HP P9000 HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963
HP P9000 Manual
View all HP P9000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP P9000 manual content summary:
- HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 1
User Guide Abstract This guide explains how to use HP StorageWorks P9000 Continuous Access Journal Software to replicate data between local and remote HP StorageWorks P9000 disk arrays and to achieve disaster tolerance with maximum application performance. Topics include setting up remote copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 2
2010, 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 3
8 How Continuous Access Journal works 8 Hardware and software components 9 P9500 storage systems...10 Main and remote control units 10 Pair volumes...11 Journal volumes...11 Journals...11 Data path...12 Consistency groups and journals 12 Remote Web Console...12 RAID Manager...13 Overview of copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 4
Supported data path configurations 41 5 Configuration operations 43 Configuration workflow ...43 Define Fibre Channel port attributes 43 Configure storage systems for Continuous Access pair status information into a text file 74 Monitor copy operations data, I/O 75 Select data to be graphed - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 5
Recovery with Business Copy configuration 103 10 Troubleshooting 104 General troubleshooting...104 Troubleshooting logical paths 105 Troubleshooting suspended pairs 107 Troubleshooting using Remote Web Console 109 Error codes ...109 Troubleshooting using RAID Manager 109 Service information - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 6
11 Support and other resources 126 Contacting HP...126 Subscription service...126 Documentation feedback 126 Related information...126 HP websites...127 Conventions for storage capacity values 127 Typographic conventions...127 A Sharing Continuous Access Journal volumes 129 Volume types that can - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 7
Continuous Access Journal configurations with External Storage Access Manager 152 Overview...152 Configurations with Continuous Access Journal secondary volumes 152 E Continuous Access dialog box 176 DKC Operation window ...177 Remote Systems Information 178 Logical Path Information...179 Port - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 8
using multiple primary and secondary storage systems Continuous Access Journal software With Continuous Access Journal, application data is copied to a secondary P9500 system at a remote location. Continuous Access Journal is designed to support a remote site hundreds and even thousands - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 9
and secondary storage system are connected using a channel extender product. Hardware and software components A typical configuration consists of a P9500 or externally attached system on both local and remote sites, a host or hosts connected to the systems, Continuous Access Journal software on both - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 10
software consists of: • Remote Web Console graphical user interface (GUI) • RAID Manager NOTE: • Continuous Access Journal Z processing continues uninterrupted if the SVP reboots or even if the SVP fails. • Continuous Access Journal Z does not support operations in which one P-VOL is copied - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 11
: • Host I/O operations to the P-VOL • Master journal operations • Initial copy and update copy operations between the P-VOL and secondary volume (S-VOL). RCUs control the secondary storage volume (S-VOL) and the following operations: • Issue read-journal commands to the MCU. • Manage the copying of - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 12
Remote Web Console communicates with the SVP of each storage system over defined TCP/IP connections. • Remote Web Console must be LAN-attached to the primary system • Remote Web Console is not required on the secondary system; however having it available allows you to change Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 13
can only view Continuous Access Journal information. • If the RAID Manager computer is not installed, contact your HP account team for information on Continuous Access Journal configuration services. RAID Manager RAID Manager can be used to perform the same operations as the Remote Web Console GUI - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 14
system. In this case, the command to create the pair is rejected. The script is executed normally when you use the script without setting the system option on the primary storage system, however, note that the processing speed of the Continuous Access Synchronous initial copy slows down if there is - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 15
type of data transfer. Make sure that your channel extenders are capable of supporting RIO. Contact HP Technical Support for more information. If an update copy operation fails, the remote system suspends the affected pair or all Continuous Access Synchronous pairs in the journal. This is dependent - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 16
changes the S-VOL status to PSUS. The primary system detects the split (if path status is normal) and changes the P-VOL status to PSUS. 16 Continuous Access Journal overview - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 17
and secondary storage systems Interfaces Supported host platforms Data path The following program products can be used: • Remote Web Console Administrator or Continuous Access Journal write access is required; otherwise read access is provided with Remote Web Console. • RAID Manager UNIX based - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 18
Expansion volume is supported. Cache and Nonvolatile Storage (NVS) Host failover software Must be operable for primary and secondary systems to insure pair creation success. The remote system cache should be configured to adequately support Continuous Access Journal remote-copy workloads, as well - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 19
but not both. • Master and restore journals are managed according to the journal number. NOTE: The capacity of journal volume is not included in the accounting capacity. NOTE: Continuous Access Journal can co-exist with Continuous Access Journal Z in the same storage system. System requirements 19 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 20
business requirements to determine recovery requirements. • Measure your host application's write-workload in MB per second and write-input/output per second (IOPS) to begin matching actual data loads with the future Continuous Access . This involves understanding supported configurations, the need - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 21
RPO, the host application's write-workload over an extended period. software. You will use IOPS to set up a proper data transfer speed, which you insure through RAID group configuration and by establishing the number of Fibre Channel ports your Continuous Access Journal system requires. Each RAID - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 22
-workload and IOPS 1. Using your performance monitoring software, collect the following: • Disk-write bytes-per-second (MB/s) for every physical volume that will be replicated. • Data should be collected over a 3 or 4-week period to cover a normal, full business cycle. • Data should be collected - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 23
the remote array must be large enough to handle the production workload, and therefore must be the same size as master journals. If you are not planning for disaster recovery, remote journal volumes may be smaller than master journal volumes. Planning journals Continuous Access Journal manages pair - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 24
in different RAID groups. Fibre Channel port configuration The Fibre Channel ports on the P9500 have an IOPS threshold. Use the performance monitoring information for the number of IOPS your production system generates to calculate the number of Fibre Channel ports the Continuous Access Journal - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 25
