HP NetServer LT 6000r HP Netserver LH 6000 NetRAID-3Si Config Guide for Windo

HP NetServer LT 6000r Manual

HP NetServer LT 6000r manual content summary:

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

1
HP NetServer LH6000
with
NetRAID-3Si (HP Rack Storage/12)
Cluster Configuration Guide
4 October 2000
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LH6000 configurations with HP Rack Storage/12s and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide extended
availability.
The specific configuration certified and supported by both Hewlett-Packard and Microsoft is
defined, as are other guidelines to assist you in configuring your clustered NetServers.
This guide is prescriptive;
it describes the configurations supported by HP.
Any deviance to these configurations can result in an
inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and therefore will not
be supported by HP.
What's Defined in a Racked Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH6000
Each node must be the same model SPU, but may have different clock
speeds, main memory sizes, cache sizes, and number of CPUs.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage /12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.02 or later