HP MSA2312i HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00
HP MSA2312i Manual
View all HP MSA2312i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP MSA2312i manual content summary:
- HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 1
HP 2000i G2 Modular Smart Array User Guide Part number: 481598-005 First edition: January 2013 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 3
stability 13 HP technical support 13 Customer self repair 13 Product warranties 13 Subscription service 13 HP web sites 13 Documentation feedback 14 1 Overview 15 Features and benefits 15 2 Components 17 Front panel components 17 2312i G2 17 2324i G2 17 Disk drive bay numbers 18 Rear - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 4
off 33 Updating firmware 33 Selecting an appropriate time to perform the online upgrade 33 6 LED descriptions 35 Front panel LEDs 35 Disk drive LEDs 36 Rear panel LEDs 37 2312i G2 and 2324i G2 37 MSA2000 3.5" 12-drive enclosure 39 MSA70 2.5" 25-drive enclosure 39 Power supply LEDs 40 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 5
notice 66 Korean notices 66 Safety 66 Battery replacement notice 66 Taiwan battery recycling notice 67 Power cords 67 Japanese power cord notice 67 Electrostatic discharge 67 Preventing electrostatic damage 67 Grounding methods 68 Index 69 HP 2000i G2 Modular Smart Array User Guide 5 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 6
6 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 7
between a dual-controller enclosure and one MSA70 drive enclosure 24 5 Cabling connections between a dual-controller enclosure and three MSA70 drive enclosures 25 6 Cabling connections between a dual-controller enclosure and mixed drive enclosures 26 HP 2000i G2 Modular Smart Array User Guide 7 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 8
8 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 9
descriptions 55 9 Controller module temperature sensors 55 10 Power supply temperature sensors 56 11 Voltage sensor descriptions 56 12 Rackmount enclosure dimensions 59 13 Rackmount enclosure weights 59 14 Operating environmental specifications 59 HP 2000i G2 Modular Smart Array User Guide 9 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 10
10 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 11
HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide • Online help for HP StorageWorks Storage Management Utility (SMU) and Command Line Interface (CLI) These and other HP documents can be found on the HP documents web site: http://www.hp.com/support/ HP 2000i G2 Modular Smart Array User - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 12
at the command line WARNING! Indicates that failure to follow directions could result in bodily harm or death. CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 13
this service provides you with e-mail updates on the latest product enhancements, newest versions of drivers, and firmware documentation updates as well as instant access to numerous other product resources. • After signing up, you can quickly locate your products by selecting Business support and - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 14
www.hp.com/go/msa • http://www.hp.com/service_locator • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.docs.hp.com Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to storagedocs.feedback@hp - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 15
list of supported servers, operating systems, disk drives, and options. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be on the right. HP 2000i G2 Modular Smart Array User Guide 15 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 16
16 Overview - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 17
ID LED 2 Disk drive Online/Activity LED 3 Disk drive Fault/UID LED Right ear MSA2000 4 Unit Identification (UID) LED 5 Fault ID LED 6 Heartbeat LED 4 5 6 Right ear MSA2000 4 Unit Identification (UID) LED 5 Fault ID LED 6 Heartbeat LED 4 5 6 HP 2000i G2 Modular Smart Array User Guide 17 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 18
G2 and 2324i G2 12 3 45 6 7 LINK iSCSI 1 ACT LINK iSCSI 2 ACT LINK iSCSI 1 ACT LINK iSCSI 2 ACT 9 - 8 12 1 AC Power supplies 2 AC Power switches 3 Host ports 4 CLI port 5 Network port 18 Components 6 Service port (used by service personnel only) 7 Expansion port 8 Optional iSCSI controller - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 19
Smart Array Enclosure user guide located on the MSA2000 Software Support/Documentation CD shipped with your product or at http://hp.com/support/manuals. Cache To enable faster data access from disk storage, the following two types of caching are performed: • Posted-write caching. The controller - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 20
controller to the replacement controller using a procedure outlined in the HP StorageWorks 2312i/2324i G2 controller replacement instructions, shipped with the replacement controller a power failure. Unwritten data in CompactFlash memory is automatically committed to disk media when power is - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 21
StorageWorks 2000 Modular Smart Array Software Support/Documentation CD shipped with your product. NOTE: For information on NEBS Level-3 compliant carrier-grade enclosures, see http://www.hp.com/products1/servers/carrier_grade/products/cgblades/enclosure. HP 2000i G2 Modular Smart Array User Guide - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 22