-size LUs. When custom-size LUs are assigned to a Continuous Access Journal pair, the S-VOL must have the same capacity as the P-VOL. For details about Virtual LUN feature, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. • Identify the volumes that will become the P-VOLs and - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 26
are used for Continuous Access Journal are also used for Continuous Access Journal Z, Continuous Access Synchronous Z, and Continuous Access Synchronous. If you use Continuous Access Journal with Continuous Access Journal Z, Continuous Access Synchronous Z, and Continuous Access Synchronous, use the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 27
,768, the total number of LDEVs in the storage system is the maximum number of pairs that can be created. The maximum number of pairs is limited to 32,768. Priority set for initial copy operations and scheduling order For performing more initial copy operations than the setting value of the Maximum - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 28
maintain synchronization of a Continuous Access Journal pair, the primary storage system generates sense information. This information must be transferred to the remote site using the host failover software for effective disaster recovery. RAID Manager provides failover commands that interface with - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 29
: • "Continuous Access Journal configurations with Continuous Access Synchronous" (page 135) • "Continuous Access Journal configurations with Business Copy" (page 148) • "Continuous Access Journal configurations with External Storage Access Manager" (page 152) • "Sharing Continuous Access Journal - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 30
29). Figure 5 (page 30), Figure 6 (page 31), and Figure 7 (page 31) show varying configurations of storage systems in which multiple journals are registered in a single RAID Manager consistency group. Figure 5 RAID Manager consistency group with multiple journals-1 30 Planning volumes and systems - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 31
journals-2 Figure 7 RAID Manager consistency group with multiple journals-3 Planning for previous models Continuous Access Journal can be used to perform remote copy operations between P9500 and XP24000/XP20000 Disk Array. Data can be copied from P9500 to XP24000/XP20000 Disk Array, or vice versa - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 32
Web Console operations. See HP StorageWorks P9000 Remote Web Console User Guide for information. • Make sure that primary and secondary systems are properly configured for Continuous Access Journal operations; for example, cache memory considerations. See the item for Cache and Nonvolatile Storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 33
of the initial copy processing of the Continuous Access Journal pair can be improved by issuing the command from RAID Manager. Mode 474 ON: The performance of the initial copy processing of the Continuous Access Journal pair can be improved by issuing the command from RAID Manager. Mode 474 OFF - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 34
command is not saved in the shared memory. To reduce the number of multiprocessing of the communication command host I/O response during the Continuous Access Journal resync operation is reduced. Mode 760 OFF: Normal operations are performed. System option modes can only be changed by an HP - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 35
instructions for calculating bandwidth and designing the data path network. Data path design workflow To set up a data path, you need to establish the following: • The amount of bandwidth necessary to move the data generated by your host application copy the production disks, then an extended peak - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 36
system until the resync completes. Calculating bandwidth To determine bandwidth for Continuous Access Journal, write-workload must be measured. Production system workload data is collected using performance monitoring software. Please see "Measuring write-workload" (page 21). When you have collected - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 37
a safety factor. • Projected growth rate accounts for the increase expected in write-workload Most spreadsheet tools have an average function.) This instructs the tool to calculate the average value in cells B2 Base your calculations on your RPO.) b. Copy the value that displays in E4. c. Highlight - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 38
bandwidth must be able to handle. 3. With a base bandwidth value established, make adjustments for growth and a safety factor. • Projected growth rate accounts for the increase expected in write-workload over a 1, 2, or 3 year period. • A safety factor adds extra bandwidth for unusually high spikes - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 39
Journal operations. • RCU Target port: Receives Continuous Access Journal commands and data. RCU target ports must be configured on both primary and remote storage systems for Continuous Access Journal operations. • External port: Required for External Storage copy operations. This port is not used - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 40
redundancy. • Host paths cannot be connected to an initiator port. However, they can be attached to RCU target ports. NOTE: Two or more initiator ports must be configured before you can add the secondary storage systems and create the Continuous Access Journal volume pairs. Distances supported for - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 41
is a direct link between the local and remote arrays. NL-port (Node Loop) are supported for the data path and host-to-system path. • Switch connection, as remote switch and Fibre Channel to the remote system. F-port (Point-to-Point) and FL-port (Loop) switch connections are supported. • Extender - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 42
on particular switches, depending on the configuration and the settings of switch routing. For further details, contact your HP account team. • Make sure that your channel extenders are capable of supporting remote I/O. For further details, contact your HP account team. 42 Planning the data path - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 43
secondary systems for Continuous Access Journal command and data transfer. Prerequisite information • If initiator ports and RCU target ports are not configured on both primary and remote storage systems, the following problems occurs and remote copy operations are not performed: ◦ The administrator - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 44
system. To define port attributes 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. 2. Click to change the mode from View to Modify. 3. In the Display box, select Port. The ports associated with the local storage system are listed. 4. Right-click the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 45
Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. The DKC Operation window displays. 2. Click to change the mode from View to Modify. 3. In the Display box, select DKC. The tree and full list on the right-side display information about all remote storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 46
for a XP12000 Disk Array/XP10000 Disk Array storage system is 4. 8. The Path Gr. ID check box is intended for a future release. Continue to the next step. 9. In the M-R Path box, define the Fibre Channel port of the logical paths between the local storage system and the remote storage system: 1. In - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 47
supported. Prerequisite information Please review the prerequisites for configuring logical paths in "Configure storage systems for Continuous Access Journal, define logical paths " (page 45). To configure additional logical paths 1. In Remote Web Console, select Actions > Remote Copy > Continuous - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 48
path between local and remote systems: 1. In the Port, select a local system initiator port. 2. In the Pair-Port, select the remote system RCU target port. the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select Error - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 49
