HP P9000 HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May
HP P9000 Manual
View all HP P9000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP P9000 manual content summary:
- HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 1
a command reference for HP StorageWorks P9000 RAID Manager Software on HP StorageWorks P9000 disk arrays. The intended audience is a storage system administrator or authorized service provider with independent knowledge of HP StorageWorks P9000 disk arrays and the HP StorageWorks Remote Web Console - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 2
2010, 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 3
Contents 1 Overview of commands 12 Command summary...12 Command format...16 Differences from Remote Web Console 17 Usable characters...17 Settable character length...19 Differences with Remote Web Console 20 2 Replication commands 21 paircreate...21 Syntax...21 Options and parameters...22 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 4
...86 Returned values...87 Error codes...87 Examples...87 raidvchkscan for Continuous Access Journal 90 Syntax...90 Options and parameters...91 Returned values...91 Error codes...91 Examples...91 raidvchkscan for Snapshot Pool and Thin Provisioning 93 Syntax...93 Options and parameters...94 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 5
Returned values...94 Error codes...94 Examples...94 horcmstart...95 Syntax...95 Options and parameters...96 horcmshutdown...96 Syntax...96 Options and parameters...97 horcctl...97 Syntax...97 Options and parameters...97 horctakeoff...98 Syntax...99 Options and parameters...99 Returned values...100 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 6
...115 Syntax...115 Options and parameters 115 Examples...119 mkconf...123 Syntax...124 Options and parameters 124 Example...124 5 Configuration setting commands 126 raidcom...126 Syntax...126 Options and parameters 126 Examples...127 Method for specifying LDEV number 127 Method for specifying - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 7
Syntax...134 Options and parameters 134 Examples...134 raidcom disconnect external_grp 134 Syntax...134 Options and parameters 135 Examples...135 raidcom get external_grp...135 Syntax...135 Options and parameters 135 Examples...135 raidcom modify external_grp 137 Syntax...137 Options and - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 8
...151 Syntax...151 Options and parameters 152 Examples...153 raidcom delete ldev...153 Syntax...153 Options and parameters 153 Examples...153 raidcom extend ldev...154 Syntax...154 Options and parameters 154 Examples...154 raidcom get ldev...154 Syntax...155 Options and parameters 155 Examples - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 9
Syntax...167 Options and parameters 168 Examples...168 raidcom delete path...168 Syntax...168 Options and parameters 168 Examples...168 raidcom disconnect path...169 Syntax...169 Options and parameters 169 Examples...169 raidcom get path...169 Syntax...169 Options and parameters 169 Examples... - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 10
raidcom add rcu_path...183 Syntax...183 Options and parameters 183 Examples...183 raidcom delete rcu_path...184 Syntax...184 Options and parameters 184 Examples...184 raidcom get resource...184 Syntax...184 Options and parameters 184 Examples...184 raidcom lock resource...185 Syntax...185 Options - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 11
Syntax...197 Options and parameters 197 Examples...197 6 Support and other resources 199 Contacting HP...199 Subscription service...199 Documentation feedback 199 Related information...199 HP websites...200 Conventions for storage capacity values 200 Typographic conventions...200 Glossary 202 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 12
can be executed from RAID Manager. The following table describes the replication commands: Table 1 Replication commands Command horcctl horcmshutdown horcmstart horctakeoff Description Used for both maintenance and troubleshooting on Continuous Access Synchronous. The horcctl command allows you to - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 13
to find the journal volume list setting via SVP. It also displays any information for the journal volume. The Continuous Access Journal function is available on the P9500, XP24000/XP20000, and XP12000/XP10000 Disk Arrays. raidvchkscan for Snapshot Supports the option (-v pid[a] [unit#]) to find the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 14
Table 2 Command tools for RAID Manager Subcommand inqraid mkconf Description Used to confirm the drive connection between the storage system and host system. The inqraid command displays the relation between special file(s) on the host system and actual physical drive of the RAID storage system. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 15
port. Displays port information. Displays LDEV information. Extends the virtual volume capacity of Thin Provisioning/Smart Tiers V-VOL. Creates LDEV or V-VOL. Deletes LDEV or V-VOL. Displays a parity group information. Displays the external volume information that is already registered. Changes the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 16
of Continuous Access Journal to be used at a journal. Displays a journal group information. Creates a pool for Snapshot. Creates a pool for Thin Provisioning. Deletes a pool for Snapshot/Thin Provisioning/Smart Tiers. Sets an option of a pool for Snapshot/Thin Provisioning/Smart Tiers. Displays - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 17
ldev_id ... ldev_id can be specified multiple times. Differences from Remote Web Console Some of the operations that can be performed by RAID Manager commands can be also performed from Remote Web Console. However, there are slight differences in usable characters for nicknames and - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 18
Figure 1 List of usable character codes for RAID Manager commands The following shows the characters that can be used for Remote Web Console commands in the ASCII codes. 18 Overview of commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 19
Device name LDEV nickname Resource group name WWN nickname Copy group name Pool name RAID Manager command 64 characters 32 characters 32 characters 32 characters 32 characters 32 characters 32 characters 32 characters Remote Web Console 64 characters 32 characters 32 characters 32 characters 32 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 20
Table 7 List of settable character lengths (continued) Name User name (User ID) User name (Password) RAID Manager command 63 characters 63 characters Remote Web Console 256 characters 256 characters Differences with Remote Web Console The operation procedures and the operatable contents are - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 21
This chapter provides specifications for the replication commands. paircreate CAUTION: Use the paircreate command with caution. The command starts the Continuous Access Synchronous, Continuous Access Journal, and Business Copy initial copy operations, which overwrite all data on the secondary - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 22
the command as [HORC]/[HO] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance Disk Arrays), an EX_ENOCTG error is returned. Therefore, the "CTGID" option can forcibly assign a volume group to an existing CTGID (0-15/63/127/255) on the RAID storage - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 23
OPEN-L. For Continuous Access Synchronous volumes paired between XP1024/XP128 Disk Array storage systems, the bitmap tables are managed at the Cylinder level, even if Track is specified. mode=grp [CTGID] (XP1024/XP128, XP12000/XP10000, XP24000/XP20000 and P9500 disk arrays; XP Business Copy Software - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 24
also is validated on Cnt Ac-S-Cnt Ac-S/Business Copy cascading operation using "-F BC [MU#]" option. The -fq option is applied for only XP24000/XP20000 Disk Array and XP12000 Disk Array/XP10000 Disk Array. This option is ignored for XP1024/XP128 Disk Array, because this behavior is to maintain the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 25
) Full, and its host side Write I/O is continued and Writing data is managed by BITMAP mode. Therefore o-time timeout value should have less a low value than I/O timeout value of the host system [c-time](Continuous Access Asynchronous only): This option is used when setting "Copy Pending timer" to - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 26
