physical Asset 1.0.0 HP CPU Physical Asset Profile HP Memory Physical Asset 1.0.0 HP Memory - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 236
extends the class CIM_ElementConformsToProfile and associates the Base Server registered profile with the HP specific central class that defined the implementation of the : CIM_RegisteredProfile ref: CIM_ManagedElement (HP_ComputerSystem for server and network profiles, the storage computer system - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 237
10-4 Supported indications There are no indications specific to the profile registration implementation. SMX Profile registration provider 237 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 238
Profile to model temperature sensors in ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 11-1 Overview Implemented Profiles HP Sensor Profile 1.0 11-2 Use cases See HP Sensor Profile for Use Cases. 11-2-1 Class implementations - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 239
Table 11-2 Class: SMX_NumericSensor Property name ElementName OperationalStatus[0] StatusDescriptions[0] HealthState Name CreationClassName DeviceID SystemCreationClassName SystemName EnabledDefault EnabledState RequestedState SensorType Property implementation Temperature Sensor " where - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 240
is crossed SupportedThresholds[0] = 5 (UpperThresholdFatal) if the system will immediately power down the system if the threshold is crossed Contains the threshold and is used to model temperature sensor collections on Servers. There is one instance of this class on systems - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 241
Table 11-3 Class: SMX_SensorCollection Property name Caption Description ElementName InstanceID GroupOperationalStatus[0] GroupStatusDescriptions[0] Property implementation CIM_ManagedElement Temperature Sensor Collection This is a collection of temperature sensors. GroupStatusDescription., where - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 242
name GroupComponent PartComponent Property implementation References SMX_ComputerSystem References SMX_NumericSensor 11-3 Supported indications The following indications are implemented for ProLiant server platforms where available. Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 243
Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Description AlertingManagedElement AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions SystemName SystemCreationClassName Summary EventCategory ProbableCause ProbableCauseDescription - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 244
Model name of the computer system generating the indication Platform GUID of the computer system generating the indication Contains the temperature name IndicationIdentifier PerceivedSeverity IndicationTime Property implementation CIM_Indication GUID string generated at the time of indication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 245
threshold 2 (CIMObjectPath) 5 (Device Alert) 2 Time of the event or time of the indication if event time unknown HP Temperature No action is recommended. HP_ComputerSystem.Name HP_ComputerSystem.CreationClassName HP_AlertIndication Threshold exceeded condition recovery 23 (System Cooling) 52 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 246
Exceeded Property name SystemGUID ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID Property implementation Platform GUID of the computer system generating the indication 3 (Enclosure) for c-Class blade systems 4 (System) for all - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 247
This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in ProLiant systems. See HP Advanced Memory Protection Technologies (TC060104TB) and product documentation for your ProLiant Server (available at http://www.hp.com). The following table - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 248
• SMX_MemberOfMemoryRedundancySet • SMX_HostedMemoryRedundancySet • SMX_SystemMemoryModuleSlot • SMX_SystemMemoryBoardSlot 12-2-1 SMX_Memory The class SMX_Memory represents logical memory on ProLiant Servers. There is one instance of this class. Table 12-2 Class: SMX_Memory Property name Caption - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 249
Degraded/Warning), when OperationalStatus[0]=3 (Degraded) System Memory CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Supported) 1 (byte) Capacity in bytes Capacity in bytes True System Memory False CIM_Memory Beginning address of the memory in kilobytes Ending address of the memory - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 250
ref: SMX_Memory SMX_SystemMemory 12-2-3 SMX_MemoryModule The class SMX_MemoryModule represents a physical memory module on ProLiant Servers. There is an instance of this class for each memory module present in the system. Empty memory module sockets will not be instantiated. NOTE: In the property - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 251
number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module Socket=y on ProcessorBoard=x, where: x the processor board number where the memory module is located y is the memory socket number where the memory module is located - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 252