copy concurrently 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Optional Operation. 2. Click to change the mode from View default, 64 volumes, you limit the impact of initial copy operations on storage system performance. • When you specify more than 64, the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 50
OPEN-V. For details, see "System requirements" (page 17). • Journal volumes must be registered in a journal before the initial pair-copy operation is performed. • Journal volumes must be registered on both local and remote In Remote Web Console, select Actions > Remote Copy > Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 51
the mode from View to Modify. then enter the external parity group number in the box, and click Show. A list of volumes in the specified external parity group displays NOTE: In the current version, the Free Volume list shows only OPEN-V volumes. 6. Click Add. The added display in the Journal Volumes - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 52
want to add a another volume, select the journal to add a volume in the Preview list and right click and then select Modify. If the window opens, add a volume. • If you want to cancel a setting, select the volume in the Preview list and right click and then select Cancel. 9. Click Apply to - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 53
chapter provides procedures and prerequisite information for performing Continuous Access Journal copy operations. Pair operations workflow Basic Continuous Access Journal operations consists of the following. • Always check pair status. Each Continuous Access Journal operation requires the pair to - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 54
details about Performance Monitor, see HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. To create an initial copy or copies 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal> Pair Operation. 2. Click to change the mode from View to Modify - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 55
. If you selected multiple volumes as P-VOLs, the S-VOL you specify by the list is paired with the P-VOL displayed in P-VOL. Create the initial copy 55 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 56
instruct the system to automatically assign S-VOLs for the remainder of P-VOLs. Do this from the Select Other S-VOL(s) list, as follows: - Select Increment to cause Continuous Access Paircreate dialog box opens and the Select Other Continuous Access Journal pair for a delta resync. No initial copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 57
remote copy path error. Review performance. Operations on multiple pairs in the same consistency group with different statuses may result in suspension during high periods of write I/O. • Journal data may not be copied to the S-VOL depending on the option you select. • During normal Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 58
Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation. 2. Click to change the mode from View to Modify. 3. In the tree, select the port or host pair, update data is copied to the secondary data volume. When the secondary storage system receives a request for - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 59
split a mirror 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. 2. Click to change the mode from View to Modify. 3. In the , you can restart your business application at the primary storage system to resume business activities. Split a mirror 59 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 60
data that is not restored to the S-VOL of Continuous Access Journal exceeds 80% of the journal volume capacity, the S-VOL cannot be restored only copying the journal data to the restore journal volume in the Continuous Access Journal secondary storage system. In this case, based upon journal option - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 61
update operation needs not be performed for five minutes or more. See "Configuring the delta resync operation environment to support remote command devices" (page 142) for details. To restore a pair 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 62
the Continuous Access Journal pair for delta resync operation does not change after you perform the copy from the master journal to the restore journal restarts. Prerequisite information • The resynchronize a mirror operation is performed from the primary storage system only. • Use the RAID Manager - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 63
may result in suspension during high periods of write I/O. To resynchronize a mirror 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. 2. Click to change the mode from View to Modify. 3. In the tree, expand Registered then select the desired LDKC - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 64
the same host(s), HP strongly recommend that the secondary data volumes are defined to remain offline to avoid this problem. To delete a pair or pairs 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation. 2. Click to change the mode from View to Modify - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 65
a mirror, data copying between master and restore journals end. Prerequisite information • This operation can be performed from either the primary 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. 2. Click to change the mode from View to Modify - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 66
select Delete. 7. Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select Error Detail. 66 Pair operations - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 67
be repeated frequently. Email notifications of problems can be set up using the Remote Web Console. For details see HP StorageWorks P9000 Remote Web Console User Guide. To monitor pair status 1. In Remote Web Console, Click Actions > Remote Copy > Continuous Access Journal > Pair Operation. The Pair - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 68
access The user has split the pair or released the pair; the pair is no longer synchronized. Read/Write • The primary and secondary systems keep track of journal data discarded during the pairsplit operation. • When the operation is performed SMPL. • The pair or command devices are ready for the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 69
differential data will be copied to a S-VOL. access S-VOL access If data in the journal volume exceeds 80%, pair status changes Read/Write*3 Read Only to PFUL. The write data that inflows then is monitored during the Data Overflow Watch. PFUL status is displayed by RAID Manager. Remote Web Console - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 70
, Read Only data can be written to the S-VOL. • SSWS is displayed by RAID Manager, from which the horctakover command is issued. • Remote Web Console displays this status as PSUS or PSUE. S-VOL access Read/Write *1: Accessing the P-VOL depends on the status of the Cnt Ac-S pair that shares the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 71
the secondary systems. See "Usage Monitor window " (page 185) for instructions on viewing the usage rate of a journal volume. • When the pair status is COPY, you cannot add cache or shared memory to or remove it from the storage system. Before performing either of these tasks, split any pairs with - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 72
user has released the pair on the secondary system. • An error condition related to the secondary system, S-VOL, or an update operation. • The primary system is unable to communicate with the secondary system. • A Continuous Access was suspended before the initial copy operation was complete. The - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 73
system stops performing journal-obtain operations for the pair. However, the primary system continues the following operations: • Continues accepting write : • GID: Select the group number of a host group to be displayed. If you select All, all host groups display in the list. • Journal: Select - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 74