command. If the command fails, the detailed status is logged in the RAID Manager command log ($HORCC_LOG), even if the user OPEN Vol use. used by Continuous Access Synchronous/Continuous Access Asynchronous or BC/SS. Not enough Pool in RAID Could not retain the pool for executing a 206 command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 27
Example 2 The following figure shows an example for creating a suspended journal volume. On DC1 side: paircreate -g G1 -gs G2 -FHORC 2 -nocsus -f async -jp -js On DC2 side: paircreate -g G3 -vl -nocsus -f async -jp -js On DC3 side: paircreate -g G3 -vr -nocsus -f - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 28
can be applied to a paired logical volume or a group of paired volumes. The pairsplit command allows read access or read/write access to the secondary volume, depending on the selected options. When the pairsplit command is specified, acceptance of write requests to the primary volume depends on the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 29
shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. Specifies a group name defined in the configuration definition file. This - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 30
to be displayed when this command is executed. It is used to execute a command from a user program. This option must be specified at the beginning of a command argument. The command execution log is not affected by this option. Business Copy and Snapshot only. Copies difference data retained in the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 31
volume pair on Continuous Access Synchronous environment. If the -l option is specified, a cascading Business Copy volume is split on a local host (near site). If -l option is not specified, a cascading Business Copy volume is split on a remote host (far site). The target Business Copy volume must - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 32
236 command. manually to the identified 234 failed paired volume to try to recover it. If the trouble persists, call HP Technical Support Business Copy only), the pair is resynchronized in the reverse direction (For example, secondary volume to primary volume). The primary volume remains accessible - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 33
Disk Array or XP12000 Disk Array/XP10000 Disk Array), the "pairresync" operation is performed as Quick Resync regardless of the system option mode 87/80 setting via SVP. The $HORCC_RSYN and $HORCC_REST environment variables are ignored by XP1024/XP128 Disk Array. Continuous Access Synchronous - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 34
Figure 11 Normal Resync and Business Copy Restore Resync Figure 12 Normal Resync and Business Copy Restore Resync Syntax pairresync { -h | -q | -z | -g | -d | -d[g] - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 35
make this operation possible, RAID Manager supports the "pairresync -swaps - host must be P-VOL. (Business Copy volumes are able to resync only S-VOL.) Business Copy only. Performs reverse resync (from secondary volume to primary volume). -swaps Continuous Access Synchronous and Journal Software - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 36
Option -swapp Description Continuous Access Synchronous and Journal Software. Executes the equivalent of a -swaps from the original P-VOL side. Unlike -swaps, -swapp does require the cooperation of hosts at both sides. 36 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 37
> Description XP1024/XP128 Disk Array Business Copy only. Specifies the mode whether "pairresync" is performed or not as "QUICK". mode = normal pairresync is performed as Non quick mode regardless of setting of $HORCC_RSYN environment variable and/or the system option mode 87 via SVP. mode = quick - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 38
) Full, and its host side Write I/O is continued and Writing data is managed by BITMAP mode. Therefore o-time timeout value should have less a low value than I/O timeout value of the host system. [c-time]: (Applicable for only HORC Async) This option is used when setting "Copy Pending timer" to the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 39
in the RAID Manager command log ($HORCC_LOG), even if the user script has no error handling. The primary and secondary volumes must not be mounted on any UNIX system, because the pairresync command renews data on both the primary and secondary volumes. This command cannot execute copy rejection in - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 40
the group changes to the specified status. When the pairevtwait command with the -nowait option is issued for a group, the status is returned if the status of each volume in the group is identical. For Business Copy pairs, this command must be used to confirm a pair status transition. 40 Replication - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 41
mode and exits this command. Makes the pairevtwait command enter the interactive mode. The -zx option guards performing of the HORCM instance#] Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. -g - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 42
#] or -FBC [MU#] Forcibly specifies a cascading Business Copy volume for specified pair logical volumes on Continuous Access Synchronous environment. If the -l option is specified, this option tests status of a cascading Business Copy volume on a local host (near site). If no -l option is specified - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 43
manually to the identified 234 failed paired volume to try to recover it. If the trouble persists, call HP Technical Support. Timeout waiting for Increase timeout value using -t option. 233 specified status Timeout waiting for specified status on the local host Confirm that RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 44
-restore or pairsplit -S. The figure below shows five examples of waiting until "P-VOL_PSUS" & "S-VOL_COPY" state is changed to S-VOL_SSUS. Figure 20 Example of waiting for Business Copy 44 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 45
guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 46
to be reported: smpl, copy (includes rcpy), pair, psus HP StorageWorks P9000 RAID Manager Installation and Configuration User Guide storage system-internal code for the specified status. The following table specifies the results of the pairmon command options. Table 13 Results of pairmon command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 47
to the local host (issuing the command) or remote host. The volume attribute command. Makes the pairvolchk command enter the interactive mode. The -zx option guards performing command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 48
from a user program. This option must be specified at the beginning of a command argument. The command execution log is not affected by this option. -FHORC [MU#] or -FCA [MU#] Forcibly specifies a cascading Continuous Access Synchronous volume for specified pair logical volumes on Business Copy - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 49
returned values (continued) Condition Value For Continuous Access Synchronous and Business Copy 22: The status is P-VOL_COPY or P-VOL_RCPY. 23: The status is P-VOL_PAIR. 24: The status is P-VOL_PSUS. 25: The status is P-VOL_PSUE. 26: The status is P-VOL_PDUB (Continuous Access Synchronous & LUSE - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 50
status is S-VOL_PDUB (Continuous Access Synchronous & LUSE Remote Web Console. The default value is 80% of pool capacity. PFUS is set when the Snapshot pool became over threshold in the PSUS state. PFUL is set when the Snapshot pool became over threshold in the PAIR state. 50 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 51
example for Business Copy/Snapshot: # pairvolchk -g oradb pairvolchk : Volstat is P-VOL.[status = PAIR ] Display example for Business Copy (specified with "-m grp" option): # pairvolchk -g oradb pairvolchk : Volstat is P-VOL.[status = PAIR CTGID = 1] Display example for Continuous Access Synchronous - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 52
on Business Copy environment. The following figure shows a pairvolchk example that acquires the status (P-VOL_PSUS) of the intermediate S/Pvol (MU#1) through specified pair group on Continuous Access Synchronous environment. Figure 22 Example of -FHORC option for pairvolchk 52 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 53
