HP P6000 HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme
HP P6000 Manual
View all HP P6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP P6000 manual content summary:
- HP P6000 | HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme - Page 1
or iSCSI/FCoE Controller Replacement Instructions About this document For the latest documentation, go to http://www.hp.com/support/ manuals, and select your product. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth - HP P6000 | HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme - Page 2
with the iSCSI or iSCSI/FCoE module, see the HP P6300/P6500 Enterprise Virtual Array User Guide. To obtain this guide, go to http:// www.hp.com/support/manuals, click Disk Storage Systems in the storage section, and select your model under P6000/EVA Disk Arrays. • Check the controller status LEDs as - HP P6000 | HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme - Page 3
/FCoE module (using the module CLI): 1. In HP P6000 Command View: a. In the Navigation pane, select Hardware > Controller Enclosure, and then Controller 01 or 02 (the controller being replaced). b. On the Initialized Storage System Properties window, select Shut down, and then select Halt. 2. In - HP P6000 | HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme - Page 4
in soft diagnostic errors being reported. Figure 6 Removing a DIMM power up automatically. Tighten the controller latch thumbscrew. Installing a controller 1. Press each DIMM from the removed controller into the same DIMM socket on the replacement controller (1, Figure 7). Figure 7 Installing - HP P6000 | HP P6300/P6500 EVA iSCSI or iSCSI/FCoE Controller Enclosure Replaceme - Page 5
iSCSI/FCoE module using HP P6000 Command View. In the Navigation pane, select Hardware > iSCSI Devices, and then iSCSI Controller 01 or 02. If necessary, upgrade the iSCSI or iSCSI/FCoE module firmware. See the HP P6300/P6500 Enterprise Virtual Array Installation Guide. e. Select Set Options again
HP P6300/P6500 EVA iSCSI or
iSCSI/FCoE Controller
Replacement Instructions
© Copyright 2011 Hewlett-Packard Development Company, L.P.
First edition: May 2011
The information in this document is subject to change without notice.
Printed in Puerto Rico
www.hp.com
*593089-001*
About this document
For the latest documentation, go to
h
t
tp://w
w
w
.hp
.co
m/su
ppo
r
t/
man
uals
, and select your product.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.
WARRANTY STATEMENT: To obtain a copy of the warranty for this
product, see the warranty information website:
h
t
tp://w
w
w
.hp
.co
m/go/s
t
o
r
age
w
ar
r
an
t
y
Choosing a storage configuration
The following list describes configuration details for the P6300 EVA:
•
Two HSV340 controllers per controller enclosure
•
Four SAS ports
•
Four 1 GbE iSCSI or two 10 GbE iSCSI/FCoE connectors per con-
troller
•
1/10 (minimum/maximum) disk enclosures
•
8/120 (minimum/maximum) M6612 (LFF) disk drives
•
8/250 (minimum/maximum) M6625 (SFF) disk drives
The following list describes configuration details for the P6500 EVA:
•
Two HSV360 controllers per controller enclosure
•
Eight SAS ports
•
Four 1 GbE iSCSI or two 10 GbE iSCSI/FCoE connectors per con-
troller
•
2/20 (minimum/maximum) disk enclosures
•
8/240 (minimum/maximum) M6612 (LFF) disk drives
•
8/450 (minimum/maximum) M6625 (SFF) disk drives
Before you begin
Observe the following precautions when replacing a controller.
CAUTION:
HP recommends that you perform the replacement procedure
within seven minutes from when the controller is removed to
when it is replaced in the enclosure. Ensure all necessary parts
are available so the procedure can be completed without
interruption. Removing a controller module significantly changes
the air flow within the enclosure. Both controllers must be
installed for the enclosure to cool properly. If a controller fails,
leave it in place in the enclosure until a new module is available
to install. The enclosure could shut down due to overheating
unless the controller is replaced within the recommended seven
minutes.
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection. Refer to the documentation that shipped
with your system for additional information.