file access settings, see HP StorageWorks P9000 Remote Web Console User Guide. Following information of pair is described in the exported file: Item Port Gr(Name) LUN Vol Status JNL Mr S/N(LDKC) CNTL Port Gr LUN Vol JNL Type CTG ErrLv Sync CLPR CopyTime Description Port in the local storage system - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 75
Remote Web Console, click Actions > Remote Copy > Continuous Access Journal > Usage Monitor. The Usage Monitor window displays as shown in Figure 16 (page 75). The fields on the Usage Monitoring window are described in Table 9 (page 75). You start and stop monitoring in Performance Monitor. See HP - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 76
continued) Field Update Usage Monitor Graph Description The most recent data sample time of data on the graph. Remote I/O statistics and status of remote copy external volume (see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide for more information about external - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 77
. The unit is percent. The average transfer rate for initial copy operations. The unit is kilobytes per second. The number of asynchronous remote I/Os per second at the primary storage system. The number of journals at the primary storage system. The average transfer rate for journals in the primary - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 78
performed on the journal. Monitoring these statuses can help you resolve problems and maintain the Continuous Access Journal system. The status of a mirror associated to a Journal is viewed . To view journal status 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 79
operation. This is the unused journal which is not registered data volumes. Monitor logical path status To view logical path status 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. 2. In the Display box, select DKC and select LDKC. 3. Locate the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 80
logical path. • Normal. The path is established and ready to use for copy operations. • Nothing. An operation for configuring or deleting the path is in in the remote system might be in use for other connections. • Serial Number Mismatch. The serial number of the storage system connected to - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 81
either of the following: If Continuous Access Journal has not been started: 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > History. The History window opens. The History window may not show the latest operation history. To view the latest operation history, go - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 82
pairs in PAIR, PSUS, PSUE, HOLD, HOLDING, or HLDE status. To change the option 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation. 2. Click to change the mode from View to Modify. 3. In the tree, select the port that you have configured for the pair - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 83
Journal options used by journals Most Continuous Access Journal pair operations are performed on multiple pairs. This is In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. The Journal Operation window displays. 2. Click to change the mode from View to - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 84
journal data (initial copy or resynchronization data) in the cache memory on the remote side (restore journal). does not effect master journals unless the RAID Manager horctakeover command is used to change a master journal list. To view detailed information about the error, right click the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 85
Continuous Access Journal pair operations are performed on the primary storage system and secondary storage system. • To Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. The Journal Operation window displays. 2. Click to change the mode from View - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 86
initial copy activity per volume. This field cannot be specified on the remote to split immediately after a path becomes blocked, ask HP Technical Support to set system option mode 448 to ON and set storage system. For a pair using the delta resync configuration, select Yes in the primary storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 87
be deleted? No. No. Yes. Yes. To delete journal volumes 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. The Journal Operation window displays. 2. Click to change the mode from View to Modify. 3. In the tree, select one journal from below - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 88
system or secondary storage system. • When all mirrors in the journal are in the Initial status, you can delete the journal. • Master and restore journals cannot be deleted. To delete a journal 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 89
system and the RCU target port of the primary storage system. To delete a logical path 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. 2. Click to change the mode from View to Modify. 3. In the Display box, select DKC. The tree and full list - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 90
between them. • This operation must be performed on both the primary storage system and secondary storage systems. To delete the logical path between the primary and secondary storage system 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. The DKC - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 91
the secondary system during remote copy operations, the secondary system system, contact your HP account team and ask performing Continuous Access Journal operations; otherwise the pairs could be suspended with a failure. 4. When the system is ready to resume copy operations, on the primary storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 92
status of the pairs is changed to COPY or PAIR. After turning power on or off for both the primary and secondary system at the same time, if pair status at primary system is PSUS and a status of a pair of secondary storage system is PAIR, use Remote Web Console to suspend the pair of the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 93
the horctakeover command executes successfully, your business operations are taken over to (or your business application is started at) the secondary site using the S-VOLs. For detailed information about RAID Manager and horctakeover, see HP StorageWorks P9000 RAID Manager User Guide. Preparing for - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 94
by using RAID Manager. 1. At both Continuous Access Journal sites, make sure that Continuous Access Journal components are operational and free of failures. 2. Make sure that pair status of P-VOLs and S-VOLs in all Continuous Access Journal pairs is PAIR. 3. Stop the applications at the secondary - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 95
Continuous Access Journal secondary volumes in every secondary storage systems become SSWS. 4. Using the volumes in SSWS status in the secondary storage systems, resume the business tasks on the secondary site. For information on how to use RAID Manager, see HP StorageWorks P9000 RAID Manager User - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 96
Figure 17 Flow of the case of transferring the business tasks from the remote to primary site Recovery procedures with shared volumes Restoring operations with shared Continuous Access Journal and Continuous Access Synchronous or Business Copy volumes is a bit more complicated than with a straight - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 97
the procedure below. RAID Manager (RAID Manager) is used in this procedure: 1. Use RAID Manager to release the Continuous Access Journal pair. 2. Use RAID Manager to execute the horctakeover command on the Continuous Access Synchronous pair. 3. Use the Continuous Access Synchronous secondary volume - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 98
command, and then do either of the following: Procedure 3 1. If the primary/secondary relationship of the Continuous Access Synchronous pair is not reversed (that is, the copy direction is not reversed), use RAID Manager to create a Continuous Access Journal pair. P-VOL of the Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 99