TRUE x x x x TRUE false false x Group status COPY/RCPY PSUE PDUB PFUS PSUS PFUL PAIR COPY/RCPY PSUE PDUB PFUL PAIR PFUS PSUS COPY/RCPY NOTE: • The PFUL state appears as PAIR by all commands (except the -fc option of the pairdisplay command), since PFUL indicates PAIR state with sidefile at the HWM - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 54
the pair volume check command. Makes the pairdisplay command enter the interactive mode. The -zx option guards performing of the HORCM in #] Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 55
- - - Display example for Business Copy/Snapshot: # pairdisplay -g horc0 -fe Group ... Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M CTG CM EM E-Seq# E-LDEV# horc0 ... 63528 65.P-VOL COPY,63528 64 - - N - - - horc0 ... 63528 64.S-VOL COPY,----65 - - N - - CTG: For Continuous Access Synchronous/Cnt Ac-J, the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 56
is used when displaying a paired status of all mirror descriptors (MU#). This option (-m ) is not affected with command execution environment (Continuous Access Synchronous and Business Copy), and displays the paired status. This option cannot be specified with the -FHORC/-FMRCF option on the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 57
512345 62500 2 265 Notes: • This option can be specified with following options on the same command line: {-g | -d | -d[g] [MU#] | -FCA [ and then it shows the journal information for the remote host only. • This option displays nothing if the target volume is NOT - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 58
nothing if the target volume is NOT Continuous Access Asynchronous/Cnt Ac-J volume. "-FCA [MU#]" option is used when displaying the information of cascading Continuous Access Asynchronous/Cnt Ac-J volume, and then it shows the CT group information for the remote host only. 58 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 59
: This option displays nothing if the target volume is NOT Snapshot volume. -v pid -FMRCF The "-FBC [MU#]" option is used for displaying the pool information of cascading Snapshot volume, so that you can know/monitor the pool status on remote host connected to cascading Cnt Ac-S_P-VOL to Cnt Ac - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 60
= remote host (P,T#,L#) (Continuous Access Synchronous) = Port, TID, and LUN as described in the configuration definition file. (Port#,TID,LU-M) (Business Copy) = Port number, TID, LUN, and MU number as described in the configuration definition file. Seq# = Serial number of the RAID storage system - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 61
, or percent pair synchronization. Vol. COPY PAIR OTHER P-VOL S-VOL Continuous Access Asynchronous CR SF BMP - SF BMP COPY PAIR OTHER Continuous Access Synchronous Sync status CR BMP BMP - BMP BMP COPY PAIR P-VOL_PSUS S-VOL_COPY Business Copy status OTHER CR CR BMP CR CR - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 62
by the paircurchk command Object volume Currency Attribute SMPL P-VOL S-VOL Status COPY Fence Data Paircurchk To remote replication. 3. Inconsistent = Data in the volume is inconsistent because it was being copied. 4. OK = Mirroring consistency is not assured, but as S-VOL of Continuous Access - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 63
#] Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. the command. If the command fails, the detailed status is logged in the RAID Manager command log ($HORCC_LOG), even if the user script has - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 64
executes the chosen takeover function, and returns the result. The four Continuous Access Synchronous takeover functions designed for HA software operation are (see Horctakeover command functions in the Owner Guide): takeover-switch, swap-takeover, P-VOL-takeover, and S-VOL-takeover. A paired volume - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 65
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used to specify the RAID Manager instance Enables read and write to the primary volume(s) by a local host only without a remote host, and executes P-VOL-takeover when the primary volume cannot be used - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 66
guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 67
host view by finding a host group (XP1024/XP128 Disk Array and later). -s -t -l -f or -ff -fx -fg -fd -fe Used to specify the Seq# (serial#) of the storage specified, the command applies to all local RAID Manager the external LUNs only mapped to the LDEV. If the external LUN - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 68
descriptor for Cnt Ac-J, -m must be specified in Continuous Access Synchronous or Business Copy command environment. If you want to display all cascading mirror descriptor, to show a LUN on the host view by finding a host group (XP1024/XP128 Disk Array and later). 68 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 69
can be used with "-fx" option to display LDEV numbers in hexadecimal. Example for HP-UX: # ioscan -fun | grep rdsk | raidscan -find inst DEVICE_FILE Group MU# for Business Copy/Snapshot are shown as "0", "1", "2". • SERIAL: This displays the production (serial#) number of the RAID storage system. • - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 70
command Continuous Access Synchronous are shown as "-", and MU# for Business Copy/Snapshot are shown as "0", "1", "2". • Device_File: This displays Device_File which is registered to the LDEV map tables into the RAID Manager. • SERIAL: This displays the production (serial#) number of the RAID storage - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 71
option is used when displaying a LUN on the host view by finding a host group (XP1024/XP128 Disk Array and later). # cat /etc/horcmperm.conf | dev/rdsk/c24t0d3 SER = 61456 LDEV = 195 [ OPEN-3 ] If the target device is mixed with a different RAID TYPE, then its target device is suppressed as a - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 72
(1) Windows NT does not support the LDM volume, so already opened by any applications, opening state), and indicates the behavior as [FLUSH] below: [FLUSH] : ORA ORA_000[-] -> \Vol44\Dsk0 : Volume{56e4954a-28d5-4824-a408-3ff9a6521e5d} Returned values None Error codes None Examples raidscan command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 73
the storage system (not from the configuration definition file). The I/O activity of a Continuous Access Synchronous S-VOL in the COPY or PAIR state includes Continuous Access Synchronous remote I/Os (update copy operations) in addition to host-requested I/Os. The I/O activity of a Business Copy - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 74
specified LUN (Business Copy only). -pd[g] -s [interval] or -sm [interval] -s -sm [ interval] [count] Allows designation of an LDEV by raw device file name. The -pdg option is used to show a LUN on the host view by finding a host group (XP1024/XP128 Disk Array and later). Designates - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 75
the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. Displays the configuration information for the local host and the local RAID storage system. Displays the configuration information for the remote host and - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 76
Manager on the local or remote host. The -l option specifies local host. The -r option specifies remote host. Uid Serial# Micro_ver: This column shows unitID, serial number, and (DKCMAIN) microcode version of the storage definition file. RAID_type: The type of RAID configured in the group. IV/H: - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 77
mode and exits the command. Makes the raidvchkset command enter the interactive mode. The -zx option guards performing of the HORCM in instance#] Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 78
of "0x ") or decimal notation. If this option is not specified, then a region for a target volume is set as all blocks (slba=0,elba=0). 78 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 79
the copy series program product and the host access, copy processing of the copy series program product. • [rtime]: Specifies the retention time, in units of day. If [rtime] is not specified, the default time defined by the storage system is used. The default time is "zero" in XP1024/XP128 Disk Array - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 80
guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 81
(instance), then the volume is not recognized on own HOST, and raidvchkdsp command is rejected in protection mode. Non-permitted volume is shown without LDEV# information (LDEV# is "- "). -fe Displays the serial# and LDEV# of the external LUNs mapped to the LDEV for the target volume by adding - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 82
RAID needs to specify "Port#, Targ#, Lun#" and "LDEV" for specifying the target device, and then HORCM keeps this information as internal database for the configuration. If a storage command shows the real LDEV mapping at the time of the command usable capacity of the Snapshot pool corresponding to - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 83
- horc0 ... 0 20 63528 66 E E E E E E E E E E 0 - - - Output of the raidvchkdsp command with -fe option: EM: This column displays the external connection mode. H = Mapped E-lun is hidden from the host. V = Mapped E-lun is visible to the host. - = Unmapped to the E-lun. BH = Mapped E-lun as - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 84
Seq# LDEV# Bsize STLBA ENLBA BNM vg01 oradb1 c4t0d2 2332 2 1024 1 102400 9 vg01 oradb2 c4t0d3 2332 3 1024 1 102400 9 Output of the raidvchkdsp command with -v offset option: Bsize: This column displays the data block size of Oracle I/O, in units of bytes. STLBA: Displays the start of - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 85
the retention time is infinite. The application knows whether the target volume is with Audit lock status. Example 6: raidvchkdsp command example with the -v pool option raidvchkdsp Snapshot pool in units of Bsize. Capacity(Bsize): Displays the total capacity in the Snapshot pool in units - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 86
guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 87
Disk Array and later): Shows a LUN on the host view by finding a host group. -s -t -l -fx -v [op] Used to specify the Seq# (serial#) of the storage option is not specified, the command applies to all LUNs. If the restore operation of the Snapshot. aou[b]: Displays the LUN capacity - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 88
contained in the data block is enabled. D: Referring for CHK-F1 flag contained in the data block is disabled. Example 2: raidvchkscan command example with the -v offset option # raidvchkscan -p CL1-A -v offset PORT# /ALPA/C TID# LU# Seq# Num LDEV# CL1-A / ef/ 0 0 0 2332 1 0 Bsize 1024 STLBA - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 89
regarding CHK-F2, in units of bits. If BNM is zero, this means the checking for CHK-F2 is disabled. Example 3: raidvchkscan command example with -v errcnt option # raidvchkscan -p CL1-A -v errcnt PORT# /ALPA/C TID# LU# Seq# Num LDEV# CL1-A / ef/ 0 0 0 2332 1 0 CL1-A / ef/ 0 0 1 2332 1 1 CL1 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 90
of day. The hyphen (-) shows that the retention time is infinite. The application knows whether the target volume is denied to change to writing enable by Continuous Access Journal The raidvchkscan command supports the (-v jnl [t] [unit#]) option to find the journal volume list setting via SVP - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 91
the command. Makes the raidvchkscan command enter the interactive mode. The -zx option guards performing of the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. Used to specify the Seq# (serial#) of the storage - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 92
number of the RAID storage system. Num: application will know the following detail state. The following table lists information about the different journal volume statuses. QCNT=0 indicates that the number of remaining Q-Markers is '0'. The letter 'N' indicates a non-zero. 92 Replication commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 93
for detecting Link failure. raidvchkscan for Snapshot Pool and Thin Provisioning The raidvchkscan command supports the option (-v pid[a] [unit#]) to find the Snapshot pool or Thin Provisioning pool settings via SVP, and displays information for the Snapshot pool or Thin Provisioning pool. Syntax - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 94
command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. Used to specify the Seq# (serial#) of the storage of the Snapshot/Thin Provisioning pool. SSCNT: Displays the number of Snapshot volume in Snapshot pool or the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 95
RAID storage system. Num: Displays the number of LDEV configured the Snapshot/Thin Provisioning pool. LDEV#: Displays the first number of LDEV configured the Snapshot Provisioning pool. horcmstart The horcmstart command is a shell script that starts the HORCM application (/etc/horcmgr). This shell - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 96
uses the environment variables set by the user. If you have designated full environment variables and Configuration Guide. NOTE: Commands are issued to the local instance host. To specify horcmshutdown The horcmshutdown command is a shell script for stopping the HORCM application (/etc/horcmgr). - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 97
guards performing of the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode terminates. OpenVMS cannot use the -zx option. Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 98
the parameters of the HORC Manager (HORCM). Sets the HP representative. Level 4 is the normal trace level setting. Levels 0-3 are for troubleshooting. Setting a trace level other than 4 may impact problem resolution. If you request a change of the trace level using the horcctl -l command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 99
and exits the command. Makes the raidvchkdsp command enter the interactive mode. The -zx option guards performing of the HORCM [instance#] Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager instance number. -g[s] - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 100
codes If the command failed, then the detailed status is logged in RAID Manager command log ($HORCC_LOG), even though the user script has error Local and Remote Volume currency error Timeout waiting for specified status Value 236 229 235 223 233 Examples Example 1 horctakeoff command on L1 local - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 101
1' is in progress. horctakeoff : horctakeoff done. Example 3 horctakeoff command on L1 remote site # horctakeoff -g G1 -gs G2 horctakeoff : 'pairsplit -g done. pairsyncwait The pairsyncwait command is used to confirm data consistency between the Continuous Access Asynchronous/Cnt Ac-J P-VOL - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 102
remote site can split the cascading Business Copy volumes (Continuous Access Asynchronous/Cnt Ac-J to Continuous Access Asynchronous/Business Copy/Cnt Ac-J) without splitting Continuous Access remote site by using RAID Manager-unique API command. Figure 25 Synchronization for Continuous Access - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 103
command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy], and used when specifying the RAID Manager application does not specify Q-marker, RAID Manager uses the latest sequence # when RAID Manager this command is executed from a user program. This option must be specified at - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 104
Other cases reply with error (EX_INVVOL). It is possible to issue pairsysncwait from S-VOL side with -m . Returned values The pairsyncwait command sets the following returned values during exit, allowing you to check the execution results. Condition Returned value When the -nowait option - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 105
command. If the command failed, the detailed status will be logged in the RAID Manager command log ($HORCC_LOG), even if the user was resynchronized while this command is executed. The output of the pairsyncwait command is: UnitID: Unit ID in the case of multiple storage system connection. CTGID - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 106
must delete the drive letter assigned to the command device to prevent utilization by general users. The "Volume{GUID}" must be made by setting a partition using the disk management without file system format, and is used to keep as the same command device even though the physical drive numbers are - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 107