the MSA70, including detailed steps to upgrade the firmware, see the HP StorageWorks 70 Modular Smart Array Enclosure User Guide located on the MSA2000 Software Support/Documentation CD shipped with your product, or at http://hp.com/support/manuals. Connecting controller and mixed-connect 3.5" and - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 23
mini-SAS to mini-SAS connections, respectively. IMPORTANT: For a complete list of supported cables, cable part numbers, available options, and cabling illustrations, see the MSA2000 G2 QuickSpecs at http://www.hp.com/go/msa. NOTE: For clarity, the schematic illustrations of the controllers shown - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 24
B 1B Out In 2A Out 2B In Out 3A In Out 3B In Out In 4A Out 4B In Figure 3 Cabling connections between a dual-controller enclosure and three MSA2000 3.5" 12-drive enclosures Controller A 0A Controller B 0B 1A In Out 1B In Out Figure 4 Cabling connections between a dual - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 25
Controller A 0A Controller B 0B 1A In Out 1B In Out 2A In Out 2B In Out 3A In Out 3B In Out Figure 5 Cabling connections between a dual-controller enclosure and three MSA70 drive enclosures HP 2000i G2 Modular Smart Array User Guide 25 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 26
connections between a dual-controller enclosure and mixed drive enclosures. TIP: For comprehensive configuration options and associated illustrations, see the HP StorageWorks 2000 G2 Modular Smart Array Cable Configuration Guide. Testing enclosure connections 1. Press the power switches at the back - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 27
with configuring your MSA2000 G2 product, also see the MSA2000 Software Support/Documentation CD shipped with your product. Setting management port IP addresses using DHCP 1. Look in the DHCP server's pool of leased addresses for two IP addresses assigned to "HP StorageWorks MSA Storage." 2. Use the - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 28
provided micro-DB9 serial cable to connect controller A to a serial port on a host computer. iSCSI 1 iSCSI 2 CLI CLI Service DIRTY CACHE SAS 1 ACTIVITY LINK Connect serial cable to CLI port on controller faceplate Your package contents include a micro-DB9-to-DB9 serial cable. If necessary - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 29
Management Controller, communication with it is temporarily lost until it successfully restarts. Type the following command to restart the management controller on both controllers: restart mc both 10. When you are done using the CLI, exit the emulator. HP 2000i G2 Modular Smart Array User Guide 29 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 30
30 Installing the enclosures - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 31
resides on the MSA2000 G2 product site at http://hp.com/support/manuals. Locate the HP StorageWorks MSA2000 G2 Cable Configuration Guide, which is updated to describe newly-supported direct connect, switch-connect, and expansion configuration options for the MSA2000 G2. Any number or combination of - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 32
Array use Unified LUN Presentation (ULP) - a controller firmware feature enabling hosts to access mapped volumes via host ports - without the need for internal or external switches. Connecting direct attach configurations The 2312i G2 and 2324i G2 support each controller. 2. Connect the other end of - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 33
Revision; expansion module B's firmware version is shown as EMP B Revision. For software and firmware updates, including update instructions, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support. Selecting an appropriate time to perform the online upgrade To - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 34
For software and firmware updates, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support. For detailed steps on updating the firmware, see the reference guide or the CLI reference guide. For information on logging into SMU, see Configuring a system for the - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 35
exists. The event has been identified, but the problem needs attention. Off - No fault condition exists. Green - The enclosure is powered on with at least one power supply operating normally. Off - Both power supplies are off; the system is powered off. HP 2000i G2 Modular Smart Array User Guide 35 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 36
Fault/UID (amber/blue) 2 Online/Activity (green) Table 6 Disk drive LED combinations Online/Activity (green) Fault/UID (amber/blue drive has been selected by a management application (SMU). Blue; solid The controller is driving I/O to the drive, and it has been selected by a management application - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 37
the Clearing disk metadata topic in the reference guide or SMU online help. Rear panel LEDs 2312i G2 and 2324i G2 1 4 5 67 1 LINK iSCSI 1 ACT LINK iSCSI 2 ACT LINK iSCSI 1 ACT LINK iSCSI 2 ACT 2 38 9 : ; w LED Description Definition 1 Power supply LEDs See Power supply LEDs on page - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 38
-falsely indicating that the controller can communicate with the host. Though a link exists between the host and the chip on the controller, the controller is not communicating with the chip. To reset the LED, the controller must be properly power-cycled (see Powering on/powering off on page 33 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 39