current Continuous Access Journal pair, which extends between the Continuous Access Synchronous secondary site and the Continuous Access Synchronous secondary site. 2. Stop business tasks at the Continuous Access Synchronous secondary site. 3. Use RAID Manager to execute the horctakeover command on - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 100
Continuous Access Synchronous secondary site. 3. Use RAID Manager to execute the horctakeover command on the Continuous Access Synchronous pair. 4. Use the primary volume at the primary site to resume your business tasks. 5. When you perform delta resync operation on the volume in Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 101
to the primary site. To transfer your business tasks to the Continuous Access Journal secondary site, follow the procedure below. RAID Manager (RAID Manager) is used in this procedure: 1. Use RAID Manager to execute the horctakeover command on the Continuous Access Journal pair. 2. Use the volume in - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 102
not connected to the host, use the remote command device for Continuous Access Journal and Continuous Access Synchronous pair operations. Resume operations in the primary site When the primary site is restored, use RAID Manager and the following procedure to resume business operations at the primary - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 103
can continue business operations using the remote Continuous Access Journal secondary volume, and then restore data and business operations back to the primary site. Proceed as follows using RAID Manager: 1. Release the Business Copy pair using the pairsplit -S command. 2. Reverse the copy direction - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 104
troubleshooting information for Continuous Access Journal follows. Table 15 General troubleshooting Error Remote Web Console hangs, or Cnt Ac-J operations do not function properly. Corrective action Make sure that the problem is not being caused by the computer or Ethernet hardware or software - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 105
the Remote Web Console computer and the SVP, see HP StorageWorks P9000 Remote Web Console User Guide for instructions. Although HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. Troubleshooting logical paths Troubleshooting information for logical paths between storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 106
Table 16 Logical path troubleshooting (continued) Path status Serial Number Mismatch Description Corrective action The serial number (S/N) of Make sure that you entered the the error path. Check the specified port number or cable connections, and then retry the operation. 106 Troubleshooting - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 107
error during update copy. In this case, the suspend type for the S-VOL is usually by MCU. Check the path status on the DKC Status dialog box (see "Troubleshooting logical paths " (page 105)). Clear any error conditions at the secondary storage system and the S-VOL. If you need to access the S-VOL - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 108
was in correction-access status while the Cnt Ac-J pair was in COPY status. Recovery procedure According to SIM, remove the hardware blockade or failure. Restore the failed volume pairs (Pairresync) . If a failure occurs during execution of the RAID Manager horctakeover command, secondary volumes - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 109
. An SVP error code may also be included. See HP StorageWorks P9000 Remote Web Console Messages for details on error codes. If you need to call HP Technical Support for assistance, report the error code(s). Troubleshooting using RAID Manager When an error has occurred in Continuous Access Journal - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 110
error code is shown below. Table 19 RAID Manager error codes for Continuous Access Journal Error code (SSB1) Error code ( support the corresponding command. A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected because the specified P-VOL was used as the S-VOL of Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 111
on the remote storage system does not support the LUSE Continuous Access Synchronous because the Cont Access Journal 3DC & 4x4 Open external volume. The Cnt Ac-J pair cannot be created because the specified volume is part of a Business Copy or Flash Copy pair. Troubleshooting using RAID Manager - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 112
RAID Manager error codes for Continuous Access Journal (continued was in the state of online from the host. A request of Cnt Ac-J Paircreate Continuous Access Synchronous or the Business Copy. A request of Cnt Ac-J Paircreate was rejected because the specified volume was blocked. 112 Troubleshooting - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 113
, because Continuous Access Journal was not installed. The source of command devise has run out. Set to OFF the command device and to ON again from the LUN Manager. Cnt Ac-J Paircreate cannot be performed because the specified device is a command device. Troubleshooting using RAID Manager 113 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 114
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) B901/B9E0/B9E1/ B902 B9E2/B9E4/D004 B907 B90A B90D B909 B900 B94B B90B B90E B90F B910 B913 B912/B9F8 DB02 DB03 DB07 Error content Cnt Ac-J Paircreate cannot be performed because the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 115
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code ( request of Cnt Ac-J Paircreate was rejected because the path between the storage devices for the both-way was not defined. Check whether the bidirectional normal LDKCs. Troubleshooting using RAID Manager 115 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 116
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) A request of Cnt Ac-J Paircreate was rejected because the path between the storage devices for the both-way was not defined. Check whether the bidirectional normal registration again. 116 Troubleshooting - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 117
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code not for a Cnt Ac-J pair or was a volume of another journal. Cnt Ac-J copy pair cannot be suspended because of the power-on processing. A request of Cnt Ac-J was not Stopped. Troubleshooting using RAID Manager 117 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 118
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EA1B EA1C EA1E EA20 EA22 EA25 EA29 EA2C EA33 EA36 EA3A that consists of multiple primary and secondary systems was rejected because the microcode was being replaced. 118 Troubleshooting - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 119
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EA95 EAA2 EAA3 EAA5 EAA6 EAD0 EAE5 EAE7 EAEB EAF6 EB24 operation. • The status of the Cnt Ac-J pair is the status other than PAIR or SUSPEND. Troubleshooting using RAID Manager 119 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 120
RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EB28 EB29 EB2F EB30 EB45 EB48 Error content A request to create or resynchronize a pair in the system that consists of multiple primary and secondary systems was rejected because the Cont Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 121
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) RAID Manager horctakeover (resync) command was executed. The Cnt Ac-J pair create processing was doubly executed: • There are no problems if the initial copy operation is restarted when the primary storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 122
RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EB80 EB87 EB88 Error content The command Business Copy S-VOL. • The specified S-VOL was Not Ready, which means that the hard disk Being initialized by Business Copy. EBCA A either Business Copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 123
HP StorageWorks P9000 Remote Web Console User Guide, or call HP Technical Support for assistance. The figure below shows a typical 32-byte SIM from the system. The six-digit reference code consists of bytes 22, 23, and 13. The reference code identifies the possible error and determines the Service - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 124