is conditional. It is populated if the data is available. CIM_PhysicalComponent 3 (Removable when off) CIM_Chip CIM_PhysicalMemory Data width of memory module in bits Position of memory module in an interleave. This property is conditional; it will be populated if the data is available System - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 253
property is conditional. It is populated if the data is available. SMX_MemoryModule An array that contains raw Serial Presence Detect information for the memory module. Each array element contains a byte of the Spd. This property is conditional; it is populated if the data is available. Table 12 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 254
has been exceeded 12-2-4 SMX_MemoryBoard The class SMX_MemoryBoard represents a physical memory board on ProLiant Servers. There will be an instance of this class for each memory board present in the system. Empty memory board slots will not be instantiated. Table 12-6 Class: SMX_MemoryBoard - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 255
ProcessorBoard=x, where x is the processor board/cartridge number where the memory board is located. Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x , where x is the processor board/cartridge number where the - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 256
board is operating properly 2 (OK) OK Memory board contains a memory module that has correctable errors exceeding the condition for prefailure warranty. 3 (Degraded) Degraded Memory board has a configuration error, for example, there is a problem with the board release latch (unlock error) or - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 257
The class SMX_MemoryModuleSlot represents memory module slots on ProLiant Servers. There will be an instance of this class for each memory module socket in the system (whether the slot is occupied or not). (Note: In the property implementation descriptions below, memory module slots located on - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 258
=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located CIM_PhysicalConnector 1 (Other) 3 (Female) Memory Module Socket=y on MemoryBoard=x where: x is the board/cartridge number where - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 259
12-2-7 SMX_MemoryBoardSlot The class SMX_MemoryBoardSlot represents memory board slots on ProLiant Servers. There will be an instance of this class for each memory board slot in the system (regardless of the slot occupation). Table 12-10 Class: SMX_MemoryBoardSlot Property name Caption - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 260
Table 12-10 Class: SMX_MemoryBoardSlot Property name ConnectorDescription Number Property implementation Memory Board Slot MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Memory Board Slot ProcessorBoard=x, where x is the processor board/cartridge number - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 261
12-2-11 SMX_MemoryModuleSlotLocation The class SMX_MemoryModuleSlotLocation extends the CIM_Location class and represents memory module slot locations on ProLiant Servers. There will be an instance of this class for each memory module slot in the system (whether the slot is occupied or not - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 262
Socket Location Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located Memory Module Socket Location Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 263
12-2-12 SMX_MemoryBoardSlotLocation The class SMX_MemoryBoardSlotLocation extends the CIM_Location class and represents memory board slot locations on ProLiant Servers. There is an instance of this class for each memory board slot in the system (regardless of the slot occupation). Table 12 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 264
-15 Class: SMX_ MemoryModuleSlotLocation Property name PhysicalPosition ElementLocationTag ElementLocationTagDesc LocationInformation LocationInfoDesc Property implementation Opaque key. Example for memory board/cartridge/processor number 1: FF-FF-FF-FF-01-FF-FF-7A HP_Location Opaque key. Example - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 265
class SMX_SystemMemoryBoard represents an association between SMX_MemoryBoard and SMX_ComputerSystemChassis. There will be an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). Table 12-19 Class: SMX_SystemMemoryBoard Properties GroupComponent - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 266
12-2-17 SMX_MemoryRedundancySet The class SMX_MemoryRedundancySet represents memory board redundancy on ProLiant servers supporting Advanced Memory Protection (AMP). One instance of this class exists on systems supporting Advanced Memory Protection. This class will not be instantiated on non-AMP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 267
mode (the CurrentConfiguration mode does not match the TargetConfiguration mode). ○ System is operating in the TargetConfiguration mode but memory module(s) have correctable errors exceeding the condition for pre-failure warranty. HP_MemoryRedundancySet The current operating speed of the Advanced - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 268