the MSA70, including detailed steps to upgrade the firmware, see the HP StorageWorks 70 Modular Smart Array Enclosure User Guide located on the MSA2000 G2 Software Support/Documentation CD shipped with your product, or at http://hp.com/support/manuals. HP 2000i G2 Modular Smart Array User Guide 39 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 40
connecting the power supplies to separate circuits. 1 1 2 2 AC model DC model LED Description Definition 1 Input Source Power good Green - Power is on and input voltage is normal. Off - Power is off or input voltage is below the minimum threshold. 2 DC Voltage/Fan Fault/Service Required - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 41
. For better performance, use Firefox or Internet Explorer 7 or later. NOTE: Check the QuickSpecs for currently supported browsers. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA SAN Arrays, and then select your product. The link for QuickSpecs will be - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 42
that is automatically updated to show current can be sorted by a specific column. To do so, resets after each action you perform. One minute before auto-signout, you are prompted to continue using SMU. The timer does not appear if the current user SMU's reference guide and help time manually or - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 43
Address. Optional. If the system should retrieve time values from a specific NTP server, enter the address of an NTP server. If no IP server address is set, the system listens for time messages sent by an NTP server in broadcast mode. 3. Click Apply. HP 2000i G2 Modular Smart Array User Guide 43 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 44
• Password for default users. • Network-port configuration. • System-management services, including the following out-of-band and in-band services: • Web browser interface, known as SMU (Storage Management Utility). • Command Line Interface (CLI). • Storage Management Initiative Specification (SMIS - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 45
automatically ends when the user's automatic sign-out time expires. If the preference is set to Never, the session ends after 9999 minutes. 1. Click Sign Out in the upper right-hand corner. The Sign Out Request dialog is displayed. 2. Click Sign Out. HP 2000i G2 Modular Smart Array User Guide 45 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 46
46 Configuring a system for the first time - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 47
module, controller module, or power supply? By a virtual disk if a user changes Perform a rescan. • Power cycle the system. • Make sure the power cord is properly connected, and check the power source that it is connected to. • Check the event log for errors. HP 2000i G2 Modular Smart Array User Guide - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 48
error • Cache flush error • Cache self-refresh error Actions No action required. • Restart this controller from the other controller using SMU or the CLI. • Remove the controller and reinsert it. • Contact an authorized service provider for assistance. • Replace the controller. 48 Troubleshooting - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 49
cable. Replace cable powered on and operational. • In SMU, review event logs for indicators of a specific fault in a host data path component. • Contact an authorized service provider for assistance. • See Isolating a host-side connection fault on page 53. HP 2000i G2 Modular Smart Array User Guide - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 50
fault is caused by a defective cable. Replace cable if necessary. • In SMU, review event logs for indicators of a specific fault in a host data path component. • Contact an authorized service provider for assistance. • See Isolating a controller module expansion port connection fault on page 54. Is - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 51
regarding the fault. • Isolate the fault. • Contact an authorized service provider for assistance. • Replace if necessary. • If installing an I/O module FRU, try removing and reinstalling the new I/O module, and check the event log for errors. HP 2000i G2 Modular Smart Array User Guide 51 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 52
disks. If the problem persists, replace the controller. Transporting Cache To preserve the existing data stored in the CompactFlash, you must transport the CompactFlash from the failed controller to a replacement controller using a procedure outlined in the HP StorageWorks 2312i/2324i G2 controller - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 53
port. Is the host link status LED on? • No - The controller module's port has failed. Replace the controller module. • Yes - Monitor the connection for a period of time. It may be an intermittent problem, which can occur with damaged cables and HBAs. HP 2000i G2 Modular Smart Array User Guide 53 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 54
old module in place until you have the replacement or use a blank module to fill the slot. Leaving a slot open negatively affects the airflow and can cause the enclosure to overheat. 4. Try replacing each power supply one at a time. 5. Replace the controller modules one at a time. 54 Troubleshooting - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 55
