HP NetServer LT 6000r HP Netserver LT6000r NetRAID-3Si Config Guide for Windo
HP NetServer LT 6000r Manual
View all HP NetServer LT 6000r manuals
Add to My Manuals
Save this manual to your list of manuals |
HP NetServer LT 6000r manual content summary:
- HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 1
Storage/12 Windows 2000 Advanced Server Cluster Configuration Guide 6 September 2000 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12 and Microsoft Cluster Server. These configurations minimize - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 2
.sys from Windows 2000 Adv. Server CD or later. For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 3
SCSI cards for each cabinet 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 4
LAN NIC must use the same driver as the Intra-cluster NIC. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LT 6000r and HP Rack Storage/12. Only these cabling configurations and these cables are supported. 4 - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 5
HP Microsoft Cluster Server with Rack Storage/12 5 - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 6
Bu tt on Button Power Cabling to Separate Power Circuits 6 - HP NetServer LT 6000r | HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 7
Versions 6 September 2000 Initial release. 7
1
HP NetServer LT 6000r
with
HP Rack Storage/12
Windows 2000 Advanced Server
Cluster Configuration Guide
6 September 2000
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LT 6000r configurations with HP Rack Storage/12 and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Racked Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LT 6000r
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks. See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable. See
Intra-cluster LAN