contains one supported configuration. • Possible values are: • Advanced ECC • Online Spare • Mirrored • RAID • Lockstep 12-2-18 SMX_MemoryCollection The class SMX_MemoryCollection represents physical memory collections on ProLiant Servers. The collection comprehends physical memory modules and - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 269
: SMX_MemoryCollection Property name GroupOperationalStatus GroupStatusDescriptions Property implementation Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 270
The class SMX_MemberOfMemoryRedundancySet represents an association between SMX_MemoryBoard and SMX_MemoryRedundancySet. Table 12-25 Class: SMX_MemberOfMemoryRedundancySet Property name Property implementation CIM_MemberOfCollection HP_MemberOfMemoryRedundancySet System memory 270 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 271
and SMX_ComputerSystemChassis. There is an instance of this class for each memory module slot on the chassis system board (regardless of the occupation of the slot). Only system board resident memory module slots are instantiated. Table 12-27 Class: SMX_SystemMemoryModuleSlot - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 272
SMX_SystemMemoryBoardSlot ref: SMX_ComputerSystemChassis ref: SMX_MemoryBoardSlot 12-3 Supported indications The following table describes the properties that are common to all of the SMX Memory Provider indications that are implemented for server platforms, where available: Table 12-29 Provider - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 273
the indication Model name of the computer system generating the indication Platform GUID of the computer system generating the indication The following tables describe the SMX Memory Provider indications that are implemented for server platforms where available: Table 12-30 SMX_MemoryIndication - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 274
and replace the memory board and memory modules as necessary. HP_AlertIndication Memory board error 3 (Memory) 1 (Other) Memory B CIM_Indication 5 (Major) CIM_AlertIndication The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 275
necessary." HP_AlertIndication Advanced Memory Protection degraded 3 (Memory) 88 (Loss of Redundancy) Advanced Memory Protection Degraded CIM_Indication 2 (Information) CIM_AlertIndication The Advanced Memory Protection (AMP) system is operating normally in the targeted configuration. If redundancy - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 276
Overview The following profiles are implemented, and the following files are installed by this provider. Table 13-1 Overview Implemented Profiles • HP Blade System Lite Profile 1.0 13-2 Namespaces This provider returns instances in the root/hpq namespace. 13-3 Class implementations The following - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 277
status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 278
InstanceID Caption GroupOperationalStatus Property implementation CIM_ManagedElement A collection of server blade enclosures with group aggregate status Server Blade Enclosure Collection CIM_Collection CIM_SystemSpecificCollection HPQ:HP_BladeEnclosureCollection:001 HP_GroupSystemSpecificCollection - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 279
HP_BladeSystemComponent ref: HP_ComputerSystem (the blade enclosure computer system) ref: HP_ComputerSystem (the blade servers computer system) 13-3-4 SMX_MemberOfBladeEnclosureCollection SMX_MemberOfBladeEnclosureCollection extends the class CIM_MemberOfCollection and associates the enclosure - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 280
describes blade enclosure firmware. The Windows-specific implementation class is HP_BladeEnclosureFW. The following Server Blade Enclosure Firmware HP Server Blade Enclosure Firmware OA CIM_ManagedSystemElement If enclosure name exists: HP BladeSystem c-Class enclosure otherwise: HP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 281
of the content provided in the MajorVersion and MinorVersion properties. Hewlett-Packard 10 (Firmware) HP Server Blade Enclosure Firmware An array in which first element contains the path of the target type/firmware family and the second element is HPQ:OA CIM:SoftwareFamily HP_BladeEnclosureFW 13 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 282
HP_BladeEnclosureInstalledFWIdentity ref: HP_BladeEnclosureCS ref: HP_BladeEnclosureFW 13-3-9 SMX_BladeCSLocation SMX_BladeCSLocation is used to model the server blade location within an enclosure. Table 13-10 Class: SMX_BladeCSLocation Property name Caption Description - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 283
CIM_ManagedElement. Table 13-11 Class: HP_ElementLocation Property name Element PhysicalLocation Property implementation References CIM_ManagedElement References CIM_Location 13-4 Supported indications There are no indications specific to the blade system implementation. Blade System Lite 283 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 284