controller module and expansion module, the enclosure management processor (EMP) monitors the status of these sensors to perform SCSI enclosure services (SES) functions. The following sections describe each element and its sensors. Power supply None HP 2000i G2 Modular Smart Array User Guide 55 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 56
Table 9 Controller module temperature sensors (continued) power supply. Table 11 Voltage sensor descriptions Sensor Event/Fault LED condition Power supply 1 voltage, 12V Power supply 1 voltage, 5V Power supply 1 voltage, 3.3V < 11.00V > 13.00V < 4.00V > 6.00V < 3.00V > 3.80V 56 Troubleshooting - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 57
an earth ground connection to the DC power source. Grounding must comply with local, national, or other applicable government codes and regulations. • Power circuits and associated circuit breakers must provide sufficient power and overload protection. HP 2000i G2 Modular Smart Array User Guide 57 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 58
page 59 for detailed size and weight specifications. • The weight of an enclosure depends on the number and type of modules installed. • serial port connection is recommended for the initial installation and configuration of a controller enclosure. After you configure one or both of the controller - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 59
cables • To back of power supply handle 3.5 inches (8.9 cm) 17.55 inches (44.58 cm) 21.3 inches (54.0 cm) 23.7 inches (60.2 cm) .Table 13 Rackmount enclosure weights Specifications 2312i G2 Modular Smart Array • SAS drives • SATA drives 2324i G2 Modular Smart Array • SAS drives • SATA drives - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 60
required, use a separate power source for each module. The AC power supply unit in each power and cooling module is auto power and cooling modules use standard industrial wiring with line-to-neutral or line-to-line power connections. Power cord requirements Each enclosure is shipped with two AC power - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 61
life expectancy of the device. To prevent electrostatic damage: • Avoid hand contact by transporting and storing products Use conductive field service tools. • Use a portable field service kit with a product installation, contact an authorized reseller. HP 2000i G2 Modular Smart Array User Guide 61 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 62
62 Electrostatic discharge - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 63
additional operating instructions for the user. The rating product, visit http://www.hp.com. For questions regarding this FCC declaration, contact us by mail or telephone: • Hewlett-Packard Company P.O. Box 692000, Mailstop 510101 Houston, Texas 77269-2000 HP 2000i G2 Modular Smart Array User Guide - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 64
user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP authorized service technicians to repair the laser device. Certification and classification information This product contains - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 65
: This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g., Bluetooth). Certificates can be obtained from http://www.hp.com/go/certificates. Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany HP 2000i G2 Modular Smart Array User Guide 65 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 66
is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized service provider. 66 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 67
. This type of damage may reduce the life expectancy of the device. Preventing electrostatic damage To prevent electrostatic damage, observe the following precautions: • Avoid hand contact by transporting and storing products in static-safe containers. HP 2000i G2 Modular Smart Array User Guide 67 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 68
field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part. NOTE: For more information on static electricity, or assistance with product installation, contact your HP authorized - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 69
requirements 59 troubleshooting 47 ESD (electrostatic discharge) prevention measures 67 storing products 67 transporting products 67 Ethernet cables requirements 32 European Union, regulatory compliance notice 65 expansion port LED troubleshooting 54 HP 2000i G2 Modular Smart Array User Guide 69 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 70
35 power supply 37 rear panel 37 Unit Identification (UID) 35 Unit Locator 37 using to diagnose fault conditions 48 lithium battery 66 local management host requirement 58 M MPIO DSM, obtaining 31 MSA2000 3.5 12-drive enclosure LEDs 39 ports 19 MSA2000 Family SCSI Enclosure Services (SES) driver 31 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 71
58 version information checking 33 vibration operating range 59 virtual disks viewing status 45 voltage compliance rating 67 volumes verifying 45 W warnings lasers, radiation 64 rack stability 13 voltage and temperature 54 web sites HP documentation 11 HP 2000i G2 Modular Smart Array User Guide 71 - HP MSA2312i | HP StorageWorks 2000i G2 Modular Smart Array user guide (481598-00 - Page 72
HP storage 14 HP Subscriber's choice 13 web-browser configuration 41 work mat, static-dissipating 68 wrist straps specifications 68 using 68 72
HP 2000i G2 Modular Smart Array
User Guide
Part number: 481598-005
First edition: January 2013