host, except 21 80. Table 20 SIM reference codes, types, and descriptions Reference code Byte 22 Byte 23 21 80 21 81 21 82 DC 0X Severity Description System generating the SVP log SIM file Moderate Logical path is blocked due to a failure. Primary system/Secondary system Service - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 125
host. By default, system option mode 308 is set to OFF. Miscellaneous troubleshooting Suspension among journals All the journals in a consistency group can be suspended when an error occurs in one journal. This takes place under the following conditions: • The Continuous Access use RAID Manager and - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 126
P9000 Remote Web Console Messages • HP StorageWorks P9000 Remote Web Console User Guide You can find these documents on the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals In the Storage section, click Disk Storage Systems for hardware or Storage Software - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 127
, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/service_locator • http://www.hp.com/support/manuals • http://www.hp.com/support/downloads • http://www.hp.com/storage/whitepapers Conventions for storage capacity values P9000 disk arrays use the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 128
Table 21 Document conventions (continued) Convention Monospace text Element • File and directory names • System output • Code • Commands, their arguments, and argument values Monospace, italic text • Code variables • Command variables Monospace, bold text Emphasized monospace text WARNING! - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 129
Access Journal. Continuous Access Synchronous, Business Copy, and External Storage Access Manager volumes can be used extensively with Continuous Access Journal. For complete information, see: "Continuous Access Journal configurations with Continuous Access Synchronous" (page 135) "Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 130
and open systems Cache Residency The volume that is set Cache Residency Virtual LUN Virtual LUN volume LUN Manager Volume to which a path is defined Volume to which no path is defined Volume to which LUN security is applied Thin Provisioning Virtual volume External Storage Access Manager P-VOL - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 131
must be deleted and the volumes' status returned to SMPL. For more information about LUSE, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. Virtual LUN • Continuous Access Journal supports the Virtual LUN feature, which allows you to configure custom-size LU that are smaller than - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 132
Journal S-VOL, you might not be able to update the Continuous Access Journal S-VOL because the capacity of the pool-VOL is full. In this instance: ◦ The Continuous Access Journal status changes to PFUS ◦ The Remote Web Console status changes to PSUS ◦ The pair is suspended Data Retention You can - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 133
one or more storage systems before using Continuous Access Journal. 3. After you have disabled LDEV data collection and/or disconnected Performance Monitor wherever possible, then connect to the storage system using Remote Web Console and launch Continuous Access Journal. Performance Monitor 133 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 134
are completed, exit Continuous Access Journal and Remote Web Console. 5. Re-enable Performance Monitor data collection. For more information on Performance Monitor, see HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. 134 Sharing Continuous Access Journal volumes - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 135
with Continuous Access Synchronous Like Continuous Access Journal, a Continuous Access Synchronous pair maintains a copy of the production volume in a second location. However, unlike Continuous Access Journal, the Continuous Access Synchronous secondary volume (S-VOL) is synchronous, and the remote - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 136
at the local, Continuous Access Synchronous intermediate, and Continuous Access Journal remote sites. • RAID Manager is recommended at all sites. • Remote Web Console is required at all sites. ◦ Host application ◦ Continuous Access Synchronous ◦ Continuous Access Synchronous primary volume (P-VOL - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 137
1. Install and setup Continuous Access Synchronous and Continuous Access Journal on the required systems. 2. Create the Continuous Access Synchronous pair on the primary system. See HP StorageWorks P9000 Continuous Access Synchronous User Guide. 3. When Continuous Access Synchronous pair status is - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 138
Continuous Access Journal remote sites. • RAID Manager is recommended at all sites. • Remote Web Console is required at all sites. • The primary site requires the following: ◦ Continuous Access Synchronous ◦ Continuous Access Journal ◦ Continuous Access Synchronous P-VOL = Continuous Access Journal - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 139
Synchronous pair on the primary system. See HP StorageWorks P9000 Continuous Access Synchronous User Guide for instructions. 3. When Continuous Access Synchronous pair status is PAIR, create the Continuous Access Journal pair on the primary system. The mirror ID must be set between 1 and 3. Delta - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 140
operation, update the primary site 5 minutes after the status of the Continuous Access Journal pair and Continuous Access Synchronous pair becomes PAIR. If the delta resync operation to support remote command devices is performed, you can execute the delta resync operation after the primary site is - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 141
execute any other continuous access-related commands. If the delta resync operation to support remote command devices is performed, you can execute cannot copy only differential data by performing the delta resync operation, even if the pair status changes from HLDE to HOLD. However, you can copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 142
/remote command devices. Configure paths between external ports and target ports. For detail about the external ports, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. For instruction on setting paths, see HP StorageWorks P9000 Provisioning for Open Systems User - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 143
mirrors in one operation. To assign mirror IDs to remote command devices 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Journal Operation. The Journal Operation window displays. 2. Click to change the mode from View to Modify. 3. In the tree, select a master or - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 144
R-Cmd. Dev when you right-click the mirror. Release a remote command device which is assigned to a mirror Prerequisites To release a remote command device which is assigned to a mirror, perform this operation per mirror. 144 Continuous Access Journal configurations with Continuous Access Synchronous - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 145
To release a remote command device which is assigned to a mirror 1. Ensure that the Remote Web Console main window is in Modify mode. For detailed information about how to do this, see HP StorageWorks P9000 Remote Web Console User Guide. 2. Ensure that the Journal Operation window is open. 3. In the - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 146
to a host, a remote command device is required. See HP StorageWorks P9000 RAID Manager User Guide for more information. • Remote Web Console is required at all sites. • The primary site requires the following: ◦ Host application ◦ Continuous Access Synchronous ◦ Continuous Access Synchronous P-VOL - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 147
on the intermediate system. 4. When Continuous Access Journal pair status is PAIR, create the Continuous Access Synchronous pair on the primary system. See HP StorageWorks P9000 Continuous Access Synchronous User Guide. 5. Confirm that Continuous Access Synchronous pair status becomes PAIR. 2 data - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 148