Shows the production number (serial number) of the storage system. LDEV#: Shows the LDEV ID (hexadecimal) of the specified volume. HORC: Shows the Continuous Access Synchronous attribute (P-VOL, S-VOL, SMPL) of the specified volume. BC: Shows the Business Copyattribute (P-VOL, S-VOL, or SMPL) and MU - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 108
becomes a pair in or among the RAID storage system. sync, syncd The sync (synchronization) subcommand sends unwritten data remaining on the Windows server to the specified device(s) to synchronize the pair(s) before the RAID Manager command is executed. The syncd (synchronization delay) subcommand - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 109
hard disks. The logical drive on which the RAID Manager software is User and Reference Guide. Examples The following examples show the sync subcommand used as an option of the pairsplit command disk, all pairs in the specified group are deleted (status = SMPL), which enables read/write access - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 110
a problem that NTFS on P-VOL is split on inconsistent state because Windows 2003 delays the IO for dismounting. If sync has failed, you need to confirm the following conditions: The logical and physical drives designated as the objects of the sync command are not opened to any applications. For - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 111
in the User and Reference Guide. [\directory]: Specifies the directory mount point on the logical drive. pairsplit -x mount D:\hd1 \Vol8 D:\hd1 HarddiskVolume8 pairsplit -x mount D:\hd2 \Vol9 D:\hd2 HarddiskVolume9 Restriction The partition on the specified disk drive (hard disk) must be - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 112
to be unmounted and the corresponding physical drive must be closed to all applications. Example The following shows an example of the umount subcommand used as an option of the pairsplit command. umount subcommand example pairsplit -x umount F: -x umount G: -g oradb -rw pairsplit -x mount Drive - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 113
, ID51,57). These problems do not occur on Windows 2008 systems. Environment variable subcommands If no environment variables are set in the execution environment, the following environment variable subcommands set or cancel an environment variable within the RAID Manager command. setenv: The setenv - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 114
Environment variable subcommand examples raidscan[HORC]: -x setenv HORCC_MRCF 1 raidscan[MRCF]: raidscan[MRCF]: -x usetenv HORCC_MRCF raidscan[HORC]: 114 Subcommands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 115
This chapter describes the RAID Manager command tools. inqraid The inqraid command is a RAID Manager command tool used to confirm the drive connection between the storage system and host system. The inqraid command displays the relation between special file(s) on the host system and actual physical - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 116
LDEV# Normally this option is used to save the signature and volume layout information once after setting the new partition for S-VOL using the Windows Disk Management. Windows systems only. -svinfex[=PTN] is for GPT disk. Sets the signature and volume layout information that was saved to the system - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 117
5:01-02 OPEN-3 This example shows that c57t4d0 and c57t4d3 (marked by *) are set to enable Database Validator checking (-fp option). The raidvchkset command is used to enable/disable volume protection. -fg (XP1024/XP128 Disk Array and later): Shows a LUN on the host view by finding a host group for - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 118
"Keyword, Serial#, Ldev#, Device file name, ...". The raidscan -find inst command on the RM (local) server imports the device information, and registers it into the HORCM deamon. See Remote Volume Discovery in the User and Reference Guide for more details. Example: # ls /dev/rdsk/c1t* | inqraid -CLI - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 119
in the User and Reference Guide. Lines starting with '#' via STDIN are interpreted as comments. Examples The following examples show how to use the inqraid and system command to display the connection between special file of STDIN and the actual physical drive of the storage system. HP-UX system - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 120
in the RAID storage system. HORC: Displays the attribute ("P-VOL/S-VOL/SMPL") of a volume as Continuous Access Synchronous in the RAID storage system. HOMRCF: Displays the attribute ("P-VOL/S-VOL/SMPL") of a volume as MU#0-2 of Business Copy/Snapshot in the RAID storage system. 120 Command tools - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 121
number] SNAPS[PoolID poolID number ] UNMAP[Group 00000] E-LUN[Group External Group number] A-LUN[PoolID poolID number ] SSID: Displays Sub System ID of the LDEV in the RAID storage system. CTGID: Displays CT group ID of Continuous Access Asynchronous/Cnt Ac-J when the LDEV has been defined as the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 122
remote Continuous Access Synchronous volume, Business Copy/Snapshot volume, and Business Copy/Snapshot MU#1,2 volumes. SSID: Displays the Sub System ID of an LDEV in the storage external command device, if the command device is mapped as ELUN(R: =E). inqraid: example of -cliwp and -cliwn options (HP - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 123
Copy only) and the system is rebooted, the system cannot create a Device object (\Device\HarddiskVolume#) and Volume{guid} for S-VOL, but a Device object (\Device\HarddiskVolume#) and Volume{guid} is created by using -svinf option after splits the S-VOL. mkconf The mkconf command is a RAID Manager - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 124
on the host view by finding a host group (XP1024/XP128 Disk Array and later). Specifies the mirror descriptor for Business Copy volume. Continuous Access Synchronous volume does not specify the mirror descriptor. Specifies the instance number for HORCM. Specifies the service name for a configuration - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 125
OPEN-3-CM ] - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 126
and Log-out raidcom {-login [ ] | -logout] [-s | -u ] Instruction of Configuration change (Line by Line mode) RAID Manager command requires the user name and the password. If the same user is set for multiple hosts, the session control table of each host is managed - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 127
at the beginning of the command parameter. This option specifies a script file. This option specifies a file name of a file (configuration file) that is created for implementation check. Examples Performing user authentication (login) by the user ID: USER01 and the password: PASS01. raidcom -login - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 128
journal -journal_id 1 -ldev_id 265 -cnt 4 (c) Creating pool Create a pool for Snapshot by a specified LDEV. raidcom add snap_pool -pool 1 -ldev_id 365 366 367 -cnt 5 raidcom add copy_grp Creates a copy group. Syntax raidcom add copy_grp -copy_grp_name [ - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 129
be specified up to two. Specifying more than two is ignored. name>[] For a copy group for a Cnt Ac-S pair, specify only one device group for the relevant DKC side. [-mirror_id ] Specifies - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 130
Description on each column in output example COPY_GROUP Copy group name LDEV_GROUP Device group name that composes copy group MU# Mirror ID to which the device group belongs If -mirror_id is not groups. This deletes the specified LDEV from the specified group. 130 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 131
(max. 32 characters). If the specification is omitted, the list of the registered device groups is displayed. If the specification is performed. the information of the specified device groups (configured LDEVs) is displayed. Examples Displaying device group information. # raidcom get device_grp - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 132
of the external storage system port. [-emulation ] The valid values that can be specified to are the following values OPEN-3, OPEN-8, OPEN-9, OPEN-E, OPEN-L, OPEN-V 132 Configuration - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 133