14 FC HBA 14-1 Overview This provider implements the HP FC HBA Profile which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel CIM_ManagedSystemElement GUID • 0 (Unknown) • 2 (OK-Online) • 6 (Error) • 10 (Stopped) • 11 (In Service) FC - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 285
Offline • Stopped Bypassed • Stopped Diagnostics • Stopped Link down • Error CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) CIM_System SMX_FCHBAComputerSystem Other CIM_ComputerSystem 0 HPQ:GUID GUID 14-3-2 SMX_FCBAFCPort SMX_FCHBAFCPort is used to - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 286
Property implementation • 0 (Unknown) • 2 (OK-Online) • 6 (Error) • 10 (Stopped) • 11 (In Service) • Unknown • OK-Online • Stopped Offline • Stopped Bypassed • Stopped Diagnostics • Stopped Link down • Error CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Applicable) 12 (Not - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 287
Table 14-3 Class: SMX_FCHBAFCPort Property name PortType Speed UsageRestriction LinkTechnology PermanentAddress PortNumber SupportedMaximumTransmissionUnit Property implementation 1 (Other) One of (in Bits per Second): • 0 • 1000000000 • 2000000000 • 10000000000 4 (not restricted) CIM_NetworkPort 4 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 288
Table 14-4 Class: SMX_FCHBAPortController Property name SystemName ControllerType Property implementation Opaque CIM_Controller CIM_PortController 4 (FC) 14-3-4 SMX_FCHBAFCPortStatistics SMX_FCHBAFCPortStatsitics represents statistics for a Fibre Channel port. In the following table - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 289
Table 14-5 Class: SMX_FCHBAFCPortStatistics Property name PrimitiveSeqProtocolErrCount Property implementation HBAAPI_PORTSTATISTICS.PrimitiveSeqProtocolErrCoun t 14-3-5 SMX_FCHBALogicalPortGroup A collection of one or more ports logically grouped for administrative, discovery and topology - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 290
Table 14-7 Class: SMX_FCHBAPhysicalPackage Property name OperationalStatus[] CreationClassName Manufacturer Model OtherIdentifyingInfo SerialNumber Tag Version RemovalConditions Property implementation 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) CIM_PhysicalElement SMX_FCHBAPhysicalPackage - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 291
: where is the port controller instance number for the same adapter Manufacturer File version of the Driver 14-3-9 SMX_FCHBAFirmwareIdentityFW SMX_FCHBA_FirmwareIdentityFW represents adapter firmware associated with the Fibre Channel port controller. Table 14-10 Class - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 292
Table 14-10 Class: SMX_FCHBAFirmwareIdentityFW Property name ClassificationDescriptions Classifications InstanceID Manufacturer SerialNumber VersionString Property implementation CIM_SoftwareIdentity FC HBA Firmware 10 (firmware) HPQ:WWN: where is the port controller - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 293
GroupOperationalStatus[0] GroupStatusDescriptions[0] Property implementation CIM_ManagedElement FC HBA Consolidated Status Consolidated status for HP FC HBAs FC HBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection Opaque HP_GroupSystemSpecificCollection • 0 (Unknown) • 1 (Other - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 294
SMX_FCHBA_ComputerSystemFCPort is used to represent an association between SMX_FCHBA_ComputerSystem and HPFCHBA_FCPort. Table 14-13 Class: SMX_FCHBA_ComputerSystemFCPort Property name GroupComponent PartComponent Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemFCPort - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 295
Table 14-15 Class: SMX_FCHBAComputerSystemLogicalPortGroup Property name Dependent Property implementation ref:SMX_FCHBALogicalPortGroup 14-3-15 SMX_FCHBAComputerSystemSoftwareIdentityDrv SMX_FCHBA_ComputerSystemSoftwareIdentityDrv is used to represent an association between - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 296
Table 14-18 Class: SMX_FCHBA_FCPortLogicalPortGroup Property name Collection Member Property implementation CIM_MemberOfCollection SMX_FCHBAFCPortLogicalPortGroup ref:SMX_FCHBALogicalPortGroup ref:SMX_FCHBAFCPort 14-3-18 SMX_FCHBAPortControllerFCPort SMX_FCHBAPortControllerFCPort is used to - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 297
SMX_FCHBASoftwareIdentityDrvPortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBASoftwareIdentityDrv. Table 14-21 Class: SMX_FCHBASoftwareIdentityDrvPortController Property name Antecedent Dependent Property implementation CIM_Dependency - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 298
14-3-23 SMX_FCHBAProductPhysicalComponent SMX_FCHBAProductPhysicalComponent is used to represent an association between SMX_FCHBA_Product and SMX_FCHBAPhysicalPackage. Table 14-24 Class:SMX_FCHBAProductPhysicalComponent Property name GroupComponent PartComponent Property implementation - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 299