details about Business Copy, see HP StorageWorks P9000 Business Copy User Guide. Overview Continuous Access Journal's main function is to maintain a copy of the production volume in a remote location. Backing up the local and/or remote Continuous Access Journal volumes with Business Copy, or backing - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 149
volume is illustrated below. With this configuration, multiple backup copies of the Continuous Access Journal primary volume can be made on the remote system. CAUTION: When you share a Continuous Access Journal S-VOL with a Business Copy P-VOL as shown in the following figure, the write operation - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 150
volume. A remote Continuous Access Journal backup copy is made of the Business Copy secondary volume. The Business Copy pair must be in PSUS status (Split) to perform the Continuous Access Journal operation. Figure 28 Shared Continuous Access Journal secondary volume with Business Copy primary - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 151
lowest LDEV ID. To see status for the pairs with a different secondary volume, direct a host query to the specific secondary volume using the secondary volume's LDEV ID in the host command. Pair status and data currency 151 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 152
the data from the split Cnt Ac-J S-VOL. For datails of disaster recovery, see HP StorageWorks P9000 External Storage Access Manager User Guide. Figure 29 Sharing an ESAM S-VOL with Continuous Access Journal P-VOL 152 Continuous Access Journal configurations with External Storage Access Manager - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 153
Journal GUI reference This appendix describes the Continuous Access Journal windows, dialog boxes, fields, and behaviors in Remote Web Console. Journal Operation window This window allows you to view details about journals and volumes. Information on the Journal Operation window will be updated - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 154
Lists journals in the local storage system. The tree shows journals used with Continuous Access Journal, though not Continuous Access Journal Z. • Journals: LDKC shows journals in which no journal volumes are registered. For instructions on how to register journal volumes in journals, see "Register - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 155
Initial copy is in progress. The P-VOL and the S-VOL are not synchronized. Initial copy is remote storage system. The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 156
.Dev: Assign a remote command device to a mirror • Release R-Cmd.Dev: Release an assigned remote command device • Blank: storage systems. Cancels settings in the Preview list. Journal Detail window This window lets you view detailed information about the individual journals. 156 Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 157
response to hosts). The Manager horctakeover command is used to change a master journal into a restore journal, this setting takes effect on the journal. If you set Use, this setting only takes effect on the journal volumes of RAID-5 or RAID-6 that are in the journal. For external volumes, non RAID - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 158
ID (model name that indicates the model) of the remote storage system. The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array is 4. This column is blank if the attribute - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 159
. See "Change Continuous Access Journal options used by journals " (page 83) for complete information. Item Description Inflow Control Restrict inflow of update data to the journal volume. Yes restricts inflow, No does not restrict (slows delay response to hosts - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 160
split (suspended) immediately after a path gets blocked, ask the HP Technical Support to set system option mode 448 to ON and set system when the delta resync operation cannot be performed-entire P-VOL is copied or no processing (S-VOL not updated). 87) 160 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 161
Shows external volumes belonging to a parity group. • CU: Shows volumes belonging to a CU. • Box: Where you either enter a PG and PG(Ext.) parity group number or select a CU. Define the function of the journal used in the 2DC cascade configuration of Continuous Access Journal and Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 162
copy " (page 53) • "Split a pair " (page 57) • "Restore a pair " (page 60) • "Delete a pair " (page 63) Item Tree Display Filter Export Previous/Next Description Lists the ports in the local storage system, with host for the currently shown 2,048 rows. 162 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 163
an external volume. For details on an external volume, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. copy is complete, the status changes to PAIR. PAIR: The volume is paired with another volume. The two volumes are fully synchronized. All updates from the host - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 164
COPY status to external volume. If a volume is a volume of XP24000/XP20000 Disk Array, "00" appears for the LDKC number. This column shows the port ID, GID, and LUN of the volume specified in the remote storage storage system is neither a P-VOL nor a S-VOL 164 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 165
continued) Used Volume Total Pairs Description • Pair JNL: The journal number for the remote storage system. This column is blank if the volume in the local storage operation (i.e., the progress of the paircreate operation reaches 100%). Copy Time on the History window shows the amount of time - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 166
settings in the Preview list to the storage systems. Cancels settings in the Preview list. Information in the VOL Column Information in The Paired VOL Column Detailed Information dialog box This dialog box lets you view details for a selected pair. 166 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 167
), Status also shows the suspend type. If the pair is waiting for initial copy, Status shows the word "Queuing". A pair's status varies between the P-VOL Ac-J operation is performed, the primary system changes the pair status of both P-VOL and S-VOL. If the volume in the local storage system is a P- - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 168
is a XP24000/XP20000 Disk Array volume. • For volumes shared with Business Copy or Continuous Access Synchronous, only the Cnt Ac-J pair status is shown. To see the Business Copy or Continuous Access Synchronous pair status, you must open those program products in Remote Web Console. The CLPR number - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 169
. Related Topics: • "Saving pair status information into a text file" (page 74) Paircreate dialog box This dialog box lets you create a pair. See "Create the initial copy " (page 53) for complete information. Pair Operation window 169 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 170
host P9000 External Storage for Open and Mainframe Systems User Guide. A device ID ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. For details on a virtual volume, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. 170 Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 171
GID is a group number for a host group. You can select only one S- the Paircreate dialog box opens and the Select Other Continuous Access Journal Z. CT Group DKC Initial Copy storage system. This option also allows you to specify the path type (that is, channel type). The secondary storage - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 172
Priority parameter. The time out error may be caused by the CU configuration or a remote copy path error. Review the error, release the pair with the error, and then retry the Paircreate operation. See "Split a pair " (page 57) for complete information. 172 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 173
