HP NetServer LT 6000r HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide
HP NetServer LT 6000r Manual
View all HP NetServer LT 6000r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP NetServer LT 6000r manual content summary:
- HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 1
extended availability. The specific configuration certified and supported by both Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers. This guide is prescriptive; it describes the configurations supported by HP. Any deviance to - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 2
Operating system Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LH4 400, 450, 500, 550, 700 - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 3
/12FC.) 4.64-00 or later 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 4
same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH4, one HP Rack Storage/12FC and two HP Rack Storage/12s. Only these cabling configurations and cables are supported. 4 - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 5
P4 LEGEND Heavy (blue) lines are fibre channel Optical or Copper cables. See inside this guide for specifications. Dashed (green) lines are offset SCSI cables. See inside this guide for specifications. HP Microsoft Cluster using HP Rack Storage/12FC and Rack Storage/12 and 6 Port Fibre Channel Hub 5 - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 6
Power Cabling to Separate Power Circuits 6 - HP NetServer LT 6000r | HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide - Page 7
April 2000 8 February 2000 1 December 1999 Revised intro. Changed boot spec and added boot priority. Added ultra3 drives. Added support for 700 MHz. Added support fot NetRAID-1Si as a local storage controller. Corrected discrepancies in the text and installation diagrams for the Shared storage PCI
1
HP NetServer LH4
with
HP Rack Storage/12FC & HP Rack Storage/12
Cluster Configuration Guide
7 September 2000
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LH4 configurations using the HP Rack Storage/12FC and
Microsoft Cluster Server and one or two HP Rack Storage/12’s.
These configurations minimize single points
of failure (SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your clustered
NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance, hidden
SPOFs, etc., and therefore will not be supported by HP.
What’s Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH4
Each node must be the same model SPU, but may have different clock
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes
2
Shared Storage
HP Rack Storage/12FC with two FCArray Cards, HP disks, and using a
HP D8602A HBA in each server.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.16.05 or later
(For 700 MHz servers, use L.18.04.05 or later)