0 defined to the external storage system port: 50060e80,05fa0f36 connected to the port: CL1-A (External port) by the External Volume Group#1-1 and the console window. Example EGRP 1-1(0x1-0x1) will be used for LDEV# 200 If no LDEV exists in the external volume, it is denied with EX_ENOOBJ command. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 134
device group belongs to, and the result is displayed in the console window. For example: EGRP 1-1(0x1-0x1) will be used for LDEV# 200 If no LDEV exists in the external volume, it is denied with EX_ENOOBJ command. Syntax raidcom disconnect external_grp {-external_grp_id | -ldev_id - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 135
the specification is omitted, the list of the registered external volumes is displayed. If the specification is performed. the LDEV information defined for the specified external volumes is displayed. For example: 52-11 Examples Displaying external volume information (The display might not be in - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 136
partition number in this External Volume Group. LDEV# This displays LDEV number assigned to this External Volume Group. STS This displays the following status. - NML: this means the status of "Normal" in LDEV. - REG: this means the status of "Registering" in LDEV. 136 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 137
y Changing the MP Blade ID of the External Volume Group#01-01 to "3". raidcom modify external_grp -external_grp_id 01-01 -mp_blade_id 3 raidcom discover external_storage Searches the port information on the external storage system connected to the external port. raidcom modify external_grp 137 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 138
. "OTHER" is displayed if an unsupported external storage system is connected. PRODUCT_ID This displays the PRODUCT_ID of the external storage system. "OTHER" is displayed if an unsupported external storage system is connected. raidcom add host_grp Creates a host group to the specified port. If the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 139
name. Up to 64 characters can be set by RAID Manager. When more than 64 characters name is set, a command that is specified host group name by Remote Web Console cannot be executed. Examples Creating a host group ID: 3, the host group name: a host group of Win_export, to the port: CL4-E. raidcom - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 140
following BITs for HOST mode option setting on host group. BIT meaning 2 VERITAS Database Edition/Advanced Cluster 6 TPRLO 7 Automatic recognition function of LUN 12 Undisplay function of ghost LUN 13 SIM report at link failure 14 HP TruCluster with Continuous Access Synchronous function 15 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 141
"OHUB PCI retry" 43 Queue Full Response 48 ESAM Svol Read Option 54 Support Option for the EXTENDED COPY command raidcom modify host_grp This sets a host mode to the host group on the specified port. If you want to set Host mode option, then specify "-host_mode_opt" option. If you want to reset - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 142
following strings. For more details, see the HP StorageWorks P9000 Provisioning for Open Systems User Guide. • LINUX/IRIX • VMWARE • HP-XP • OVMS • TRU64 • SOLARIS • NETWARE • WIN • AIX • VMWARE_EX • WIN_EX • Ext Storage [ -host_mode_opt ... ] 142 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 143
Response 48: ESAM Svol Read Option 54: Support Option for the EXTENDED COPY command This parameter is used when setting the option bits for the host mode option. For more details, see the HP StorageWorks P9000 Provisioning for Open Systems User Guide. Byte [n] MSB-------Bit------LSB Byte [0] 00 01 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 144
host group name. Use the host group ID. For example: • CL1-A-g (g is from 0 to 255) • CL1-A Linux_X86 Specifies a WWN value (hexadecimal value) of host of host bus adapter: 210000e0, 8b0256f8 to the port: CL4-E, the host of host bus adapter: 210000e0,8b039800 set for the port: CL4-E, the host group - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 145
set for the host group name. Use the host group ID. If setting the host group ID or if the host group name is omitted, the information about host group ID 0 is as "Open System". A device group can also be specified instead of an LDEV. This command is executed asynchronously with the command input. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 146
if the specification is omitted. In this command, effective value is up to 64. - Ac-J manual for the Timer Type option. For example: • -timer_type system • -timer_type local Examples For Open: timer type, the system clock of the mainframe host is used. (When LDEV is added to the journal - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 147
both LDEV or Device group are not specified, journal is deleted. This command is executed asynchronously with the command input. Check the completion of this process on the raidcom get command_status command. Syntax raidcom delete journal -journal_id [-ldev_id | -grp_opt - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 148
raidcom get jnl_grpt -pkey opt JID MU CTG JNLS TYPE TTYPE MODE IF DOW(S) PBW(M) CR CS(bps) DM MP# Seq# 001 0 1 PJNN OPEN - HDD E 30 5 M 256 Y 2 64034 002 1 2 PJNF M/F system CACHE D 30 5 H 256 Y 2 64034 Description on number (Q-marker) written to the cache. Q-CNT 148 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 149
Sec.) timer setting to detect any link failures. TYPE This displays a type for "Open" or "M/F" system. TTYPE This displays the timer type for M/F. - system: using This displays the copy rate as "Low/Medium/High". CS(bps) This displays the copy speed as "10/100/256". DM This displays the copy mode as - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 150
option cannot be used for changing from "Open System" to "M/F System." Syntax Specify more watch for the path blockage (1-60) (minutes). Use Remote Web Console to set the value with more than 60 minutes. If For details, see the Cnt Ac-J manual for the Timer Type option. For example: • - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 151
ID during initial copying of Continuous Access Journal (on-peak of the mainframe host. # raidcom Journal: 6. Instructing to store journal external volume group. Or, makes V-VOL for Thin Provisioning/Smart Tiers/Snapshot to the specified pool. This command is executed asynchronously with the command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 152
1048576k, -capacity 2097152 In case of volumes other than OPEN-V, it is required the more free space than the capacity which is actually specified. For more details, see the P9000 Provisioning for Mainframe Systems User Guide. -offset_capacity Specifies capacity. Corrects the size. The - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 153
automatically, emulation type: OPEN-V, External volume: 01-02, Capacity: 200MB, and LDEV number: 200. raidcom add ldev -external_grp 01-02 -ldev_id 200 -capacity 200m Creating a V-VOL of Capacity: 300MB and LDEV number: 300, to a pool for Thin Provisioning/Smart Tiers. raidcom add ldev -pool - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 154
extend ldev Extends the capacity of V-VOL for Thin Provisioning/Smart Tiers Smart Tiers a capacity to be extended. The unit is g/G, extend ldev -ldev_id 200 -capacity 10G Extending the capacity of a Thin Provisioning V-VOL: 201 by 200 MB. raidcom extend ldev -ldev_id 201 -capacity 200M Extending extend - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 155
attribute. LDEV attribute frnt rgrp Normal volume Internal volume Y Y External volume Y N Volume (V-VOL) for Pool Snapshot/Thin Provisioning/Smart Tiers Y N Journal volume Internal volume N Y External volume N N Legend Y: Displayed N: Not displayed Examples Displaying the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 156
63502 LDEV : 577 SL : 0 CL : 0 VOL_TYPE : OPEN-V-CVS VOL_Capacity(BLK) : 2181120 VOL_Capacity(cyl ) : 22720 (Displayed only Disk Array). CL It shows the information of CLPR. VOL_TYPE It shows an emulation type of the relevant LDEV. This displays the same name as the product ID of the Inquiry command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 157