Table 14-26 Class: SMX_FCHBAGroupHostedCollection Property name Antecedent Dependent Property implementation SMX_FCHBA_GroupHostedCollection ref:SMX_ComputerSystem ref:SMX_FCHBAGroupSystemSpecificCollection 14-3-26 SMX_FCHBAFCPortGroupSystemSpecific SMX_FCHBAFCPortGroupSystemSpecific is used to - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 300
implementation CIM_ManagedElement ProductName CIM_ManagedSystemElement 0 (Unknown) 2 (OK-Online) 6 (Error) 10 (Stopped) 11 (In Service) CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) CIM_LogicalDevice SMX_FCHBASCSIProtocolController PortWWN Opaque - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 301
Table 14-30 Class: SMX_FCHBASCSIProtocolController Property name MaxUnitsControlled Property implementation 255 CIM_SCSIProtocolController 14-3-30 SMX_FCHBASCSIProtocolEndpoint SMX_FCHBASCSIProtocolEndpoint represents SCSI protocol running through a port. Table 14-31 Class: - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 302
Table 14-32 Class: SMX_FCHBAComputerSystemSCSIProtocolController Property name GroupComponent PartComponent Property implementation CIM_SystemDevice SMX_FCHBAComputerSystemSCSIProtocolController ref:SMX_FCHBAComputerSystem ref:SMX_FCHBASCSIProtocolController 14-3-32 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 303
Table 14-35 Class: SMX_ FCHBASystremServiceAccessPoint Property name Antecendent Dependent Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedAccessPoint SMX_FCHBASysteServiceAccessPoint ref:SMX_FCHBAComputerSystem ref:SMX_ FCHBASCSIProtocolEndpoint 14-3-35 - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 304
Class implementations The following classes are implemented for HP server platforms where available. The following classes describe " Examples: • Remote Insight Board Lights Out Edition II (RILOE-II) • Integrated Lights Out (iLO) (Active) • Integrated Lights Out 2 (ILO2) (Inactive) Management - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 305
and is the name of the MP product (same as the product name in property ElementName) For example, Active HP Management Processor - Integrated Lights Out (iLO) Product name of the management processor. For example: Product name of the management processor in format: " - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 306
OperationalStatus mapping table in HP Management Processor (MP) Lite Profile for specific descriptions of when each value contribute negatively to overall system status. An MP is disabled only if the user has manually disabled it through the MP's RBSU settings; this is seen as a "normal" condition - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 307
a state of 5 (OK) so as not to contribute negatively to overall system status. An MP is disabled only if the user has manually disabled it via the MP's RBSU settings; this is seen as a "normal" condition. CIM_LogicalElement CIM_EnabledLogicalElement • 2 (Enabled) for active MP • 3 (Disabled) for - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 308
Integrated Lights Out Controller (iLO)) • 4 (Embedded Integrated Lights Out Controller 2 (iLO 2)) • 5 (Embedded Integrity Management Processor) • 6 (Embedded Integrity Integrated Lights Out Controller (iLO)) • 7 (Embedded Integrity Integrated Lights the protocols supported by the management - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 309
the MP firmware for example: Management Processor Firmware HP Management Processor Firmware The target type/firmware family For example: • RI7 for iLO2 CIM_ManagedSystemElement Product name of the management processor. Examples: • Integrated Lights Out 2 (ILO2) • 2 (OK) • 6 (Error) when MP software - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 310
Hewlett-Packard 10 (Firmware) HP Management Processor Firmware An array in which first element contains the path of the target type/firmware family and the the target type/firmware family: Examples: • "HPQ:RI7" for ProLiant iLO 2 • "HPQ:iLO2" for Integrity iLO 2 • "HPQ:MP" for Integrity MP CIM - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 311
GroupStatusDescription Property implementation Management Processor Collection Describes the group operational status of the management processor collection (refer to HP Management Processor (MP) Lite Profile). The group operational status represents the 'worst-of' algorithm for all individual MP - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 312
15-3-5 SMX_MPComponentCS SMX_MPComponentCS implements the class HP_MPComponentCS, and associates a management processor subsystem to the scoping computer system that contains it. The following properties are implemented. Table 15-6 Class: SMX_MPComponentCS Property name GroupComponent - HP ML350 | HP Insight Management WBEM Providers for HP integrated VMware ESXi Da - Page 313
name System InstalledSoftware Property implementation CIM_InstalledSoftwareIdentity HP_MPInstalledFirmwareIdentity ref: HP_ManagementProcessor ref: HP_MPFirmware 15-4 Supported indications There are no indications specific to the management processor implementation. Management Processor Lite 313
HP Insight Management WBEM Providers for
HP integrated VMware ESXi
Data Sheet
Part number 574748-002
Second Edition December 2009