host I/Os. The suspend pair operations should be performed under light I/O load conditions. If the following two conditions are satisfied and you select Apply, a warning message appears and processing cannot continue update data is copied to the S-VOL. When the secondary storage system receives a - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 174
. If Range is Mirror, you cannot change the Priority option. Indicates the followings about a remote storage system. • The serial number with the LDKC number. • The controller ID with the model . See "Delete a pair " (page 63) for complete information. 174 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 175
from frequency of host I/Os. The pair operations should be performed under light I/O storage system. This option may be used to free a host waiting for device end from a primary storage system that cannot communicate with its the secondary storage system, thus allowing host operations to continue - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 176
cache that is assigned to parity groups. If you select All, all CLPRs display in the list Whether internal volumes or external volumes display. All shows both kinds of volumes The pair status or statuses to display. Restores all options to the defaults. 176 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 177
Modify mode when you are in View mode. Use the DKC Operation window to: • "Configure storage systems for Continuous Access Journal, define logical paths " (page 45) • "Configure additional logical paths " (page 47) • View one of the following: ◦ "Remote Systems Information " (page 178) ◦ "Logical - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 178
click Apply. Indicates the operation in progress in the DKC Operation window. Remote Systems Information The list area on the DKC Operation window shows information about the remote system when you select DKC in the Display box and the LDKC in the tree. 178 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 179
the Cnt Ac-J software. The icon indicates the status of logical paths between the local storage system and the remote storage system: All the serial number and the LDKC number of the remote storage system. When the remote storage system is XP24000/XP20000 Disk Array, "00" appears as the LDKC number. - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 180
: A failure occurs at the logical path. More in depth status information can be viewed in the "DKC Status dialog box " (page 181). The port number of the local storage system. The port number of the remote storage system. Port Information for the local system The list area on the DKC Operation - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 181
on the local storage system: • Port: Port number. • Attribute: Port attribute (i.e., initiator, target, RCU target, or external) • PCB Mode: Mode of the port. The mode is either Standard, or High. • Error Code: An error code. DKC Status dialog box This dialog box lets you view status and other - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 182
Item No Path Status Description Number of the row. 182 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 183
to use for copy operations. • In remote system was performed. When clicked, the DKC Operation window refreshes when it redisplays. Add DKC dialog box This dialog box lets you configure local and remote systems for Continuous Access Journal pairs. See "Configure storage systems for Continuous Access - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 184
, 6 for P9500, 5 for XP24000/XP20000 Disk Array, 4 for XP12000 Disk Array/XP10000 Disk Array. Field intended for a future release. Logical path between local and remote systems. • Port: local system initiator port. • Pair-Port: remote system RCU target port. Opens DKC Option dialog box. DKC Option - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 185
The data collection interval. The most recent data sample time of data on the graph. Remote I/O statistics and status of remote copy monitor. History window This window lets you view the history of operations performed on pairs, and the data associated with each operation. Usage Monitor window 185 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 186
the progress (in %). When the updating is in progress, the checking process automatically continues until updating finishes. The updating process is checked at 10-second intervals. • Complete: more information, see "Export operations history " (page 189). 186 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 187
and the LDEV number). A volume ending in # (e.g., 00:00:3C #) indicates the LDEV is an external volume. For details, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. A volume ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 188
from the primary storage system. The status of the pair was changed from HOLD to COPY because of an operation from the primary storage system. The status of the pair was changed from HOLD to SMPL because of an operation from the primary storage system. 188 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 189
case, you can review the copy time in the remote storage system (LDKC : CU : LDEV). (7) Extended consistency group number (used only with Continuous Access Journal Z). If no EXCTG, hyphens (--) display. (8) Time taken for copying (from the start to the end of copying copy operation is performed - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 190
you are in View mode. Item Tree Activities Preview Operation Preview Apply Cancel Description Provides access to the storage system. Select Subsystem. Storage system option Preview list to the storage system. Cancels the settings in the Preview list. 190 Continuous Access Journal GUI reference - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 191
Access Journal that supports mainframe volumes. P9000 or XP Continuous Access Synchronous software. The version of Continuous Access Synchronous that supports mainframe volumes. A volume in the disk array that accepts Continuous Access, Business Copy, or P9000 for Business Continuity Manager - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 192
RAID level. In an XP disk array this is also referred to as an array group or parity group. The CLI configuration and replication tool for the P9000 or XP disk array that system administrators can use to enter RAID Manager commands from open-system hosts to perform Continuous Access, Business Copy - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 193
, 109 extender graphic, 42 external port, 39 F Fibre Channel, 40 fields Usage Monitor window, 75 file recovery;database recovery, 93 G graphing performance data, 76 Guidelines for preparing systems, 32 H help obtaining, 126 host failover software, 28 hosts supported, 17 how it works, 8 HP technical - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 194
, 102 PSUE, 72 PSUS types, 71 R RAID groups, planning, 24 RAID levels supported, 18 RCU target port, 39 related documentation, 126 remote command device about, setup;delta resync:using remote command devices with, 142 assigning mirrors, 143 remote I/O copy statistics, 77 required number of ports, 39 - HP P9000 | HP StorageWorks P9000 Continuous Access Journal User Guide (AV400-963 - Page 195
requirements, 17 T target port, 39 technical support HP, 126 service locator website, 127 text symbols, 128 Thin Provisioning, 130, 132 tracking journal data, 71 typographic conventions, 127 V Volume Types, 129 W websites HP , 127 HP Subscriber's Choice for Business, 126 product manuals, 126 195
HP StorageWorks
P9000 Continuous Access Journal User
Guide
Abstract
This guide explains how to use HP StorageWorks P9000 Continuous Access Journal Software to replicate data between local
and remote HP StorageWorks P9000 disk arrays and to achieve disaster tolerance with maximum application performance.
Topics include setting up remote copy connections, configuring the storage system, creating and monitoring remote copies,
recovering from a disaster, and troubleshooting. The intended audience is a storage system administrator or authorized service
provider with independent knowledge of HP StorageWorks P9000 disk arrays and the HP StorageWorks Remote Web Console.
HP Part Number: AV400-96373
Published: May 2011
Edition: Fourth