volume HORC: Continuous Access Synchronous Volume (P-VOL or S-VOL) MRCF: Business Copy Volume (P-VOL or S-VOL) QS: Snapshot Volume (P-VOL or S-VOL) JNL: JNL Volume THP: Thin Provisioning (THP) Volume POOL: POOL Volume QRD: Quorum disk ENCD: Encryption disk SYSD: System disk RAID_LEVEL It shows - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 158
NML: Normal BLK: Blocked BSY: Status is changing NONE: unknown state (not supported) OPE_TYPE It shows the in current operation. FMT: Formatting QFMT: Quick Formatting CCOPY: Copying the collections CACCS: Accessing to collections NONE: Not in operation SHRD: Shredding ZPD: Page Discarding OPE_RATE - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 159
the number of alternate paths. E_PORTs It enumerates the defined alternate paths. Examples If the LDEV number 160 is an external volume, its back-end (RAID Group) information is displayed. Displaying the information of the LDEV number 640 (V-VOL of Thin Provisioning). # raidcom get ldev -ldev_id - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 160
, all the LDEVs belonging in the device group are operated. -operation Instructs the operation. The following operation can be specified: fmt: Normal Format qfmt: Quick Format shrd: Shredding Examples Performing Quick Format for a LDEV: 200. raidcom initialize ldev -operation qfmt -ldev_id - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 161
for Smart Tiers Instructing the page discarding of V-VOL for Thin Provisioning/Smart Tiers Setting SSID Setting command device Do not change the MP blade ID during initial copying of Continuous Access Synchronous, Business Copy or Continuous Access Journal (on-peak hours of I/O loading). To - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 162
Smart Tiers V-VOL):200 raidcom modify ldev -ldev_id 200 -status discard_zero_page Specifies 0x1234 to LDEV SSID of LDEV: 200. raidcom modify ldev -ssid 0x1234 -ldev_id 200 Enables LDEV command specified instead of an LDEV. If the specified port and host group does not exist, it will be rejected with - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 163
-grp_opt ldev -device_grp_name grp1 raidcom delete lun Deletes the LU path on the host group on the specified port. An LDEV or a device group can also be of a LUN. If an LDEV does not exist on the specified port/host group/LUN, it will be rejected with EX_ENLDEV or EX_ENOOBJ. When deleting the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 164
host External. For example: • CL1-A -external_wwn value can be split in units of 4 bytes by "," (commas). For example: • 21000e08b0256f8 • 21000e0,8b0256f8 164 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 165
HITACHI R50111A803 HITACHI R50111A803 CL7-A 50060e801611a870 9 819840 OPEN-V 00309 HITACHI R50111A803 HITACHI R50111A803 CL7-A 50060e801611a870 10 819840 OPEN-V 0030A HITACHI R50111A803 HITACHI R50111A803 PORT Displays the External Initiator port number. WWN Displays the WWN on the external storage - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 166
host group. BIT meaning 2 VERITAS Database Edition/Advanced Cluster 6 TPRLO 7 Automatic recognition function of LUN 12 Undisplay function of ghost LUN 13 SIM report at link failure 14 HP TruCluster with Continuous Access Synchronous function 15 HACMP 22 Veritas Cluster Server 23 REC command support - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 167
-A, external storage system port 50060e80,05fa0f36 to an external volume path group number: 1. raidcom add path -path_grp 1 -port CL1-A -external_wwn 50060e80,05fa0f36 raidcom check_ext_storage path Restores an external path to external VOLs. Only one path is operated in one operation. This command - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 168
-A, and external storage system port 50060e80,05fa0f36. raidcom check_ext_storage path -path_grp 1 -port CL1-A -external_wwn 50060e80,05fa0f36 raidcom delete path Deletes the external path or alternative path to an external volume. Only one path is operated in one operation. This command is executed - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 169
). For example: • 21000e08b0256f8 • 21000e0,8b0256f8 Examples Blocks the usage of a path of the external volume path group number: 1, the external port CL1-A, and the external storage port 50060e80,05fa0f36. raidcom disconnect path -path_grp 1 -port CL1-A -external_wwn 50060e80,05fa0f36 raidcom - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 170
path. - BLK: this means the status of "blockading" in external path. - DSC: this means the status of "disconnected" in external path. - UNK: this means the status of "Unknown" in external path. -Serial# This displays the serial number of external storage system. 170 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 171
This displays the PRODUCT_ID of the external storage system. raidcom delete pool Deletes the specified pool for Snapshot/Thin Provisioning/Smart Tiers. The deletion of pool VOL is not supported on Version01. This command is executed asynchronously with the command input. Check the completion of this - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 172
capacity. "-" indicates unlimited. raidcom modify pool Sets the option of a pool for Snapshot/Thin Provisioning/Smart Tiers. When specifying the -status option, the operation is executed asynchronously with the command input. Check the completion of this process on the raidcom get command_status - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 173
user-defined threshold. The valid range for Thin Provisioning/Smart Tiers is 5-95%. The valid range for Snapshot is20-95%. • For Thin Provisioning/Smart Tiers, you may specify two user the pool for Smart Tiers. It is changed to manual reallocation. • thp: Changes the pool for Smart Tiers to the pool - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 174
Smart Tiers to the pool for Thin Provisioning. # raidcom modify pool -pool 6 -pool_attribute thp Changing the automatic reallocation of the pool (Pool name: my_pool) for Thin Provisioning to manual (RCU Target port) • ELUN: External Initiator port (External port) 174 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 175
where a port is belonging. Serial# Product serial number. WWN This displays the external WWN PHY_PORT When the version of DKCMAIN program is "70-02-0X-XX/XX", the currently connected WWN is displayed unlike the display on Remote Web Console. Serial# Product serial number. For example for getting - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 176
Option -port Description Specifies a port number. For example: • CL1-A [ -port_speed Specifies a HOST speed (0, 1, 2, 4, 8). ] The contents that can be specified: 0: AUTO 1: 1G 2: 2G 4: 4G PtoP n-port is used if the specification is omitted. 176 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 177
Initiator port) RCU: RCU Target port (RCU target port) ELUN: External Initiator port (External port) Examples Changing the port attributes (the Loop ID and the parity groups defined in the DKC. If the specification is performed, the LDEV information defined in the specified parity group. For - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 178
the RAID Level of Parity Group or of external volume group. R_TYPE This displays the RAID Type of Parity Group or of the external volume External volume group GROUP This displays the Parity Group number or the external volume group number. P_NO This displays the partition number partitioning - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 179
RAID Type, and it can be specified the following strings. XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600, P9500:R700 < pid> is used to set the path group ID (1-255). Specifies a port number of the MCU. Specifies a port number on the RCU (storage system port on the remote - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 180
-Serial# Product serial number. -ID This displays the ID for identifying RAID type. XP12000 Disk Array/XP10000 Disk Array : R5, XP24000/XP20000 Disk Array : R6, P9500 : R7 PID This displays a path group ID. If displayed. -M/R This displays the CU type as MCU/RCU. 180 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 181
RCU, "-" is displayed. -RTO (s) This displays the timeout value for RIO (Remote IO) setting between MCU and RCU. -RTT (ms) This displays the round trip -ID This displays the ID for identifying RAID type. XP12000 Disk Array/XP10000 Disk Array :R5, XP24000/XP20000 Disk Array : R6, P9500 : R7 PID This - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 182
