HP NetServer LT 6000r HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind
HP NetServer LT 6000r Manual
View all HP NetServer LT 6000r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP NetServer LT 6000r manual content summary:
- HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 1
HP NetServer LXr 8500 with NetRAID-3Si (HP Rack Storage/12) Windows 2000 Advanced Server Cluster Configuration Guide 1 February 2001 (see Versions at the end of this document) Introduction This document defines the configuration that Hewlett-Packard supports for the HP NetServer LXr 8500, HP Rack - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 2
2000 Adv. Server CD or later. For NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any HP NetRAID-3Si Adapter - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 3
Disk drives: Cables LANs LAN connection NIC: Model 0, 1, 2 1, 5, 10, 50 1 per RAID array 8 maximum per NetRAID-3Si HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 4
supported driver NOTE If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LXr 8500 and HP - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 5
for connecting local storage drives. 3. Cables between the servers and shared storage cabinets can be any HP LVD SCSI (offset) cable up to 10 meters. See "Cables" for Rack Storage/12 in the guide for a list of cables that can be used. NetRAID-3Si 02 1 HP Microsoft Cluster using HP Rack Storage/12 - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 6
Power Cabling to Separate Power Circuits 6 - HP NetServer LT 6000r | HP Netserver LXr 8500 NetRAID-3Si Config Guide for Wind - Page 7
Versions 1 February 2001 7 November 2000 Added D6025C. Initial release. 7
1
HP NetServer LXr 8500
with
NetRAID-3Si (HP Rack Storage/12)
Windows 2000 Advanced Server
Cluster Configuration Guide
1 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configuration that Hewlett-Packard supports for the HP NetServer LXr 8500, HP
Rack Storage/12 and Microsoft Cluster Server.
These configurations minimize single points of failure
(SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LXr 8500
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.