About this document
This document details procedures for replacing a failed DC power
supply in an HP StorageWorks 2000 Family Modular Smart Array.
Before you begin
CAUTION:
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection:
Keep the replacement component in the ESD bag until needed
Wear an ESD wrist strap grounded to an unpainted surface
of the chassis.
If an ESD wrist strap is unavailable, touch an unpainted surface
of the chassis before handling the component.
Never touch connector pins.
Verifying component failure
Check the DC Voltage/Fan Fault/Service Required (bottom) LED:
Amber = Fault condition
Disconnecting a DC power cable
IMPORTANT:
Use only the DC power cables provided with your product.
1.
Verify that the main breaker to the rack is shut off prior to
disconnecting any DC connections.
2.
Verify that all enclosure power switches are off.
3.
Loosen the cable-locking screws attaching the D-shell connector to
the power supply.
4.
Disconnect the power cable from the power supply.
5.
Turn on the main breaker to the rack.
Removing a power supply
1.
Turn the thumbscrew until it is disengaged from the module.
2.
Rotate the latch downward to disconnect the internal connector,
and slide the module out.