control parameters to CU that is specified using two way. Syntax raidcom modify rcu -cu_free -rcu_option 182 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 183
. XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600, P9500:R700 is used to set the path group ID (0-255). -mcu_port -rcu_port Specifies a port number on the MCU. Specifies a port number on the RCU (storage system port on the remote side). Specify - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 184
. XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600, P9500:R700 < pid> is used to set the path group ID (1-255). -mcu_port -rcu_port Specifies a Port number on the MCU. Specifies a port number on the RCU (storage system port on the remote side). Specify - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 185
a host name of a user who locks the resource group name. Serial# Product serial number. raidcom lock resource Locks the specified resource group name. If the specified resource group name does not exist, it will be rejected with EX_ENOOBJ. In authentication mode, the user executing this command must - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 186
This command is executed asynchronously with the command input. Check the completion of this process on the raidcom get command_status command. the pool ID is allocated automatically. Specifies a pool name of a pool for Snapshot. Up to 32 characters can be specified. When specifying a pool ID or a - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 187
If you want to change the user defined threshold value of the additional pool volume, execute the raidcom modify pool command. Examples Using LDEVs:400, 401 creating a pool of Pool ID: 2, Pool Name: Allocated automatically for Snapshot. # raidcom add snap_pool -pool_id 2 -ldev_id 600 601 602 Using - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 188
Smart Tiers. Or, adds a pool volume. A device group can also be specified instead of an LDEV. When specifying a pool that is already created for Snapshot This command is executed asynchronously with the command input. Check the completion of this process on the raidcom get command_status command. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 189
Thin Provisioning with the user-defined thresholds WARNING specified to 70% and High water mark to 80%. # raidcom add thp_pool -pool_id 3 -pool_name my_pool -ldev_id 700 701 702 -user_threshold 70 80 Add LDEV: 368 to the pool ID: 10 for Thin Provisioning/Smart Tiers. # raidcom add thp_pool -pool_id - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 190
the pool for Thin Provisioning/Smart Tiers. # raidcom get thp_pool PID PID This displays the Thin Provisioning/Smart Tiers pool ID. POLS This displays the for the Thin Provisioning/Smart Tiers volumes mapped to this pool total number of Thin Provisioning/Smart Tiers volumes mapped to the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 191
pool for Smart Tiers is displayed. For details about each parameter, see the manual HP StorageWorks P9000 Provisioning for Open Systems User Guide. # /termination of the monitor is performed by the instruction of the CLI, and the Tier range setting is performed by the automatic calculation of the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 192
Tier capacity (Total capacity) T(%) The free space percentage for the newly allocation P(%) Performance RAID Manager. Up to 64 characters can be set by Remote Web Console. Examples Giving the nickname of "ORA_NODE0_CTL_0" to the connection host "WWN: 210000e0,8b0256f8" to which the CL4-E and host - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 193
pool name. -operation Instructs the operation of performance monitoring. The operational types that can be specified: start: Start the performance monitoring. stop: Stop the performance monitoring. Examples Starting the performance monitoring of a pool for Smart Tiers of the Pool ID: 20 - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 194
instruction The operational types that can be specified: start: Start the tier reallocation. stop: Stop the tier reallocation. Examples Starting the tier reallocation of a pool for Smart Tiers After executing asynchronous command, check the error information by executing this command. However, an - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 195
to complete the process of asynchronous command. If the specification of parameter HP StorageWorks P9000 RAID Manager User Guide. SSB2 SSB2 error code. For more details about error codes, see HP StorageWorks P9000 RAID Manager User Guide. ERR_CNT The total number of errors that occur in this user - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 196
group name. When you specify resource group name, LDEV number, port number, host group number, parity group ID or an external group ID, the specified resource is registered to the specified resource group.If 5 Add LDEV: 400 to the resource group: sql_srv. 196 Configuration setting commands - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 197
Deletes the resource groups. Deleting the resource groups cannot be performed unless all resources that are registered to the target resource groups are deleted.LDEV number, port number, host group number, parity group and external group are deleted from the specified resource groups. The deleted - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 198
sql_srv. # raidcom delete resource -resource_name sql_srv -port CL1-A Deleting a host group of CL1-A-0 from the resource group: sql_srv. # raidcom delete raidcom delete resource -resource_name sql_srv -parity_grp_id 33-16 Deleting an external volume group: 01-02 from the resource group: sql_srv. - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 199
Guide • HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide • HP StorageWorks P9000 Provisioning for Open Systems User Guide • HP StorageWorks P9000 RAID Manager Reference Guide • HP StorageWorks P9000 RAID Manager User Guide • HP StorageWorks P9000 Remote Web Console - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 200
, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/service_locator • http://www.hp.com/support/manuals • http://www.hp.com/support/downloads • http://www.hp.com/storage/whitepapers Conventions for storage capacity values P9000 disk arrays use the - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 201
continued) Convention Monospace text Element • File and directory names • System output • Code • Commands, their arguments, and argument values Monospace, italic text • Code variables • Command : Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 202
. Cache logical partition. Computer network technologies. P9000 or XP Continuous Access Journal software. P9000 or XP Continuous Access Synchronous software. A volume in the disk array that accepts Continuous Access, Business Copy, or P9000 for Business Continuity Manager control operations, which - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 203
, or both. The CLI configuration and replication tool for the P9000 or XP disk array that system administrators can use to enter RAID Manager commands from open-system hosts to perform Continuous Access, Business Copy, Database Validator, and Data Retention operations, as well as provisioning - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 204
be copied at the destination before acknowledging that it has been written at the source. The process in which a remote standby disk array takes over processing from the previously active local disk array. Target ID. Unit identification. Virtual Volume. Volume. Volume on disk. An accessible storage - HP P9000 | HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, May - Page 205
, 199 S storage capacity values conventions, 200 Subscriber's Choice, HP, 199 symbols in text, 201 T technical support HP, 199 service locator website, 200 text symbols, 201 typographic conventions, 200 W websites HP , 200 HP Subscriber's Choice for Business, 199 product manuals, 199 205
HP StorageWorks
P9000 RAID Manager Reference Guide
Abstract
This guide provides a command reference for HP StorageWorks P9000 RAID Manager Software on HP StorageWorks P9000
disk arrays. The intended audience is a storage system administrator or authorized service provider with independent knowledge
of HP StorageWorks P9000 disk arrays and the HP StorageWorks Remote Web Console.
HP Part Number: T1610-96034
Published: May 2011
Edition: Fifth