HP NetServer LT 6000r HP Netserver LH 3 NetRAID-3Si Config Guide for Windows
HP NetServer LT 6000r Manual
View all HP NetServer LT 6000r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP NetServer LT 6000r manual content summary:
- HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 1
defines the supported HP NetServer LH3 configurations with HP Rack Storage/12s and /8s and Microsoft Cluster Server. These configurations minimize single points of failure (SPOF), provide maximum availability, and have been certified by Hewlett-Packard and Microsoft. This guide is prescriptive - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 2
Products List. May not use Embedded RAID or NeRAID-3Si for internal storage or external with a Rack Storage/12. HP only Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 3
part number and suffix). Different size or speed disks are not allowed in the same RAID array. Any combination of disk models is allowed on a SCSI channel and in a cluster. Number and mix of cabinets Rack Storage/12: Model Disk drives speed. HP D5957A Cluster Adapter (2 required per HP Rack Storage - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 4
a crossover cable. It may not be used for client communication. HP D5013A/B (10/100TX PCI) 3.00.06.004 or later 1 P1 Client LAN Any LAN Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver If the NIC used is the same as the Intra - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 5
Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH 3 and HP Rack Storage/12s and /8s. Only these cabling configurations and cables are supported. HP Microsoft Cluster using the HP Rack Storage/12 5 - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 6
HP Microsoft Cluster using the HP Rack Storage/8 6 - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 7
HP Microsoft Cluster Server Power Cabling (Rack Storage/12 shown. Rack Storage/8 is the same except for the rear view) 7 - HP NetServer LT 6000r | HP Netserver LH 3 NetRAID-3Si Config Guide for Windows - Page 8
14 July 1999 Revised the No. of Power Supplies specification from "2 - 3" to "2 required, 3 for redundancy." Revised the ac power cabling diagram to depict applying HP NetServer power from separate power circuits. 25 May 1999 Added two 18.2 GB disk drives for use with the Rack Storage/12. These
HP NetServer LH 3
with
NetRAID-3Si (HP Rack Storage/12 and /8)
Cluster Configuration Guide
29 March 2000
(see Version History at the end of this document)
Introduction
This document defines the supported HP NetServer LH3 configurations with HP Rack Storage/12s and /8s
and Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF), provide
maximum availability, and have been certified by Hewlett-Packard and Microsoft.
This guide is
prescriptive; it describes the configurations supported by HP.
Any deviance to these configurations can
result in an inoperative cluster or an operating cluster with degraded performance, hidden SPOFs, etc., and
therefore will not be supported by HP.
What’s Defined in Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 3
Each node must be the same model SPU, but may have different size main
memory, cache, and CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage/12 or Rack Storage/8 with HP NetRAID-3Si controller and
HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power supply
(UPS) using any power conditioner or UPS.