HP ML350 HP ProLiant Servers Troubleshooting Guide - Page 141

Slot X Drive Array-Optional SIMM Failure Detected, lot X Drive Array - Array Accelerator Memory Size

Page 141 highlights

1725-Slot X Drive Array-Optional SIMM Failure Detected Audible Beeps: None Possible Cause: SIMM has been automatically disabled due to memory errors or unsupported SIMM type installed. Action: Replace the SIMM memory module on the indicated controller. 1726-Slot X Drive Array - Array Accelerator Memory Size Change Detected. - ... ...Array Accelerator configuration has automatically been updated. Audible Beeps: None Possible Cause: The array accelerator configuration has been updated automatically due to replacement of the array accelerator (or controller) with one having different cache memory size. Action: Run the ACU ("Array Configuration Utility" on page 67) to change the default cache read/write allocation ratio. 1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected... ...If more than 32 logical drives, this message will be followed by: "Auto-configuration failed: Too many logical drives." Audible Beeps: None Possible Cause: The controller has detected an additional array of drives that was connected when the power was off. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32. Additional logical drives will not be added to the configuration. Action: No action is required. 1729-Slot 1 Drive Array - Performance Optimization Scan In Progress... ...RAID 4/5/ADG performance may be higher after completion. Audible Beeps: None Possible Cause: RAID 4/5/ADG parity drive(s) are being initialized. Performance of the controller improves after the parity data has been initialized by ARM (an automatic process that runs in the background on the controller). Action: No action is required. 1732-Slot z Drive Array - Array Accelerator Battery Pack Missing... ...Array Accelerator Posted-Write Cache is permanently disabled. Array Accelerator will be reenabled when additional battery packs are installed. Audible Beeps: None Possible Cause: Battery packs are detached from the controller or have failed. Action: Check the battery pack to be sure the connection is secure. If the condition persists, then install a replacement battery pack. Error messages 141

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

1725-Slot X Drive Array-Optional SIMM Failure Detected
Audible Beeps
: None
Possible Cause
: SIMM
installed.
has been automatically disabled due to memory errors or unsupported SIMM type
1726-S
hange Detected. - ...
or configuration has been updated automatically due to replacement
r (or controller) with one having different cache memory size.
to change the default cache read/write
1727-Slot X Drive Array - New Logical Drive(s) Attachment Detected...
: Too many logical
drives.”
use
: The controller has detected an additional array of drives that was connected when the
1729-Slot 1 Drive Array - Performance Optimization Scan In Progress...
...RAID 4
Beeps
: None
drive(s) are being initialized. Performance of the controller
matic process that runs in the
background on the controller).
Pack Missing...
lerator will be reenabled when
packs are detached from the controller or have failed.
persists, then install a
Action
: Replace the SIMM memory module on the indicated controller.
lot X Drive Array - Array Accelerator Memory Size C
...Array Accelerator configuration has automatically been updated.
Audible Beeps
: None
Possible Cause
: The array accelerat
of the array accelerato
Action
: Run the ACU ("
Array Configuration Utility
" on page
67
)
allocation ratio.
...If more than 32 logical drives, this message will be followed by: “Auto-configuration failed
Audible Beeps
: None
Possible Ca
power was off. The logical drive configuration information has been updated to add the new logical
drives. The maximum number of logical drives supported is 32. Additional logical drives will not be
added to the configuration.
Action
: No action is required.
/5/ADG performance may be higher after completion.
Audible
Possible Cause
: RAID 4/5/ADG parity
improves after the parity data has been initialized by ARM (an auto
Action
: No action is required.
1732-Slot z Drive Array - Array Accelerator Battery
...Array Accelerator Posted-Write Cache is permanently disabled. Array Acce
additional battery packs are installed.
Audible Beeps
: None
Possible Cause
: Battery
Action
: Check the battery pack to be sure the connection is secure. If the condition
replacement battery pack.
Error messages 141